Guoliang Zhai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guoliang Zhai has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Qinqin Wei
College of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, China
1 shared publication - Xiangke Zhang
College of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, China
1 shared publication - Yajing Wang
School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, China
1 shared publication - Zhenhai Dou
School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo 255000, China
1 shared publication - Zhenming Liu
College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
1 shared publication
Latest Publications
- Open Access
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 142925-142937
Residual Current Detection Method Based on Variational Modal Decomposition and Dynamic Fuzzy Neural Network
To further improve the detection ability of residual current in low-voltage distribution networks, an adaptive residual current detection method based on variational mode decomposition (VMD) and dynamic fuzzy neural network (DFNN) is proposed. First, using the general $K$ -value selection method of VMD proposed in this study, the residual current signal is decomposed into $K$ intrinsic mode functions (IMFs). By introducing the cross-correlation coefficient $R$ and the time-domain energy entropy ratio $E$ as two classification indexes, IMFs are divided into three categories: effective IMFs, noise IMFs and aliasing IMFs. Then, the aliasing IMFs are denoised by recursive least squares (RLS), and the denoised IMFs are superimposed with the effective IMFs to obtain the reconstructed signal. Finally, the dynamic fuzzy neural network (DFNN) is adjusted by the minimum output method to achieve the detection of the reconstructed residual current signal, and the network is used to predict the residual current according to the detection results. The detection results of the simulation and measured data show that the proposed algorithm has high detection accuracy and is superior to the wavelet neural network, empirical mode decomposition-thresholding, and wavelet entropy-auto encoder-back propagation neural network methods in terms of mean square error, goodness of fit and running time. This method provides a reference for further research on new adaptive residual current protection devices.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 142925-142937
Open AccessResidual Current Detection Method Based on Variational Modal Decomposition and Dynamic Fuzzy Neural Network
To further improve the detection ability of residual current in low-voltage distribution networks, an adaptive residual current detection method based on variational mode decomposition (VMD) and dynamic fuzzy neural network (DFNN) is proposed. First, using the general $K$ -value selection method of VMD proposed in this study, the residual current signal is decomposed into $K$ intrinsic mode functions (IMFs). By introducing the cross-correlation coefficient $R$ and the time-domain energy entropy ratio $E$ as two classification indexes, IMFs are divided into three categories: effective IMFs, noise IMFs and aliasing IMFs. Then, the aliasing IMFs are denoised by recursive least squares (RLS), and the denoised IMFs are superimposed with the effective IMFs to obtain the reconstructed signal. Finally, the dynamic fuzzy neural network (DFNN) is adjusted by the minimum output method to achieve the detection of the reconstructed residual current signal, and the network is used to predict the residual current according to the detection results. The detection results of the simulation and measured data show that the proposed algorithm has high detection accuracy and is superior to the wavelet neural network, empirical mode decomposition-thresholding, and wavelet entropy-auto encoder-back propagation neural network methods in terms of mean square error, goodness of fit and running time. This method provides a reference for further research on new adaptive residual current protection devices.