Biling Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Biling Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Steve Jiang
University of Texas Southwestern Medical Center
8 shared publications - Dan Nguyen
Medical Artificial Intelligence and Automation Laboratory Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA
7 shared publications - Ti Bai
Medical Artificial Intelligence and Automation (MAIA) Laboratory and Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
5 shared publications - Hengrui Zhao
Medical Artificial Intelligence and Automation Laboratory and Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
3 shared publications - Michael Dohopolski
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
3 shared publications - Austen Maniscalco
Medical Artificial Intelligence and Automation Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
2 shared publications
Latest Publications
- Open Access
- 31 July 2025
- Published by IOP Publishing in Machine Learning: Health
- Vol. 1 (1) , 015004
Geometry-encoded deep learning (GeoDL) framework for real-time 3D dose verification for online adaptive radiotherapy
Accurate and efficient dose verification is vital for online adaptive radiotherapy (ART) while the patient is waiting on the treatment couch. Conventional methods are computationally intensive, limiting ART workflow efficiency and quality. A pilot study successfully illustrated the potential of geometry-encoded deep learning (GeoDL) algorithm for two-dimensional (2D) dose estimation on the central axial plane. This study investigates the feasibility of extending GeoDL for real-time dose verification for the entire three-dimensional (3D) volume of interest, fulfilling the unmet need in real clinical practice. The proposed GeoDL unifies the representation of fluence maps (FMs) and CT images by resolving the treatment delivery geometry of a linear accelerator (LINAC) to ease the burden of learning the complex domain transformation between FMs and CT image. A carefully designed 3D U-Net was trained on the integrated CT-FM volume to estimate the 3D dose distribution for the entire volume of interest, utilizing a combined loss function focusing on prediction errors in both high and low dose regions. The model was trained and validated on 281 prostate cancer cases, with 24 additional cases employed for independent testing. The proposed GeoDL algorithm achieved highly accurate 3D dose estimation in almost real-time. The average γ passing rate (, 10% threshold) for the estimated dose was 99.94% ± 0.15% on testing patients. The mean dose differences for the planning target volume (PTV) and organs at risk (OARs) were 0.93% ± 0.59% and 0.28% ± 0.32%, respectively. The average overall computational time for each testing case is ~35ms. This study demonstrates the feasibility of GeoDL in ultra-fast dose verification for ART, with strong performance in relevant dosimetric metrics across the entire volume of interest, positioning it as a valuable tool for real clinical use.- 31 July 2025
- Published by IOP Publishing in Machine Learning: Health
- Vol. 1 (1) , 015004
Open AccessGeometry-encoded deep learning (GeoDL) framework for real-time 3D dose verification for online adaptive radiotherapy
Accurate and efficient dose verification is vital for online adaptive radiotherapy (ART) while the patient is waiting on the treatment couch. Conventional methods are computationally intensive, limiting ART workflow efficiency and quality. A pilot study successfully illustrated the potential of geometry-encoded deep learning (GeoDL) algorithm for two-dimensional (2D) dose estimation on the central axial plane. This study investigates the feasibility of extending GeoDL for real-time dose verification for the entire three-dimensional (3D) volume of interest, fulfilling the unmet need in real clinical practice. The proposed GeoDL unifies the representation of fluence maps (FMs) and CT images by resolving the treatment delivery geometry of a linear accelerator (LINAC) to ease the burden of learning the complex domain transformation between FMs and CT image. A carefully designed 3D U-Net was trained on the integrated CT-FM volume to estimate the 3D dose distribution for the entire volume of interest, utilizing a combined loss function focusing on prediction errors in both high and low dose regions. The model was trained and validated on 281 prostate cancer cases, with 24 additional cases employed for independent testing. The proposed GeoDL algorithm achieved highly accurate 3D dose estimation in almost real-time. The average γ passing rate (, 10% threshold) for the estimated dose was 99.94% ± 0.15% on testing patients. The mean dose differences for the planning target volume (PTV) and organs at risk (OARs) were 0.93% ± 0.59% and 0.28% ± 0.32%, respectively. The average overall computational time for each testing case is ~35ms. This study demonstrates the feasibility of GeoDL in ultra-fast dose verification for ART, with strong performance in relevant dosimetric metrics across the entire volume of interest, positioning it as a valuable tool for real clinical use. - Open Access
