Jiangdong Li
Research Subjects
Jiangdong Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ke Wu
Zhejiang Key Laboratory of Offshore Civil Engineering and Materials, Zhejiang University, Hangzhou 310058, China
5 shared publications - Tianhang Zhang
Key Laboratory of Offshore Geotechnics and Material of Zhejiang Province, Zhejiang University, Hangzhou, China
4 shared publications Kai Zhu
2 shared publications- Kai Zhu
College of Energy Environment and Safety Engineering, China Jiliang University, Hangzhou, China
2 shared publications Lilin Wang
2 shared publications- Xinyan Huang
Department of Building Environment and Energy Engineering The Hong Kong Polytechnic University Kowloon Hong Kong
2 shared publications
Latest Publications
- 22 September 2026
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 179
Modelling delayed smoke ventilation induced by jet fans for performance-based design of tunnel fire safety
- 22 September 2026
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 179
Modelling delayed smoke ventilation induced by jet fans for performance-based design of tunnel fire safety
- Open Access
- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
Modelling Delayed Smoke Ventilation Induced by Jet Fans for Performance-based Design of Tunnel Fire Safety
Accurate specification of fire scenarios is fundamental to performance-based design (PBD) of tunnel fires. Previous studies mainly focus on fire source characteristics, whereas the dynamic development of longitudinal ventilation velocity and its inertial effect remains insufficiently considered. Through full-scale tunnel ventilation experiments and theoretical analysis, this study investigates the mechanism and characteristics of ventilation inertia and develops a design wind growth curve model for PBD application. The proposed model can predict the longitudinal velocity evolution under arbitrary multi-stage ventilation strategies based on tunnel environmental parameters, demonstrating good agreement with experimental data (errors < 4.20 %, R2 > 0.96, NRMSE < 11.92 %). Subsequently, a series of numerical simulations is then conducted to quantify the combined effects of smoke control strategy, fire growth rate, and ventilation inertia on tunnel fire performance. Results show that inertia-induced delayed wind speed response significantly degrades downstream safety in maintaining stratification scenarios, with the adverse effect intensifying as fire growth rate increases. For typical ultra-fast fires, the available safe egress time at 50 m and 100 m downstream of the fire decreases by 21.6% and 27.2%, respectively. These findings demonstrate that neglecting ventilation inertia may lead to non-conservative safety assessments and provide practical guidance for improving scenario definition and safety evaluation in future tunnel design.
- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessModelling Delayed Smoke Ventilation Induced by Jet Fans for Performance-based Design of Tunnel Fire Safety
Accurate specification of fire scenarios is fundamental to performance-based design (PBD) of tunnel fires. Previous studies mainly focus on fire source characteristics, whereas the dynamic development of longitudinal ventilation velocity and its inertial effect remains insufficiently considered. Through full-scale tunnel ventilation experiments and theoretical analysis, this study investigates the mechanism and characteristics of ventilation inertia and develops a design wind growth curve model for PBD application. The proposed model can predict the longitudinal velocity evolution under arbitrary multi-stage ventilation strategies based on tunnel environmental parameters, demonstrating good agreement with experimental data (errors < 4.20 %, R2 > 0.96, NRMSE < 11.92 %). Subsequently, a series of numerical simulations is then conducted to quantify the combined effects of smoke control strategy, fire growth rate, and ventilation inertia on tunnel fire performance. Results show that inertia-induced delayed wind speed response significantly degrades downstream safety in maintaining stratification scenarios, with the adverse effect intensifying as fire growth rate increases. For typical ultra-fast fires, the available safe egress time at 50 m and 100 m downstream of the fire decreases by 21.6% and 27.2%, respectively. These findings demonstrate that neglecting ventilation inertia may lead to non-conservative safety assessments and provide practical guidance for improving scenario definition and safety evaluation in future tunnel design.