Shikha Binwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shikha Binwal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Shantanu Kumar Karkari
Institute for Plasma Research 1 , Bhat, Gandhinagar, Gujarat 382428
4 shared publications - Jay K. Joshi
Institute for Plasma Research (HBNI), Gandhinagar, Gujarat, India
3 shared publications L. Nair
Jamia Millia Islamia (A Central University) 1 , Jamia Nagar, New Delhi 110025, India
2 shared publicationsH Kabariya
Institute for Plasma Research, Bhat Village, Gandhinagar, Gujarat 382428, India
1 shared publicationLekha Nair
Department of Physics, Jamia Millia Islamia (A Central University), New Delhi, India
1 shared publication- Lekha Nair
Jamia Milia Islamia University, New Delhi, India
1 shared publication
Latest Publications
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (11) , 3582-3588
An Electrical Impedance-Based Technique to Infer Plasma Density in a 13.56-MHz Magnetized Capacitive Coupled RF Discharge
Plasma density in a magnetized, capacitive-coupled, radio frequency (RF) discharge has been determined using the electrical impedance characteristics of the discharge. The effective impedance between the parallel plate electrodes has been treated as an equivalent electric circuit consisting of resistive and reactive components, expressed in terms of high-frequency plasma conductivity. Hence the model is used to connect the externally measured RF voltage, current, and their relative phase to plasma density. Additionally, a triple Langmuir probe (TLP) is used to substantiate the results of the electrical impedance model. The plasma density obtained using the direct probe measurement is found to be in good agreement with those determined from the passive measurements based on electrical impedance of the discharge as outlined in this article.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (11) , 3582-3588
An Electrical Impedance-Based Technique to Infer Plasma Density in a 13.56-MHz Magnetized Capacitive Coupled RF Discharge
Plasma density in a magnetized, capacitive-coupled, radio frequency (RF) discharge has been determined using the electrical impedance characteristics of the discharge. The effective impedance between the parallel plate electrodes has been treated as an equivalent electric circuit consisting of resistive and reactive components, expressed in terms of high-frequency plasma conductivity. Hence the model is used to connect the externally measured RF voltage, current, and their relative phase to plasma density. Additionally, a triple Langmuir probe (TLP) is used to substantiate the results of the electrical impedance model. The plasma density obtained using the direct probe measurement is found to be in good agreement with those determined from the passive measurements based on electrical impedance of the discharge as outlined in this article.
- Open Access
- 1 March 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (3) , 033506
Transverse magnetic field effects on spatial electron temperature distribution in a 13.56 MHz parallel plate capacitive discharge
The effect of a transverse magnetic field on spatial electron temperature Te distribution along the line joining the center of capacitively driven rectangular discharge plates, operated at 13.56 MHz in a push-pull configuration, has been presented. It is found that the electron temperature distribution is almost uniform at low operating pressure (1 Pa). However, as the background pressure increases, the electron temperature tends to peak near the discharge plates. The overall magnitude in Te is also found to increase throughout the volume on account of increasing the background pressure. This experimental observation has been qualitatively depicted by COMSOL Multiphysics® fluid simulation. A plausible explanation has been given to explain the rise in Te due to the combined effect of the magnetic field and background pressure in this setup.
- 1 March 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (3) , 033506
Open AccessTransverse magnetic field effects on spatial electron temperature distribution in a 13.56 MHz parallel plate capacitive discharge
The effect of a transverse magnetic field on spatial electron temperature Te distribution along the line joining the center of capacitively driven rectangular discharge plates, operated at 13.56 MHz in a push-pull configuration, has been presented. It is found that the electron temperature distribution is almost uniform at low operating pressure (1 Pa). However, as the background pressure increases, the electron temperature tends to peak near the discharge plates. The overall magnitude in Te is also found to increase throughout the volume on account of increasing the background pressure. This experimental observation has been qualitatively depicted by COMSOL Multiphysics® fluid simulation. A plausible explanation has been given to explain the rise in Te due to the combined effect of the magnetic field and background pressure in this setup.
