Navid Vafa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Navid Vafa has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Manuela Scamardo
Department of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, 20133 Milan, Italy
3 shared publications - Sara Cattaneo
Department of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
3 shared publications - Pietro Crespi
Department of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Piazza Leonardo da Vinci 33, 20133 Milan, Italy
2 shared publications Jan Rots
1 shared publication- Luigi Biolzi
Politecnico di Milano
1 shared publication - Paul A. Korswagen
Delft University of Technology
1 shared publication
Latest Publications
- 15 March 2026
- Published by Springer Nature
- p. 618-632
Parametric Study on the Influence of Core Capping in Assessing the Compressive Properties of Historical Masonry
- 15 March 2026
- Published by Springer Nature
- p. 618-632
Parametric Study on the Influence of Core Capping in Assessing the Compressive Properties of Historical Masonry
- 7 May 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 430
Numerical investigation on pull-out behavior of twisted steel connectors for masonry retrofitting
- 7 May 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 430
Numerical investigation on pull-out behavior of twisted steel connectors for masonry retrofitting
- Open Access
- 6 November 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 409
Cyclic behavior of masonry walls retrofitted with post-installed twisted bars or bonded rebars
- 6 November 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 409
Open AccessCyclic behavior of masonry walls retrofitted with post-installed twisted bars or bonded rebars
- Open Access
- 18 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5090
Parametric Analyses of the Response of Masonry Walls with Reinforced Plaster
This paper presents the results of a parametric study on the response of unreinforced and retrofitted masonry specimens. The adopted strengthening technique is the steel-reinforced plaster, which is very commonly used but it is not supported by a proper theoretical and experimental characterization in the scientific literature. The aim was to investigate the main parameters that affect the structural performances of the walls. Several numerical models were implemented using the finite element method to analyze the influence of the bricks’ arrangements, the mechanical properties of the mortar joints, the number of connectors, and the mechanical properties and thickness of the plaster coating. A concrete damage plasticity model was adopted to describe the bricks, the mortar joints, and the plaster behaviors. For the unreinforced specimens, the outcomes confirmed that the mortar strength had a significant influence on the performance of the wall, together with the presence of potential weaknesses in the bricks, while the bond effect was negligible. For reinforced walls, the connectors do not have a significant influence on retrofitted wall capacity but may prevent instability if a proper number is considered. Furthermore, the strength of the plaster coating does not affect the collapse load significantly, while increasing the fracture energy, which can be produced, for instance, by using fiber-reinforced concrete, increases the capacity of retrofitted walls, with more limited damage. Finally, an increase in the plaster thickness may be beneficial in terms of collapse load, even though greater thickness may increase the seismic masses significantly.
- 18 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5090
Open AccessParametric Analyses of the Response of Masonry Walls with Reinforced Plaster
This paper presents the results of a parametric study on the response of unreinforced and retrofitted masonry specimens. The adopted strengthening technique is the steel-reinforced plaster, which is very commonly used but it is not supported by a proper theoretical and experimental characterization in the scientific literature. The aim was to investigate the main parameters that affect the structural performances of the walls. Several numerical models were implemented using the finite element method to analyze the influence of the bricks’ arrangements, the mechanical properties of the mortar joints, the number of connectors, and the mechanical properties and thickness of the plaster coating. A concrete damage plasticity model was adopted to describe the bricks, the mortar joints, and the plaster behaviors. For the unreinforced specimens, the outcomes confirmed that the mortar strength had a significant influence on the performance of the wall, together with the presence of potential weaknesses in the bricks, while the bond effect was negligible. For reinforced walls, the connectors do not have a significant influence on retrofitted wall capacity but may prevent instability if a proper number is considered. Furthermore, the strength of the plaster coating does not affect the collapse load significantly, while increasing the fracture energy, which can be produced, for instance, by using fiber-reinforced concrete, increases the capacity of retrofitted walls, with more limited damage. Finally, an increase in the plaster thickness may be beneficial in terms of collapse load, even though greater thickness may increase the seismic masses significantly.
- Open Access
- 28 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 10135
Tensile Capacity of Adhesive Anchors in Damaged Masonry
In Europe, the qualification of injection anchors in masonry under static and quasi-static actions is based on an assessment of tests performed in undamaged masonry. Nevertheless, in seismic prone countries like Italy the influences deriving from earthquake actions cannot be disregarded. Masonry elements are very sensitive to cyclic/seismic action and research on the behavior of anchors in damaged masonry is rather limited. The paper presents the results of an experimental campaign aimed at evaluating the residual tensile strength of adhesive anchors installed into undamaged walls that were subsequently subjected to cyclic in-plane loading to simulate seismic actions before. Consequently, the anchors experienced different stresses depending on their location within the walls. Overall, 29 tests were performed with anchors placed both, in undamaged and damaged areas. The results showed that there is a correlation between residual tensile strength and masonry initial conditions, and therefore the installation of anchors in masonry elements should be carefully planned avoiding areas that could be heavily damaged during seismic events or considering redundant connections in critical areas. In particular, it seems that the width of the crack (created by cyclic actions) that passes nearby/into the anchor borehole is the main parameter that affects the ultimate resistance of the anchors.
- 28 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 10135
Open AccessTensile Capacity of Adhesive Anchors in Damaged Masonry
In Europe, the qualification of injection anchors in masonry under static and quasi-static actions is based on an assessment of tests performed in undamaged masonry. Nevertheless, in seismic prone countries like Italy the influences deriving from earthquake actions cannot be disregarded. Masonry elements are very sensitive to cyclic/seismic action and research on the behavior of anchors in damaged masonry is rather limited. The paper presents the results of an experimental campaign aimed at evaluating the residual tensile strength of adhesive anchors installed into undamaged walls that were subsequently subjected to cyclic in-plane loading to simulate seismic actions before. Consequently, the anchors experienced different stresses depending on their location within the walls. Overall, 29 tests were performed with anchors placed both, in undamaged and damaged areas. The results showed that there is a correlation between residual tensile strength and masonry initial conditions, and therefore the installation of anchors in masonry elements should be carefully planned avoiding areas that could be heavily damaged during seismic events or considering redundant connections in critical areas. In particular, it seems that the width of the crack (created by cyclic actions) that passes nearby/into the anchor borehole is the main parameter that affects the ultimate resistance of the anchors.