Aaron Barrett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aaron Barrett has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Aaron L. Fogelson
Departments of Mathematics and Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
6 shared publications- Boyce E. Griffith
Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
4 shared publications Andrew Woodward
Advanced Medical Imaging Lab University of North Carolina Medical Center Chapel Hill North Carolina USA
2 shared publicationsBoyce E. Griffith
Departments of Mathematics Applied Physical Sciences, and Biomedical Engineering University of North Carolina Chapel Hill NC USA
2 shared publicationsJohn P. Vavalle
University of North Carolina School of Medicine Chapel Hill North Carolina USA
2 shared publicationsMargaret Anne Smith
Department of Mathematics University of North Carolina Chapel Hill North Carolina USA
2 shared publications
Latest Publications
- 23 August 2025
- Published by Elsevier in Computers & Fluids
- Vol. 301
Adaptive mesh refinement for two-phase viscoelastic fluid mixture models
- 23 August 2025
- Published by Elsevier in Computers & Fluids
- Vol. 301
Adaptive mesh refinement for two-phase viscoelastic fluid mixture models
- Open Access
- 11 November 2024
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 999, A2
Flagellum pumping efficiency in shear-thinning viscoelastic fluids
Microorganism motility often takes place within complex, viscoelastic fluid environments, e.g. sperm in cervicovaginal mucus and bacteria in biofilms. In such complex fluids, strains and stresses generated by the microorganism are stored and relax across a spectrum of length and time scales and the complex fluid can be driven out of its linear response regime. Phenomena not possible in viscous media thereby arise from feedback between the swimmer and the complex fluid, making swimming efficiency co-dependent on the propulsion mechanism and fluid properties. Here, we parameterize a flagellar motor and filament properties together with elastic relaxation and nonlinear shear-thinning properties of the fluid in a computational immersed boundary model. We then explore swimming efficiency, defined as a particular flow rate divided by the torque required to spin the motor, over this parameter space. Our findings indicate that motor efficiency (measured by the volumetric flow rate) can be boosted or degraded by relatively moderate or strong shear thinning of the viscoelastic environment.
- 11 November 2024
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 999, A2
Open AccessFlagellum pumping efficiency in shear-thinning viscoelastic fluids
Microorganism motility often takes place within complex, viscoelastic fluid environments, e.g. sperm in cervicovaginal mucus and bacteria in biofilms. In such complex fluids, strains and stresses generated by the microorganism are stored and relax across a spectrum of length and time scales and the complex fluid can be driven out of its linear response regime. Phenomena not possible in viscous media thereby arise from feedback between the swimmer and the complex fluid, making swimming efficiency co-dependent on the propulsion mechanism and fluid properties. Here, we parameterize a flagellar motor and filament properties together with elastic relaxation and nonlinear shear-thinning properties of the fluid in a computational immersed boundary model. We then explore swimming efficiency, defined as a particular flow rate divided by the torque required to spin the motor, over this parameter space. Our findings indicate that motor efficiency (measured by the volumetric flow rate) can be boosted or degraded by relatively moderate or strong shear thinning of the viscoelastic environment.
- 4 April 2023
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 39 (5) , e3700
A model offluid–structureand biochemical interactions for applications to subclinical leaflet thrombosis
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid–structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis because they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid–structure interaction.
- 4 April 2023
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 39 (5) , e3700
A model offluid–structureand biochemical interactions for applications to subclinical leaflet thrombosis
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid–structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis because they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid–structure interaction.
- Open Access
A Model of Fluid-Structure and Biochemical Interactions for Applications to Subclinical Leaflet Thrombosis
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid-structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis in which they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid-structure interaction.
Open AccessA Model of Fluid-Structure and Biochemical Interactions for Applications to Subclinical Leaflet Thrombosis
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid-structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis in which they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid-structure interaction.
- 9 August 2022
- Published by Elsevier in Journal of Computational Physics
- Vol. 469
Immersed boundary simulations of cell-cell interactions in whole blood
- 9 August 2022
- Published by Elsevier in Journal of Computational Physics
- Vol. 469
Immersed boundary simulations of cell-cell interactions in whole blood
- 28 October 2021
- Published by Elsevier in Journal of Computational Physics
- Vol. 449
A hybrid semi-Lagrangian cut cell method for advection-diffusion problems with Robin boundary conditions in moving domains
- 28 October 2021
- Published by Elsevier in Journal of Computational Physics
- Vol. 449
A hybrid semi-Lagrangian cut cell method for advection-diffusion problems with Robin boundary conditions in moving domains
- Open Access
A Hybrid Semi-Lagrangian Cut Cell Method for Advection-Diffusion Problems with Robin Boundary Conditions in Moving Domains
We present a new discretization for advection-diffusion problems with Robin boundary conditions on complex time-dependent domains. The method is based on second order cut cell finite volume methods introduced by Bochkov et al. to discretize the Laplace operator and Robin boundary condition. To overcome the small cell problem, we use a splitting scheme that uses a semi-Lagrangian method to treat advection. We demonstrate second order accuracy in the $L^1$, $L^2$, and $L^\infty$ norms for both analytic test problems and numerical convergence studies. We also demonstrate the ability of the scheme to handle conversion of one concentration field to another across a moving boundary.Open AccessA Hybrid Semi-Lagrangian Cut Cell Method for Advection-Diffusion Problems with Robin Boundary Conditions in Moving Domains
We present a new discretization for advection-diffusion problems with Robin boundary conditions on complex time-dependent domains. The method is based on second order cut cell finite volume methods introduced by Bochkov et al. to discretize the Laplace operator and Robin boundary condition. To overcome the small cell problem, we use a splitting scheme that uses a semi-Lagrangian method to treat advection. We demonstrate second order accuracy in the $L^1$, $L^2$, and $L^\infty$ norms for both analytic test problems and numerical convergence studies. We also demonstrate the ability of the scheme to handle conversion of one concentration field to another across a moving boundary.