SVSangamanatha Ankmnal Veeranna

Sangamanatha Ankmnal Veeranna

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sangamanatha Ankmnal Veeranna has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Charles G. Marx

    School of Speech and Hearing Science, The University of Southern Mississippi, Hattiesburg

    2 shared publications
  • Charles Gordon Marx

    School of Speech and Hearing Sciences, The College of Nursing Health and Professions, The University of Southern Mississippi, Hattiesburg, United States

    2 shared publications
  • Hasitha Wimalarathna

    Department of Electrical & Computer Engineering, Western University, London, Ontario, Canada; National Centre for Audiology, Western University, London, Ontario, Canada

    2 shared publications
  • Jennifer Candace-Ann Chapman

    School of Speech and Hearing Science, The University of Southern Mississippi, Hattiesburg

    2 shared publications
  • Jennifer Chapman

    School of Speech and Hearing Sciences, College of Nursing and Health Professions, The University of Southern Mississippi, Hattiesburg

    2 shared publications
  • Patricia LeeAnn Youngblood

    School of Speech and Hearing Sciences, The University of Southern Mississippi, Hattiesburg

    2 shared publications

Latest Publications

  • Effect of Stimulus Rate on Click and CE-Chirp–Evoked Auditory Brainstem Responses in Infants and Adults

    by Sangamanatha Ankmnal Veeranna, Charles G. Marx, Caroline Armstrong, Hasitha Wimalarathna

    Purpose: The purpose of the present study was to examine the effect of click and CE-Chirp stimulus rate on auditory brainstem responses (ABRs) in infants and adults. Traditional clinical measures were used to examine the responses. Also, the ABR time–frequency characteristics were explored using automated feature engineering. Method: ABRs were recorded from 37 infant ears and in 39 young adults. ABRs were recorded for both click and CE-Chirp stimuli at 70 dB nHL for different rates (23.3/s, 53.3/s, and 83.3/s). Results: Across all rates, both click and CE-Chirp–evoked ABRs showed similar Peak I latencies in infants and adults; however, Peak III and V latencies varied. Click-evoked ABRs were earlier in latencies when compared to CE-Chirp–evoked ABRs in both groups, whereas CE-Chirp–evoked ABRs were larger in amplitude compared to click-evoked ABRs. Stimulus-type–dependent changes in the absolute ABR latencies were observed as the stimulus rate was increased. The ABR time–frequency characteristics varied with stimulus rate and were dependent on the feature extraction method applied. Conclusions: The effect of click stimulus rate on ABRs in infants and adults demonstrated in this study agrees with published literature, but our findings with the CE-Chirp do not. Audiologists and researchers should be aware of differences in ABRs due to the effect of stimulus type and rate.

  • The Effect of Transducer High-Frequency Output on Clinically Used Speech Recognition in Noise Tests

    by Sangamanatha Ankmnal Veeranna, Jennifer Chapman

    Purpose: The purpose of the present study was to determine whether standard and high-frequency transducers influence test scores on clinically used speech-in-noise (SIN) assessments, such as the Word-In-Noise (WIN) and QuickSIN tests. Method: Sixteen individuals whose hearing thresholds were within normal limits (≤ 25 dB HL at 0.5, 1, 2, and 4 kHz), and nine individuals with sensorineural hearing loss participated in this research. Hearing thresholds were obtained at extended high frequencies in adults with normal hearing. The WIN and QuickSIN tests were administered to only one ear. These tests were conducted using the RadioEar IP30 and RadioEar DD450 transducers. Results: There were no significant differences in the WIN and QuickSIN test scores between the IP30 and DD450 transducers in both groups. Analysis of WIN and QuickSIN test scores of individuals whose thresholds were within normal limits while controlling for age and extended high-frequency hearing thresholds showed no significant effect of the transducer, suggesting that these factors did not influence the test scores. Conclusion: The findings of this study suggest that both IP30 inserts and DD450 headphones are suitable for use in WIN and QuickSIN testing.

