Yuda Hadiwijaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuda Hadiwijaya has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kusumiyati Kusumiyati
Universitas Padjadjaran
12 shared publications Ine Elisa Putri
7 shared publicationsAgus Arip Munawar
6 shared publicationsKusumiyati Kusumiyati
Universitas Padjadjaran
4 shared publicationsS Mubarok
Department of Agronomy, Agriculture Faculty, Universitas Padjadjaran, Sumedang 45363, Indonesia
4 shared publicationsI E Putri
3 shared publications
Latest Publications
- Open Access
- 20 November 2025
- Published by Elsevier in Applied Food Research
- Vol. 5 (2)
Water deficit-induced biochemical alterations and Vis/NIR spectral signatures in shallots
- 20 November 2025
- Published by Elsevier in Applied Food Research
- Vol. 5 (2)
Open AccessWater deficit-induced biochemical alterations and Vis/NIR spectral signatures in shallots
- 13 September 2025
- Published by Elsevier in Food and Humanity
- Vol. 5
Spectroscopy in food and agriculture: A critical review of applications and adoption challenges
- 13 September 2025
- Published by Elsevier in Food and Humanity
- Vol. 5
Spectroscopy in food and agriculture: A critical review of applications and adoption challenges
- Open Access
- 15 January 2025
- Published by Wiley in International Journal of Food Science
- Vol. 2025 (1) , 3277288
Quality Assurance of Total Carotenoids and Quercetin in Marigold Flowers ( Tagetes erecta L.) as Edible Flowers
Marigold flowers, which are also known as Tagetes erecta L., are widely recognized for their bright colors and health benefits. Therefore, the purpose of this research was to investigate the quality of total carotenoid content (TCC) and quercetin in marigold flowers, specifically the edible ones, using visible near‐infrared spectroscopy (Vis‐NIRS) technology. Both bioactive compounds in these flowers were assessed using Vis‐NIRS. The technology is considered to be a rapid and non‐destructive method for evaluating the quality of agricultural products. To ensure accuracy in the evaluation, Vis‐NIRS was validated against conventional methods such as spectrophotometry and chromatography. The results showed that the use of Vis‐NIRS helped to accurately determine the levels of TCC and quercetin in marigold flowers. Based on the analysis results, the best accuracy values for TCC were as follows: the correlation coefficient of the calibration set ( R cal ) was 0.94, the root mean square error of the calibration set (RMSEC) was 125.57, the correlation coefficient of the prediction set ( R pred ) was 0.87, the root mean square error of the prediction set (RMSEP) was 129.35, and the ratio of prediction to deviation (RPD) was 2.77. For quercetin, the best accuracy values were: R cal was 0.96, RMSEC was 1.63, R pred was 0.88, RMSEP was 2.37, and RPD was 2.09. These results demonstrate that the method provides a reliable alternative to destructive method. The research showed that Vis‐NIRS served as a reliable quality assurance tool for assessing bioactive compounds in marigold flowers.
- 15 January 2025
- Published by Wiley in International Journal of Food Science
- Vol. 2025 (1) , 3277288
Open AccessQuality Assurance of Total Carotenoids and Quercetin in Marigold Flowers ( Tagetes erecta L.) as Edible Flowers
Marigold flowers, which are also known as Tagetes erecta L., are widely recognized for their bright colors and health benefits. Therefore, the purpose of this research was to investigate the quality of total carotenoid content (TCC) and quercetin in marigold flowers, specifically the edible ones, using visible near‐infrared spectroscopy (Vis‐NIRS) technology. Both bioactive compounds in these flowers were assessed using Vis‐NIRS. The technology is considered to be a rapid and non‐destructive method for evaluating the quality of agricultural products. To ensure accuracy in the evaluation, Vis‐NIRS was validated against conventional methods such as spectrophotometry and chromatography. The results showed that the use of Vis‐NIRS helped to accurately determine the levels of TCC and quercetin in marigold flowers. Based on the analysis results, the best accuracy values for TCC were as follows: the correlation coefficient of the calibration set ( R cal ) was 0.94, the root mean square error of the calibration set (RMSEC) was 125.57, the correlation coefficient of the prediction set ( R pred ) was 0.87, the root mean square error of the prediction set (RMSEP) was 129.35, and the ratio of prediction to deviation (RPD) was 2.77. For quercetin, the best accuracy values were: R cal was 0.96, RMSEC was 1.63, R pred was 0.88, RMSEP was 2.37, and RPD was 2.09. These results demonstrate that the method provides a reliable alternative to destructive method. The research showed that Vis‐NIRS served as a reliable quality assurance tool for assessing bioactive compounds in marigold flowers.
