Irfan Ali Channa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Irfan Ali Channa has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Mohsin Ali Koondhar
Department of Electrical Engineering Quaid‐e‐Awam University of Engineering, Science and Technology Nawabshah Sindh Pakistan
4 shared publications - Dazi Li
College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
3 shared publications - Fida Hussain Dahri
School of Computer Science and Engineering, Southeast University, Nanjing 211189, China
2 shared publications - Abdul Khalique Junejo
Interdisciplinary Research Center for Sustainable Energy Systems (IRC-SES), King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia
1 shared publication - Abdul Sami Channa
Department of Chemical Engineering, Quaid-e-Awam University of Engineering, Science and Technology (QUEST), Nawabshah 67480, Pakistan
1 shared publication Dazi Li
1 shared publication
Latest Publications
- Open Access
- 10 February 2025
- Published by Institute of Central Computation and Knowledge Inc. in ICCK Transactions on Sensing, Communication, and Control
- Vol. 2 (1) , 1-10
High-Voltage Power Supply: Design Considerations and Optimization Techniques
The main goal of this study is to design and develop a half-bridge inverter architecture specifically for high-voltage power supply applications. An effective, small, and affordable system that converts direct current (DC) to alternating current(AC) can be built, thanks to the IR2151 chip’s dependable characteristics and performance. To get the desired output voltage, the transformer first increases the voltage and then the voltage is increased with a voltage-doubling rectifier (VDR) circuit. The study emphasizes how crucial it is to choose components carefully and simulate the circuit design and implementation process to guarantee dependable performance. The experimental results validate the suggested architecture’s operational efficacy and viability. Moreover, the system’s control mechanisms are strengthened by integrating Fractional Order PID (FOPID) and Proportional-Integral-Derivative (PID) controllers. These controllers provide vital feedback for stable output voltage and improved flexibility under transient situations. This study significantly advances the field by addressing key challenges such as size reduction, cost optimization, and improved control strategies, which are critical for high-voltage applications.
- 10 February 2025
- Published by Institute of Central Computation and Knowledge Inc. in ICCK Transactions on Sensing, Communication, and Control
- Vol. 2 (1) , 1-10
Open AccessHigh-Voltage Power Supply: Design Considerations and Optimization Techniques
The main goal of this study is to design and develop a half-bridge inverter architecture specifically for high-voltage power supply applications. An effective, small, and affordable system that converts direct current (DC) to alternating current(AC) can be built, thanks to the IR2151 chip’s dependable characteristics and performance. To get the desired output voltage, the transformer first increases the voltage and then the voltage is increased with a voltage-doubling rectifier (VDR) circuit. The study emphasizes how crucial it is to choose components carefully and simulate the circuit design and implementation process to guarantee dependable performance. The experimental results validate the suggested architecture’s operational efficacy and viability. Moreover, the system’s control mechanisms are strengthened by integrating Fractional Order PID (FOPID) and Proportional-Integral-Derivative (PID) controllers. These controllers provide vital feedback for stable output voltage and improved flexibility under transient situations. This study significantly advances the field by addressing key challenges such as size reduction, cost optimization, and improved control strategies, which are critical for high-voltage applications.
- Open Access
- 10 September 2024
- Published by Wiley in International Transactions on Electrical Energy Systems
An Improved Machine Learning‐Based Model for Detecting and Classifying PQDs with High Noise Immunity in Renewable‐Integrated Microgrids
Recently, renewable energy sources integrated with microgrid (MG) networks have provided safe, secure, and reliable power supply to both utility and industrial purposes. Power quality disturbances (PQDs) seriously afect the performance of MG networks and reduce the lifecycle of numerous sensitive devices in MG networks. Hence, this paper presents a new approach to detect and classify the PQDs using discrete wavelet transform, multiresolution analysis, and optimized-kernel support vector machine. Te obtained unique features from DWT-MRA are fed to train the well-known intelligent classifers. In the optimizedkernel SVM model, computing power is enhanced for classifying multiple PQ events based on the local density and leave-one-out (LOO) algorithm. To get higher separation in feature space, the kernel width of each sample is estimated based on the local density. By using the LOO method, an improved grid search strategy is implemented to get the penalty parameter to achieve satisfactory results. Moreover, a typical MG network is simulated in MATLAB software considering the validation of the proposed technique to address the power quality issues in MG networks, and the results of the proposed method are compared with other conventional ML classifers. Te simulation results confrm that the proposed method is more efective and accurate than other intelligent classifers.
- 10 September 2024
- Published by Wiley in International Transactions on Electrical Energy Systems
Open AccessAn Improved Machine Learning‐Based Model for Detecting and Classifying PQDs with High Noise Immunity in Renewable‐Integrated Microgrids
Recently, renewable energy sources integrated with microgrid (MG) networks have provided safe, secure, and reliable power supply to both utility and industrial purposes. Power quality disturbances (PQDs) seriously afect the performance of MG networks and reduce the lifecycle of numerous sensitive devices in MG networks. Hence, this paper presents a new approach to detect and classify the PQDs using discrete wavelet transform, multiresolution analysis, and optimized-kernel support vector machine. Te obtained unique features from DWT-MRA are fed to train the well-known intelligent classifers. In the optimizedkernel SVM model, computing power is enhanced for classifying multiple PQ events based on the local density and leave-one-out (LOO) algorithm. To get higher separation in feature space, the kernel width of each sample is estimated based on the local density. By using the LOO method, an improved grid search strategy is implemented to get the penalty parameter to achieve satisfactory results. Moreover, a typical MG network is simulated in MATLAB software considering the validation of the proposed technique to address the power quality issues in MG networks, and the results of the proposed method are compared with other conventional ML classifers. Te simulation results confrm that the proposed method is more efective and accurate than other intelligent classifers.
