Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cenk Demirkir has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental investigation on damage-induced changes in modal parameters of cross-laminated timber panels

    by Ahmet Can Altunışık, Ahmet Can, Hasan Öztürk, Fezayil Sunca, Fatih Yesevi Okur, Algıhan Kaşif Karahasan, Aydın Demir, Okan İlhan, Abdullah Uğur Birinci, Nadir Ayrilmis, et al.

  • Open Access

    Influence of Ambient Vibration and Monotonic Loading on FEM Updating of Cross-Laminated Timber (CLT) Panels Used in the Building Industry

    by Ahmet Can Altunişik, Aydın Demir, Fatih Yesevi Okur, Algıhan Kaşif Karahasan, Fezayil Sunca, Okan İlhan, Abdullah Uğur Birinci, Hasan Öztürk, Nadir Ayrilmis, Cenk Demirkir

    Cross-laminated timber (CLT) is recognized as a leading engineered wood product because of its sustainability, reduced carbon footprint, and growing application in civil engineering structures. However, the numerical modeling of CLT systems is challenging due to numerous connection details and the lack of standardized models. This study evaluates the effect of different types of experimental data on the finite element model (FEM) updating process for CLT panels. To this end, 30 CLT panels with varying configurations were subjected to monotonic loading to characterize their load–displacement responses, and ambient vibration tests were conducted to identify their dynamic characteristics. Initial FEMs of the CLT panels were developed and then updated using three different approaches: displacement-based, frequency-based, and a combined method. The results indicated that updating based solely on displacement data accurately captures static responses but fails to adequately represent modal behavior. In contrast, frequency-based updating yielded reliable natural frequencies but resulted in significant discrepancies in displacement predictions. The combined updating method provided consistent results, reducing displacement differences to 0–14.29% with an average of 3.23%, while maintaining frequency discrepancies below 5%. Overall, the results show that obtaining a reliable numerical model of CLT systems requires combining different types of experimental data.

  • Impact of preservative impregnation on wettability, surface free energy, and adhesive bonding of Scots pine CLT

    by Hasan Öztürk, Aydın Demir, Abdullah Uğur Birinci, Okan İlHan, Ali Çakmak, Cenk Demirkır, Engin Derya Gezer

  • Enhancing the durability of cross-laminated timber (CLT) with boron treatment in ground-contact conditions

    by Aydın Demir, Hasan Öztürk, Okan İlHan, Abdullah Uğur Birinci, Cenk Demirkir, Engin Derya Gezer


  • Durability and mechanical performance of copper azole-treated cross-laminated timber (CLT) in-ground-contact exposure for 6 months

    by Hasan Öztürk, Aydın Demir, Abdullah Uğur Birinci, Okan İlHan, Cenk Demirkir, Engin Derya Gezer


  • Open Access

    Economic Value Estimation for Protected Forest Areas with Hedonic Pricing: Case of Uzungöl Natural Park

    by Mahmut M. Bayramoğlu, Emre Küçükbekir, Zeki Candan, Cenk Demirkir

    Due to the increase in recreational demands, the significance of protected areas and forests with recreational potential in forests increased with the demands of nature tourism, which in turn provided new income sources to the forestry industry. In the current study, the economic values of the Uzungöl Nature Park’s lake view, an international tourist destination, were estimated using the hedonic pricing method. In the study, 188 questionnaires were conducted with 89 businesses, and the hedonic price function (HPF) was determined based on the study data collected from the businesses in Uzungöl Nature Park. It was estimated that the mean lake view in-room accommodation price for the hotels in Uzungöl Nature Park was USD 207.38 and the lake causes an increase of $2.8 per square meter and $144.67 in total on the room price of the hotels. The study findings demonstrated that the lake view was a desirable quality for hotel rooms, which is reflected in the prices in Uzungöl. The significant contribution of the lake view to room prices would support the planning and management of protected areas that are usually rich in natural resources. Determining the economic value of the lake view will enable business owners operating in the region or those planning to establish new businesses to make more informed pricing strategies. It will also strengthen hotel owners’ marketing campaigns and enable them to think more rationally about new investments (such as adding rooms or services). Business owners will be able to optimize their rooms based on lake views in order to offer more lake-view rooms to customers. Determining the economic value of the lake view will raise awareness about the protection of natural areas. By investing in eco-friendly and sustainable practices, hotel owners will contribute to the conservation of natural resources. The value estimates determined in the present study would also contribute to the employment of total forest value calculations and resource accounting systems.


  • Effect of lumber quality grade on the mechanical properties and product costs of cross-laminated timber panels

    by Mahmut M. Bayramoglu, Aydin Demir, Abdullah Ugur Birinci, Hasan Ozturk, Okan Ilhan, Zeki Candan, Cenk Demirkir

    This study aimed to investigate the effects of wood species and lumber quality grades on the mechanical properties and costs of cross-laminated timber (CLT) panels. Various combinations of lumber with different quality grades were utilized in the layers to identify the optimal configurations for producing CLT panels with high mechanical performance and low costs. In the study, spruce and Scots pine lumber of three different quality grades (Grades 1, 2, and 3), classified according to TS 1265 standards, were used. Some mechanical properties of the CLT panels produced from lumber of varying quality grades were determined following the TS EN 408 standard. Additionally, cost analyses of the CLT panels were conducted based on the calculation of raw material costs. The results show that while higher-grade lumber improves mechanical performance, lower-grade combinations still can meet structural needs at lower costs. Mixed-grade configurations offer a balance between strength and affordability. These findings can help CLT producers optimize material selection and reduce costs while maintaining structural integrity. Using lower-grade lumber can address shortages and reduce reliance on expensive timber. Policymakers can promote sustainable forestry and lower production costs, making mass timber construction more viable and environmentally sustainable.


