Emma Reznick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Emma Reznick has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Robert Demoss Gregg
Department of Robotics, University of Michigan, Ann Arbor, MI, USA
6 shared publications - Cara Welker
University of Colorado Boulder
2 shared publications - Toby Elery
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080
2 shared publications - Edgar Bolívar-Nieto
Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA
1 shared publication - Karen J. McCain
School of Health Professions, UT Southwestern Medical Center, Dallas, TX 75390
1 shared publication Kyle R. Embry
University of Texas at Dallas, Department of Mechanical Engineering, Richardson, USA
1 shared publication
Latest Publications
- Open Access
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 13, 227-236
A Clinical Tuning Framework for Continuous Kinematic and Impedance Control of a Powered Knee-Ankle Prosthesis
Objective: Configuring a prosthetic leg is an integral part of the fitting process, but the personalization of a multi-modal powered knee-ankle prosthesis is often too complex to realize in a clinical environment. This paper develops both the technical means to individualize a hybrid kinematic-impedance controller for variable-incline walking and sit-stand transitions, and an intuitive Clinical Tuning Interface (CTI) that allows prosthetists to directly modify the controller behavior. Methods and procedures: Utilizing an established method for predicting kinematic gait individuality alongside a new parallel approach for kinetic individuality, we personalize continuous-phase/task models of joint impedance (during stance) and kinematics (during swing) using tuned characteristics exclusively from level-ground walking. To take advantage of this method, we developed a CTI that translates common clinical tuning parameters into model adjustments for the walking and sit-stand controllers. We then conducted a case study where a prosthetist iteratively tuned the powered prosthesis to an above-knee amputee participant in a simulated clinical session involving sit-stand transitions and level walking, from which incline/decline walking features were automatically calibrated. Results: The prosthetist fully tuned the multi-activity prosthesis controller in under 20 min. Each iteration of tuning (i.e., observation, parameter adjustment, and model reprocessing) took 2 min on average for walking and 1 min on average for sit-stand. The tuned behavior changes were appropriately manifested in the commanded prosthesis torques, both at the manually tuned tasks and automatically tuned tasks (inclines). Conclusion: The CTI leveraged able-bodied trends to efficiently personalize a wide array of walking tasks and sit-stand transitions, demonstrating the efficiency necessary for powered knee-ankle prostheses to become clinically viable. Clinical impact: This paper introduces a clinical tuning interface that simplifies the tuning process for multimodal robotic prosthetic legs, reducing the time required from several hours to just 20 minutes thus improving clinical feasibility.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 13, 227-236
Open AccessA Clinical Tuning Framework for Continuous Kinematic and Impedance Control of a Powered Knee-Ankle Prosthesis
Objective: Configuring a prosthetic leg is an integral part of the fitting process, but the personalization of a multi-modal powered knee-ankle prosthesis is often too complex to realize in a clinical environment. This paper develops both the technical means to individualize a hybrid kinematic-impedance controller for variable-incline walking and sit-stand transitions, and an intuitive Clinical Tuning Interface (CTI) that allows prosthetists to directly modify the controller behavior. Methods and procedures: Utilizing an established method for predicting kinematic gait individuality alongside a new parallel approach for kinetic individuality, we personalize continuous-phase/task models of joint impedance (during stance) and kinematics (during swing) using tuned characteristics exclusively from level-ground walking. To take advantage of this method, we developed a CTI that translates common clinical tuning parameters into model adjustments for the walking and sit-stand controllers. We then conducted a case study where a prosthetist iteratively tuned the powered prosthesis to an above-knee amputee participant in a simulated clinical session involving sit-stand transitions and level walking, from which incline/decline walking features were automatically calibrated. Results: The prosthetist fully tuned the multi-activity prosthesis controller in under 20 min. Each iteration of tuning (i.e., observation, parameter adjustment, and model reprocessing) took 2 min on average for walking and 1 min on average for sit-stand. The tuned behavior changes were appropriately manifested in the commanded prosthesis torques, both at the manually tuned tasks and automatically tuned tasks (inclines). Conclusion: The CTI leveraged able-bodied trends to efficiently personalize a wide array of walking tasks and sit-stand transitions, demonstrating the efficiency necessary for powered knee-ankle prostheses to become clinically viable. Clinical impact: This paper introduces a clinical tuning interface that simplifies the tuning process for multimodal robotic prosthetic legs, reducing the time required from several hours to just 20 minutes thus improving clinical feasibility.