- 14 February 2025
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 6 (1) , 015040
Medical image segmentation assisted with clinical inputs via language encoder in a deep learning framework
Introduction: Auto-segmentation of tumor volumes and organs at risk (OARs) is a critical step in cancer radiotherapy treatment planning, where rapid, precise adjustments to treatment plans are required to match the patient anatomy. Although auto-segmentation has been clinically accepted for most OARs, auto-segmentation of tumor volumes, particularly clinical target volumes (CTVs), remains a challenge. This difficulty arises because images alone are often insufficient to capture the necessary information for accurate delineation of microscopic tumor invasion invisible on the image itself. Methods: We propose a deep learning-based medical image segmentation framework designed to mimic the clinical process of delineating CTVs and OARs. At its core, the model performs precise segmentation of medical images while enhancing accuracy by integrating clinical information in text format. A transformer-based text encoder converts textual clinical data into vectors, which are incorporated into the segmentation process with image features. This integration bridges the gap between traditional automated segmentation methods and clinician-guided, context-rich delineations. The framework’s effectiveness is demonstrated through a prostate segmentation example in the context of radiation therapy for localized prostate cancer, where incorporating clinical context significantly impacts the delineation process. Results: In our experiments, we included additional clinical information potentially influencing clinicians’ prostate segmentation. The results show that our proposed method not only outperforms the baseline model, but also surpasses current state-of-the-art methods, with or without clinical contexts. Furthermore, our method demonstrates high performance even with limited data. Conclusion: This proposed segmentation framework has shown to significantly improve auto-segmentation, particularly for CTVs, in cancer radiotherapy.
- 14 February 2025
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 6 (1) , 015040
Open AccessMedical image segmentation assisted with clinical inputs via language encoder in a deep learning framework
Introduction: Auto-segmentation of tumor volumes and organs at risk (OARs) is a critical step in cancer radiotherapy treatment planning, where rapid, precise adjustments to treatment plans are required to match the patient anatomy. Although auto-segmentation has been clinically accepted for most OARs, auto-segmentation of tumor volumes, particularly clinical target volumes (CTVs), remains a challenge. This difficulty arises because images alone are often insufficient to capture the necessary information for accurate delineation of microscopic tumor invasion invisible on the image itself. Methods: We propose a deep learning-based medical image segmentation framework designed to mimic the clinical process of delineating CTVs and OARs. At its core, the model performs precise segmentation of medical images while enhancing accuracy by integrating clinical information in text format. A transformer-based text encoder converts textual clinical data into vectors, which are incorporated into the segmentation process with image features. This integration bridges the gap between traditional automated segmentation methods and clinician-guided, context-rich delineations. The framework’s effectiveness is demonstrated through a prostate segmentation example in the context of radiation therapy for localized prostate cancer, where incorporating clinical context significantly impacts the delineation process. Results: In our experiments, we included additional clinical information potentially influencing clinicians’ prostate segmentation. The results show that our proposed method not only outperforms the baseline model, but also surpasses current state-of-the-art methods, with or without clinical contexts. Furthermore, our method demonstrates high performance even with limited data. Conclusion: This proposed segmentation framework has shown to significantly improve auto-segmentation, particularly for CTVs, in cancer radiotherapy.
