Averal Kandala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Averal Kandala has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Youngho Seo
Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA 94107, USA
2 shared publications- Ali Darvishian
Center for Wireless Integrated MicroSensing and Systems, University of Michigan, Ann Arbor, MI, USA
1 shared publication Ali M. Niknejad
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, CA 94720, USA
1 shared publicationAli Niknejad
Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
1 shared publicationHenry F. VanBrocklin
Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA 94107, USA
1 shared publicationJoseph E. Blecha
Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA 94107, USA
1 shared publication
Latest Publications
- Open Access
- 21 December 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 247, 115956
Low cost, high temporal resolution optical fiber-based γ-photon sensor for real-time pre-clinical evaluation of cancer-targeting radiopharmaceuticals
- 21 December 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 247, 115956
Open AccessLow cost, high temporal resolution optical fiber-based γ-photon sensor for real-time pre-clinical evaluation of cancer-targeting radiopharmaceuticals
- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (11) , 3362-3370
A Method and Analysis to Enable Efficient Piezoelectric Transducer-Based Ultrasonic Power and Data Links for Miniaturized Implantable Medical Devices
Acoustic links for implantable medical devices (implants) have gained attention primarily because they provide a route to wireless deep-tissue systems. The miniaturization of the implants is a key research goal in these efforts, nominally because smaller implants result in less acute tissue damage. Implant size in most acoustic systems is limited by the piezoelectric bulk crystal used for power harvesting and data communication. Further miniaturization of the piezocrystal can degrade system power transfer efficiency and data transfer reliability. Here, we present a new method for packaging the implant piezocrystal; the method maximizes power transfer efficiency ($\eta $ ) from the acoustic power at the piezo surface to the power delivered to the electrical load and information transfer across the acoustic link. Our method relies on placing piezo-to-substrate anchors to the piezo regions where the vibrational displacement of the mode of interest is zero. To evaluate our method, we investigated packaged$1\times 1\times1$ mm 3 piezocrystals assembled with different sized anchors. Our results show that reducing the anchor size decreases anchor loss and thus improves piezo quality factor ( Q ). We also demonstrate that this method improves system electromechanical coupling. A strongly coupled, high- Q piezo with properly sized and located anchors is demonstrated to achieve significantly higher$\eta$ and superior data transfer capability at resonance. Overall, this work provides an analysis and generic method for packaging the implant piezocrystal that enables the design of efficient acoustic power and data links, which provides a path toward the further miniaturization of ultrasonic implants to submillimeter scales.- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (11) , 3362-3370
A Method and Analysis to Enable Efficient Piezoelectric Transducer-Based Ultrasonic Power and Data Links for Miniaturized Implantable Medical Devices
Acoustic links for implantable medical devices (implants) have gained attention primarily because they provide a route to wireless deep-tissue systems. The miniaturization of the implants is a key research goal in these efforts, nominally because smaller implants result in less acute tissue damage. Implant size in most acoustic systems is limited by the piezoelectric bulk crystal used for power harvesting and data communication. Further miniaturization of the piezocrystal can degrade system power transfer efficiency and data transfer reliability. Here, we present a new method for packaging the implant piezocrystal; the method maximizes power transfer efficiency ($\eta $ ) from the acoustic power at the piezo surface to the power delivered to the electrical load and information transfer across the acoustic link. Our method relies on placing piezo-to-substrate anchors to the piezo regions where the vibrational displacement of the mode of interest is zero. To evaluate our method, we investigated packaged$1\times 1\times1$ mm 3 piezocrystals assembled with different sized anchors. Our results show that reducing the anchor size decreases anchor loss and thus improves piezo quality factor ( Q ). We also demonstrate that this method improves system electromechanical coupling. A strongly coupled, high- Q piezo with properly sized and located anchors is demonstrated to achieve significantly higher$\eta$ and superior data transfer capability at resonance. Overall, this work provides an analysis and generic method for packaging the implant piezocrystal that enables the design of efficient acoustic power and data links, which provides a path toward the further miniaturization of ultrasonic implants to submillimeter scales.