Wenqi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenqi Huang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Daniel Rueckert
Technical University of Munich (TUM) and TUM University Hospital
6 shared publications- Daniel Rueckert
Department of Computing, Imperial College London, London, United Kingdom
6 shared publications - Kerstin Hammernik
School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
5 shared publications - Dong Liang
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences
4 shared publications Gastao Cruz
University of Michigan
4 shared publications- Jing Cheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
4 shared publications
Latest Publications
- 26 September 2026
- Published by Springer Nature
- p. 188-198
Gabor Primitives for Accelerated Cardiac Cine MRI Reconstruction
- 26 September 2026
- Published by Springer Nature
- p. 188-198
Gabor Primitives for Accelerated Cardiac Cine MRI Reconstruction
- Open Access
- 29 November 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 109, 103890
PISCO: Self-supervised k-space regularization for improved neural implicit k-space representations of dynamic MRI
- 29 November 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 109, 103890
Open AccessPISCO: Self-supervised k-space regularization for improved neural implicit k-space representations of dynamic MRI
- 21 September 2025
- Published by Springer Nature
- p. 481-490
Physics-Informed Implicit Neural Representations for Joint B0 Estimation and Echo Planar Imaging
- 21 September 2025
- Published by Springer Nature
- p. 481-490
Physics-Informed Implicit Neural Representations for Joint B0 Estimation and Echo Planar Imaging
- 3 August 2025
- Published by Springer Nature
- p. 168-183
Subspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
- 3 August 2025
- Published by Springer Nature
- p. 168-183
Subspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
- Open Access
PISCO: Self-Supervised k-Space Regularization for Improved Neural Implicit k-Space Representations of Dynamic MRI
Neural implicit k-space representations (NIK) have shown promising results for dynamic magnetic resonance imaging (MRI) at high temporal resolutions. Yet, reducing acquisition time, and thereby available training data, results in severe performance drops due to overfitting. To address this, we introduce a novel self-supervised k-space loss function $\mathcal{L}_\mathrm{PISCO}$, applicable for regularization of NIK-based reconstructions. The proposed loss function is based on the concept of parallel imaging-inspired self-consistency (PISCO), enforcing a consistent global k-space neighborhood relationship without requiring additional data. Quantitative and qualitative evaluations on static and dynamic MR reconstructions show that integrating PISCO significantly improves NIK representations. Particularly for high acceleration factors (R$\geq$54), NIK with PISCO achieves superior spatio-temporal reconstruction quality compared to state-of-the-art methods. Furthermore, an extensive analysis of the loss assumptions and stability shows PISCO's potential as versatile self-supervised k-space loss function for further applications and architectures. Code is available at: https://github.com/compai-lab/2025-pisco-spiekerOpen AccessPISCO: Self-Supervised k-Space Regularization for Improved Neural Implicit k-Space Representations of Dynamic MRI
Neural implicit k-space representations (NIK) have shown promising results for dynamic magnetic resonance imaging (MRI) at high temporal resolutions. Yet, reducing acquisition time, and thereby available training data, results in severe performance drops due to overfitting. To address this, we introduce a novel self-supervised k-space loss function $\mathcal{L}_\mathrm{PISCO}$, applicable for regularization of NIK-based reconstructions. The proposed loss function is based on the concept of parallel imaging-inspired self-consistency (PISCO), enforcing a consistent global k-space neighborhood relationship without requiring additional data. Quantitative and qualitative evaluations on static and dynamic MR reconstructions show that integrating PISCO significantly improves NIK representations. Particularly for high acceleration factors (R$\geq$54), NIK with PISCO achieves superior spatio-temporal reconstruction quality compared to state-of-the-art methods. Furthermore, an extensive analysis of the loss assumptions and stability shows PISCO's potential as versatile self-supervised k-space loss function for further applications and architectures. Code is available at: https://github.com/compai-lab/2025-pisco-spieker - Open Access
Subspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat variations. To address these challenges, we propose a reconstruction framework based on subspace implicit neural representations for real-time cardiac cine MRI of continuously sampled radial data. This approach employs two multilayer perceptrons to learn spatial and temporal subspace bases, leveraging the low-rank properties of cardiac cine MRI. Initialized with low-resolution reconstructions, the networks are fine-tuned using spoke-specific loss functions to recover spatial details and temporal fidelity. Our method directly utilizes the continuously sampled radial k-space spokes during training, thereby eliminating the need for binning and non-uniform FFT. This approach achieves superior spatial and temporal image quality compared to conventional binned methods at the acceleration rate of 10 and 20, demonstrating potential for high-resolution imaging of dynamic cardiac events and enhancing diagnostic capability.
Open AccessSubspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat variations. To address these challenges, we propose a reconstruction framework based on subspace implicit neural representations for real-time cardiac cine MRI of continuously sampled radial data. This approach employs two multilayer perceptrons to learn spatial and temporal subspace bases, leveraging the low-rank properties of cardiac cine MRI. Initialized with low-resolution reconstructions, the networks are fine-tuned using spoke-specific loss functions to recover spatial details and temporal fidelity. Our method directly utilizes the continuously sampled radial k-space spokes during training, thereby eliminating the need for binning and non-uniform FFT. This approach achieves superior spatial and temporal image quality compared to conventional binned methods at the acceleration rate of 10 and 20, demonstrating potential for high-resolution imaging of dynamic cardiac events and enhancing diagnostic capability.
- 20 February 2024
- Published by Springer Nature
- p. 82-87
Neural Implicit k-space with Trainable Periodic Activation Functions for Cardiac MR Imaging
- 20 February 2024
- Published by Springer Nature
- p. 82-87
Neural Implicit k-space with Trainable Periodic Activation Functions for Cardiac MR Imaging
- Open Access
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (7) , 2420-2433
Motion-Compensated MR CINE Reconstruction With Reconstruction-Driven Motion Estimation
In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (7) , 2420-2433
Open AccessMotion-Compensated MR CINE Reconstruction With Reconstruction-Driven Motion Estimation
In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments.
- 28 October 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 91, 103017
Unrolled and rapid motion-compensated reconstruction for cardiac CINE MRI
- 28 October 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 91, 103017
Unrolled and rapid motion-compensated reconstruction for cardiac CINE MRI
- 7 October 2023
- Published by Springer Nature
- p. 1-11
Propagation and Attribution of Uncertainty in Medical Imaging Pipelines
- 7 October 2023
- Published by Springer Nature
- p. 1-11
Propagation and Attribution of Uncertainty in Medical Imaging Pipelines