- Open Access
- 23 January 2025
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 6 (1) , 015015
Deep unsupervised clustering for prostate auto-segmentation with and without hydrogel spacer
Introduction. Clinical datasets for training deep learning (DL) models often exhibit high levels of heterogeneity due to differences such as patient characteristics, new medical techniques, and physician preferences. In recent years, hydrogel spacers have been used in some prostate cancer patients receiving radiotherapy to separate the prostate and the rectum to better spare the rectum while achieving adequate dose coverage on the prostate. However, this substantially affects the computed tomography image appearance, which downstream reduced the contouring accuracy of auto-segmentation algorithms. This leads to highly heterogeneous dataset. Methods. To address this issue, we propose to identify underlying clusters within the dataset and use the cluster labels for segmentation. We collected a clinical dataset of 909 patients, including those with two types of hydrogel spacers and those without. First, we trained a DL model to locate the prostate and limit our field of view to the local area surrounding the prostate and rectum. We then used Uniform Manifold Approximation and Projection (UMAP) for dimensionality reduction and employed k-means clustering to assign each patient to a cluster. To leverage this clustered data, we propose a text-guided segmentation model, contrastive language and image pre-training (CLIP)-UNet, which encodes the cluster information using a text encoder and combines the encoded text information with image features for segmentation. Results. The UMAP results indicated up to three clusters within the dataset. CLIP-UNet with cluster information achieved a Dice score of 86.2% compared to 84.4% from the baseline UNet. Additionally, CLIP-UNet outperforms other state-of-the-art models with or without cluster information. Conclusion. Automatic clustering assisted by DL can reveal hidden data clusters in clinical datasets, and CLIP-UNet effectively utilizes clustered labels and achieves higher performance.
- 23 January 2025
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 6 (1) , 015015
Open AccessDeep unsupervised clustering for prostate auto-segmentation with and without hydrogel spacer
Introduction. Clinical datasets for training deep learning (DL) models often exhibit high levels of heterogeneity due to differences such as patient characteristics, new medical techniques, and physician preferences. In recent years, hydrogel spacers have been used in some prostate cancer patients receiving radiotherapy to separate the prostate and the rectum to better spare the rectum while achieving adequate dose coverage on the prostate. However, this substantially affects the computed tomography image appearance, which downstream reduced the contouring accuracy of auto-segmentation algorithms. This leads to highly heterogeneous dataset. Methods. To address this issue, we propose to identify underlying clusters within the dataset and use the cluster labels for segmentation. We collected a clinical dataset of 909 patients, including those with two types of hydrogel spacers and those without. First, we trained a DL model to locate the prostate and limit our field of view to the local area surrounding the prostate and rectum. We then used Uniform Manifold Approximation and Projection (UMAP) for dimensionality reduction and employed k-means clustering to assign each patient to a cluster. To leverage this clustered data, we propose a text-guided segmentation model, contrastive language and image pre-training (CLIP)-UNet, which encodes the cluster information using a text encoder and combines the encoded text information with image features for segmentation. Results. The UMAP results indicated up to three clusters within the dataset. CLIP-UNet with cluster information achieved a Dice score of 86.2% compared to 84.4% from the baseline UNet. Additionally, CLIP-UNet outperforms other state-of-the-art models with or without cluster information. Conclusion. Automatic clustering assisted by DL can reveal hidden data clusters in clinical datasets, and CLIP-UNet effectively utilizes clustered labels and achieves higher performance.
- Open Access
- 11 October 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (4) , 045013
Quality assurance for online adaptive radiotherapy: a secondary dose verification model with geometry-encoded U-Net
In online adaptive radiotherapy (ART), quick computation-based secondary dose verification is crucial for ensuring the quality of ART plans while the patient is positioned on the treatment couch. However, traditional dose verification algorithms are generally time-consuming, reducing the efficiency of ART workflow. This study aims to develop an ultra-fast deep-learning (DL) based secondary dose verification algorithm to accurately estimate dose distributions using computed tomography (CT) and fluence maps (FMs). We integrated FMs into the CT image domain by explicitly resolving the geometry of treatment delivery. For each gantry angle, an FM was constructed based on the optimized multi-leaf collimator apertures and corresponding monitoring units. To effectively encode treatment beam configuration, the constructed FMs were back-projected to 30 cm away from the isocenter with respect to the exact geometry of the treatment machines. Then, a 3D U-Net was utilized to take the integrated CT and FM volume as input to estimate dose. Training and validation were performed on 381 prostate cancer cases, with an additional 40 testing cases for independent evaluation of model performance. The proposed model can estimate dose in ∼ 15 ms for each patient. The average γ passing rate ( 3 % / 2 mm , 10 % threshold) for the estimated dose was 99.9% ± 0.15% on testing patients. The mean dose differences for the planning target volume and organs at risk were 0.07 % ± 0.34 % and 0.48 % ± 0.72 % , respectively. We have developed a geometry-resolved DL framework for accurate dose estimation and demonstrated its potential in real-time online ART doses verification.
