Ivan Nunes Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ivan Nunes Santos has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Costa de Souza
Campus Itabira, Federal University of Itajubá, Itabira 35903-087, Brazil
2 shared publications - Bárbara Morais Gianesini
Power Quality Research Group, Faculty of Electrical Engineering, Federal University of Uberlndia, Uberlndia, MG, Brazil
2 shared publications - Paulo Fernando Ribeiro
Institute of Electrical Energy (ISEE) Federal University of Itajubá (UNIFEI) Itajubá
2 shared publications - Anderson Rodrigo Piccini
Instituto Federal de Educacao, Ciencia e Tecnologia do Parana - Campus Paranavai
1 shared publication Arthur Fernando Bonelli
Furnas Centrais Elétricas
1 shared publication- Camila de Oliveira Dias
Universidade Federal de Uberlândia, Brasil
1 shared publication
Latest Publications
- Open Access
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 86915-86925
Modeling, Simulation, and Prototype Fabrication of a Saturable-Core Reactor
This paper presents the complete development of a 500 kVAr saturable-core reactor prototype, including design, computational modeling, fabrication and laboratory testing. The design was based on classical electromagnetic‐circuit principles, and the resulting data were used by TRAEL Transformers to manufacture the equipment and were implemented computationally in ANSYS. Laboratory tests were conducted to assess its operation and effectiveness; among these, the power–voltage characteristic was used to compare experimental results with those from simulation. The analysis demonstrates that the design exhibits robust performance for power-system applications.
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 86915-86925
Open AccessModeling, Simulation, and Prototype Fabrication of a Saturable-Core Reactor
This paper presents the complete development of a 500 kVAr saturable-core reactor prototype, including design, computational modeling, fabrication and laboratory testing. The design was based on classical electromagnetic‐circuit principles, and the resulting data were used by TRAEL Transformers to manufacture the equipment and were implemented computationally in ANSYS. Laboratory tests were conducted to assess its operation and effectiveness; among these, the power–voltage characteristic was used to compare experimental results with those from simulation. The analysis demonstrates that the design exhibits robust performance for power-system applications.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24240197
Analysis of Complementarity between Renewable Sources in River Basins: a Proposed Methodology and a Brazilian Case Study
Exploring the natural complementarity that exists between renewables is pivotal for optimizing clean electricity generation. Quantifying this complementarity can enhance electrical planning, reducing waste of natural resources and guiding investment decisions more effectively. To quantify the complementarity existing in Brazilian river basins, a methodology was proposed. Data on influent natural energy, irradiance, and wind speed are analyzed using Python. Through a comprehensive process, the most suitable correlation coefficient is identified. The subsequent calculation of coefficients for specific source combinations and periods, as well as the application of the Innovative Trend Analysis methodology, allow an understanding of the existing complementarity dynamics. The methodology was applied to the Capivari River basin, located in the state of Paraná, which included a monthly analysis of complementarity between hydraulic generation with wind and photovoltaic sources from June 2016 to April 2024. There was no discrepancy in the interpretations of the results obtained for Spearman’s Rho and Kendall's Tau, although the magnitude of Kendall's Tau is, on average, 30% lower for the combination of photovoltaic and hydraulic and 49% for the combination of wind and hydraulic. The combination of wind and hydraulics exhibited seasonal complementarity, demonstrating lesser advantages compared to photovoltaic generation, with around 61% of the acquired values of Spearman’s Rho being negative, approximately 28% of which were negligible. This percentage is lower than the over 82% of negative values observed for the photovoltaic and hydraulic combination, of which 12% are negligible. The results are consistent with the literature and validate the proposed methodology.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24240197
Open AccessAnalysis of Complementarity between Renewable Sources in River Basins: a Proposed Methodology and a Brazilian Case Study
Exploring the natural complementarity that exists between renewables is pivotal for optimizing clean electricity generation. Quantifying this complementarity can enhance electrical planning, reducing waste of natural resources and guiding investment decisions more effectively. To quantify the complementarity existing in Brazilian river basins, a methodology was proposed. Data on influent natural energy, irradiance, and wind speed are analyzed using Python. Through a comprehensive process, the most suitable correlation coefficient is identified. The subsequent calculation of coefficients for specific source combinations and periods, as well as the application of the Innovative Trend Analysis methodology, allow an understanding of the existing complementarity dynamics. The methodology was applied to the Capivari River basin, located in the state of Paraná, which included a monthly analysis of complementarity between hydraulic generation with wind and photovoltaic sources from June 2016 to April 2024. There was no discrepancy in the interpretations of the results obtained for Spearman’s Rho and Kendall's Tau, although the magnitude of Kendall's Tau is, on average, 30% lower for the combination of photovoltaic and hydraulic and 49% for the combination of wind and hydraulic. The combination of wind and hydraulics exhibited seasonal complementarity, demonstrating lesser advantages compared to photovoltaic generation, with around 61% of the acquired values of Spearman’s Rho being negative, approximately 28% of which were negligible. This percentage is lower than the over 82% of negative values observed for the photovoltaic and hydraulic combination, of which 12% are negligible. The results are consistent with the literature and validate the proposed methodology.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (9) , 1007-1014
Control proposal for photovoltaic inverters with reactive power supply for voltage stability during momentary sags and in steady state