  • Comparison of Auditory Brainstem Responses Recorded from Three Different Clinical Systems

    by Jennifer Chapman, Tyler Weaver, Sangamanatha Ankmnal Veeranna, Charles Marx

    Background: The auditory brainstem response (ABR) test is used to estimate hearing thresholds and for neurodiagnostic purposes. ABRs can be recorded for traditional stimuli such as broadband clicks and frequency-specific tone bursts (0.5, 1, 2, and 4 kHz). Recently, chirp stimuli (broadband and narrowband chirps [0.5, 1, 2, and 4 kHz]) have been recommended to be used to record ABRs. Purpose: There is a lack of comparative studies of ABR latency, amplitude, and thresholds obtained from these systems for both traditional and chirp stimuli. Research Design: Repeated measure design. Study Sample: Fifteen adults whose hearing thresholds were ≤25 dB HL participated in this study. Data Collection and Analysis: The Interacoustics Eclipse-25 (EP-25), the Intelligent Hearing System (IHS), and the Vivosonic Integrity V500 systems were used. Peak-to-peak voltage was examined for traditional and chirp stimuli across all three systems. Behavioral and ABR thresholds were obtained for all stimuli. Also, peak V latencies and peak-to-peak amplitudes for all stimuli recorded at 80 dBnHL were examined. Results: Peak-to-peak voltage differed between systems, especially for chirp stimuli. The EP-25 and the IHS systems showed significantly lower behavioral thresholds for some chirp stimuli compared with traditional, comparable stimuli, whereas the Integrity V500 system showed significantly lower behavioral thresholds for broadband click and 4-kHz tone burst stimuli compared with comparable chirp stimuli. Significant differences in behavioral thresholds between systems were observed. The EP-25 (broadband chirp, 1-, 2-, and 4-kHz narrowband chirp) and the IHS (2-kHz narrowband chirp) showed significantly lower ABR thresholds for comparable stimuli, whereas the Integrity V500 system showed lower ABR thresholds for broadband click and 0.5-kHz tone burst stimuli compared with comparable chirp stimuli. ABR thresholds for 2-kHz tone burst and 0.5- and 2-kHz narrowband chirp stimuli were significantly different between systems. The peak V latencies of the IHS system were significantly longer for most of the stimuli compared with other systems. The Integrity V500 system showed significantly lower peak-to-peak amplitudes of peak V for most of the stimuli when compared with other systems. Conclusions: The ABR latencies, amplitudes, and thresholds may differ between ABR recording systems, and clinicians should be aware of these differences to avoid misdiagnosis. Clinical Relevance Statement: The differences in ABR latencies, amplitudes, and thresholds between systems may lead to inconsistencies in diagnostic accuracy. Audiologists should use system-specific normative data.


  • Estimating Hearing Thresholds Using Cortical Auditory Evoked Potentials

    by Sally Grantham, Patricia LeeAnn Youngblood, Sangamanatha Ankmnal-Veeranna, Charles G. Marx

    Purpose: This study aimed to assess the effectiveness of the cortical auditory evoked potential (CAEP) test for estimating hearing thresholds with a clinical auditory evoked potential (AEP) system. Method: Thirty individuals whose hearing thresholds were not ≥ 25 dB HL (aged 20–53 years) and 20 individuals who are hard of hearing (aged 22–80 years) participated in this study. Behavioral hearing thresholds were obtained from participants in both groups. CAEPs for 500-, 1000-, 2000-, and 4000-Hz tone bursts were recorded using a two-channel clinical AEP system. Results: The mean CAEP and behavioral threshold difference for participants whose hearing thresholds are within 25 dB HL was ≤ 15 dB, and for individuals who are hard of hearing, it was ≤ 10 dB. There was no significant effect of test frequency in CAEP and behavioral threshold differences. Similar findings have been reported in the literature. Conclusions: The CAEP thresholds closely match behavioral thresholds in adults with and without hearing loss. The findings of our study suggest that using a clinical AEP system may allow for the estimation of hearing thresholds using the CAEP test in adults.