- 11 October 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (4) , 045013
Open AccessQuality assurance for online adaptive radiotherapy: a secondary dose verification model with geometry-encoded U-Net
In online adaptive radiotherapy (ART), quick computation-based secondary dose verification is crucial for ensuring the quality of ART plans while the patient is positioned on the treatment couch. However, traditional dose verification algorithms are generally time-consuming, reducing the efficiency of ART workflow. This study aims to develop an ultra-fast deep-learning (DL) based secondary dose verification algorithm to accurately estimate dose distributions using computed tomography (CT) and fluence maps (FMs). We integrated FMs into the CT image domain by explicitly resolving the geometry of treatment delivery. For each gantry angle, an FM was constructed based on the optimized multi-leaf collimator apertures and corresponding monitoring units. To effectively encode treatment beam configuration, the constructed FMs were back-projected to 30 cm away from the isocenter with respect to the exact geometry of the treatment machines. Then, a 3D U-Net was utilized to take the integrated CT and FM volume as input to estimate dose. Training and validation were performed on 381 prostate cancer cases, with an additional 40 testing cases for independent evaluation of model performance. The proposed model can estimate dose in ∼ 15 ms for each patient. The average γ passing rate ( 3 % / 2 mm , 10 % threshold) for the estimated dose was 99.9% ± 0.15% on testing patients. The mean dose differences for the planning target volume and organs at risk were 0.07 % ± 0.34 % and 0.48 % ± 0.72 % , respectively. We have developed a geometry-resolved DL framework for accurate dose estimation and demonstrated its potential in real-time online ART doses verification.
- Open Access
- 1 June 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (2) , 025077
Performance deterioration of deep learning models after clinical deployment: a case study with auto-segmentation for definitive prostate cancer radiotherapy
Our study aims to explore the long-term performance patterns for deep learning (DL) models deployed in clinic and to investigate their efficacy in relation to evolving clinical practices. We conducted a retrospective study simulating the clinical implementation of our DL model involving 1328 prostate cancer patients treated between January 2006 and August 2022. We trained and validated a U-Net-based auto-segmentation model on data obtained from 2006 to 2011 and tested on data from 2012 to 2022, simulating the model’s clinical deployment starting in 2012. We visualized the trends of the model performance using exponentially weighted moving average (EMA) curves. Additionally, we performed Wilcoxon Rank Sum Test and multiple linear regression to investigate Dice similarity coefficient (DSC) variations across distinct periods and the impact of clinical factors, respectively. Initially, from 2012 to 2014, the model showed high performance in segmenting the prostate, rectum, and bladder. Post-2015, a notable decline in EMA DSC was observed for the prostate and rectum, while bladder contours remained stable. Key factors impacting the prostate contour quality included physician contouring styles, using various hydrogel spacers, CT scan slice thickness, MRI-guided contouring, and intravenous (IV) contrast (p < 0.0001, p < 0.0001, p = 0.0085, p = 0.0012, p < 0.0001, respectively). Rectum contour quality was notably influenced by factors such as slice thickness, physician contouring styles, and the use of various hydrogel spacers. The quality of the bladder contour was primarily affected by IV contrast. The deployed DL model exhibited a substantial decline in performance over time, aligning with the evolving clinical settings.
