Bharat Singh Rawat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bharat Singh Rawat has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Peter Welsch
The University of Liverpool
7 shared publications - Benjamin Rienäcker
University of Liverpool
6 shared publications - Adam Linek
Institute of Physics, Faculty of Physics, Astronomy, and Informatics, Nicolaus Copernicus University in Toruń, Grudziadzka 5, 87-100 Torun, Poland
5 shared publications - Antoine Camper
University of Oslo
5 shared publications - Fabrizio Castelli
INFN Milano
5 shared publications - Francesco Guatieri
Research Neutron Source Heinz Maier-Leibnitz (FRM II), Technical University of Munich, Lichtenbergstr. 1 Garching bei München, 85748 Bayern Germany
5 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (3) , 35
Invasiveness Study of Supersonic Gas-Curtain-Based Ionization Profile Monitor for Medical Accelerators
In proton beam therapy, ideally, beam monitoring should be non-invasive to provide online real-time feedback, such that the total dose delivered to the patient is not significantly affected. The invasiveness of the Supersonic Gas-Curtain-Based Ionization Profile Monitor (SGC-IPM) system was quantified by perturbation in beam current and transverse beam profile parameters induced by the supersonic gas-curtain for a 4.9–5.3 keV electron beam, representing a worst-case scenario where perturbations can be more easily observable. The experimentally measured gas-curtain effects on transverse beam parameters (≤2%), intensity (≤−1%) and beam current (≤−1%) were small in magnitude and largely below resolution limits. To confirm these effects, order-of-magnitude beam–gas interaction approximations were calculated for the experimental energy range, demonstrating negligible energy loss with minor scattering, broadly consistent with the experimental results. Clinical proton beam gas-curtain predictions (70–250 MeV) indicate a further reduction of ∼ compared to the experimental observations. Even under the conservative electron beam conditions used in this study, the observed perturbations were minor or unresolvable and measured effects were significantly smaller than spatial and dosimetry scales relevant to proton radiotherapy. Overall, the experimental measurements and supporting order-of-magnitude estimates demonstrate that the SGC-IPM introduces negligible perturbations to beam parameters and is predicted to provide non-invasive beam profile monitoring for clinical proton beam diagnostics.- 30 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (3) , 35
Open AccessInvasiveness Study of Supersonic Gas-Curtain-Based Ionization Profile Monitor for Medical Accelerators
In proton beam therapy, ideally, beam monitoring should be non-invasive to provide online real-time feedback, such that the total dose delivered to the patient is not significantly affected. The invasiveness of the Supersonic Gas-Curtain-Based Ionization Profile Monitor (SGC-IPM) system was quantified by perturbation in beam current and transverse beam profile parameters induced by the supersonic gas-curtain for a 4.9–5.3 keV electron beam, representing a worst-case scenario where perturbations can be more easily observable. The experimentally measured gas-curtain effects on transverse beam parameters (≤2%), intensity (≤−1%) and beam current (≤−1%) were small in magnitude and largely below resolution limits. To confirm these effects, order-of-magnitude beam–gas interaction approximations were calculated for the experimental energy range, demonstrating negligible energy loss with minor scattering, broadly consistent with the experimental results. Clinical proton beam gas-curtain predictions (70–250 MeV) indicate a further reduction of ∼ compared to the experimental observations. Even under the conservative electron beam conditions used in this study, the observed perturbations were minor or unresolvable and measured effects were significantly smaller than spatial and dosimetry scales relevant to proton radiotherapy. Overall, the experimental measurements and supporting order-of-magnitude estimates demonstrate that the SGC-IPM introduces negligible perturbations to beam parameters and is predicted to provide non-invasive beam profile monitoring for clinical proton beam diagnostics. - Open Access
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Spectrometry of captured highly charged ions produced following antiproton annihilations
We report the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following annihilations of trapped antiprotons in a Penning-Malmberg trap. A multistep nested-trap technique was developed at the AEḡIS experiment at CERN to trap and identify the annihilation-linked ions using external scintillators. The successful capture and mass analysis of helium and argon ions confirm the viability of the approach. This proof-of-principle demonstration establishes the foundation for future high-resolution mass spectrometry of recoil-filtered nuclear annihilation fragments. This methodology could enable studies of antiprotonic atom formation and cascade dynamics, allow the in-trap synthesis of radioactive HCIs, and provide a particularly sensitive probe of the neutron-to-proton composition at the outer periphery of the nucleus.