- Open Access
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 3, 211-217
Predicting Individualized Joint Kinematics Over Continuous Variations of Walking, Running, and Stair Climbing
GOAL: Accounting for gait individuality is important to positive outcomes with wearable robots, but manually tuning multi-activity models is time-consuming and not viable in a clinic. Generalizations can possibly be made to predict gait individuality in unobserved conditions. METHODS: Kinematic individuality—how one person's joint angles differ from the group—is quantified for every subject, joint, ambulation mode (walking, running, stair ascent, and stair descent), and intramodal task (speed, incline) in an open-access dataset with 10 able-bodied subjects. Four N-way ANOVAs test how prediction methods affect the fit to experimental data between and within ambulation modes. We test whether walking individuality (measured at a single speed on level ground) carries across modes, or whether a mode-specific prediction (based on a single task for each mode) is significantly more effective. RESULTS: Kinematic individualization improves fit across joint and task if we consider each mode separately. Across all modes, tasks, and joints, modal individualization improved the fit in 81% of trials, improving the fit on average by 4.3 $^\circ$ across the gait cycle. This was statistically significant at all joints for walking and running, and half the joints for stair ascent/descent. CONCLUSIONS: For walking and running, kinematic individuality can be easily generalized within mode, but the trends are mixed on stairs depending on joint.
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 3, 211-217
Open AccessPredicting Individualized Joint Kinematics Over Continuous Variations of Walking, Running, and Stair Climbing
GOAL: Accounting for gait individuality is important to positive outcomes with wearable robots, but manually tuning multi-activity models is time-consuming and not viable in a clinic. Generalizations can possibly be made to predict gait individuality in unobserved conditions. METHODS: Kinematic individuality—how one person's joint angles differ from the group—is quantified for every subject, joint, ambulation mode (walking, running, stair ascent, and stair descent), and intramodal task (speed, incline) in an open-access dataset with 10 able-bodied subjects. Four N-way ANOVAs test how prediction methods affect the fit to experimental data between and within ambulation modes. We test whether walking individuality (measured at a single speed on level ground) carries across modes, or whether a mode-specific prediction (based on a single task for each mode) is significantly more effective. RESULTS: Kinematic individualization improves fit across joint and task if we consider each mode separately. Across all modes, tasks, and joints, modal individualization improved the fit in 81% of trials, improving the fit on average by 4.3 $^\circ$ across the gait cycle. This was statistically significant at all joints for walking and running, and half the joints for stair ascent/descent. CONCLUSIONS: For walking and running, kinematic individuality can be easily generalized within mode, but the trends are mixed on stairs depending on joint.
- Open Access
- 30 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Predicting Individualized Joint Kinematics over Continuous Variations of Walking, Running, and Stair Climbing
GOAL: Accounting for gait individuality is important to positive outcomes with wearable robots, but tuning multi-activity models is time-consuming and not viable in a clinic. Generalizations can be made to predict gait individuality in unobserved conditions. METHODS: Kinematic individuality—how one person’s joint angles differ from the group—is quantified for every subject, joint, ambulation mode (walking, running, stair ascent, and stair descent), and intramodal task (speed, incline) in an open-source able-bodied dataset. Four N-way ANOVAs test how prediction methods affect the fit to experimental data between and within ambulation modes. We test whether walking individuality carries across modes, or whether a modal prediction is more effective against average kinematics. RESULTS: Kinematic individualization improves fit across joint and task if we consider each mode separately. Across all modes, tasks, and joints, individualization improved the fit in 81% of trials, improving the fit on average by 4.3º across the gait cycle. This was statistically significant at all joints for walking and running, and half the joints for stair ascent/descent. CONCLUSIONS: Kinematic individualization tends to improve fit across all joints and can be easily predicted by observing only one task within an ambulation mode.
