Kenan Dagdelen
Kenan Dagdelen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Omer Ersin Muz
Yunus Emre State Hospital, Ophthalmology Clinic
2 shared publications Emrah Dirican
Department of Ophthalmology, Konya Training and Research Hospital, Konya 42090, Turkey
1 shared publication- Emrah Dirican
Department of Ophthalmology, Konya City Hospital, Konya, Turkey
1 shared publication - Merve Ekici
Beytepe Murat Erdi Eker State Hospital, Turkey
1 shared publication - Mete Güler
Özel Hatem Hastanesi, Göz Hastalıkları Kliniği
1 shared publication - Tuncay Pirdal
Department of Ophthalmology, Ordu State Hospital, Altınordu, Turkey
1 shared publication
Latest Publications
- Open Access
- 4 April 2024
- Published by Osmangazi Journal of Medicine in OSMANGAZİ JOURNAL OF MEDICINE
Demonstrationof CicatricialStagewith Optical CoherenceTomography in A Child with Best VitelliformMacularDystrophy
Best vitelliform macular dystrophy (BVMD) is a rare hereditary macular dystrophy. Various staging systems are performed in the clinical evaluation of BVMD. In this case report, it is aimed to demonstrate the presence of cicatricial stage in a 9-year-old boy. A 9-year-old boy was applied to our Eskisehir YunusEmre State Hospital OphthalmologyClinic with decreased visual acuity in his right eye. When the family history of the patient was questioned, it was learned that the other family members were also followed in another center due to loss of vision. BMVD diagnosis was confirmed by using electrophysiological tests and additional clinical studies. In optical coherence tomography, a hyporeflective lesion consistent with subretinal fluid was observed for both eyes. Additionally, a hump-shaped subretinalhyporeflective lesion was found in the right eye. Visual acuity is generally stable in the early stages of the disease for patients with BVMD, but the presence of a visual impairment is usually thought as a sign of the development of a choroidal neovascular membrane. Although rare, however, cicatricial stage, which is observed in the advanced stages of the disease, can be seen in small children. Distinguishing choroidal neovascular membrane from the cicatricial stage is necessary especially in children due to the risk of amblyopia and to make an accurate treatment planning.
- 4 April 2024
- Published by Osmangazi Journal of Medicine in OSMANGAZİ JOURNAL OF MEDICINE
Open AccessDemonstrationof CicatricialStagewith Optical CoherenceTomography in A Child with Best VitelliformMacularDystrophy
Best vitelliform macular dystrophy (BVMD) is a rare hereditary macular dystrophy. Various staging systems are performed in the clinical evaluation of BVMD. In this case report, it is aimed to demonstrate the presence of cicatricial stage in a 9-year-old boy. A 9-year-old boy was applied to our Eskisehir YunusEmre State Hospital OphthalmologyClinic with decreased visual acuity in his right eye. When the family history of the patient was questioned, it was learned that the other family members were also followed in another center due to loss of vision. BMVD diagnosis was confirmed by using electrophysiological tests and additional clinical studies. In optical coherence tomography, a hyporeflective lesion consistent with subretinal fluid was observed for both eyes. Additionally, a hump-shaped subretinalhyporeflective lesion was found in the right eye. Visual acuity is generally stable in the early stages of the disease for patients with BVMD, but the presence of a visual impairment is usually thought as a sign of the development of a choroidal neovascular membrane. Although rare, however, cicatricial stage, which is observed in the advanced stages of the disease, can be seen in small children. Distinguishing choroidal neovascular membrane from the cicatricial stage is necessary especially in children due to the risk of amblyopia and to make an accurate treatment planning.