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Open AccessSpectrometry of captured highly charged ions produced following antiproton annihilations
We report the first capture and time-of-flight spectrometry of highly charged ions (HCIs) produced following annihilations of trapped antiprotons in a Penning-Malmberg trap. A multistep nested-trap technique was developed at the AEḡIS experiment at CERN to trap and identify the annihilation-linked ions using external scintillators. The successful capture and mass analysis of helium and argon ions confirm the viability of the approach. This proof-of-principle demonstration establishes the foundation for future high-resolution mass spectrometry of recoil-filtered nuclear annihilation fragments. This methodology could enable studies of antiprotonic atom formation and cascade dynamics, allow the in-trap synthesis of radioactive HCIs, and provide a particularly sensitive probe of the neutron-to-proton composition at the outer periphery of the nucleus.
- Open Access
- 31 March 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 245
Production of negatively charged atomic ions inside a linear Paul trap for the formation of antiprotonic atoms
- 31 March 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 245
Open AccessProduction of negatively charged atomic ions inside a linear Paul trap for the formation of antiprotonic atoms
- Open Access
- 25 January 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 4
Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy
FLASH radiotherapy requires real-time, non-invasive beam monitoring systems capable of operating under ultra-high dose rate (UHDR) conditions without perturbing the therapeutic beam. In this work, we characterized the extraction system of Supersonic Gas Curtain-based Ionization Profile Monitor (SGC-IPM) for its capabilities as a transverse beam profile and position monitor for FLASH protons. The monitor utilizes a tilted gas curtain intersected by the incident beam, leading to the generation of ions that are extracted through a tailored electrostatic field, and detected using a two stage microchannel plate (MCP) coupled to a phosphor screen and CMOS camera. CST Studio Suite was employed to conduct electrostatic and particle tracking simulations evaluating the ability of the extraction system to measure both beam profile and position. The ion interface, at the interaction region of proton beam and gas curtain, was modeled with realistic proton beam parameters and uniform gas curtain density distributions. The ion trajectory was tracked to evaluate the performance across multiple beam sizes. The simulations suggest that the extraction system can reconstruct transverse beam profiles for different proton beam sizes. Simulations also supported the system’s capability as a beam position monitor within the boundary defined by the beam size, the dimensions of the extraction system, and the height of the gas curtain. Some simulation results were benchmarked against experimental data of 28 MeV proton beam with 70 nA average beam current. This study will further help to optimize the design of the extraction system to facilitate the integration of SGC-IPM in medical accelerators.
- 25 January 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 4
Open AccessCharacterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy
FLASH radiotherapy requires real-time, non-invasive beam monitoring systems capable of operating under ultra-high dose rate (UHDR) conditions without perturbing the therapeutic beam. In this work, we characterized the extraction system of Supersonic Gas Curtain-based Ionization Profile Monitor (SGC-IPM) for its capabilities as a transverse beam profile and position monitor for FLASH protons. The monitor utilizes a tilted gas curtain intersected by the incident beam, leading to the generation of ions that are extracted through a tailored electrostatic field, and detected using a two stage microchannel plate (MCP) coupled to a phosphor screen and CMOS camera. CST Studio Suite was employed to conduct electrostatic and particle tracking simulations evaluating the ability of the extraction system to measure both beam profile and position. The ion interface, at the interaction region of proton beam and gas curtain, was modeled with realistic proton beam parameters and uniform gas curtain density distributions. The ion trajectory was tracked to evaluate the performance across multiple beam sizes. The simulations suggest that the extraction system can reconstruct transverse beam profiles for different proton beam sizes. Simulations also supported the system’s capability as a beam position monitor within the boundary defined by the beam size, the dimensions of the extraction system, and the height of the gas curtain. Some simulation results were benchmarked against experimental data of 28 MeV proton beam with 70 nA average beam current. This study will further help to optimize the design of the extraction system to facilitate the integration of SGC-IPM in medical accelerators.
