ZZZhen Zhang

Zhen Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhen Zhang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhanced cascade control approach for non-orthogonal shafting laser tracking systems based on fuzzy control techniques

    by Hongyu Zhang, Zefeng Sun, Yuhang Zhang, Zhen Zhang, Yulei Cao, Jiehu Kang, Bin Wu

    The non-orthogonal shafting design is motived by the growing demand for large-scale measurement instrument, and the matching laser tracking technology is required to be completed to improve the automation and flexibility. While, due to the complexity and nonlinearity of non-orthogonal shafting architecture, it is difficult to calculate the rotation angles of the two axes based on the tracking deviation in the absence of distance information, and traditional proportional, integral and differential method cannot enable the system to adapt to unknown sudden target movement efficiently. Thus, the enhanced cascade control method for non-orthogonal shafting laser tracking system based on fuzzy control theories is proposed in this paper. Firstly, a position loop fuzzy prediction and tracking algorithm is proposed. Based on the current motion state of the target, the fuzzy controller predict the motion trend and calculate the tracking speed of the two axes. By implementing a two-stage model of coarse adjustment and fine adjustment, the responsiveness and stability of the laser tracking system have been improved. Secondly, the particle swarm optimization algorithm is adopted to conduct offline iterative optimization of the parameters of the scaling factor in the variable universe fuzzy control, achieving the rapid adaptability of the speed loop. The simulation results show that, compared with cascade PI control, this method has a faster response speed and a smaller tracking error. The experimental results show that the average dynamic tracking error and average static tracking error of this method are 1.873 58 mm and 0.026 89 mm respectively, and the fastest tracking speed of the non-orthogonal system is better than 7° s −1 .

  • Optical-Carrier Microwave Scanning Interferometry Ranging System Based on Linear Stepped-Frequency Modulation

    by Wenbo Zheng, Jiehu Kang, Yanan Zhan, Zhen Zhang, Yulei Cao, Zefeng Sun, Yuhang Zhang, Jiantao Yue, Yu Hao, Yupeng Zhao, et al.

  • Multi-Channel Absolute Distance Measurement Based on Optical Carrier-Based Microwave Scanning Interferometry With Frequency Division Multiplexing

    by Yulei Cao, Zhen Zhang, Yu Hao, Jianwei Zhang, Wenbo Zheng, Zefeng Sun, Hongyu Zhang, Jiehu Kang, Bin Wu

    Precise multi-channel distance measurement is crucial for many fields such as fundamental scientific research and industrial measurement. However, existing laser ranging technologies face limitations including restricted multi-channel scalability, demanding fabrication requirements, high costs, and structural complexity. A multi-channel absolute distance measurement method based on optical carrier-based microwave scanning interferometry (OCMSI) with frequency division multiplexing is proposed in this paper. Different measurement channels are allocated to distinct microwave frequency bands, and channels are physically isolated using bandpass filters, effectively eliminating the impact of inter-channel crosstalk on distance measurement. The multi-channel absolute distance measurement is achieved without requiring additional optical carrier-based microwave modulation, demodulation, or data acquisition equipment. A data processing approach combining data segmentation, amplitude-modulated root-cosine (AMRC) function fitting, and a global optimization algorithm is proposed. Distance calculation is accomplished by leveraging amplitude spectrum information. Experimental results validate the effectiveness and high performance of the proposed multi-channel ranging method and data processing approach. Experiments demonstrate that the proposed multi-channel ranging method achieves a measurement accuracy better than ±37 μm and repeatability better than 19 μm. Furthermore, by increasing the sweep bandwidth, the accuracy and repeatability can be improved to ±20 μm and 2 μm, respectively.


  • A High-Precision Micro-Hole Circle Detection Method via Lightweight Focusable Network and Accelerated Resolution-Aware Hough Transform

    by Zongyang Zhao, Jiehu Kang, Yuqi Ren, Yichen Xu, Zefeng Sun, Zhen Zhang, Ting Xue, Bin Wu

    Micro-holes with small diameters and large aspect ratios require endoscopic probes for deep morphological inspection. Accurate identification of the micro-hole center is essential for precise probe alignment. However, current industrial production lines rely on manual alignment, a time-consuming and labor-intensive process with limited accuracy. Moreover, existing Hough transform-based circle detection methods exhibit poor robustness, often failing in real-world environments, which leads to alignment errors. To address these challenges, this paper proposes a high-precision micro-hole circle detection method that integrates a lightweight focusable network (LF-Net) with a resolution-aware Hough transform (A-RAHT). The method first generates precise micro-hole masks and then efficiently detects circles. Specifically, LF-Net employs a global grouped linear embedding structure and a dynamic channel sparsity mechanism to reduce computational complexity while effectively modeling long-range dependencies, capturing more representative high-level features of micro-hole circles. Then, an adaptive Sobel operator combined with a multiscale receptive field focusable module is introduced to accurately extract circle masks. Finally, A-RAHT partitions the image into multiple regions and applies multi-threaded acceleration alongside a coarse-to-fine resolution-aware Hough transform, enabling accurate and efficient circle detection. Experimental results demonstrate that the proposed method achieves state-of-the-art performance in detecting micro-hole circles in real industrial environments, significantly enhancing automation and precision. Furthermore, additional experiments across various scenarios validate its robustness and generalization capabilities, making it well-suited for high-precision and real-time circle detection in diverse practical applications.


