Farzin Akbar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Farzin Akbar has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Boris Rivkin
Professur für Neuartige Elektronik Technologien, Technische Universität Dresden, Nöthnitzer Str. 61, 01187 Dresden, Germany
3 shared publications - Mariana Medina-Sánchez
CIC nanoGUNE
3 shared publications - Azaam Aziz
Micro‐ and NanoBiomedical Engineering Group, Institute for Emerging Electronic Technologies Leibniz Institute for Solid State and Materials Research (IFW) 01069 Dresden Germany
2 shared publications - Christian Becker
Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
2 shared publications - Daniil Karnaushenko
Material Systems for Nanoelectronics Chemnitz University of Technology Chemnitz Germany
2 shared publications - Oliver. G. Schmidt
Material Systems for Nanoelectronics Chemnitz University of Technology Chemnitz Germany
2 shared publications
Latest Publications
- Open Access
Remotely Controlled Electrochemical Degradation of Metallic Implants
Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe‐based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on‐board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe‐30Mn‐1C/Pt galvanic cell model system is first investigated and high‐resolution X‐ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter‐sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.
Open AccessRemotely Controlled Electrochemical Degradation of Metallic Implants
Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe‐based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on‐board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe‐30Mn‐1C/Pt galvanic cell model system is first investigated and high‐resolution X‐ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter‐sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.
- Open Access
- 17 December 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (51) , eabl5408
Electronically integrated microcatheters based on self-assembling polymer films
Self assembled catheters with deep sub-mm diameters deliver liquids, carry out micromanipulation, and sense magnetic fields.
- 17 December 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (51) , eabl5408
Open AccessElectronically integrated microcatheters based on self-assembling polymer films
Self assembled catheters with deep sub-mm diameters deliver liquids, carry out micromanipulation, and sense magnetic fields.
- Open Access
- 29 October 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (44)
Self-sufficient self-oscillating microsystem driven by low power at low Reynolds numbers
Fast autonomous rhythmic motion is achieved in water for an artificial microsystem inspired by biologically relevant frequencies.
- 29 October 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (44)
Open AccessSelf-sufficient self-oscillating microsystem driven by low power at low Reynolds numbers
Fast autonomous rhythmic motion is achieved in water for an artificial microsystem inspired by biologically relevant frequencies.