This work aims to present a control proposal for dual-stage photovoltaic inverters to supply reactive power aiming at voltage stability in steady state and during short-term momentary sags. For this, a study was carried out on the control and modeling techniques of the DC/DC and DC/AC converters of the photovoltaic generating unit, in addition, a modified MPPT algorithm was implemented that, together with an AVR system, will manage the power in transient regime, decreasing the active power and increasing the reactive power in order to restore the voltage level in the grid. In addition, the dynamic saturation of the current in the switches and the power of the inverter was carried out so that they operate within their nominal limits. The entire system was executed in a computational environment on the Matlab/Simulink platform. Satisfactory results were obtained regarding the supply of reactive power and assistance in voltage restoration carried out by distributed generation during momentary sag.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (9) , 1007-1014
Control proposal for photovoltaic inverters with reactive power supply for voltage stability during momentary sags and in steady state
This work aims to present a control proposal for dual-stage photovoltaic inverters to supply reactive power aiming at voltage stability in steady state and during short-term momentary sags. For this, a study was carried out on the control and modeling techniques of the DC/DC and DC/AC converters of the photovoltaic generating unit, in addition, a modified MPPT algorithm was implemented that, together with an AVR system, will manage the power in transient regime, decreasing the active power and increasing the reactive power in order to restore the voltage level in the grid. In addition, the dynamic saturation of the current in the switches and the power of the inverter was carried out so that they operate within their nominal limits. The entire system was executed in a computational environment on the Matlab/Simulink platform. Satisfactory results were obtained regarding the supply of reactive power and assistance in voltage restoration carried out by distributed generation during momentary sag.
- 7 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2398-2407
Comparison of Methods for Determining Harmonic Distortion Contributions Using the IEEE Benchmark Test System
The growing use of nonlinear devices has raised the harmonic levels in power systems. A challenging power quality problem is determining how much each installation contributes to the harmonic voltages measured at a point of common coupling so that the costs of mitigation solutions can be fairly divided. Currently, there is still no practical worldwide established method to solve this problem. The IEEE PES Task Force on Harmonic Modeling and Simulation developed a Benchmark Test System to support this line of research. Therefore, this study uses the IEEE PES Benchmark to evaluate and compare harmonic contribution determination (HCD) methods. To do so, this Benchmark Test System was implemented in MATLAB/Simulink and used to test five HCD methods proposed in the literature under different network operating cases, including cases with background distortions and resonance. The methods are the Voltage Harmonic Vector Method, the IEC Method, the Dominant Impedance Method, the Capacitor Switching Method, and the Harmonic Current Injection Method. It has been found that the HCD methods generally led to similar contribution percentages, proving the convergence of the methodologies. In addition, an analysis of the methods' sensitivity to input measurement errors was done.
- 7 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2398-2407
Comparison of Methods for Determining Harmonic Distortion Contributions Using the IEEE Benchmark Test System
The growing use of nonlinear devices has raised the harmonic levels in power systems. A challenging power quality problem is determining how much each installation contributes to the harmonic voltages measured at a point of common coupling so that the costs of mitigation solutions can be fairly divided. Currently, there is still no practical worldwide established method to solve this problem. The IEEE PES Task Force on Harmonic Modeling and Simulation developed a Benchmark Test System to support this line of research. Therefore, this study uses the IEEE PES Benchmark to evaluate and compare harmonic contribution determination (HCD) methods. To do so, this Benchmark Test System was implemented in MATLAB/Simulink and used to test five HCD methods proposed in the literature under different network operating cases, including cases with background distortions and resonance. The methods are the Voltage Harmonic Vector Method, the IEC Method, the Dominant Impedance Method, the Capacitor Switching Method, and the Harmonic Current Injection Method. It has been found that the HCD methods generally led to similar contribution percentages, proving the convergence of the methodologies. In addition, an analysis of the methods' sensitivity to input measurement errors was done.
- Open Access
- 26 October 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (12) , e13149
Blind source separation methods applied to evaluate harmonic contribution
One of the greatest challenges found in power quality has been, and still is, the establishing of a reliable noninvasive method for quantifying the harmonic contributions of an electric utility and a consumer at the point of common coupling (PCC). This difficulty arises from the fact that the harmonic distortions measured on the PCC are unidentifiable mixtures from both parties. Currently, some work has focused on exploring the use of blind source separation (BSS) techniques to promote the sharing of harmonic responsibilities in a noninvasive way. However, the usage of this methodology is very recent and still requires thorough evaluations, not only from the point of view of the BSS techniques available in the literature, but also from the perspective of the electrical power systems and the nature of their loads. Thus, seeking to contribute to the consolidation of the use of BSS techniques in the sharing of harmonic responsibilities, this work aimed to investigate the impact of the variation of harmonic current sources on the accuracy of BSS methods. In addition, three algorithms suitable for complex-valued signals were evaluated computationally and experimentally; the results obtained computationally were compared with the results of the method based on the covariance characteristic of the random vectors, and the experimental results was compared to that obtained through an invasive procedure.