- 20 December 2023
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 52 (19) , 3175-3188
Evolutionary and Swarm Based Optimization of Fit k -Nearest Neighbor Classifier for Classification of Power Quality Disturbances
- 20 December 2023
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 52 (19) , 3175-3188
Evolutionary and Swarm Based Optimization of Fit k -Nearest Neighbor Classifier for Classification of Power Quality Disturbances
- Open Access
- 8 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 461-466
Detection and classification of power quality disturbances using STFT and deep neural Network
- 8 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 461-466
Open AccessDetection and classification of power quality disturbances using STFT and deep neural Network
- Open Access
- 21 September 2021
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 83 (6) , 1-17
TEMPERATURE AND IRRADIANCE BASED ANALYSIS THE SPECIFIC VARIATION OF PV MODULE
The effect of irradiance and increase of temperature on the back surface of the PV module would decrease the standardized efficiency of PV. To overcome this problem observed results of solar module (ORSM) and Newton Raphson’s (iterative) methods have been proposed in this research. This article compares ORSM and iterative methods of changing the specifications of a single diode model (SDM) extracted from a PV module beneath standard test conditions (STC) to calculate irradiance and various operating conditions. To make this comparison, the exact value of each diode parameter on the STC is essential. These are achieved by accepted algebraic values and iterative techniques. Newton Raphson’s technique has been proven to be the mainly precise method to find these specifications in STC. Therefore, these specifications are used to different techniques that change the parameters of an SDM with radiation and temperature. The MATLAB model is designed to assess the conducting of individual techniques by PVM. The results are compared with the measured data, and the accuracy of photovoltaic module efficiency has been achieved through different technologies at different temperature and insolation levels.
- 21 September 2021
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 83 (6) , 1-17
Open AccessTEMPERATURE AND IRRADIANCE BASED ANALYSIS THE SPECIFIC VARIATION OF PV MODULE
The effect of irradiance and increase of temperature on the back surface of the PV module would decrease the standardized efficiency of PV. To overcome this problem observed results of solar module (ORSM) and Newton Raphson’s (iterative) methods have been proposed in this research. This article compares ORSM and iterative methods of changing the specifications of a single diode model (SDM) extracted from a PV module beneath standard test conditions (STC) to calculate irradiance and various operating conditions. To make this comparison, the exact value of each diode parameter on the STC is essential. These are achieved by accepted algebraic values and iterative techniques. Newton Raphson’s technique has been proven to be the mainly precise method to find these specifications in STC. Therefore, these specifications are used to different techniques that change the parameters of an SDM with radiation and temperature. The MATLAB model is designed to assess the conducting of individual techniques by PVM. The results are compared with the measured data, and the accuracy of photovoltaic module efficiency has been achieved through different technologies at different temperature and insolation levels.
- Open Access
- 8 June 2021
- Published by Balochistan University of Information Technology, Engineering and Management Sciences in Journal of Applied and Emerging Sciences
- Vol. 11 (1) , pp 11-17
"Simulation and Analysis of Active Power Filter for Mitigation of Power Quality Problems in a Wind Based Distributed Generation"
"Simulation and Analysis of Active Power Filter for Mitigation of Power Quality Problems in a Wind Based Distributed Generation"
- 8 June 2021
- Published by Balochistan University of Information Technology, Engineering and Management Sciences in Journal of Applied and Emerging Sciences
- Vol. 11 (1) , pp 11-17
Open Access"Simulation and Analysis of Active Power Filter for Mitigation of Power Quality Problems in a Wind Based Distributed Generation"
"Simulation and Analysis of Active Power Filter for Mitigation of Power Quality Problems in a Wind Based Distributed Generation"
- Open Access
- 11 April 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (2) , 6949-6955
Classification of Voltage Sag Propagation under Double Line to Ground Fault on a Low Voltage Distribution Power Network
The key issue of the voltage-sag propagation on the different types of winding connections for the low voltage transformer in the distribution power network is considered in this study. The issues of voltage sag propagation depend upon the type of asymmetrical fault and the connection of the transformer windings. In this paper, the double line to ground fault is adopted for the voltage sag characterization. The depiction of the sage propagation is an outcome of the zero sequence components. Voltage sag propagation detection can be used to improve the power quality of the system. The obtained results reveal the characteristics of the voltage drop propagation from the primary to the secondary winding of the transformer throughout different connection. The implemented method will help analyze the Power Quality (PQ) problem in terms of voltage sag of the distributed transmission networks of the power system.
- 11 April 2021
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 11 (2) , 6949-6955
Open AccessClassification of Voltage Sag Propagation under Double Line to Ground Fault on a Low Voltage Distribution Power Network
The key issue of the voltage-sag propagation on the different types of winding connections for the low voltage transformer in the distribution power network is considered in this study. The issues of voltage sag propagation depend upon the type of asymmetrical fault and the connection of the transformer windings. In this paper, the double line to ground fault is adopted for the voltage sag characterization. The depiction of the sage propagation is an outcome of the zero sequence components. Voltage sag propagation detection can be used to improve the power quality of the system. The obtained results reveal the characteristics of the voltage drop propagation from the primary to the secondary winding of the transformer throughout different connection. The implemented method will help analyze the Power Quality (PQ) problem in terms of voltage sag of the distributed transmission networks of the power system.