- 4 March 2023
- Published by Springer Nature in International Ophthalmology
- Vol. 43 (6) , 2109-2117
Optic nerve sheath diameter and axial length in patients with optic disc drusen: a cross-sectional study
Aim Measuring the optic nerve sheath diameter (ONSD) and the anteroposterior axial length of the eye in patients with optic disc drusen (ODD). Methods A total of 43 healthy volunteers and 41 patients with ODD were included in the study. The ONSD and axial length were measured in the posterior position using an ultrasound device (E-Z Scan AB5500 +) probe with a 10 MHz frequency. The ONSD was measured 3 mm behind the globe wall. Receiver operating characteristic (ROC) curve analysis was performed to determine patients with ODD using ONSD. Any p-value of < 0.05 was accepted to demonstrate significance. Results The ONSD was significantly higher (5.2 mm and 4.8 mm, p = 0.006, respectively), and the axial length was shorter (21.82 ± 2.15 mm and 23.27 ± 1.96 mm, p = 0.002, respectively) in the ODD group. The spherical equivalent was more commonly seen as hypermetropic in the ODD group (1.00 [− 0.85 to 1.75]). In the ROC analysis to determine the ONSD value in ODD diagnosis, the area under the curve was 0.6754 (95% confidence interval 0.559–0.788, p = 0.006). ONSD cutoff of 5.70 mm had a sensitivity of 0.366 and a specificity of 0.907 to diagnose ODD. Conclusion In this study, the ONSD was significantly higher in the ODD group. The axial length was shorter in the ODD group. This study is the first in the literature to evaluate the ONSD in patients with optic disc drusen. Further studies are needed in this regard.
- 4 March 2023
- Published by Springer Nature in International Ophthalmology
- Vol. 43 (6) , 2109-2117
Optic nerve sheath diameter and axial length in patients with optic disc drusen: a cross-sectional study
Aim Measuring the optic nerve sheath diameter (ONSD) and the anteroposterior axial length of the eye in patients with optic disc drusen (ODD). Methods A total of 43 healthy volunteers and 41 patients with ODD were included in the study. The ONSD and axial length were measured in the posterior position using an ultrasound device (E-Z Scan AB5500 +) probe with a 10 MHz frequency. The ONSD was measured 3 mm behind the globe wall. Receiver operating characteristic (ROC) curve analysis was performed to determine patients with ODD using ONSD. Any p-value of < 0.05 was accepted to demonstrate significance. Results The ONSD was significantly higher (5.2 mm and 4.8 mm, p = 0.006, respectively), and the axial length was shorter (21.82 ± 2.15 mm and 23.27 ± 1.96 mm, p = 0.002, respectively) in the ODD group. The spherical equivalent was more commonly seen as hypermetropic in the ODD group (1.00 [− 0.85 to 1.75]). In the ROC analysis to determine the ONSD value in ODD diagnosis, the area under the curve was 0.6754 (95% confidence interval 0.559–0.788, p = 0.006). ONSD cutoff of 5.70 mm had a sensitivity of 0.366 and a specificity of 0.907 to diagnose ODD. Conclusion In this study, the ONSD was significantly higher in the ODD group. The axial length was shorter in the ODD group. This study is the first in the literature to evaluate the ONSD in patients with optic disc drusen. Further studies are needed in this regard.
- Open Access
- 1 June 2022
- Published by FapUNIFESP (SciELO) in Arquivos de Neuro-Psiquiatria
- Vol. 80 (6) , 580-585
Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension
Background: Idiopathic intracranial hypertension (IIH) is primarily a disorder of obese young women characterized by symptoms associated with raised intracranial pressure in the absence of a space-occupying lesion. Objective: To compare the mean optic nerve sheath diameter (ONSD) measured using ultrasonography (USG) in patients with idiopathic intracranial hypertension (IIH) and normal healthy individuals. Methods: A prospective study. Ninety-seven participants aged 18-80 years were divided into two groups as patients with IIH (n=47) and the control group (n=50). The ONSD was measured using ultrasound with a 10-MHz probe. ONSD was measured 3 mm behind the optic disc. Receiver operating characteristic (ROC) curve analysis was performed to determine patients with IIH using ONSD. Results: Body mass index was higher in the IIH group compared with the control group (p=0.001). The mean ONSD was statistically significantly thicker in the IIH group (6.4 mm) than in the control group (4.90 mm). The cut-off value of ONSD in patients with IIH was measured as 5.70 mm. There was a significant negative correlation between ONSD and age (r:-0.416 and p<0.001). There was a positive correlation between BMI and ONSD (r: 0.437 and p<0.001). Conclusions: Ultrasound can be a reliable, non-invasive and rapid tool to measure ONSD in monitoring patients with IIH. After the first diagnosis of IIH, based on neuroimaging and measuring intracranial pressure using invasive methods, ONSD can be used in treatment and follow-up.