- 30 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessPredicting Individualized Joint Kinematics over Continuous Variations of Walking, Running, and Stair Climbing
GOAL: Accounting for gait individuality is important to positive outcomes with wearable robots, but tuning multi-activity models is time-consuming and not viable in a clinic. Generalizations can be made to predict gait individuality in unobserved conditions. METHODS: Kinematic individuality—how one person’s joint angles differ from the group—is quantified for every subject, joint, ambulation mode (walking, running, stair ascent, and stair descent), and intramodal task (speed, incline) in an open-source able-bodied dataset. Four N-way ANOVAs test how prediction methods affect the fit to experimental data between and within ambulation modes. We test whether walking individuality carries across modes, or whether a modal prediction is more effective against average kinematics. RESULTS: Kinematic individualization improves fit across joint and task if we consider each mode separately. Across all modes, tasks, and joints, individualization improved the fit in 81% of trials, improving the fit on average by 4.3º across the gait cycle. This was statistically significant at all joints for walking and running, and half the joints for stair ascent/descent. CONCLUSIONS: Kinematic individualization tends to improve fit across all joints and can be easily predicted by observing only one task within an ambulation mode.
- 3 February 2022
- Published by ASME International in Journal of Medical Devices
- Vol. 16 (2)
Design and Initial Validation of a Multiple Degree-of-Freedom Joint for an Ankle-Foot Orthosis
This paper presents the novel design of a multi-degree-of-freedom joint (M-DOF) for an ankle-foot orthosis (AFO) that aims to improve upon the commercially available double action joint (DAJ). The M-DOF is designed to maintain the functionality of the DAJ, while increasing dorsiflexion stiffness and introducing inversion/eversion. This increase in range of motion is designed to produce greater engagement from lower limb muscles during gait. The M-DOF was experimentally validated with one able-bodied and one stroke subject. Across walking speeds, the M-DOF AFO minimally affected the able-bodied subject's joint kinematics. The stroke subject's ankle dorsiflexion/plantarflexion and knee flexion were not heavily altered when wearing the M-DOF AFO, compared to the DAJ AFO. The new DOF allowed by the M-DOF AFO increased the inversion/eversion of the ankle by ∼3 deg, without introducing any new compensations compared to their gait with the DAJ AFO.
- 3 February 2022
- Published by ASME International in Journal of Medical Devices
- Vol. 16 (2)
Design and Initial Validation of a Multiple Degree-of-Freedom Joint for an Ankle-Foot Orthosis
This paper presents the novel design of a multi-degree-of-freedom joint (M-DOF) for an ankle-foot orthosis (AFO) that aims to improve upon the commercially available double action joint (DAJ). The M-DOF is designed to maintain the functionality of the DAJ, while increasing dorsiflexion stiffness and introducing inversion/eversion. This increase in range of motion is designed to produce greater engagement from lower limb muscles during gait. The M-DOF was experimentally validated with one able-bodied and one stroke subject. Across walking speeds, the M-DOF AFO minimally affected the able-bodied subject's joint kinematics. The stroke subject's ankle dorsiflexion/plantarflexion and knee flexion were not heavily altered when wearing the M-DOF AFO, compared to the DAJ AFO. The new DOF allowed by the M-DOF AFO increased the inversion/eversion of the ankle by ∼3 deg, without introducing any new compensations compared to their gait with the DAJ AFO.
- Top Cited PapersOpen Access
- 28 October 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-12
Lower-limb kinematics and kinetics during continuously varying human locomotion
Human locomotion involves continuously variable activities including walking, running, and stair climbing over a range of speeds and inclinations as well as sit-stand, walk-run, and walk-stairs transitions. Understanding the kinematics and kinetics of the lower limbs during continuously varying locomotion is fundamental to developing robotic prostheses and exoskeletons that assist in community ambulation. However, available datasets on human locomotion neglect transitions between activities and/or continuous variations in speed and inclination during these activities. This data paper reports a new dataset that includes the lower-limb kinematics and kinetics of ten able-bodied participants walking at multiple inclines (±0°; 5° and 10°) and speeds (0.8 m/s; 1 m/s; 1.2 m/s), running at multiple speeds (1.8 m/s; 2 m/s; 2.2 m/s and 2.4 m/s), walking and running with constant acceleration (±0.2; 0.5), and stair ascent/descent with multiple stair inclines (20°; 25°; 30° and 35°). This dataset also includes sit-stand transitions, walk-run transitions, and walk-stairs transitions. Data were recorded by a Vicon motion capture system and, for applicable tasks, a Bertec instrumented treadmill.
