KJKarl E. Jandrey

Karl E. Jandrey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karl E. Jandrey has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cocreating a Responsive Organization: Disclosure and Responsivity in Veterinary Ophthalmology

    by Amanda R. Steidlmayer, Karl E. Jandrey

    Diversity, equity, and inclusion (DEI) have become defining priorities within veterinary ophthalmology, as reflected in editorial leadership, association‐level initiatives, and professional development programs. To translate these professional commitments into daily practice requires more than isolated efforts by individual practitioners. This paper proposes disclosure–responsivity cycles as a practical framework to empower leaders to embed DEI concepts into their daily operations. Disclosure is an individual's decision to share personal or professional information (e.g., acknowledge medical errors or reveal identity characteristics). Responsivity describes the degree to which individuals feel supported after disclosure, both interpersonally and organizationally. Research shows that when organizations are consistently responsive, disclosure reduces psychological strain, builds trust, and enhances inclusivity. The key challenge, therefore, is to cocreate organizations that support disclosure with fair and reliable responsivity. Drawing on organizational theory, change management, and veterinary literature, this paper identifies four domains where disclosure–responsivity cycles can be institutionalized: shared vision, communication channels, competency development, and policy transparency. Together, these domains create interdependent systems that embed DEI into daily practice. For veterinary ophthalmologists, this framework offers a path to cultivate organizations that are adaptive, inclusive, and resilient.

  • Adverse Childhood Experiences, Psychological Distress, and Resilience in Health Professions Students

    by Andrés F. Sciolla, Cara M. Sandholdt, Karl E. Dvm Jandrey, Margaret Rea, Elizabeth I. RN Rice, Machelle D. Wilson, Michael S. Wilkes

    Purpose: To determine the relationship between adverse childhood experiences (ACEs), social disadvantage, psychological distress, and resilience in graduate health professions students. Method: This study includes cross-sectional analyses from a longitudinal survey of medical, veterinary, and advanced practice provider students at matriculation to the University of California Davis in July 2019. The survey contained an expanded Adverse Childhood Experiences Questionnaire (ACEs-14), a measure of psychological distress (the Medical Student Well-Being Index [MSWBI]), and the Brief Resilience Scale. Responses were linked to demographics, including markers of social disadvantage (female gender, underrepresented in medicine [URM] status, and first-generation college graduate [first-gen] status). The relationships between ACEs, social disadvantage, psychological distress, and resilience were tested using linear or logistic regression. Results: Complete survey responses were provided from 240 of 357 students (67% completion rate). About two-thirds of students (67%, 161/240) reported ≥ 1 ACE, while a quarter (25%, 60/240) reported ≥ 4 ACEs. URM and first-gen students had higher odds of reporting ≥ 4 ACEs (odds ratio [OR] = 1.56; P = .049 and OR = 2.63; P < .001, respectively) than their nondisadvantaged peers based on binary logistic regression analysis. Higher ACEs-14 scores were associated with higher psychological distress scores ( P < .001). The majority of students reported normal or high resilience (normal: 76%, 183/240; high: 10%, 25/240) regardless of ACEs-14 scores. There was not a statistically significant relationship between ACEs-14 scores and resilience scores ( P = .936). Conclusions: Health professions students from some socially disadvantaged backgrounds at this institution reported statistically significantly higher ACEs-14 scores than their nondisadvantaged peers. Childhood adversity was associated with increased psychological distress but not with low resilience. Implications for equity- and trauma-informed health professions education and interventions are discussed.


  • Open Access

    Effects of a single subcutaneous dose of enoxaparin on veterinary viscoelastic coagulation monitor variables in healthy cats: Double blind, placebo controlled cross-over trial

    by Ivayla D. Yozova, Michael S. Kent, Karl E. Jandrey

    Background: Cats placed on anticoagulant medication require frequent monitoring. The veterinary viscoelastic coagulation monitor (VCM-Vet) could provide a convenient and cost-effective monitoring, enabling therapeutic decision making. Hypothesis/Objectives: Enoxaparin will lead to changes in VCM-Vet variables and these will correlate with antiXa activity. Animals: Twenty-one healthy cats. Methods: Cats were randomized to receive either enoxaparin (1 mg/kg) subcutaneously or 0.9% NaCl (equal volume) and crossed over with a 7-day washout period. The investigators were blinded to group allocation until data analysis. Jugular blood samples were drawn at time 0, and 2, 4, and 8 hours after injection for VCM-Vet analysis within 2 min of collection. Citrated plasma was frozen at −80°C for antiXa activity analysis. A Generalized Linear Model was completed to assess changes between baseline measurements and all time points. Results: Significant differences between the enoxaparin-treated cats and controls at for T0h and T2h were found and presented as mean ± SD for clotting time (enoxaparin, 593.4 ± 78.0 s; control, 448.5 ± 50.3 s, P < .001), clot formation time (enoxaparin, 183.1 ± 41.7 s; control, 155.4 ± 28.0 s, P = .001), and alpha angle (enoxaparin, 52.4 ± 6.1°; control, 56.9 ± 3.7 s, P = .003). AntiXa activity was significantly different between T0 and all other timepoints for the enoxaparin group (P < .001). There was no correlation between changes in clotting time and antiXa activity. Conclusions and Clinical Importance: The VCM-Vet detects a difference at 2 hours after single-dose enoxaparin administration and it can be useful for anticoagulant therapy monitoring in cats.


