Yanting Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanting Cheng has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Haotian Tan
Department of Electric Power Engineering, South China University of Technology, Guangzhou, Guangdong, China
3 shared publications - Licheng Li
School of Electric Power, South China University of Technology, Guangzhou, China
3 shared publications - Qishun Li
Hangzhou Xiaoshan Power Supply Company, State Grid Zhejiang Electric Power Co., Ltd, Hang Zhou, People’s Republic of China
3 shared publications Wanxing Tian
Department of Electric Power Engineering, South China University of Technology, Guangzhou, China
3 shared publications- Yanpeng Hao
School of Electric Power, South China University of Technology, Guangzhou 510640, China
3 shared publications Peng Zhao
Department of Electric Power Engineering, South China University of Technology, Guangzhou, China
2 shared publications
Latest Publications
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1127-1136
Measurement Method for Temperature Sensitivity Coefficient of Embedded Optical Fiber in High-Voltage XLPE Cable—Shorter Than Spatial Resolution of BOTDR
Temperature sensitivity coefficient of optical fiber is a critical parameter for distributed temperature measurement based on Brillouin scattering. However, the optical fiber required by traditional coefficient measurement method, is so long that it is not suitable for embedded optical fiber in high-voltage (HV) cross-linked polyethylene (XLPE) power cables. In this paper, a measuring system for temperature sensitivity coefficient of distributed Brillouin scattering optical fiber is established. By modulating the temperature of a short section of optical fiber to be remarkably differ from that of remaining optical fiber within the spatial resolution of sensing system, the coefficient can be obtained through measuring the Brillouin frequency shift (BFS) of the modulated peak in Brillouin gain spectrum (BGS). The results show that using Brillouin optical time domain reflectometer (BOTDR) with a spatial resolution of 10 m, the coefficient obtained by optical fiber longer than 0.5 m is the same as that obtained by 10 m optical fiber. As the phenomenon that the temperature sensitivity coefficient of polyvinyl chloride (PVC) jacketed optical fiber in the water blocking tape and power cable are both 1.4 MHz/°C, the embedded optical fiber in tape can be used to replace that in HV XLPE cable to measure the coefficient.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1127-1136
Measurement Method for Temperature Sensitivity Coefficient of Embedded Optical Fiber in High-Voltage XLPE Cable—Shorter Than Spatial Resolution of BOTDR
Temperature sensitivity coefficient of optical fiber is a critical parameter for distributed temperature measurement based on Brillouin scattering. However, the optical fiber required by traditional coefficient measurement method, is so long that it is not suitable for embedded optical fiber in high-voltage (HV) cross-linked polyethylene (XLPE) power cables. In this paper, a measuring system for temperature sensitivity coefficient of distributed Brillouin scattering optical fiber is established. By modulating the temperature of a short section of optical fiber to be remarkably differ from that of remaining optical fiber within the spatial resolution of sensing system, the coefficient can be obtained through measuring the Brillouin frequency shift (BFS) of the modulated peak in Brillouin gain spectrum (BGS). The results show that using Brillouin optical time domain reflectometer (BOTDR) with a spatial resolution of 10 m, the coefficient obtained by optical fiber longer than 0.5 m is the same as that obtained by 10 m optical fiber. As the phenomenon that the temperature sensitivity coefficient of polyvinyl chloride (PVC) jacketed optical fiber in the water blocking tape and power cable are both 1.4 MHz/°C, the embedded optical fiber in tape can be used to replace that in HV XLPE cable to measure the coefficient.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1778-1787
Distributed Optical Fiber Detection Based on BOTDR for Buffer Layer Defects of High-Voltage XLPE Cable With Corrugated Aluminum Sheath
