Alexandre Mendonça Munhoz
Research Subjects
Research Interests
Alexandre Mendonça Munhoz has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Adriana Sayuri Kurogi Ascenço
Aesthetic and Reconstructive Plastic Surgery Service at Hospital de Clínicas, Universidade Federal Do Paraná (UFPR), Curitiba, Brazil
1 shared publicationAlberto Okada
Department of Surgery, Plastic Surgery Division, Cancer Institute of Estado de São Paulo, University of São Paulo School of Medicine , São Paulo, Brazil
1 shared publication- Eduardo Gustavo Pires de Arruda
Departamento de Neurociências e Ciências do Comportamento, Faculdade de Medicina de Ribeirão Preto Universidade de São Paulo São Paulo Brazil
1 shared publication - Eduardo Montag
Plastic Surgery Division, Instituto do Câncer do Estado de São Paulo (ICESP), Member of the Brazilian Society of Plastic Surgery (SBCP), Brazil
1 shared publication - Isac de Castro
Hospital Sírio-Libanês
1 shared publication Isis Juliane Guarezi Nasser
Aesthetic and Reconstructive Plastic Surgery Service at Hospital de Clínicas, Universidade Federal Do Paraná (UFPR), Curitiba, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by RECIMA21 - Revista Cientifica Multidisciplinar in RECIMA21 - Revista Científica Multidisciplinar
- Vol. 2 (10) , e210775
IMPLEMENTAÇÃO E MANUTENÇÃO DA ANTENA DE SATÉLITE ATRAVÉS DO MONITORAMENTO DE LOCOMOTIVAS EM EMPRESA DE TRANSPORTE FERROVIÁRIO
O objetivo é abordar as iniciativas agindo de forma proativa para a melhoria do sistema de satélite e venha a ser totalmente operacional. Este estudo visa superar problemas relacionados a um planejamento ineficiente do sistema, onde a antena de satélite é fixada em um suporte o qual acumula água devido a fazer troca de calor, entre os ambiente interno e externo, neste processo de troca de calor entre os ambientes foi puxado a água acumulada que fica no suporte para dentro de si, gerando assim o problema que está em estudo, a infiltração na antena de satélite. Nas analises realizadas, foi utilizado o programa PRTG Monitor Network para monitorar este processo de funcionamento da mesma, observado o mal funcionamento desta antena, foi retirada esta antena da locomotiva para a análise mais aprofundada, e assim constatado que a mesma saia bastante água de dentro dela, pelo respiro, onde ela faz essa troca de calor. Os resultados experimentais mostraram que ao abrir uma circunferência no meio deste suporte foram eficazes, deixando assim a parte do respiro livre entre os ambientes interno e externo, também a manutenção interna de seus componentes eletrônicos, e por último a validação dos níveis de sinais da antena de satélite.
- 1 November 2021
- Published by RECIMA21 - Revista Cientifica Multidisciplinar in RECIMA21 - Revista Científica Multidisciplinar
- Vol. 2 (10) , e210775
Open AccessIMPLEMENTAÇÃO E MANUTENÇÃO DA ANTENA DE SATÉLITE ATRAVÉS DO MONITORAMENTO DE LOCOMOTIVAS EM EMPRESA DE TRANSPORTE FERROVIÁRIO
O objetivo é abordar as iniciativas agindo de forma proativa para a melhoria do sistema de satélite e venha a ser totalmente operacional. Este estudo visa superar problemas relacionados a um planejamento ineficiente do sistema, onde a antena de satélite é fixada em um suporte o qual acumula água devido a fazer troca de calor, entre os ambiente interno e externo, neste processo de troca de calor entre os ambientes foi puxado a água acumulada que fica no suporte para dentro de si, gerando assim o problema que está em estudo, a infiltração na antena de satélite. Nas analises realizadas, foi utilizado o programa PRTG Monitor Network para monitorar este processo de funcionamento da mesma, observado o mal funcionamento desta antena, foi retirada esta antena da locomotiva para a análise mais aprofundada, e assim constatado que a mesma saia bastante água de dentro dela, pelo respiro, onde ela faz essa troca de calor. Os resultados experimentais mostraram que ao abrir uma circunferência no meio deste suporte foram eficazes, deixando assim a parte do respiro livre entre os ambientes interno e externo, também a manutenção interna de seus componentes eletrônicos, e por último a validação dos níveis de sinais da antena de satélite.
- 1 September 2020
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 41 (6) , NP616-NP630
Impact of Fat Graft Thickness and Harvesting Technique on Adipocyte Viability in a New Porcine Experimental Model: An Immunohistochemical Analysis
Autologous fat grafting (AFG) has been used in surgical practice as a filling method. However, controversies remain on the specifics of this technique. So far, few relevant experimental large animal studies have objectively assessed factors related to AFG integration. This study uses an experimental medium-sized animal model to compare the feasibility of AFG collected using two different techniques with instruments of distinct thicknesses. Twenty minipigs (Sus scropha domesticus) were subjected to AFG harvesting via en bloc resection using 3 (Group I) and 5 mm diameter (Group II) round punch blades (PB) and liposuction (LS) with 3 (Group III) and 5 mm diameter cannulas (Group IV). Both samples were grafted intramuscularly (biceps femoralis). Hematoxylin and eosin (HE) staining was used to identify intact adipocytes, fat necrosis, fibrosis, inflammation, and oil cysts. Immunohistochemical staining (IHC) (perilipin-A, TNF-α, CD31) were utilized to quantify the feasibility of adipocytes, tissue necrosis, neoangiogenesis, respectively. HE analysis showed that fat necrosis/histiocyte presence were significant lower in the AFG harvested using a PB than in LS. For perilipin-A, a statistical difference was observed between subgroups I and III (p=0.001) and I and IV (p=0.004). Instrument diameter was seen to have no effect on graft integration, as seen in comparisons between groups II and III (p=0.059) and II and IV (p=0.132). In this experimental study, fat collected using a PB demonstrated higher adipocyte viability than fat collected with LS. The diameter of the collection instruments, whether PB or LS, had no effect on graft integration.