- 26 October 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (12) , e13149
Open AccessBlind source separation methods applied to evaluate harmonic contribution
One of the greatest challenges found in power quality has been, and still is, the establishing of a reliable noninvasive method for quantifying the harmonic contributions of an electric utility and a consumer at the point of common coupling (PCC). This difficulty arises from the fact that the harmonic distortions measured on the PCC are unidentifiable mixtures from both parties. Currently, some work has focused on exploring the use of blind source separation (BSS) techniques to promote the sharing of harmonic responsibilities in a noninvasive way. However, the usage of this methodology is very recent and still requires thorough evaluations, not only from the point of view of the BSS techniques available in the literature, but also from the perspective of the electrical power systems and the nature of their loads. Thus, seeking to contribute to the consolidation of the use of BSS techniques in the sharing of harmonic responsibilities, this work aimed to investigate the impact of the variation of harmonic current sources on the accuracy of BSS methods. In addition, three algorithms suitable for complex-valued signals were evaluated computationally and experimentally; the results obtained computationally were compared with the results of the method based on the covariance characteristic of the random vectors, and the experimental results was compared to that obtained through an invasive procedure.
- 12 January 2016
- Published by Portal de Periódicos UFU - Universidade Federal de Uberlandia in Ciência & Engenharia
- Vol. 25 (1) , 145-154
Avaliação de desempenho de modelos computacionais representativos de painéis fotovoltaicos
- 12 January 2016
- Published by Portal de Periódicos UFU - Universidade Federal de Uberlandia in Ciência & Engenharia
- Vol. 25 (1) , 145-154
Avaliação de desempenho de modelos computacionais representativos de painéis fotovoltaicos
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (15406008) , 708-712
Methodology for estimation of harmonic hosting
The increasing penetration of distributed generation with non-linear characteristics demands a clear methodology for determining the amount of generation that can be connected to the system without deteriorating the performance. This paper proposes a methodology for determining the hosting capacity regarding harmonic distortions. To exemplify an application of the proposed procedure, a simple case study is performed and analyzed.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (15406008) , 708-712
Methodology for estimation of harmonic hosting
The increasing penetration of distributed generation with non-linear characteristics demands a clear methodology for determining the amount of generation that can be connected to the system without deteriorating the performance. This paper proposes a methodology for determining the hosting capacity regarding harmonic distortions. To exemplify an application of the proposed procedure, a simple case study is performed and analyzed.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-5
Modified superposition method for assignment of responsibilities on harmonic distortions
Considering the guidelines contained in documents such as the IEEE Standard 519 and IEC 61000-3-6 that includes, among other indexes of power quality, the thematic of the harmonic distortion, the mentioned text refers to issues associated with definitions, measuring procedures, reference values, etc. Taking under consideration these determinations, and recognizing that the mitigating solutions for the adequacy of performance indexes involve significant financial costs, the proposition of finding ways to determine the responsibility for possible violations of pre-established limits for harmonic distortion arises. Among the proposals found to detect the contribution portions coming from the supplier and the customer, it is noteworthy that, in general, the methodologies based on principles use the frequency domain harmonized with the superposition of effects. Despite the simplicity of this procedure, it is emphasized that it relies on measuring information and on the previous knowledge of the equivalent harmonic impedances of the utility and customer, whose information are of difficult access. In this context, this paper is focused on a feasibility proposition to solve the above mentioned difficulties in obtaining the percentage of responsibility between the parties.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506647,p. 1-5
Modified superposition method for assignment of responsibilities on harmonic distortions
Considering the guidelines contained in documents such as the IEEE Standard 519 and IEC 61000-3-6 that includes, among other indexes of power quality, the thematic of the harmonic distortion, the mentioned text refers to issues associated with definitions, measuring procedures, reference values, etc. Taking under consideration these determinations, and recognizing that the mitigating solutions for the adequacy of performance indexes involve significant financial costs, the proposition of finding ways to determine the responsibility for possible violations of pre-established limits for harmonic distortion arises. Among the proposals found to detect the contribution portions coming from the supplier and the customer, it is noteworthy that, in general, the methodologies based on principles use the frequency domain harmonized with the superposition of effects. Despite the simplicity of this procedure, it is emphasized that it relies on measuring information and on the previous knowledge of the equivalent harmonic impedances of the utility and customer, whose information are of difficult access. In this context, this paper is focused on a feasibility proposition to solve the above mentioned difficulties in obtaining the percentage of responsibility between the parties.