JWJiabin Wang

Jiabin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiabin Wang has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Machine Learning Assisted High Precision Vector Bending Sensor Based on Remodulate LPFG

    by Chong Niu, Yichao Wang, Yanru Kou, Jiabin Wang, Xiaoyang Li, Jiarui Chen, Xinyu Yang, Chunlian Lu, Tao Geng, Weimin Sun

    Vector curvature fiber sensors have significant applications in many fields. Traditional fiber sensors rely on single peak demodulation, which often leads to inaccurate demodulation results. In this letter, a high-precision vector bending fiber sensor named Remodulate long-period fiber grating(Remodulate LPFG) is designed. We use the Residual multilayer perceptron model, which fully utilizes the information of multiple modes in the full spectrum to predict vector curvature. The results of the experiment show that the prediction accuracy is 99.93% with a mean absolute error (MAE) of 1.8° for bending direction measurement and 98.92% with an MAE of 0.04 m −1 for the curvature measurement. Our experiments demonstrate that our model has high precision prediction. The high precision prediction and compacting structure consume Remodulate LPFG can unleash enormous value in engineering applications.


  • Open Access

    Influence of Optical Fiber Parameters on the Speckle Pattern and Spectral Observation in Astronomy

    by Anzhi Wang, Jiabin Wang, Zhaoxv Gan, Gang Yue, Xvdong Chen, Qi Yan, Shengjia Wang, Yunxiang Yan, Tao Geng, Shuang Chen, et al.

    Optical fibers serve as a bridge to transmit starlight into the spectrograph in fiber spectral surveys. Due to the interference between multiple modes supported within the fiber, a granular speckle pattern appears on the end of the fiber and leads to an uneven and random energy distribution in the spectrum. This effect is called mode noise, which reduces the accuracy of high-resolution spectral detection. This work investigates the influence of transmitted mode numbers on speckle patterns by using fibers with different core diameters and numerical apertures. A reciprocating mechanical scrambler is proposed for suppressing near-field speckles with negligible focal ratio degradation. We use centroid offset and radial power spectrum to quantitatively evaluate the characteristics of the speckles with and without scrambling. Experimental results show that more modes in a fiber with a larger core diameter reduce the centroid offset of the speckle and make the energy distribution more uniform. The mechanical mode scrambler significantly reduces the random centroid deviation caused by speckles, which is more obvious for large-core fibers. The standard deviation of centroid offset in 1000-cycle tests for the 160 µm core fiber is only 0.043 µm, which is one-tenth of that for the 16 µm core fiber. However, in solar spectrum measurement using these fibers, small-core fibers can more easily achieve higher spectral resolution and capture more spectral information. Therefore, large-core fibers are suitable for tasks requiring high accuracy, while fibers with a smaller core diameter should be applied for high-precision spectral measurement.


  • Flexible FPI sensor fabricated by fiber end photopolymerization and integration for high sensitivity gas pressure sensing

    by Yanru Kou, Xiaoyang Li, Jiabin Wang, Ze Yu, Chong Niu, Jiarui Chen, Xinyu Yang, Shengjia Wang, Chunlian Lu, Tao Geng, et al.


  • Bioinspired Whisker Sensor Based on Orthometric FBGs for Underwater Applications

    by Jiabin Wang, Anzhi Wang, Chong Niu, Yanru Kou, Jiarui Chen, Xinyu Yang, Shengjia Wang, Tao Geng, Weimin Sun

    The efficient perception of the underwater flow field is of great significance to the development of underwater intelligent equipment. Driven by unique whisker receptors of the harbor seals, this study proposes and demonstrates a bio-inspired whisker sensor based on orthometric Fiber Bragg Grating (BIWS-OFBG). Four FBGs are deployed around an artificial whisker as basic sensing units. The hydrodynamic information is encoded as the wavelength evolution of the FBGs. In the underwater experiment, BIWS-OFBG obtains the vortex street distribution in the bionic fishtail wake. It realizes frequency locking with RMSE of 0.0208 Hz and rotation direction recognition of the vortex with a maximum detection distance of 300 mm. Oscillatory stimulus are also detectable. Based on the theoretical model, we further give the calibrated function to express the relationship between wavelength shift and steady flow velocity. A maximum sensitivity of 0.86 nm/(m/s) is achieved. The suggested device provides a new framework for the design of bionic whisker sensors. Replacing integrated circuits with optical fiber sensing units will greatly enhance the adaptability of sensors in extreme application scenarios.


  • Sensitivity-Adjustable Strain Sensor Based on Shrinking Long Period Fiber Grating

    by Chong Niu, Xiaoyang Li, Jiabin Wang, Jiarui Chen, Yanru Kou, Xinyu Yang, Chunlian Lu, Tao Geng, Weimin Sun

    In this letter, a novel shrinking long period fiber grating (S-LPFG) is designed. This strain sensor is fabricated through mechanical polishing and arc-discharging, allowing for certain control over its sensitivity to strain. The single-mode fiber (SMF) is first preprocessed into a D-shaped fiber (DSF) through polishing. Then, a periodic melting-induced shrinking is applied to the fiber through arc-discharging modulation. The polishing and shrinking enhance the asymmetry of the single-mode fiber. The discharge modulation enables convenient control of the mode order coupling efficiency and the shrinking level of the sensor, thereby effectively controlling and improving the strain sensitivity. The experimental results indicate that strain sensors with three levels of sensitivity, namely high, medium, and low sensitivity, are obtained by controlling the number of discharges. The high strain sensitivity reaches an ultra-high value of 174 pm/ $\mu \varepsilon $ within the range of $0- 100 \; \mu \varepsilon $ . These adjustable sensitivity sensors have great potential for various application scenarios.