- Open Access
- 28 August 2025
- Published by MDPI AG in Instruments
- Vol. 9 (3) , 20
Faraday Cups: Principles, Designs, and Applications Across Scientific Disciplines—A Review
Beam diagnostics are essential tools for monitoring the performance of charged particle beams and the safe operation of particle accelerators. The performance of an accelerator is determined by evaluating the properties of beam particles, such as energy, charge, spatial, and temporal density distributions, which require very specific instruments. Faraday Cups (FCs) have emerged as important beam diagnostic devices because of their ability to accurately measure the beam charge and, in some cases, the charge distribution, which can be subsequently used to reconstruct transverse beam profiles. This paper aims to provide a detailed review of FCs, their principles, and their design challenges. FCs have applications in various scientific disciplines that include the measurement of beam current/intensity in particle accelerators, in addition to those for mass spectrometry, beam profiles/total beam currents for broad ion beams, thermonuclear fusion, and antimatter experiments. This review also covers and discusses the versatility of FCs in various scientific disciplines, along with showcasing the technological advancements that include improved collector materials, novel designs, enhanced measurement techniques, and developments in electronics and data acquisition (D.A.Q). A summary of the challenges faced while working with the FCs, such as sensitivity, calibration, and potential errors, is included in this review.
- 28 August 2025
- Published by MDPI AG in Instruments
- Vol. 9 (3) , 20
Open AccessFaraday Cups: Principles, Designs, and Applications Across Scientific Disciplines—A Review
Beam diagnostics are essential tools for monitoring the performance of charged particle beams and the safe operation of particle accelerators. The performance of an accelerator is determined by evaluating the properties of beam particles, such as energy, charge, spatial, and temporal density distributions, which require very specific instruments. Faraday Cups (FCs) have emerged as important beam diagnostic devices because of their ability to accurately measure the beam charge and, in some cases, the charge distribution, which can be subsequently used to reconstruct transverse beam profiles. This paper aims to provide a detailed review of FCs, their principles, and their design challenges. FCs have applications in various scientific disciplines that include the measurement of beam current/intensity in particle accelerators, in addition to those for mass spectrometry, beam profiles/total beam currents for broad ion beams, thermonuclear fusion, and antimatter experiments. This review also covers and discusses the versatility of FCs in various scientific disciplines, along with showcasing the technological advancements that include improved collector materials, novel designs, enhanced measurement techniques, and developments in electronics and data acquisition (D.A.Q). A summary of the challenges faced while working with the FCs, such as sensitivity, calibration, and potential errors, is included in this review.
- Open Access
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eads1176
Real-time antiproton annihilation vertexing with submicrometer resolution
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62 − 0.22 + 0.40 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
- 4 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (14) , eads1176
Open AccessReal-time antiproton annihilation vertexing with submicrometer resolution
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62 − 0.22 + 0.40 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
- Open Access
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
TALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Open AccessTALOS (Total Automation of LabVIEW Operations for Science): A framework for autonomous control systems for complex experiments
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.
- Open Access
- 22 February 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (8) , 083402
Positronium Laser Cooling via the Transition with a Broadband Laser PulseWe report on laser cooling of a large fraction of positronium (Ps) in free flight by strongly saturating the transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived states. The second effect is one-dimensional Doppler cooling of Ps, reducing the cloud’s temperature from 380(20) to 170(20) K. We demonstrate a 58(9)% increase in the fraction of Ps atoms with .- 22 February 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 132 (8) , 083402
Open AccessPositronium Laser Cooling via the Transition with a Broadband Laser PulseWe report on laser cooling of a large fraction of positronium (Ps) in free flight by strongly saturating the transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived states. The second effect is one-dimensional Doppler cooling of Ps, reducing the cloud’s temperature from 380(20) to 170(20) K. We demonstrate a 58(9)% increase in the fraction of Ps atoms with . - 18 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (8) , 2218-2224
Experimental Studies on the Roles of Space Charge Neutralization in a Ring Cusp Ion Source
Experimental studies in a ring cusp ion source are performed for investigating the role of space charge neutralization by measuring ion beam profiles, fluxes of charge exchange ions, and distribution of ion beam neutralizing electrons. The measurements are carried out using the argon ion beam of current 30–60 mA and beam energy 1200 eV. A Faraday cup array (FCA) equipped with filtering electrodes is developed and utilized for measuring the ion beam profiles by filtering out the neutralizing electrons and slow-moving charge exchange ions from the ion beam. The radial flux of charge exchange ions is measured using a flat Faraday probe mounted at a location outside the ion beam. The flat Faraday probe is shielded from the energetic beam ions. The flux of charge exchange ions is studied to assess the effect of space charge neutralization inside the ion beam. The reduction in floating potential observed with improved space charge neutralization is found to correlate with a reduced radial flow of charge exchange ions. The FCA is also utilized to measure the distribution profile of neutralizing electrons in the ion beam by biasing its filtering electrodes and Faraday cups (FCs) at appropriate potentials. The radial profiles of neutralizing electrons are found Gaussian as similar to that of the beam ions. It is suggested that the neutralizing electrons are dispersed as similar to the fast ion distribution in order to accomplish an evenly distributed space charge neutralization.