  • Optical-Carried Microwave Scanning Interferometry Ranging Method Based on Real-Time Amplitude Spectrum Detection

    by Yulei Cao, Zefeng Sun, Jiehu Kang, Zhen Zhang, Dongchen Sun, Yanan Zhan, Ruihao Liu, Bin Wu

    Distance measurement technology is of great significance to scientific research and industrial production. As an emerging technology, optical-carried microwave scanning interferometry (OCMSI) technology has been applied in the field of high-precision distance measurement. However, OCMSI ranging often requires the aid of the vector network analyzers (VNA), which limits the instrumentation and modularization of the OCMSI ranging system. To overcome this, the OCMSI amplitude spectrum detection and calculation technology is proposed in this paper. Firstly, a miniaturized real-time amplitude detection unit (ADU) is designed to demodulate the amplitude of the optical-carried microwave interference signal efficiently. The amplitude of this signal is converted into the amplitude spectrum containing distance information. Furthermore, the multisegment synthetic Fourier series fitting (MSFSF) algorithm is proposed to achieve the high accurate and repeatable distance calculation. In the 10 m range, experiments of measurements for various distances are promoted, the ranging accuracy is ± 0.052 mm and the repeatability is 0.019 mm. These two indexes for the OCMSI ranging results are essentially in the same order of magnitude as using VNA. The experiment shows that the proposed OCMSI ranging method is of great significance to the related technologies promotion in practical applications.


  • A cross-correlation driven adaptive dual-domain enhancement method for OCMSI measurement

    by Yu Hao, Zhen Zhang, Yulei Cao, Yuqi Ren, Jianwei Zhang, Zefeng Sun, Jiehu Kang, Wenbo Zheng, Wu Bin


  • Microwave Photonic Mixing Approach to Doppler Frequency Shift Measurement

    by Zhen Zhang, Jiehu Kang, Ruihao Liu, Zefeng Sun, Luyuan Feng, Bin Wu

    A microwave photonic mixing approach to laser Doppler frequency shift (DFS) measurement employed for high velocity estimation is proposed. Based on optical carrier-based microwave interferometry, the DFS of the light wave frequency domain is mapped to the microwave frequency domain. With modulated broadband light wave, the sufficiently small coherence length of light wave is produced, avoiding the influence of optical interference on photonic mixing. Compared to conventional laser DFS measurement, the frequency of intermediate frequency (IF) signal can be reduced by 4&5 orders of magnitude. Microwave photonic mixing based on heterodyne interferometer is also performed to eliminate the direction ambiguity of motion. In a proof-of-concept experiment, the frequency shifts from 0 to 100 kHz with a frequency shift error of <30 Hz at wide bandwidth can be achieved. For radial velocity estimation, these results reveal a range from 0 to 3000 m/s and a resolution of <0.9 m/s at 5-GHz frequency band.


  • Microwave photonics frequency scanning approach to absolute distance measurement

    by Zhen Zhang, Jiehu Kang, Ruihao Liu, Yulei Cao, Zefeng Sun, Luyuan Feng, Bin Wu


  • Multi-Channel Absolute Distance Measurement Based on Optical Carrier-Based Microwave Scanning Interferometry

    by Zhen Zhang, Jiehu Kang, Ruihao Liu, Yulei Cao, Yu Hao, Zefeng Sun, Luyuan Feng, Zongyang Zhao, Bin Wu, Ting Xue

    Cost-efficient multi-objective synchronous ranging solutions are highly desired in many fields such as manufacturing and infrastructure. However, traditional laser ranging methods have limitations in absolute ranging and multi-channel expansion. In this paper, a multi-channel absolute distance measurement method based on optical carrier-based microwave scanning interferometry (OCMSI) is proposed. After microwave scanning and synchronous demodulation, the amplitude spectrums and phase spectrums of interference signals are established. The transmission signals of each channel can be separated and reconstructed by using the discrete Fourier inverse transform. Additionally, it is demonstrated that the designed global optimization algorithm for extracting free spectral range can effectively reduce the impact of detection errors and channel interference. Existing interferometers can achieve multi-channel parallel absolute distance measurement without the need for additional modulation, demodulation, and optoelectronic detection devices. Experimental results have shown that the system structure is simple, and the ranging accuracy of for 3 channels is higher than ± 60 μm within at least 35 m optical path.