  • Disrupt the status quo

    by Karl E. Jandrey

  • Prospective investigation of factors associated with success on the American College of Veterinary Emergency and Critical Care certification examination (2016‐2018)

    by Robert Goggs, Marie Kerl, Karl E. Jandrey, Julien Guillaumin

    Objective To assess the association of candidate attributes and residency training factors with success on the American College of Veterinary Emergency and Critical Care (ACVECC) board certification examination and to develop multivariable models of first-attempt success. Design Prospective survey-based study. Setting Post-assessment ACVECC examination candidates. Animals None. Interventions None. Measurements and main results Comprehensive surveys were distributed to ACVECC examination candidates in 2016 to 2018 after completion of their assessments, but prior to publication of examination results. Unique anonymous candidate identification numbers were used to match survey responses to outcome data from the office of the ACVECC Executive Secretary. After curation to retain only the first response from each candidate, there were 97 unique candidate responses available for analysis. Univariate analyses identified multiple factors associated with first-attempt success and multiple differences between academic and private practice residency programs. Multivariable logistic regression modeling suggested that 5 factors were independently associated with first-attempt success on the ACVECC examination, specifically younger age, more weeks of study prior to the examination, training at a facility with more ACVECC Diplomates, training at a facility with more ACVECC residents, and having no requirement to manage both Emergency Room (ER) and Critical Care (CC) cases simultaneously. Conclusions Numerous resident and training center factors are associated with success in the ACVECC board certification examination. Residents and training centers might be able to use these data to enhance training, but caution must be exercised because these data are associative only.


  • Comparison of healthy blood donor Greyhounds and non‐Greyhounds using a novel point‐of‐care viscoelastic coagulometer

    by Johnson Chang, Karl E. Jandrey, Julie W. Burges, Michael S. Kent

    Objective: To measure and compare viscoelastic coagulation in 2 canine blood donor populations using a novel, point‐of‐care device (VCM Vet Analyzer, VCM).Design: Cohort study.Setting: Academic and commercial veterinary blood banks.Animals: Non‐Greyhounds from community‐based blood donor program and Greyhounds from a blood bank colony.Intervention: Blood was collected from all dogs via direct venipuncture for a complete hemogram, biochemistry, and point‐of‐care viscoelastic coagulation.Measurement and main results: All biochemical measurements for all dogs in Group NG (n = 38, non‐Greyhounds) and Group G (n = 53, Greyhounds) were within local reference intervals. Hematology data showed significant statistical differences between groups in hemoglobin, RBC, platelet, and WBC concentrations. Group G demonstrated lower maximum clot firmness (MCF) with 17 VCM units (26 VCM units in Group NG), increased lysis with 30 VCM units at 30 minutes (LI30) and 27 VCM units at 45 minutes (LI45) (86 VCM units LI30 and 85 VCM units LI45 in Group NG), and decreased amplitude of 13 VCM units 10 minutes (A10) after clot time (CT) and 6 VCM units 20 minutes after CT (A20) (18 VCM units [A10] and 22 VCM units [A20] in Group NG).Conclusion: This study found differences between healthy Greyhound and non‐Greyhound blood donors in measures of clot strength and fibrinolysis as measured by the VCM. Whereas Greyhound have unique hematologic and hemostatic profiles, these measured viscoelastic differences are important to note prior to and following surgical intervention to aid in clinical decision‐making if bleeding complications develop.