- Open Access
- 10 October 2024
- Published by Elsevier in Case Studies in Chemical and Environmental Engineering
- Vol. 10
Transforming gotu kola (Centella asiatica L.) chemical properties inspection through advanced spectroscopy technology
- 10 October 2024
- Published by Elsevier in Case Studies in Chemical and Environmental Engineering
- Vol. 10
Open AccessTransforming gotu kola (Centella asiatica L.) chemical properties inspection through advanced spectroscopy technology
- Open Access
- 1 January 2022
- Published by American Institute of Mathematical Sciences (AIMS) in AIMS Agriculture and Food
- Vol. 7 (2) , 312-325
Global model for in-field monitoring of sugar content and color of melon pulp with comparative regression approach
The development of the global model is an important part of research involving the quality prediction of agricultural commodities using visible/near-infrared (Vis/NIR) spectroscopy due to its efficiency and effectiveness. The Vis/NIR was used in this study to develop a global model and to evaluate the sugar content and pulp color, which are the main determinants of ripeness and quality of melons. Furthermore, it also provides a comparison between linear and nonlinear regression using partial least squares regression (PLSR) and support vector machine regression (SVMR), respectively. The model accuracy was determined by ratio of performance to deviation (RPD). The results showed that there were good model accuracy values in some parameters, such as SSC (2.14), glucose (1.59), sucrose (2.31), a* (2.97), and b* (2.49), while the fructose (1.35) and L* (1.06) modeling showed poor prediction accuracy. The best model for SSC was developed using PLSR, while that of fructose, glucose, sucrose, L*, a*, and b* were obtained from SVMR. Therefore, Vis/NIR spectroscopy can be used as an alternative method to monitor sugar content and pulp color of a melon, but with some limitations, such as the low accuracy in predicting certain variables, such as the L* and fructose.
- 1 January 2022
- Published by American Institute of Mathematical Sciences (AIMS) in AIMS Agriculture and Food
- Vol. 7 (2) , 312-325
Open AccessGlobal model for in-field monitoring of sugar content and color of melon pulp with comparative regression approach
The development of the global model is an important part of research involving the quality prediction of agricultural commodities using visible/near-infrared (Vis/NIR) spectroscopy due to its efficiency and effectiveness. The Vis/NIR was used in this study to develop a global model and to evaluate the sugar content and pulp color, which are the main determinants of ripeness and quality of melons. Furthermore, it also provides a comparison between linear and nonlinear regression using partial least squares regression (PLSR) and support vector machine regression (SVMR), respectively. The model accuracy was determined by ratio of performance to deviation (RPD). The results showed that there were good model accuracy values in some parameters, such as SSC (2.14), glucose (1.59), sucrose (2.31), a* (2.97), and b* (2.49), while the fructose (1.35) and L* (1.06) modeling showed poor prediction accuracy. The best model for SSC was developed using PLSR, while that of fructose, glucose, sucrose, L*, a*, and b* were obtained from SVMR. Therefore, Vis/NIR spectroscopy can be used as an alternative method to monitor sugar content and pulp color of a melon, but with some limitations, such as the low accuracy in predicting certain variables, such as the L* and fructose.
- Open Access
- 1 November 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 922 (1)
Prediction of water content and soluble solids content of ‘manalagi’ apples using near infrared spectroscopy
The purpose of the research was to predict quality attributes of ‘manalagi’ apples using near infrared spectroscopy (NIRS). The desired quality attributes were water content and soluble solids content. Spectra data collection was performed at wavelength of 702 to 1065 nm using a Nirvana AG410 spectrometer. The original spectra were enhanced using orthogonal signal correction (OSC). The regression approaches used in the study were partial least squares regression (PLSR) and principal component regression (PCR). The results showed that water content prediction acquired coefficient of determination in calibration set (R2cal) of 0.81, coefficient of determination in prediction set (R2pred) of 0.61, root mean squares error of calibration set (RMSEC) of 0.009, root mean squares of prediction set (RMSEP) of 0.020, and ratio performance to deviation (RPD) of 1.62, while soluble solids content prediction displayed R2cal, R2pred, RMSEC, RMSEP, and RPD of 0.79, 0.85, 0.474, 0.420, and 2.69, respectively. These findings indicated that near infrared spectroscopy could be used as an alternative technique to predict water content and soluble solids content of ‘manalagi’ apples.