  • Laser-induced micro-cavity on a fiber end with a harmonic-Vernier effect for salinity sensing

    by Jiabin Wang, Yanru Kou, Anzhi Wang, Chong Niu, Yimou Zhao, Xingyu Yang, Shengjia Wang, Chunlian Lu, Tao Geng, Weimin Sun


  • Open Access

    SMART: Special-shaped Micro-lens Aimer for Real-time Targeting of multi-object telescopes

    by Anzhi Wang, Jiabin Wang, Zhaoxv Gan, Xingyu Yang, Yunxiang Yan, Shengjia Wang, Qi Yan, Tao Geng, Pengfei Wang, Shuang Chen, et al.

    In the process of acquiring astronomical spectral data, the alignment accuracy between the fiber core in the focal plane and the image of the target star is crucial for multi-target telescopes. This work presents a Special-shaped Micro-lens Aimer for Real-time Targeting (SMART), which combines a special-shaped microlens and a fiber bundle to carry out online alignments and improve the injection efficiency of the fiber. The special-shaped microlens consists of a central plate and six side microlenses. The central plate transfers the signal to the science fiber without focal ratio degradation. The side microlenses focus the leakage light to the feedback fibers and return a misalignment signal. The experiment in the laboratory indicates that the SMART-T system can visually demonstrate the recognition of offsets. The SMART-P system is able to realize the alignment for a variety of seeing cases. Under the condition that the diameter of turbulent star image is 0.2 mm, the corrected injection efficiency is improved to 99.7% of the best injection efficiency of the science fiber. The re-centering accuracy is 0.01 mm.

  • Single-Shot Time-Averaged Shearography for Vibration Strain Mode Shape Visualization

    by Shengjia Wang, Pengyuan Shi, Jianxuan Xiong, Yingjie Feng, Pengfei Huang, Bo Dong, Qing Chang, Jiabin Wang, Steen Grüner Hanson, Shuai Gao

    A single-shot time-averaged shearography system is developed for mechanical vibration sensing. Unlike conventional shearography systems that rely on multiple phase-shifted shearograms to visualize vibration strain mode shapes, our developed shearography system utilizes merely a single frame of shearogram for visualization. The spatial carrier method is employed to convey the information of the vibration strain mode shape within a shearogram, enabling the single-shot visualization in the retrieved binary phase map. To ensure the successful retrieval of the vibration-induced phase, a well-distributed spatial frequency spectrum is established by disentangling the shear operation with the spatial carrier through the creation of two intermediate real images in the system. Physical principle of the single-shot time-averaged shearography, as well as the spatial carrier during the vibration event, is demonstrated, and the generation of the binary phase map induced from the vibration is investigated. A series of preliminary experiments were carried out to verify the feasibility and performance of the developed single-shot time-averaged shearography system.


  • Dual Transverse Electro-Optic Effect Enables Heterodyne Differential Interference Contrast Imaging

    by Shuai Gao, Pengfei Huang, Jianxuan Xiong, Bo Dong, Jiabin Wang, Zhan Gao, Shengjia Wang

    Differential interference contrast (DIC) technique has emerged as a widely utilized tool in the field of biomedical science for label-free imaging of transparent biological samples. Its distinct advantage lies in the avoidance of contrast agents, effectively mitigating concerns related to photobleaching and phototoxicity. However, a fundamental limitation of DIC stems from its qualitative nature and nonlinear response to phase gradients. To address this issue, we present quantitative DIC with our newly established dual transverse electro-optic phase modulation. Our method serves as an add-on module for existing commercial DIC systems, exhibiting compatibility with standard commercial cameras in terms of frame rate, while also eliminating the moving units. By leveraging the dual transverse electro-optic effect, we enable the application of the heterodyne technique for precise phase retrieval within quantitative DIC. Initial experiments demonstrate the quantitative imaging capabilities of our technique on both artificial and biological samples, without the requirement for any exogenous labeling.


  • Lab-on-fiber: laser-induced micro-cavity for a relative humidity measurement

    by Jiabin Wang, Yanru Kou, Anzhi Wang, Jiayu Hao, Chong Niu, Hang Jiang, Haoran Meng, Weimin Sun, Tao Geng

    The lab-on-fiber design philosophy is the foundation for creating high-performance integrated fiber sensors. Hence, this Letter proposes an ultra-compact Fabry–Perot interferometer (FPI) based on a laser-induced micro-cavity (LIMC-FPI) on a fiber end for measuring relative humidity. To our knowledge, this novel approach, named the fiber-end photopolymerization (FEP) technique, is applied to create a micro-cavity. Specifically, a pair of humidity-sensitive polymer pillars and a resin end cap obtained by FEP are integrated to generate the cavity. As the ambient humidity changes, the pillars lengthen or shorten, resulting in the spectral evolution of the LIMC-FPI. A typical humidity sensitivity of 0.18 nm/%RH is obtained experimentally. For monitoring the human breathing process, the LIMC-FPI is responsive in the breathing frequency range of 0.2 to 0.5 Hz, allowing a response and recovery time of less than 0.388 s and 1.171 s, respectively. This work introduces a fresh and cost-effective approach for developing lab-on-fiber concept-based sensors.