CȘCristina-Maria Șulea

Cristina-Maria Șulea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cristina-Maria Șulea has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dimethyltryptamine improves early graft hemodynamic performance in a heterotopic rat heart transplantation model

    by Máté Csonka, Givi Damenija, Roland Stengl, Tímea Bálint, Dávid Nagy, András Budai, Botond Erőss, Cristina M. Șulea, Ede Frecska, Béla Merkely, et al.

    Preserving donor organ viability during cold storage is critical for successful heart transplantation, as ischemia–reperfusion injury (IRI) adversely affects graft function. N, N-Dimethyltryptamine (DMT), an endogenous sigma-1 receptor ligand, has demonstrated cytoprotective effects under hypoxic and oxidative stress. This study evaluated the effects of DMT on graft recovery in a rat model of heterotopic heart transplantation. Hearts from male Lewis rats were preserved for 1 h at 4 °C in either Custodiol solution or Custodiol supplemented with DMT. Both donors and recipients in the treatment group also received DMT. After transplantation, graft function was assessed 60 min into reperfusion using preload-dependent pressure measurements, complemented by molecular and histological evaluations. DMT-treated grafts exhibited higher left ventricular systolic pressure, enhanced myocardial contractility and improved diastolic relaxation compared with controls. Gene expression analysis revealed significant modulation of Ddit3 , Hif1a and Vldlr , with trends in apoptotic and metabolic markers. A strong trend toward increased cleaved caspase-3 expression and significantly higher p62 immunohistochemical scores were observed, whereas cardiac troponin I and TNF-α levels remained unchanged. Overall, these findings indicate that DMT treatment improves early post-transplant graft contractile performance under the experimental conditions tested. The mechanisms underlying the observed functional improvement remain to be further elucidated.

  • Marfan syndrome cardiomyocytes show excess of titin isoform N2BA and extended sarcomeric M-band

    by Dalma Kellermayer, Cristina M. Șulea, Hedvig Tordai, Kálmán Benke, Miklós Pólos, Bence Ágg, Roland Stengl, Máté Csonka, Tamás Radovits, Béla Merkely, et al.

    Marfan syndrome (MFS) is an autosomal dominant disease caused by mutations in the gene (FBN1) of fibrillin-1, a major determinant of the extracellular matrix (ECM). Functional impairment in the cardiac left ventricle (LV) of these patients is usually a consequence of aortic valve disease. However, LV passive stiffness may also be affected by chronic changes in mechanical load and ECM dysfunction. Passive stiffness is determined by the giant sarcomeric protein titin that has two main cardiac splice isoforms: the shorter and stiffer N2B and the longer and more compliant N2BA. Their ratio is thought to reflect myocardial response to pathologies. Whether this ratio and titin’s sarcomeric layout is altered in MFS is currently unknown. Here, we studied LV samples from MFS patients carrying FBN1 mutation, collected during aortic root replacement surgery. We found that the N2BA:N2B titin ratio was elevated, indicating a shift toward the more compliant isoform. However, there were no alterations in the total titin content compared with healthy humans based on literature data. Additionally, while the gross sarcomeric structure was unaltered, the M-band was more extended in the MFS sarcomere. We propose that the elevated N2BA:N2B titin ratio reflects a general adaptation mechanism to the increased volume overload resulting from the valvular disease and the direct ECM disturbances so as to reduce myocardial passive stiffness and maintain diastolic function in MFS.