- 1 June 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (2) , 025077
Open AccessPerformance deterioration of deep learning models after clinical deployment: a case study with auto-segmentation for definitive prostate cancer radiotherapy
Our study aims to explore the long-term performance patterns for deep learning (DL) models deployed in clinic and to investigate their efficacy in relation to evolving clinical practices. We conducted a retrospective study simulating the clinical implementation of our DL model involving 1328 prostate cancer patients treated between January 2006 and August 2022. We trained and validated a U-Net-based auto-segmentation model on data obtained from 2006 to 2011 and tested on data from 2012 to 2022, simulating the model’s clinical deployment starting in 2012. We visualized the trends of the model performance using exponentially weighted moving average (EMA) curves. Additionally, we performed Wilcoxon Rank Sum Test and multiple linear regression to investigate Dice similarity coefficient (DSC) variations across distinct periods and the impact of clinical factors, respectively. Initially, from 2012 to 2014, the model showed high performance in segmenting the prostate, rectum, and bladder. Post-2015, a notable decline in EMA DSC was observed for the prostate and rectum, while bladder contours remained stable. Key factors impacting the prostate contour quality included physician contouring styles, using various hydrogel spacers, CT scan slice thickness, MRI-guided contouring, and intravenous (IV) contrast (p < 0.0001, p < 0.0001, p = 0.0085, p = 0.0012, p < 0.0001, respectively). Rectum contour quality was notably influenced by factors such as slice thickness, physician contouring styles, and the use of various hydrogel spacers. The quality of the bladder contour was primarily affected by IV contrast. The deployed DL model exhibited a substantial decline in performance over time, aligning with the evolving clinical settings.
- Open Access
Region Specific Optimization (RSO)-based Deep Interactive Registration
Medical image registration is a fundamental and vital task which will affect the efficacy of many downstream clinical tasks. Deep learning (DL)-based deformable image registration (DIR) methods have been investigated, showing state-of-the-art performance. A test time optimization (TTO) technique was proposed to further improve the DL models' performance. Despite the substantial accuracy improvement with this TTO technique, there still remained some regions that exhibited large registration errors even after many TTO iterations. To mitigate this challenge, we firstly identified the reason why the TTO technique was slow, or even failed, to improve those regions' registration results. We then proposed a two-levels TTO technique, i.e., image-specific optimization (ISO) and region-specific optimization (RSO), where the region can be interactively indicated by the clinician during the registration result reviewing process. For both efficiency and accuracy, we further envisioned a three-step DL-based image registration workflow. Experimental results showed that our proposed method outperformed the conventional method qualitatively and quantitatively.
Open AccessRegion Specific Optimization (RSO)-based Deep Interactive Registration
Medical image registration is a fundamental and vital task which will affect the efficacy of many downstream clinical tasks. Deep learning (DL)-based deformable image registration (DIR) methods have been investigated, showing state-of-the-art performance. A test time optimization (TTO) technique was proposed to further improve the DL models' performance. Despite the substantial accuracy improvement with this TTO technique, there still remained some regions that exhibited large registration errors even after many TTO iterations. To mitigate this challenge, we firstly identified the reason why the TTO technique was slow, or even failed, to improve those regions' registration results. We then proposed a two-levels TTO technique, i.e., image-specific optimization (ISO) and region-specific optimization (RSO), where the region can be interactively indicated by the clinician during the registration result reviewing process. For both efficiency and accuracy, we further envisioned a three-step DL-based image registration workflow. Experimental results showed that our proposed method outperformed the conventional method qualitatively and quantitatively.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (11) , 2965-2975
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
Low-dose computed tomography (LDCT) is desirable for both diagnostic imaging and image-guided interventions. Denoisers are widely used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art performance and are becoming mainstream methods. However, there are two challenges to using DL-based denoisers: 1) a trained model typically does not generate different image candidates with different noise-resolution tradeoffs, which are sometimes needed for different clinical tasks; and 2) the model’s generalizability might be an issue when the noise level in the testing images differs from that in the training dataset. To address these two challenges, in this work, we introduce a lightweight optimization process that can run on top of any existing DL-based denoiser during the testing phase to generate multiple image candidates with different noise-resolution tradeoffs suitable for different clinical tasks in real time. Consequently, our method allows users to interact with the denoiser to efficiently review various image candidates and quickly pick the desired one; thus, we termed this method deep interactive denoiser (DID). Experimental results demonstrated that DID can deliver multiple image candidates with different noise-resolution tradeoffs and shows great generalizability across various network architectures, as well as training and testing datasets with various noise levels.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (11) , 2965-2975