- 1 February 2019
- Published by Springer Nature
- p. 603-609
Electrical Discharge Characteristics of Magnetized Capacitive Coupled Plasma
- 1 February 2019
- Published by Springer Nature
- p. 603-609
Electrical Discharge Characteristics of Magnetized Capacitive Coupled Plasma
- 1 March 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (3) , 033506
Passive inference of collision frequency in magnetized capacitive argon discharge
A non-invasive method of determining the collision frequency νm by measuring the net plasma impendence in a magnetized, capacitive-coupled, radio-frequency (rf) discharge circuit is developed. The collision frequency has been analytically expressed in terms of bulk plasma reactance, wherein standard sheath models have been used to estimate the reactance offered due to the capacitive rf sheaths at the discharge plates. The experimental observations suggest that in the un-magnetized case, νm remains constant over a range of rf current but steadily increases as the background pressure reduces. In the magnetized case, the collision frequency has been observed to decay with the increase in rf current while it remains unaffected by the background pressure. A qualitative discussion has been presented to explain these characteristics.
- 1 March 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (3) , 033506
Passive inference of collision frequency in magnetized capacitive argon discharge
A non-invasive method of determining the collision frequency νm by measuring the net plasma impendence in a magnetized, capacitive-coupled, radio-frequency (rf) discharge circuit is developed. The collision frequency has been analytically expressed in terms of bulk plasma reactance, wherein standard sheath models have been used to estimate the reactance offered due to the capacitive rf sheaths at the discharge plates. The experimental observations suggest that in the un-magnetized case, νm remains constant over a range of rf current but steadily increases as the background pressure reduces. In the magnetized case, the collision frequency has been observed to decay with the increase in rf current while it remains unaffected by the background pressure. A qualitative discussion has been presented to explain these characteristics.
- 12 November 2015
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 26 (12) , 125015
Parametric study of a pin-plane probe in moderately magnetized plasma
The application of a planar Langmuir probe in magnetized plasma is found to be problematic due to significant perturbation of plasma along the magnetic field lines intercepting the probe surface. This causes the Ampere–Volts 'I e(U)' characteristics of the probe to deviate from its usual exponential law; in conjunction the electron saturation current I es is significantly reduced. Moreover estimating the electron temperature T e by considering the entire semi-log plot of I e(U) gives ambiguous values of T e. To address this problem, Pitts and Stangeby developed a formula for the reduction factor for I es. This formula depends on a number of uncertain parameters, namely; the ion temperature T +, electron cross-field diffusion coefficient and the local potential hill V h estimated by applying a floating pin probe in the vicinity of the planar probe. Due to implicit dependence of these parameters on T e, the resulting analysis is not straightforward. This paper presents a parametric study of different parameters that influence the characteristics of a planar probe in magnetized plasma. For this purpose a pin-plane probe is constructed and applied in the magnetized plasma column. A comprehensive discussion is presented that highlights the practical methodology of using this technique for extracting useful information of plasma parameters in magnetized plasmas.
- 12 November 2015
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 26 (12) , 125015
Parametric study of a pin-plane probe in moderately magnetized plasma
The application of a planar Langmuir probe in magnetized plasma is found to be problematic due to significant perturbation of plasma along the magnetic field lines intercepting the probe surface. This causes the Ampere–Volts 'I e(U)' characteristics of the probe to deviate from its usual exponential law; in conjunction the electron saturation current I es is significantly reduced. Moreover estimating the electron temperature T e by considering the entire semi-log plot of I e(U) gives ambiguous values of T e. To address this problem, Pitts and Stangeby developed a formula for the reduction factor for I es. This formula depends on a number of uncertain parameters, namely; the ion temperature T +, electron cross-field diffusion coefficient and the local potential hill V h estimated by applying a floating pin probe in the vicinity of the planar probe. Due to implicit dependence of these parameters on T e, the resulting analysis is not straightforward. This paper presents a parametric study of different parameters that influence the characteristics of a planar probe in magnetized plasma. For this purpose a pin-plane probe is constructed and applied in the magnetized plasma column. A comprehensive discussion is presented that highlights the practical methodology of using this technique for extracting useful information of plasma parameters in magnetized plasmas.