  • Open Access

    Nanoscale Structural Comparison of Fibrillin-1 Microfibrils Isolated from Marfan and Non-Marfan Syndrome Human Aorta

    by Cristina M. Șulea, Zsolt Mártonfalvi, Csilla Csányi, Dóra Haluszka, Miklós Pólos, Bence Ágg, Roland Stengl, Kálmán Benke, Zoltán Szabolcs, Miklós S. Z. Kellermayer

    Fibrillin-1 microfibrils are essential elements of the extracellular matrix serving as a scaffold for the deposition of elastin and endowing connective tissues with tensile strength and elasticity. Mutations in the fibrillin-1 gene (FBN1) are linked to Marfan syndrome (MFS), a systemic connective tissue disorder that, besides other heterogeneous symptoms, usually manifests in life-threatening aortic complications. The aortic involvement may be explained by a dysregulation of microfibrillar function and, conceivably, alterations in the microfibrils’ supramolecular structure. Here, we present a nanoscale structural characterization of fibrillin-1 microfibrils isolated from two human aortic samples with different FBN1 gene mutations by using atomic force microscopy, and their comparison with microfibrillar assemblies purified from four non-MFS human aortic samples. Fibrillin-1 microfibrils displayed a characteristic “beads-on-a-string” appearance. The microfibrillar assemblies were investigated for bead geometry (height, length, and width), interbead region height, and periodicity. MFS fibrillin-1 microfibrils had a slightly higher mean bead height, but the bead length and width, as well as the interbead height, were significantly smaller in the MFS group. The mean periodicity varied around 50–52 nm among samples. The data suggest an overall thinner and presumably more frail structure for the MFS fibrillin-1 microfibrils, which may play a role in the development of MFS-related aortic symptomatology.


  • Open Access

    What Patients Find on the Internet When Looking for Information About Percutaneous Coronary Intervention: Multilanguage Cross-sectional Assessment

    by Cristina M Șulea, Valentin Nădășan, Tatiana Ursachi, Paul-Cătălin Toboltoc, Theodora Benedek

    Background: The internet provides general users with wide access to medical information. However, regulating and controlling the quality and reliability of the considerable volume of available data is challenging, thus generating concerns about the consequences of inaccurate health care–related documentation. Several tools have been proposed to increase the transparency and overall trustworthiness of medical information present on the web. Objective: We aimed to analyze and compare the quality and reliability of information about percutaneous coronary intervention on English, German, Hungarian, Romanian, and Russian language websites. Methods: Following a rigorous protocol, 125 websites were selected, 25 for each language sub-sample. The websites were assessed concerning their general characteristics, compliance with a set of eEurope 2002 credibility criteria, and quality of the informational content (namely completeness and accuracy), based on a topic-specific benchmark. Completeness and accuracy were graded independently by 2 evaluators. Scores were reported on a scale from 0 to 10. The 5 language subsamples were compared regarding credibility, completeness, and accuracy. Correlations between credibility scores on the one hand, and completeness and accuracy scores, on the other hand, were tested within each language subsample. Results: The websites’ compliance with credibility criteria was average at best with scores between 3.0 and 6.0. In terms of completeness and accuracy, the website subsets qualified as poor or average, with scores ranging from 2.4 to 4.6 and 3.6 to 5.3, respectively. English language websites scored significantly higher in all 3 aspects, followed by German and Hungarian language websites. Only German language websites showed a significant correlation between credibility and information quality. Conclusions: The quality of websites in English, German, Hungarian, Romanian, and Russian languages about percutaneous coronary intervention was rather inadequate and may raise concerns regarding their impact on informed decision-making. Using credibility criteria as indicators of information quality may not be warranted, as credibility scores were only exceptionally correlated with content quality. The study brings valuable descriptive data on the quality of web-based information regarding percutaneous coronary intervention in multiple languages and raises awareness about the need for responsible use of health-related web resources.


  • Open Access

    Staged Hybrid Repair of a Complex Type B Aortic Dissection

    by Cristina-Maria Șulea, Csaba Csobay-Novák, Zoltán Oláh, Péter Banga, Zoltán Szeberin, Ádám Soltész, Zsófia Jokkel, Kálmán Benke, Máté Csonka, Eperke Dóra Merkel, et al.