- 1 June 2022
- Published by FapUNIFESP (SciELO) in Arquivos de Neuro-Psiquiatria
- Vol. 80 (6) , 580-585
Open AccessMeasuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension
Background: Idiopathic intracranial hypertension (IIH) is primarily a disorder of obese young women characterized by symptoms associated with raised intracranial pressure in the absence of a space-occupying lesion. Objective: To compare the mean optic nerve sheath diameter (ONSD) measured using ultrasonography (USG) in patients with idiopathic intracranial hypertension (IIH) and normal healthy individuals. Methods: A prospective study. Ninety-seven participants aged 18-80 years were divided into two groups as patients with IIH (n=47) and the control group (n=50). The ONSD was measured using ultrasound with a 10-MHz probe. ONSD was measured 3 mm behind the optic disc. Receiver operating characteristic (ROC) curve analysis was performed to determine patients with IIH using ONSD. Results: Body mass index was higher in the IIH group compared with the control group (p=0.001). The mean ONSD was statistically significantly thicker in the IIH group (6.4 mm) than in the control group (4.90 mm). The cut-off value of ONSD in patients with IIH was measured as 5.70 mm. There was a significant negative correlation between ONSD and age (r:-0.416 and p<0.001). There was a positive correlation between BMI and ONSD (r: 0.437 and p<0.001). Conclusions: Ultrasound can be a reliable, non-invasive and rapid tool to measure ONSD in monitoring patients with IIH. After the first diagnosis of IIH, based on neuroimaging and measuring intracranial pressure using invasive methods, ONSD can be used in treatment and follow-up.
- 10 March 2022
- Published by Bozok Tip Dergisi in Bozok Tıp Dergisi
Management of Patients with Thyroid-Associated Ophthalmopathy: Role of Spectral Domain Optical Coherence Tomography
AIM: To demonstrate the changes in optic nerve head (ONH), retinal nerve fiber layer (RNFL) and macula in patients with thyroid-associated ophthalmopathy (TAO) by spectral domain optical coherence tomography (SD-OCT). METHODS: We included forty-one eyes of 41 patients with a diagnosis of TAO and forty-eight eyes of 48 age- and sex-matched healthy subjects (control group) from June 2016 to July 2018. The ONH parameters, RNFL and macular thicknesses in the nine macular quadrants according to ETDRS were measured with SD-OCT. Proptosis level was determined by Hertel exophthalmometer. Clinical activity score (CAS) according to the European Group of Graves' Orbitopathy (EUGOGO) guidelines was determined in all patients. RESULTS: Superior, inferior and average RNFL thicknesses were significantly lower in the TAO group compared to the control group (p < 0.05). Optic disc area was significantly larger in the TAO group. Outer quadrant macular thicknesses and average macular thickness were significantly lower in the TAO group (p < 0.05). CAS had a weak correlation with RNFL thickness and average macular thickness. CONCLUSION: Alterations in RNFL thicknesses and macular thicknesses according to ETDRS template can be detected before the development of ocular symptoms in patients with TAO. OCT is a convenient, non-invasive tool for the evaluation and follow-up of macular structural changes. Patients can be diagnosed at an early stage prior to the development of functional damage. However, the low number of studies investigating this subject and the conflicting findings of existing studies necessitate further studies.
