Ping-Yang Liu
Research Interests
Ping-Yang Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Geng-Shi Jeng
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
2 shared publications - Bo-Cheng Lai
National yang Ming Chiao Tung University
1 shared publication - Cheng-Shun Chuang
Department of Computer Science, Virginia Tech, Blacksburg, VA, USA
1 shared publication Chia-Lun Yeh
Hon Hai Precision Industry, New Taipei City, Taiwan
1 shared publicationChin-Shu Yao
Medical Imaging Business Unit, Research and Development Division 1, Qisda Corporation, Hsinchu, Taiwan
1 shared publicationChun-Yi Chen
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
1 shared publication
Latest Publications
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (23) , 43256-43266
Design of a Low-Cost, High-Resolution Underwater Acoustic Imager With Integrated Deep Learning Enhancement
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (23) , 43256-43266
Design of a Low-Cost, High-Resolution Underwater Acoustic Imager With Integrated Deep Learning Enhancement
- 29 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (7) , 2496-2506
Laser-Generated Leaky Acoustic Wave Imaging for Interventional Guidewire Guidance
Ultrasound (US) is widely used to visualize both tissue and the positions of surgical instruments in real time during surgery. Previously we proposed a new method to exploit US imaging and laser-generated leaky acoustic waves for needle visualization. Although successful, that method only detects the position of a needle tip, with the location of the entire needle deduced from knowing that the needle is straight. The purpose of the current study was to develop a beamforming-based method for the direct visualization of objects. The approach can be applied to objects with arbitrary shapes, such as the guidewires that are commonly used in interventional guidance. With this method, illumination by a short laser pulse generates photoacoustic waves at the top of the guidewire that propagate down its metal surface. These waves then leak into the surrounding tissue, which can be detected by an US array transducer. The time of flight consists of two parts: (1) the propagation time of the guided waves on the guidewire and (2) the propagation time of the US that leaks into the tissue. In principle, an image of the guidewire can be formed based on array beamforming by taking the propagation time on the metal into consideration. Furthermore, we introduced directional filtering and a matched filter to compress the dispersion signal associated with long propagation times. The results showed that guidewires could be detected at depths of at least 70 mm. The maximum detectable angle was 56.3°. Leaky acoustic wave imaging with a 1268-mm long guidewire was also demonstrated. The proposed method has considerable potential in new clinical applications.
- 29 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (7) , 2496-2506
Laser-Generated Leaky Acoustic Wave Imaging for Interventional Guidewire Guidance
Ultrasound (US) is widely used to visualize both tissue and the positions of surgical instruments in real time during surgery. Previously we proposed a new method to exploit US imaging and laser-generated leaky acoustic waves for needle visualization. Although successful, that method only detects the position of a needle tip, with the location of the entire needle deduced from knowing that the needle is straight. The purpose of the current study was to develop a beamforming-based method for the direct visualization of objects. The approach can be applied to objects with arbitrary shapes, such as the guidewires that are commonly used in interventional guidance. With this method, illumination by a short laser pulse generates photoacoustic waves at the top of the guidewire that propagate down its metal surface. These waves then leak into the surrounding tissue, which can be detected by an US array transducer. The time of flight consists of two parts: (1) the propagation time of the guided waves on the guidewire and (2) the propagation time of the US that leaks into the tissue. In principle, an image of the guidewire can be formed based on array beamforming by taking the propagation time on the metal into consideration. Furthermore, we introduced directional filtering and a matched filter to compress the dispersion signal associated with long propagation times. The results showed that guidewires could be detected at depths of at least 70 mm. The maximum detectable angle was 56.3°. Leaky acoustic wave imaging with a 1268-mm long guidewire was also demonstrated. The proposed method has considerable potential in new clinical applications.