Abdelrazek M. Askar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelrazek M. Askar has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Alaa S. Amin
Chemistry Department, Faculty of Science, Benha University, Benha, Egypt
2 shared publications - Hesham H. El-Feky
Chemistry Department, Faculty of Science, Benha University, Benha, Egypt
2 shared publications Mai Aish
Chemistry Department, Faculty of Science, Port Said University, Port Said, Egypt
1 shared publication- Reem F. Alshehri
Chemistry department, College of Science& Arts, Taibah University, Saudi Arabia
1 shared publication
Latest Publications
- 18 September 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 305, 123424
Utilization of a novel PVC- optical sensor for high sensitive and selective determination of zinc ion in real samples
- 18 September 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 305, 123424
Utilization of a novel PVC- optical sensor for high sensitive and selective determination of zinc ion in real samples
- Open Access
- 28 October 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (56) , 35300-35310
Quantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
Growing concerns about the possible toxicity of silver to aquatic organisms, bacteria, and humans have led to newly issued regulations by the United States Environmental Protection Agency (US EPA) and the Food and Drug Administration (FDA) regarding the use of silver. However, the increase in bacterial resistance to antibiotics has led to a resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). For Ag+ ion detection, a highly sensitive and reversible optical sensor has been established. The optode relies on a novel Schiff base, namely 2-[(benzo[d]thiazol-2-ylimino)methyl]phenol (BTMP) immobilized within PVC film and also incorporated with tris(2-ethylhexyl)phosphate (TEHP) and Aliquat 336 as an ion carrier. Under optimum conditions (i.e. pH 8.5), the proposed sensor displayed a linear response to Ag+ over 4.8 × 10−9 to 1.0 × 10−5 M (0.8494–1698.7 μg L−1) with limits of detection and quantification of 1.5 × 10−9 and 4.8 × 10−9 M (0.2548 and 0.8494 μg L−1), respectively. The sensor's response time was found to be 8.0 min. The sensor was applied successfully to determine Ag+ ion in some real samples, including food, biological, water, and environmental samples.
- 28 October 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (56) , 35300-35310
Open AccessQuantification of silver in several samples using a new ionophore polymer membrane as an optical sensor
Growing concerns about the possible toxicity of silver to aquatic organisms, bacteria, and humans have led to newly issued regulations by the United States Environmental Protection Agency (US EPA) and the Food and Drug Administration (FDA) regarding the use of silver. However, the increase in bacterial resistance to antibiotics has led to a resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). For Ag+ ion detection, a highly sensitive and reversible optical sensor has been established. The optode relies on a novel Schiff base, namely 2-[(benzo[d]thiazol-2-ylimino)methyl]phenol (BTMP) immobilized within PVC film and also incorporated with tris(2-ethylhexyl)phosphate (TEHP) and Aliquat 336 as an ion carrier. Under optimum conditions (i.e. pH 8.5), the proposed sensor displayed a linear response to Ag+ over 4.8 × 10−9 to 1.0 × 10−5 M (0.8494–1698.7 μg L−1) with limits of detection and quantification of 1.5 × 10−9 and 4.8 × 10−9 M (0.2548 and 0.8494 μg L−1), respectively. The sensor's response time was found to be 8.0 min. The sensor was applied successfully to determine Ag+ ion in some real samples, including food, biological, water, and environmental samples.