- 1 November 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 922 (1)
Open AccessPrediction of water content and soluble solids content of ‘manalagi’ apples using near infrared spectroscopy
The purpose of the research was to predict quality attributes of ‘manalagi’ apples using near infrared spectroscopy (NIRS). The desired quality attributes were water content and soluble solids content. Spectra data collection was performed at wavelength of 702 to 1065 nm using a Nirvana AG410 spectrometer. The original spectra were enhanced using orthogonal signal correction (OSC). The regression approaches used in the study were partial least squares regression (PLSR) and principal component regression (PCR). The results showed that water content prediction acquired coefficient of determination in calibration set (R2cal) of 0.81, coefficient of determination in prediction set (R2pred) of 0.61, root mean squares error of calibration set (RMSEC) of 0.009, root mean squares of prediction set (RMSEP) of 0.020, and ratio performance to deviation (RPD) of 1.62, while soluble solids content prediction displayed R2cal, R2pred, RMSEC, RMSEP, and RPD of 0.79, 0.85, 0.474, 0.420, and 2.69, respectively. These findings indicated that near infrared spectroscopy could be used as an alternative technique to predict water content and soluble solids content of ‘manalagi’ apples.
- Open Access
- 8 October 2021
- Published by Elsevier in Data in Brief
- Vol. 39, 107458
Enhanced visible/near-infrared spectroscopic data for prediction of quality attributes in Cucurbitaceae commodities
- 8 October 2021
- Published by Elsevier in Data in Brief
- Vol. 39, 107458
Open AccessEnhanced visible/near-infrared spectroscopic data for prediction of quality attributes in Cucurbitaceae commodities
- Open Access
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 644 (1) , 012001
Application of spectra pre-treatments on firmness assessment of intact sapodilla using vis-nir spectroscopy
This study aimed to obtain the best calibration model from various spectra pre-treatment methods to assess sapodilla fruit firmness using vis-nir spectroscopy. Before the spectra data measurement, samples were treated with storage of 0, 5 and 10 days at room temperature. Spectra data measurement was carried out using the NirVana AG410 visible and near infrared spectrometer from 312 to 1050 nm with interval of 3 nm. RAW spectra were pre-treated using the multiplicative scatter correction (MSC), standard normal variate (SNV), and Savitzky-Golay first derivative (dg1) with 9 points of smoothing. The calibration model was developed using PLS (partial least squares) method. Validation was done by K fold cross validation method. The results showed the MSC and SNV spectra were able to eliminate noises of RAW spectra, whereas in the dg1 spectra, noises were still visible. The best model was acquired by SNV spectra with R2 (coefficient of determination) of calibration and validation of 0.882 and 0.870, root mean square error of calibration (RMSEC) and root mean square error of cross validation (RMSECV) values of 2.92 and 3.08, and the ratio of performance to deviation (RPD) of 2.76. The result indicated the spectra pre-treatments were able to improve the accuracy of calibration model on assessment of sapodilla fruit firmness.
- 1 January 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 644 (1) , 012001
Open AccessApplication of spectra pre-treatments on firmness assessment of intact sapodilla using vis-nir spectroscopy
This study aimed to obtain the best calibration model from various spectra pre-treatment methods to assess sapodilla fruit firmness using vis-nir spectroscopy. Before the spectra data measurement, samples were treated with storage of 0, 5 and 10 days at room temperature. Spectra data measurement was carried out using the NirVana AG410 visible and near infrared spectrometer from 312 to 1050 nm with interval of 3 nm. RAW spectra were pre-treated using the multiplicative scatter correction (MSC), standard normal variate (SNV), and Savitzky-Golay first derivative (dg1) with 9 points of smoothing. The calibration model was developed using PLS (partial least squares) method. Validation was done by K fold cross validation method. The results showed the MSC and SNV spectra were able to eliminate noises of RAW spectra, whereas in the dg1 spectra, noises were still visible. The best model was acquired by SNV spectra with R2 (coefficient of determination) of calibration and validation of 0.882 and 0.870, root mean square error of calibration (RMSEC) and root mean square error of cross validation (RMSECV) values of 2.92 and 3.08, and the ratio of performance to deviation (RPD) of 2.76. The result indicated the spectra pre-treatments were able to improve the accuracy of calibration model on assessment of sapodilla fruit firmness.