- 10 March 2022
- Published by Bozok Tip Dergisi in Bozok Tıp Dergisi
Management of Patients with Thyroid-Associated Ophthalmopathy: Role of Spectral Domain Optical Coherence Tomography
AIM: To demonstrate the changes in optic nerve head (ONH), retinal nerve fiber layer (RNFL) and macula in patients with thyroid-associated ophthalmopathy (TAO) by spectral domain optical coherence tomography (SD-OCT). METHODS: We included forty-one eyes of 41 patients with a diagnosis of TAO and forty-eight eyes of 48 age- and sex-matched healthy subjects (control group) from June 2016 to July 2018. The ONH parameters, RNFL and macular thicknesses in the nine macular quadrants according to ETDRS were measured with SD-OCT. Proptosis level was determined by Hertel exophthalmometer. Clinical activity score (CAS) according to the European Group of Graves' Orbitopathy (EUGOGO) guidelines was determined in all patients. RESULTS: Superior, inferior and average RNFL thicknesses were significantly lower in the TAO group compared to the control group (p < 0.05). Optic disc area was significantly larger in the TAO group. Outer quadrant macular thicknesses and average macular thickness were significantly lower in the TAO group (p < 0.05). CAS had a weak correlation with RNFL thickness and average macular thickness. CONCLUSION: Alterations in RNFL thicknesses and macular thicknesses according to ETDRS template can be detected before the development of ocular symptoms in patients with TAO. OCT is a convenient, non-invasive tool for the evaluation and follow-up of macular structural changes. Patients can be diagnosed at an early stage prior to the development of functional damage. However, the low number of studies investigating this subject and the conflicting findings of existing studies necessitate further studies.
- Open Access
- 14 January 2022
- Published by Springer Nature in Research Square
Quality Assessment and Content Analysis of Youtube Videos on Trabeculectomy
PurposeThe aim of this study is to evaluate the accuracy, quality and reliability of the videos on trabeculectomy on YouTube which is an online video-sharing platform.Scope This paper aims to assess the quality and analyze the content of the videos on Trabeculectomy on YouTube. The material has been obtained by a video search carried out on the Youtube -online video platform- with the keyword “Trabeculectomy”. The material (videos) was examined and selected in accordance with the exclusion criteria (not being in English, duplicate videos, lack of title information of the video, being irrelevant to the subject, videos with only advertising content, videos with a pixel below 240, takes longer than 20 minutes). After the implementation of exclusion criteria, the first ten suitable videos were included in the evaluation.MethodologyRegarding the material, the parameters of the number of views, the number of likes, the number of dislikes, the number of comments, the video duration, the days since the video was uploaded were recorded. Thus, after carving out the secondary data, a number of statistical analyses were performed namely Shapiro-Wilks, Kruskall-Wallis, Mann-Whitney U and Backward Linear Regression. In this framework, statistical analyzes were made via using the Stata software. Statistical significance value (threshold) was accepted as %10 (pResultsAfter the videos were evaluated according to the upload source, it was found that 2 videos were downloaded by the individuals who is not a doctor, 6 videos from doctors and 2 videos from a commercial source. The number of subscribers of the YouTube channels on which these sources have been uploaded was significantly different from each other (pConclusionYouTube videos are essentially insufficient as an educational material and an English source of information for the Trabeculectomy. Health professionals need to pay more attention to online platforms so that patients can access accurate information.Categories:Medical Education, Medical Simulation, Surgery
- 14 January 2022
- Published by Springer Nature in Research Square
Open AccessQuality Assessment and Content Analysis of Youtube Videos on Trabeculectomy