- 28 October 2021
- Published by Springer Nature in Scientific Data
- Vol. 8 (1) , 1-12
Top Cited PapersOpen AccessLower-limb kinematics and kinetics during continuously varying human locomotion
Human locomotion involves continuously variable activities including walking, running, and stair climbing over a range of speeds and inclinations as well as sit-stand, walk-run, and walk-stairs transitions. Understanding the kinematics and kinetics of the lower limbs during continuously varying locomotion is fundamental to developing robotic prostheses and exoskeletons that assist in community ambulation. However, available datasets on human locomotion neglect transitions between activities and/or continuous variations in speed and inclination during these activities. This data paper reports a new dataset that includes the lower-limb kinematics and kinetics of ten able-bodied participants walking at multiple inclines (±0°; 5° and 10°) and speeds (0.8 m/s; 1 m/s; 1.2 m/s), running at multiple speeds (1.8 m/s; 2 m/s; 2.2 m/s and 2.4 m/s), walking and running with constant acceleration (±0.2; 0.5), and stair ascent/descent with multiple stair inclines (20°; 25°; 30° and 35°). This dataset also includes sit-stand transitions, walk-run transitions, and walk-stairs transitions. Data were recorded by a Vicon motion capture system and, for applicable tasks, a Bertec instrumented treadmill.
- Open Access
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (12) , 2944-2954
Effects of a Powered Knee-Ankle Prosthesis on Amputee Hip Compensations: A Case Series
Transfemoral amputee gait often exhibits compensations due to the lack of ankle push-off power and control over swing foot position using passive prostheses. Powered prostheses can restore this functionality, but their effects on compensatory behaviors, specifically at the residual hip, are not well understood. This paper investigates residual hip compensations through walking experiments with three transfemoral amputees using a low-impedance powered knee-ankle prosthesis compared to their day-to-day passive prosthesis. The powered prosthesis used impedance control during stance for compliant interaction with the ground, a time-based push-off controller to deliver high torque and power, and phase-based trajectory tracking during swing to provide user control over foot placement. Experiments show that when subjects utilized the powered ankle push-off, less mechanical pull-off power was required from the residual hip to progress the limb forward. Overall positive work at the residual hip was reduced for 2 of 3 subjects, and negative work was reduced for all subjects. Moreover, all subjects displayed increased step length, increased propulsive impulses on the prosthetic side, and improved impulse symmetries. Hip circumduction improved for subjects who had previously exhibited this compensation on their passive prosthesis. These improvements in gait, especially reduced residual hip power and work, have the potential to reduce fatigue and overuse injuries in persons with transfemoral amputation.
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (12) , 2944-2954
Open AccessEffects of a Powered Knee-Ankle Prosthesis on Amputee Hip Compensations: A Case Series
Transfemoral amputee gait often exhibits compensations due to the lack of ankle push-off power and control over swing foot position using passive prostheses. Powered prostheses can restore this functionality, but their effects on compensatory behaviors, specifically at the residual hip, are not well understood. This paper investigates residual hip compensations through walking experiments with three transfemoral amputees using a low-impedance powered knee-ankle prosthesis compared to their day-to-day passive prosthesis. The powered prosthesis used impedance control during stance for compliant interaction with the ground, a time-based push-off controller to deliver high torque and power, and phase-based trajectory tracking during swing to provide user control over foot placement. Experiments show that when subjects utilized the powered ankle push-off, less mechanical pull-off power was required from the residual hip to progress the limb forward. Overall positive work at the residual hip was reduced for 2 of 3 subjects, and negative work was reduced for all subjects. Moreover, all subjects displayed increased step length, increased propulsive impulses on the prosthetic side, and improved impulse symmetries. Hip circumduction improved for subjects who had previously exhibited this compensation on their passive prosthesis. These improvements in gait, especially reduced residual hip power and work, have the potential to reduce fatigue and overuse injuries in persons with transfemoral amputation.