- 1 September 2020
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 41 (6) , NP616-NP630
Impact of Fat Graft Thickness and Harvesting Technique on Adipocyte Viability in a New Porcine Experimental Model: An Immunohistochemical Analysis
Autologous fat grafting (AFG) has been used in surgical practice as a filling method. However, controversies remain on the specifics of this technique. So far, few relevant experimental large animal studies have objectively assessed factors related to AFG integration. This study uses an experimental medium-sized animal model to compare the feasibility of AFG collected using two different techniques with instruments of distinct thicknesses. Twenty minipigs (Sus scropha domesticus) were subjected to AFG harvesting via en bloc resection using 3 (Group I) and 5 mm diameter (Group II) round punch blades (PB) and liposuction (LS) with 3 (Group III) and 5 mm diameter cannulas (Group IV). Both samples were grafted intramuscularly (biceps femoralis). Hematoxylin and eosin (HE) staining was used to identify intact adipocytes, fat necrosis, fibrosis, inflammation, and oil cysts. Immunohistochemical staining (IHC) (perilipin-A, TNF-α, CD31) were utilized to quantify the feasibility of adipocytes, tissue necrosis, neoangiogenesis, respectively. HE analysis showed that fat necrosis/histiocyte presence were significant lower in the AFG harvested using a PB than in LS. For perilipin-A, a statistical difference was observed between subgroups I and III (p=0.001) and I and IV (p=0.004). Instrument diameter was seen to have no effect on graft integration, as seen in comparisons between groups II and III (p=0.059) and II and IV (p=0.132). In this experimental study, fat collected using a PB demonstrated higher adipocyte viability than fat collected with LS. The diameter of the collection instruments, whether PB or LS, had no effect on graft integration.
- 1 April 2020
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 145 (4) , 868e-869e
Fat Grafting and the Palpable Breast Mass in Implant-Based Breast Reconstruction: Incidence and Implications
- 1 April 2020
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 145 (4) , 868e-869e
Fat Grafting and the Palpable Breast Mass in Implant-Based Breast Reconstruction: Incidence and Implications
- 30 July 2019
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 43 (6) , 1429-1436
Is There a Breast Augmentation Outcome Difference Between Subfascial and Subglandular Implant Placement? A Prospective Randomized Double-Blinded Study
Introduction Subfascial breast augmentation is gaining popularity because of no distortion when the pectoral muscle is contracted and minimizing visualization of the edges of the implant. Although some studies have reported a satisfactory outcome with subfascial technique, it still is controversial the influence of the pectoral fascia and outcome compared to the subglandular technique. Therefore, this prospective randomized study aimed to investigate whether there are clinical/radiological differences between subfascial and subglandular pockets following primary breast augmentation. Methods Twenty patient candidates for primary breast augmentation were recruited. Each patient was selected for subfascial or subglandular pockets in a randomized fashion. Both patient and surgeon were blinded. Clinical and radiological differences were evaluated through five independent surgeons and MRI (capsule, folds, fluids, base and projection). Median follow-up was 12 months. Results Breast consistency (p = 0.24), implant pocket (p = 0.52), symmetry (p = 1), contour, and shape (p = 0.09) demonstrated no statistically significant difference after the surgeons’ assessments at 3 and 12 months after surgery. MRIs demonstrated a larger implant base in the subfascial group (p = 0.024). No differences were observed in capsule thickness (p = 0.42), folds (p = 0.51), fluids (p = 0.28), or projection (0.20). Conclusion The choice between subfascial and subglandular planes shows no clinical differences and can be selected according to individual professional experience, not evidencing any advantages of one over the other. Level of Evidence II This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
- 30 July 2019
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 43 (6) , 1429-1436
Is There a Breast Augmentation Outcome Difference Between Subfascial and Subglandular Implant Placement? A Prospective Randomized Double-Blinded Study
Introduction Subfascial breast augmentation is gaining popularity because of no distortion when the pectoral muscle is contracted and minimizing visualization of the edges of the implant. Although some studies have reported a satisfactory outcome with subfascial technique, it still is controversial the influence of the pectoral fascia and outcome compared to the subglandular technique. Therefore, this prospective randomized study aimed to investigate whether there are clinical/radiological differences between subfascial and subglandular pockets following primary breast augmentation. Methods Twenty patient candidates for primary breast augmentation were recruited. Each patient was selected for subfascial or subglandular pockets in a randomized fashion. Both patient and surgeon were blinded. Clinical and radiological differences were evaluated through five independent surgeons and MRI (capsule, folds, fluids, base and projection). Median follow-up was 12 months. Results Breast consistency (p = 0.24), implant pocket (p = 0.52), symmetry (p = 1), contour, and shape (p = 0.09) demonstrated no statistically significant difference after the surgeons’ assessments at 3 and 12 months after surgery. MRIs demonstrated a larger implant base in the subfascial group (p = 0.024). No differences were observed in capsule thickness (p = 0.42), folds (p = 0.51), fluids (p = 0.28), or projection (0.20). Conclusion The choice between subfascial and subglandular planes shows no clinical differences and can be selected according to individual professional experience, not evidencing any advantages of one over the other. Level of Evidence II This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.