PurposeThe aim of this study is to evaluate the accuracy, quality and reliability of the videos on trabeculectomy on YouTube which is an online video-sharing platform.Scope This paper aims to assess the quality and analyze the content of the videos on Trabeculectomy on YouTube. The material has been obtained by a video search carried out on the Youtube -online video platform- with the keyword “Trabeculectomy”. The material (videos) was examined and selected in accordance with the exclusion criteria (not being in English, duplicate videos, lack of title information of the video, being irrelevant to the subject, videos with only advertising content, videos with a pixel below 240, takes longer than 20 minutes). After the implementation of exclusion criteria, the first ten suitable videos were included in the evaluation.MethodologyRegarding the material, the parameters of the number of views, the number of likes, the number of dislikes, the number of comments, the video duration, the days since the video was uploaded were recorded. Thus, after carving out the secondary data, a number of statistical analyses were performed namely Shapiro-Wilks, Kruskall-Wallis, Mann-Whitney U and Backward Linear Regression. In this framework, statistical analyzes were made via using the Stata software. Statistical significance value (threshold) was accepted as %10 (pResultsAfter the videos were evaluated according to the upload source, it was found that 2 videos were downloaded by the individuals who is not a doctor, 6 videos from doctors and 2 videos from a commercial source. The number of subscribers of the YouTube channels on which these sources have been uploaded was significantly different from each other (pConclusionYouTube videos are essentially insufficient as an educational material and an English source of information for the Trabeculectomy. Health professionals need to pay more attention to online platforms so that patients can access accurate information.Categories:Medical Education, Medical Simulation, Surgery
- 14 July 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (11) , 3825-3835
Comparison of BAK-preserved latanoprost and polyquad-preserved travoprost on ocular surface parameters in patients with glaucoma and ocular hypertension
Background To compare the effect of two different prostaglandin analogues (Travatan® vs. Xalatan®) on ocular surface parameters. Methods This study includes 44 eyes of 44 patients with newly diagnosed primary open-angle glaucoma (POAG) or ocular hypertension (OHT). Patients were randomly divided into two groups and treated with either benzalkonium chloride (BAK)-preserved latanoprost and polyquad-preserved travoprost. Changes in intraocular pressure (IOP) levels and ocular surface parameters including ocular surface disease index (OSDI) questionnaire, tear breakup time (TBUT), ocular surface staining scores, and Schirmer test scores of patients were performed at baseline, 1, 3, 6, and 12 months of treatment and compared. Results The age, sex ratio, visual acuity, central corneal thickness, and cup/disc ratio were similar between the groups. A decrease in IOP levels (23.3 ± 2.5 to 15.5 ± 2.3), TBUT (5.5 ± 2.3 to 4.1 ± 1.7 s), Schirmer test values (11.3 ± 5.9 to 8.6 ± 4.7 s), and a worsening in OSDI scores (44.6 ± 15.2 to 55.1 ± 13.1) and staining scores (1.7 ± 1.6 to 2.3 ± 1.8) were observed in all patients in the first month of treatment (p < 0.05, for all). No further worsening was detected during the 1-year follow-up. There was no difference between the groups in terms of alterations in IOP levels and ocular surface parameters. Conclusion Travatan® and Xalatan® have a similar effect on IOP levels and ocular surface parameters in patients with POAG and OHT.
- 14 July 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (11) , 3825-3835
Comparison of BAK-preserved latanoprost and polyquad-preserved travoprost on ocular surface parameters in patients with glaucoma and ocular hypertension
Background To compare the effect of two different prostaglandin analogues (Travatan® vs. Xalatan®) on ocular surface parameters. Methods This study includes 44 eyes of 44 patients with newly diagnosed primary open-angle glaucoma (POAG) or ocular hypertension (OHT). Patients were randomly divided into two groups and treated with either benzalkonium chloride (BAK)-preserved latanoprost and polyquad-preserved travoprost. Changes in intraocular pressure (IOP) levels and ocular surface parameters including ocular surface disease index (OSDI) questionnaire, tear breakup time (TBUT), ocular surface staining scores, and Schirmer test scores of patients were performed at baseline, 1, 3, 6, and 12 months of treatment and compared. Results The age, sex ratio, visual acuity, central corneal thickness, and cup/disc ratio were similar between the groups. A decrease in IOP levels (23.3 ± 2.5 to 15.5 ± 2.3), TBUT (5.5 ± 2.3 to 4.1 ± 1.7 s), Schirmer test values (11.3 ± 5.9 to 8.6 ± 4.7 s), and a worsening in OSDI scores (44.6 ± 15.2 to 55.1 ± 13.1) and staining scores (1.7 ± 1.6 to 2.3 ± 1.8) were observed in all patients in the first month of treatment (p < 0.05, for all). No further worsening was detected during the 1-year follow-up. There was no difference between the groups in terms of alterations in IOP levels and ocular surface parameters. Conclusion Travatan® and Xalatan® have a similar effect on IOP levels and ocular surface parameters in patients with POAG and OHT.