  • Auditory Brainstem Responses at 8 kHz: Data From Normal-Hearing Infants and Adults

    by Jennifer Candace-Ann Chapman, Sangamanatha Ankmnal-Veeranna, Charles Gordon Marx

    Purpose: The goal of this study is to examine auditory brainstem responses (ABRs) recorded for click and 8-kHz tone bursts (TBs) from normal-hearing infants and adults using a clinical auditory-evoked potential system. Method: Infants ( n = 34) and adults ( n = 10) with normal hearing participated in this study. ABRs for click stimuli and 8-kHz TBs were recorded at 70 dB nHL. ABR thresholds for 8-kHz TBs were obtained from both groups. In addition, behavioral thresholds for the 8-kHz TB stimulus were obtained from adults. Given that adults can participate in traditional behavioral testing, their data were included to demonstrate a correlation between behavioral thresholds for 8-kHz TB and electrophysiological thresholds for the same stimulus. Results: Peak I latency of the ABR for both click and 8-kHz TBs at 70 dB nHL were similar between adults and infants. Latencies of Peaks III and V of the ABR for both click and 8-kHz TBs were significantly prolonged in infants when compared to adults. Infants' ABR thresholds for 8 kHz were significantly elevated when compared to adults. Conclusion: The ABR for 8-kHz TB stimuli is not adultlike in newborn infants and this could be due to immature synaptic and axonal processing.


  • Leveraging cluster analysis to compare click and chirp-evoked auditory brainstem responses

    by Hasitha Wimalarathna, Patricia LeeAnn Youngblood, Caroline Parker, Charles G. Marx, Sangamanatha Ankmnal-Veeranna


  • Comparison of Adaptive and Nonadaptive Gap Detection in Noise Test in Typically Developing Children and Adults

    by Sangamanatha Ankmnal Veeranna, Lyerly Christensen, Jennifer Candace-Ann Chapman

    Purpose The purpose of this study is to examine whether the gap detection thresholds (GDT) obtained are similar between an adaptive and nonadaptive procedure in children and adults. Study Design Standard group comparison. Study Sample Eighteen typically developing children and 20 young adults with hearing thresholds of 25 dB HL or lower participated in this study. Methods Forced choice (FC) adaptive GDTs were obtained using psychoacoustic software, and nonadaptive GDTs were obtained using a clinically available gap in noise (GIN) test. Results Both children and adults showed significantly lower GDTs for the FC adaptive procedure when compared with thresholds obtained using the nonadaptive GIN test. GDTs were less variable for FC adaptive procedure when compared with the nonadaptive procedure. Conclusion Lower and less variable GDTs can be obtained from children and adults using an FC adaptive procedure.

  • Open Access

    Verification of a Mobile Psychoacoustic Test System

    by Jordana C. Soares, Sangamanatha A. Veeranna, Vijay Parsa, Chris Allan, Winnie Ly, Minh Duong, Paula Folkeard, Sheila Moodie, Prudence Allen

    Many hearing difficulties can be explained as a loss of audibility, a problem easily detected and treated using standard audiological procedures. Yet, hearing can be much poorer (or more impaired) than audibility predicts because of deficits in the suprathreshold mechanisms that encode the rapidly changing, spectral, temporal, and binaural aspects of the sound. The ability to evaluate these mechanisms requires well-defined stimuli and strict adherence to rigorous psychometric principles. This project reports on the comparison between a laboratory-based and a mobile system’s results for psychoacoustic assessment in adult listeners with normal hearing. A description of both systems employed is provided. Psychoacoustic tests include frequency discrimination, amplitude modulation detection, binaural encoding, and temporal gap detection. Results reported by the mobile system were not significantly different from those collected with the laboratory-based system for most of the tests and were consistent with those reported in the literature. The mobile system has the potential to be a feasible option for the assessment of suprathreshold auditory encoding abilities.