  • Open Access

    Yapay Sinir Ağları (YSA) Kullanılarak CLT Perde Duvarların Yanal Yük Altındaki Rijitliklerinin Kereste Direnç Sınıflarına Göre Tahmin Edilmesi

    by Abdullah Uğur Birinci, Okan İlhan, Aydın Demir, Cenk Demirkır

    Bu çalışmada, öncelikle yapay sinir ağları (YSA) kullanarak ağaç türü ve kereste direnç sınıfları gibi üretim parametrelerinin CLT perde duvarların yanal yük altındaki rijitlik performansı üzerine etkilerinin belirlenmesi amaçlanmıştır. Daha sonra, analizler sonuncunda elde edilen YSA tahmin modellerini kullanarak, CLT perde duvarlar için en yüksek rijitlik değerini verecek orta ve dış tabakalarda kullanılan kereste direnç sınıflarına ait optimum tabaka kombinasyonlarının ortaya konulması amaçlanmıştır. Bu çalışmada, ladin ve kızılağaç kerestelerin kullanıldığı CLT paneller ile bu iki ağaç türünün kombinasyonlarından oluşturulan hibrit paneller üretilmiştir. Kerestelerin direnç sınıfları TS EN 338 standardına göre hasarsız olarak belirlenmiş ve ladin için C16, C22, C30, kızılağaç için ise D18, D30, D40 grubu keresteleri, çalışma kapsamında CLT üretiminde kullanılmak üzere seçilmiştir. Ağaç türü ve direnç sınıfı kombinasyonlarından oluşan 30 farklı test grubu için CLT paneller üretilmiştir. CLT panellerden oluşturulan perde duvarların analizleri ASTM E 72 standardına göre gerçekleştirilmiş ve elde edilen maksimum yük ile bu yükteki yer değiştirme miktarlarından rijitlikler hesaplanmıştır. YSA modellemeleri sonucunda, deneysel verilerden yola çıkarak tahmin değerleri elde edilmiş ve bu verilerle optimum tabaka kombinasyonları belirlenmiştir. Buna göre, CLT perde duvarlar için elde edilen optimum kereste direnç sınıfları ve tabaka kombinasyonları, ladinde C30-C18-C30, kızılağaçta D30-D35-D30, hibritlerde C30-D24-C30 ve D30-C30-D30 olarak tespit edilmiştir.


  • Open Access

    Perde duvarların yanal yük dayanımı üzerine kaplama elemanı ve yalıtım malzemesinin etkisinin araştırılması

    by Duygu Yücesoy, Okan İlhan, Abdullah Uğur Birinci, Cenk Demirkır

    Hafif karkas ahşap yapı sistemlerinde perde duvarlar; masif malzemenin genellikle kullanıldığı iskelet sistemi, kaplayıcı ya da örtücü eleman ve bağlantı elemanlarından oluşmaktadır. Kaplama eleman olarak, deprem ve rüzgâr gibi yapının yer değiştirerek uğradığı yatay deformasyona direnç göstererek çökmesini engellediği için kontrplaklar kullanılmaktadır. Perde duvarın yapısal özelliklerini ve kontrplakların teknolojik özelliklerini etkileyen birçok faktör bulunmaktadır. Ağaç türü, levha kalınlıkları, lif yönü, kusurlar, bağlantı elemanlarının türü, konumu ve aralarındaki mesafeler gibi faktörler, perde duvarın dayanıklılığı, mukavemeti ve yatay deformasyon miktarı üzerinde etkilidir. Bu faktörlerin bir araya gelmesi, perde duvarın genel performansını ve yatay deformasyon miktarını belirlemektedir. Bu çalışmada, yanal yük altındaki perde duvarlardaki yatay deformasyon miktarlarının belirlenmesi amaçlanmıştır. Çalışma, karaçam ve ladin ağaç türlerinden yapılan kontrplak kaplı perde duvarlarda yapısal ve teknolojik faktörlerin etkisini incelemektedir. Araştırmada, ağaç türü (karaçam ve ladin), kontrplak levha kalınlıkları, lif yönelimi (liflere dik ve paralel), kusurlar, bağlantı elemanı ölçüsü (6d ve 8d) gibi bir dizi değişken değerlendirilmektedir. Perde duvarlarda kullanılan yalıtım malzemeleri (Ekstrüde Polistiren (XPS), Ekspande Polistiren (EPS) gibi) de dikkate alınmış ve yanal yük altındaki yatay deformasyon miktarları belirlenmiştir. Araştırma sonuçları, karaçam kontrplaklarla kaplanan perde duvarların genel olarak ladinlere göre daha fazla yatay deformasyona uğradığını ve liflere paralel olarak üretilen perde duvarların genellikle daha yüksek yatay deformasyon değerlerine sahip olduğunu göstermiştir.