- Open Access
- 18 October 2018
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 11 (10) , 1631-1637
The assessment of structural changes on optic nerve head and macula in primary open angle glaucoma and ocular hypertension
AIM: To assess morphological changes in macula, retinal nerve fiber layer (RNFL) and optic nevre head (ONH) of cases with primary open angle glaucoma (POAG) and ocular hypertension (OH) with spectral domain optic coherence tomography (OCT). METHODS: This study included 109 eyes from 62 POAG patients, 50 eyes from 30 OH patients, and 101 eyes from 53 healthy volunteers. Data gained by OCT were compared with perimetry indexes. ONH, RNFL and macula analysis were performed for all subjects. Rim area, disc area, average cup/disc (C/D) ratio, vertical C/D ratio, cup volume data were recorded during ONH analysis. Average RNFL thickness and the thickness of four quadrants (superior, inferior, nasal and temporal) was established in microns. In total, nine macular quadrants involving the foveal region mentioned in the Early Treatment Diabetic Treatment Study (ETDRS) template were measured, and average macular thickness and macular volume data were recorded during macula analysis. Differences between groups were evaluated with the one-way ANOVA test. Tukey's multiple comparison test was performed to detect difference between groups. Receiver-operating characteristic (ROC) analysis was done for early stage POAG patients to establish sensitivity and specificity of chosen parameters in early stage POAG. Area under the receiver operating characteristic (AUROC) values were calculated to compare ROC areas. RESULTS: Statistically significant differences were found in all ONH parameters, except optic disc area. Neuroretinal rim area was identified as the parameter with the highest difference between groups (F=21.72, P<0.05). The highest correlation between ONH parameters and perimetry was observed at neuroretinal rim region (r=0.487). Inferior RNFL thickness was established as the parameter with the highest difference between groups among RNFL parameters. In the mean of all glaucoma patients, the highest correlation between data handled with OCT and mean deviation was observed in RNFL thickness. Average macular thickness was detected as the parameter with the highest difference between groups among macular parameters. The highest correlation between macula parameters and perimetry indexes was observed between average macular thickness and perimetry indexes (r=0.514). CONCLUSION: Although the assessment of ONH and the analysis of macular thickness are important in diagnosis and treatment, RNFL assessment is the most valuable parameter.
- 18 October 2018
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 11 (10) , 1631-1637
Open AccessThe assessment of structural changes on optic nerve head and macula in primary open angle glaucoma and ocular hypertension
AIM: To assess morphological changes in macula, retinal nerve fiber layer (RNFL) and optic nevre head (ONH) of cases with primary open angle glaucoma (POAG) and ocular hypertension (OH) with spectral domain optic coherence tomography (OCT). METHODS: This study included 109 eyes from 62 POAG patients, 50 eyes from 30 OH patients, and 101 eyes from 53 healthy volunteers. Data gained by OCT were compared with perimetry indexes. ONH, RNFL and macula analysis were performed for all subjects. Rim area, disc area, average cup/disc (C/D) ratio, vertical C/D ratio, cup volume data were recorded during ONH analysis. Average RNFL thickness and the thickness of four quadrants (superior, inferior, nasal and temporal) was established in microns. In total, nine macular quadrants involving the foveal region mentioned in the Early Treatment Diabetic Treatment Study (ETDRS) template were measured, and average macular thickness and macular volume data were recorded during macula analysis. Differences between groups were evaluated with the one-way ANOVA test. Tukey's multiple comparison test was performed to detect difference between groups. Receiver-operating characteristic (ROC) analysis was done for early stage POAG patients to establish sensitivity and specificity of chosen parameters in early stage POAG. Area under the receiver operating characteristic (AUROC) values were calculated to compare ROC areas. RESULTS: Statistically significant differences were found in all ONH parameters, except optic disc area. Neuroretinal rim area was identified as the parameter with the highest difference between groups (F=21.72, P<0.05). The highest correlation between ONH parameters and perimetry was observed at neuroretinal rim region (r=0.487). Inferior RNFL thickness was established as the parameter with the highest difference between groups among RNFL parameters. In the mean of all glaucoma patients, the highest correlation between data handled with OCT and mean deviation was observed in RNFL thickness. Average macular thickness was detected as the parameter with the highest difference between groups among macular parameters. The highest correlation between macula parameters and perimetry indexes was observed between average macular thickness and perimetry indexes (r=0.514). CONCLUSION: Although the assessment of ONH and the analysis of macular thickness are important in diagnosis and treatment, RNFL assessment is the most valuable parameter.