    Due to its heterogeneous clinical picture and lengthy evolution, the management of type B aortic dissection represents a clinical challenge, often calling for complex strategies combining medical, endovascular, and open surgical strategies. We present the case of a 45-year-old female who had previously suffered a complicated type B aortic dissection requiring a femoro-femoral crossover bypass and further conservative treatment. Seven years later, due to an aneurysmal development, a staged descending aortic management was strategized, beginning with the implantation of a frozen elephant trunk device due to an insufficient proximal landing zone for endovascular repair. However, the development of a distal stent graft-induced new entry complicated the dissection and led to the formation of a second false lumen, thus prompting an expedited hybrid reconstruction. We describe a hybrid repair strategy tailored to the patient’s particular aortic anatomic conformation, combining ilio-visceral debranching and thoracic endovascular aortic repair. Due to a lack of consensus on the ideal management strategy for type B aortic dissection, an individualized approach conducted by an experienced aortic team may generate the best outcome. The appropriate timing and planning of the intervention are the keys to successful results in complex type B aortic dissection cases with an elaborate anatomic conformation.


  • Open Access

    What do patients find on the Internet when looking for information about percutaneous coronary intervention? A multi-language cross-sectional assessment (Preprint)

    by Cristina M Șulea, Valentin Nadasan, Tatiana Ursachi, Paul C Toboltoc, Theodora Benedek

    BACKGROUND The Internet provides general users with wide access to medical information. However, regulating and controlling the quality and reliability of the immense volume of available data is challenging, therefore generating concerns about the consequences of inaccurate healthcare-related documentation. Several tools have been proposed in an effort to increase the transparency and overall trustworthiness of medical information present online. OBJECTIVE To analyze and compare the quality and reliability of information about percutaneous coronary intervention on English, German, Hungarian, Romanian, and Russian language websites. METHODS Following a rigorous protocol, 125 websites were selected, 25 for each language subsample. The websites were assessed concerning their general characteristics, compliance with a set of eEurope 2002 credibility criteria, and quality of the informational content (namely completeness and accuracy), based on a topic-specific benchmark. Completeness and accuracy were graded independently by two evaluators. Scores were reported on a scale from 0 to 10. The five language subsamples were compared regarding credibility, completeness, and accuracy. Correlations between credibility scores on the one hand, and completeness and accuracy scores, on the other hand, were tested within each language subsample. RESULTS The websites’ compliance with credibility criteria was average at best with scores between 3.0 and 6.0. In matters of completeness and accuracy, the website subsets qualified as poor or average, with scores ranging from 2.4 to 4.6 and 3.6 to 5.3, respectively. English language websites scored significantly higher in all three aspects, followed by German and Hungarian language websites. Only German language websites showed a significant correlation between credibility and completeness. CONCLUSIONS The quality of websites in English, German, Hungarian, Romanian, and Russian language about percutaneous coronary intervention was rather inadequate and may raise concerns regarding their impact on informed decision-making. Using credibility criteria as indicators of information quality may not be warranted as credibility scores were only exceptionally correlated with content quality.

  • Open Access

    Blood‐filled cyst of the tricuspid valve: Multiple cardiac disorders, one surgical case

    by Cristina M. Șulea, Bálint Lakatos, Attila Kovács, Kálmán Benke, Ferenc I. Suhai, Emese Csulak, Eperke Merkel, Beáta Nagy, István Hartyánszky, Béla Merkely, et al.

    Background Intracardiac blood cysts are an exceedingly rare occurrence in adulthood. Detailed imaging modalities aid in the diagnosis of such incidental lesions and procedure planning. Methods We report the case of a 51-year-old male accusing dyspnea on exertion as a sole symptom which led to the discovery of multiple cardiac anomalies, namely, severe aortic valve insufficiency on a bicuspid aortic valve, ascending aortic aneurysm, a cystic mass on the tricuspid valve, patent foramen ovale, and an occluded right coronary artery. Results The disorders were managed in a single surgical intervention, the resected mass being confirmed as a blood cyst. Conclusions Our case presents a unique association of cardiac disorders, including a highly uncommon intracardiac blood-filled cyst, and underlines the importance of multimodality imaging and interdisciplinary approach in the successful management of such complex cases.