  • An in vitro study of canine cryopoor plasma to correct vitamin K–dependent coagulopathy in dogs

    by Hilvy Cheung, Karl E. Jandrey, Julie Burges, Marjory Brooks, Michael S. Kent

    Objective: To compare the efficacy of fresh frozen plasma (FFP) with cryopoor plasma (CPP) to treat vitamin K–dependent factor deficiency in a canine in vitro setting.Design: In vitro laboratory study.Setting: University veterinary medical teaching hospital.Animals: Seven units of FFP and 6 units of CPP from unique canine donors from the university veterinary blood bank.Interventions: Canine FFP was adsorbed by oral barium sulfate suspension to mimic vitamin K–dependent coagulopathy. A sequential mixing study was completed by adding FPP or CPP to the adsorbed plasma. Measurements of prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, and factor activities of factors II, VII, and IX (FII, FVII, and FIX) were compared between the 2 treatment groups.Measurements and main results: When comparing the sequential addition of CPP or FPP to adsorbed plasma, the following had no statistical significance: PT (P = 0.94), aPTT (P = 0.66), FII (P = 0.05), and FIX (P = 0.90). There was a dose‐dependent decrease with PT and aPTT and a dose‐dependent increase with FII and FIX. In contrast, after the addition of either CPP or FFP, there was a significant difference between the treatment groups for the concentration of fibrinogen (P = 0.005) and activity of FVII (P = 0.044), with FFP resulting in a greater concentration of fibrinogen and CPP resulting in a greater concentration of FVII. Measurements of factor X (FX) were initially included in the study but were later excluded because FX appeared to be continually adsorbed even after the addition of CPP or FFP.Conclusions: CPP partially corrected the coagulation times and concentration of vitamin K–dependent coagulation factors to the same degree as FFP. CPP, generally less expensive than FFP, may provide an alternative treatment option for vitamin K–dependent coagulopathies, although in vivo testing is needed.


  • Establishment of a reference interval for a novel viscoelastic coagulometer and comparison with thromboelastography in healthy cats

    by Tommaso Rosati, Karl E. Jandrey, Julie W. Burges, Michael S. Kent

    Background: Viscoelastic analysis provides information on the dynamics and strength of clot formation as well as clot stability. A novel point‐of‐care viscoelastic test (Viscoelastic Coagulation Monitor Vet, VCM Vet) could be more cost‐effective, simpler to use, and more portable than thromboelastography (TEG).Objectives: The primary aim of this study was to establish a feline reference interval (RI) for the VCM Vet. A secondary aim was to compare VCM Vet analysis with TEG in healthy cats.Methods: Fifty‐six healthy cats were enrolled in this study. Linear regression was completed to determine whether age and CBC parameters were associated with the VCM Vet parameters and if TEG parameters were correlated with VCM Vet data. Statistical significance was set at P < .05.Results: Fifty‐three VCM Vet tracings were used to determine RIs for healthy cats. The determined RIs were: clot time (CT) 104‐438 seconds; clot formation time (CFT) 104.5‐488 seconds; alpha angle (AA) 30.5°‐70°; a10 13.8‐32.7 VCM units; a20 19.2‐40.1 VCM units; maximum clot formation (MCF) 22.5‐44.8 VCM units; Lysis Index 30 (Li30) 92.9%‐100.9%; and Lysis Index 45 (Li45) 92%‐100%. Linear regression identified a strong positive correlation between the CT and R‐time measured using the VCM Vet and TEG methods, respectively; no other parameters were correlated.Conclusions: The use of VCM Vet is feasible in cats, and we determined the first described feline RIs for this test. In general, the VCM Vet data did not correlate with TEG in healthy cats.


  • Severe hypernatremia and transient azotemia in a cat following inadvertent intravenous administration of a commercial polyethylene glycol solution

    by Sabrina N. Hoehne, Casey J. Kohen, Birgit Puschner, Ingrid Gennity, Simon P. Hagley, Kate S. Farrell, Karin Unger, Laura A. Cagle, Karl E. Jandrey

    Objective: To describe the clinical signs, clinicopathologic abnormalities, treatment, and outcome after IV administration of polyethylene glycol 3350 (PEG3350) in a cat.Case Summary: A cat was inadvertently administered 6 g/kg of PEG3350 in electrolyte solution, IV, resulting in severe hypernatremia (203 mmol/L), diffuse encephalopathy, hemolysis, and moderate azotemia. The hemolysis and acute kidney injury observed immediately following PEG3350 administration resolved with supportive care. Administration of IV and oral electrolyte‐free water slowly corrected the hypernatremia and the neurologic signs subsequently improved. Complete resolution of clinical signs was documented one month following hospital discharge. The PEG3350 concentrations in serum, plasma, and urine samples confirmed toxic exposure to PEG3350. Efficacy of treatment was evident by decreasing concentrations of PEG3350 in serum after the first 24 hours of treatment. Renal elimination of PEG3350 was significant and PEG3350 was still detected in the urine 17 days after exposure.New Information Provided: This is the first report to describe the clinical signs and clinicopathologic abnormalities in a cat intoxicated with IV PEG3350. Potential pathophysiologic mechanisms are discussed, and the successful supportive medical treatment is outlined.