- 18 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (8) , 2218-2224
Experimental Studies on the Roles of Space Charge Neutralization in a Ring Cusp Ion Source
Experimental studies in a ring cusp ion source are performed for investigating the role of space charge neutralization by measuring ion beam profiles, fluxes of charge exchange ions, and distribution of ion beam neutralizing electrons. The measurements are carried out using the argon ion beam of current 30–60 mA and beam energy 1200 eV. A Faraday cup array (FCA) equipped with filtering electrodes is developed and utilized for measuring the ion beam profiles by filtering out the neutralizing electrons and slow-moving charge exchange ions from the ion beam. The radial flux of charge exchange ions is measured using a flat Faraday probe mounted at a location outside the ion beam. The flat Faraday probe is shielded from the energetic beam ions. The flux of charge exchange ions is studied to assess the effect of space charge neutralization inside the ion beam. The reduction in floating potential observed with improved space charge neutralization is found to correlate with a reduced radial flow of charge exchange ions. The FCA is also utilized to measure the distribution profile of neutralizing electrons in the ion beam by biasing its filtering electrodes and Faraday cups (FCs) at appropriate potentials. The radial profiles of neutralizing electrons are found Gaussian as similar to that of the beam ions. It is suggested that the neutralizing electrons are dispersed as similar to the fast ion distribution in order to accomplish an evenly distributed space charge neutralization.
- Open Access
- 1 December 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (12) , 125103
Measurement system for ion beam profiles using fixed parallel wires and Faraday cup array
The radial profiles of ion current density are measured using a combination of two techniques—fixed parallel wires and a Faraday cup array—in a ring cusp ion source. These measurements are carried out for Ar+ ion beam current in the range of 20–90 mA and energy in the range of 850–1650 eV. Current density profiles near the extraction plane of the ion source are obtained by Abel inversion of the profiles of current measured using the parallel wires. In addition, the Faraday cup array provides radial profiles of ion current density at two different locations along the beam axis. A numerical model is developed and utilized for estimating the beam divergence and focal length from the profiles of ion current density measured using the two techniques. A fixed parallel wire array is established as an effective method for monitoring the ion beam profiles close to the ion source's extraction plane when the ion beam is utilized for other applications. The performance of the two measurement techniques is compared by estimating the ion beam current from the measurement of ion current density with the beam current measured from the power supply.
- 1 December 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (12) , 125103
Open AccessMeasurement system for ion beam profiles using fixed parallel wires and Faraday cup array
The radial profiles of ion current density are measured using a combination of two techniques—fixed parallel wires and a Faraday cup array—in a ring cusp ion source. These measurements are carried out for Ar+ ion beam current in the range of 20–90 mA and energy in the range of 850–1650 eV. Current density profiles near the extraction plane of the ion source are obtained by Abel inversion of the profiles of current measured using the parallel wires. In addition, the Faraday cup array provides radial profiles of ion current density at two different locations along the beam axis. A numerical model is developed and utilized for estimating the beam divergence and focal length from the profiles of ion current density measured using the two techniques. A fixed parallel wire array is established as an effective method for monitoring the ion beam profiles close to the ion source's extraction plane when the ion beam is utilized for other applications. The performance of the two measurement techniques is compared by estimating the ion beam current from the measurement of ion current density with the beam current measured from the power supply.