In recent years, buffer layer defects have occur in high-voltage (HV) crosslinked polyethylene (XLPE) cable frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, embedded with single-mode optical fiber. Meanwhile, a distributed optical fiber detection system for buffer layer defects based on Brillouin optical time domain reflectometry (BOTDR) was built. The partial discharge (PD) test and BOTDR detection test for defective cable were conducted to study the relationship between Brillouin frequency shift (BFS) variation of built-in fiber and temperature rise resulting from dielectric loss, white powder, and damaged insulation. During applying voltage of 96 kV for 7 hours, the BFS variations within white powder and damaged insulation defects are significantly larger than that within non-defect which is only determined by dielectric loss. The BFS variations are closely related to the number and depth of damaged insulation holes, as well as circumferential angle of holes against optical fiber. But the BFS variations within moisture water blocking tape, poor electrical connection, and damaged insulation screen cannot be distinguished from that within non-defect.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 1778-1787
Distributed Optical Fiber Detection Based on BOTDR for Buffer Layer Defects of High-Voltage XLPE Cable With Corrugated Aluminum Sheath
In recent years, buffer layer defects have occur in high-voltage (HV) crosslinked polyethylene (XLPE) cable frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, embedded with single-mode optical fiber. Meanwhile, a distributed optical fiber detection system for buffer layer defects based on Brillouin optical time domain reflectometry (BOTDR) was built. The partial discharge (PD) test and BOTDR detection test for defective cable were conducted to study the relationship between Brillouin frequency shift (BFS) variation of built-in fiber and temperature rise resulting from dielectric loss, white powder, and damaged insulation. During applying voltage of 96 kV for 7 hours, the BFS variations within white powder and damaged insulation defects are significantly larger than that within non-defect which is only determined by dielectric loss. The BFS variations are closely related to the number and depth of damaged insulation holes, as well as circumferential angle of holes against optical fiber. But the BFS variations within moisture water blocking tape, poor electrical connection, and damaged insulation screen cannot be distinguished from that within non-defect.
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1443-1452
Breakpoint and Moisture Detection Method Based on Distributed Brillouin Optical Fiber Built in Buffer Layer of High-Voltage XLPE Cable
In recent years, the water blocking tape in high-voltage (HV) crosslinked polyethylene (XLPE) cable is suffered from penetrating moisture frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, with a single-mode fiber of 30 m built in it. Meanwhile, a distributed detection system for built-in optical fiber of 110 kV cable was established and the criterion for BOTDR breakpoint detection method was proposed. The comparison test of breakpoint detection methods for built-in optical fiber was carried out using Brillouin optical time domain reflectometry (BOTDR) and optical time domain reflectometry (OTDR). Besides, detection tests of moisture water blocking tape including its drying process were launched using BOTDR. The relationship of Brillouin frequency shift (BFS) with moisture length, position, and drying process of the tape was studied. The results have demonstrated that BOTDR plays a better role in detecting breakpoint with poor-quality end face than OTDR. By using BOTDR to detect moisture tape in cable, the BFS decreases sharply when moisture length over some thresholds and linearly falls with increasing moisture length. As time passes, the BFS gradually increases, which can characterize drying process.
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1443-1452
Breakpoint and Moisture Detection Method Based on Distributed Brillouin Optical Fiber Built in Buffer Layer of High-Voltage XLPE Cable
In recent years, the water blocking tape in high-voltage (HV) crosslinked polyethylene (XLPE) cable is suffered from penetrating moisture frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, with a single-mode fiber of 30 m built in it. Meanwhile, a distributed detection system for built-in optical fiber of 110 kV cable was established and the criterion for BOTDR breakpoint detection method was proposed. The comparison test of breakpoint detection methods for built-in optical fiber was carried out using Brillouin optical time domain reflectometry (BOTDR) and optical time domain reflectometry (OTDR). Besides, detection tests of moisture water blocking tape including its drying process were launched using BOTDR. The relationship of Brillouin frequency shift (BFS) with moisture length, position, and drying process of the tape was studied. The results have demonstrated that BOTDR plays a better role in detecting breakpoint with poor-quality end face than OTDR. By using BOTDR to detect moisture tape in cable, the BFS decreases sharply when moisture length over some thresholds and linearly falls with increasing moisture length. As time passes, the BFS gradually increases, which can characterize drying process.