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
Low-dose computed tomography (LDCT) is desirable for both diagnostic imaging and image-guided interventions. Denoisers are widely used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art performance and are becoming mainstream methods. However, there are two challenges to using DL-based denoisers: 1) a trained model typically does not generate different image candidates with different noise-resolution tradeoffs, which are sometimes needed for different clinical tasks; and 2) the model’s generalizability might be an issue when the noise level in the testing images differs from that in the training dataset. To address these two challenges, in this work, we introduce a lightweight optimization process that can run on top of any existing DL-based denoiser during the testing phase to generate multiple image candidates with different noise-resolution tradeoffs suitable for different clinical tasks in real time. Consequently, our method allows users to interact with the denoiser to efficiently review various image candidates and quickly pick the desired one; thus, we termed this method deep interactive denoiser (DID). Experimental results demonstrated that DID can deliver multiple image candidates with different noise-resolution tradeoffs and shows great generalizability across various network architectures, as well as training and testing datasets with various noise levels.
- Open Access
- 1 January 2021
- Published by Nexus Press B. V. in Journal of Artificial Intelligence for Medical Sciences
- Vol. 2 (1-2) , 33-43
Deep High-Resolution Network for Low-Dose X-Ray CT Denoising
Low-dose computed tomography (LDCT) is clinically desirable because it reduces the radiation dose to patients. However, the quality of LDCT images is often suboptimal because of the inevitable strong quantum noise. Because of their unprecedented success in computer vision, deep learning (DL)-based techniques have been used for LDCT denoising. Despite DL models' promising ability to remove noise, researchers have observed that the resolution of DL-denoised images is compromised, which decreases their clinical value. To mitigate this problem, in this work, we developed a more effective denoiser by introducing a high-resolution network (HRNet). HRNet consists of multiple branches of subnetworks that extract multiscale features that are fused together later, which substantially enhances the quality of the generated features and improves denoising performance. Experimental results demonstrated that the introduced HRNet-based denoiser outperformed the benchmarked U-Net–based denoiser, as it provided superior image resolution preservation and comparable, if not better, noise suppression. Quantitative evaluation in terms of root-mean-squared errors (RMSEs)/structure similarity index (SSIM) showed that the HRNet-based denoiser improve these values from 113.80/0.550 (LDCT) to 55.24/0.745 (HRNet), which outperformed the 59.87/0.712 for the U-Net–based denoiser.
- 1 January 2021
- Published by Nexus Press B. V. in Journal of Artificial Intelligence for Medical Sciences
- Vol. 2 (1-2) , 33-43
Open AccessDeep High-Resolution Network for Low-Dose X-Ray CT Denoising
Low-dose computed tomography (LDCT) is clinically desirable because it reduces the radiation dose to patients. However, the quality of LDCT images is often suboptimal because of the inevitable strong quantum noise. Because of their unprecedented success in computer vision, deep learning (DL)-based techniques have been used for LDCT denoising. Despite DL models' promising ability to remove noise, researchers have observed that the resolution of DL-denoised images is compromised, which decreases their clinical value. To mitigate this problem, in this work, we developed a more effective denoiser by introducing a high-resolution network (HRNet). HRNet consists of multiple branches of subnetworks that extract multiscale features that are fused together later, which substantially enhances the quality of the generated features and improves denoising performance. Experimental results demonstrated that the introduced HRNet-based denoiser outperformed the benchmarked U-Net–based denoiser, as it provided superior image resolution preservation and comparable, if not better, noise suppression. Quantitative evaluation in terms of root-mean-squared errors (RMSEs)/structure similarity index (SSIM) showed that the HRNet-based denoiser improve these values from 113.80/0.550 (LDCT) to 55.24/0.745 (HRNet), which outperformed the 59.87/0.712 for the U-Net–based denoiser.