Kerry Bradley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kerry Bradley has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Zachary B. Kagan
Nevro Corp, 1800 Bridge Pkwy, Redwood City, CA 94065, USA
3 shared publications - Dong Wang
Nevro Corp, 1800 Bridge Pkwy, Redwood City, CA 94065, USA
2 shared publications - Dongchul Lee
Nevro Corp, 1800 Bridge Pkwy, Redwood City, CA 94065, USA
2 shared publications Kwan Yeop Lee
2 shared publications- Kwan Yeop Lee
Nevro Corp, 1800 Bridge Pkwy, Redwood City, CA 94065, USA
2 shared publications Mayank Gupta
Neuroscience Research Center, LLC, Overland Park, KS, United States
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by Frontiers Media SA in Frontiers in Pain Research
- Vol. 6, 1633424
Extreme pulse dosing of 10 kHz spinal cord stimulation: how low can you go?
Background: Pulse dosing of high frequency spinal cord stimulation at 10 kHz (10 kHz SCS) may offer comparable clinical benefits as continuous 10 kHz SCS, but extreme pulse dosing (EPD) has not been studied.Methods: Patients using an implantable pulse generator (IPG) with 10 kHz SCS to treat chronic back or leg pain were enrolled. After baseline assessments, patients underwent “EPD titration” starting at an EPD setting of 3%. Patients who preferred the EPD tried progressively lower EPD settings (0.6%, 0.3%, 0.14%, 0.06%), each for 7–10 days, until reaching an EPD they did not prefer over that previously tried. Patients were then followed up for 3 months at their lowest preferred EPD. All study visits included assessment of adverse events and patient-reported outcomes, including the numeric rating score (NRS) for pain intensity, Patient Global Impression of Change (PGIC), Oswestry Disability Index (ODI), and the PROMIS-SF for sleep disturbance. Device charging information was uploaded from the IPG at each visit.Results: Eighteen patients completed testing (13 M/5 F; mean age, 61 years); 14 patients (78%) reporting a preferred EPD (at any setting) to standard 10 kHz SCS. Among 18 patients, the most common lowest preferred EPD was 0.14% (28%), followed by 0.06% (22%) and 3% (17%). All post-SCS pain scores were lower than pre-SCS pain scores (median NRS, 8.5 vs. 3.0; p = .004). For overall pain, NRS values did not vary significantly across timepoints after the pre-SCS period (median range, 3.0–4.0; p > .05). Similarly, patient satisfaction, PGIC, ODI, PCS, and PROMIS-SF scores for EPD did not vary significantly from those at baseline. Daily IPG recharge times were significantly shorter using the patient's lowest preferred EPD than at baseline (median minutes, 3.0 vs. 31.8; p = .0001).Conclusions: EPD 10 kHz SCS may offer the same pain relief and quality-of-life benefits as standard 10 kHz SCS, while reducing recharge requirements and potentially lowering the risk of therapy habituation.
- 1 October 2025
- Published by Frontiers Media SA in Frontiers in Pain Research
- Vol. 6, 1633424
Open AccessExtreme pulse dosing of 10 kHz spinal cord stimulation: how low can you go?
Background: Pulse dosing of high frequency spinal cord stimulation at 10 kHz (10 kHz SCS) may offer comparable clinical benefits as continuous 10 kHz SCS, but extreme pulse dosing (EPD) has not been studied.Methods: Patients using an implantable pulse generator (IPG) with 10 kHz SCS to treat chronic back or leg pain were enrolled. After baseline assessments, patients underwent “EPD titration” starting at an EPD setting of 3%. Patients who preferred the EPD tried progressively lower EPD settings (0.6%, 0.3%, 0.14%, 0.06%), each for 7–10 days, until reaching an EPD they did not prefer over that previously tried. Patients were then followed up for 3 months at their lowest preferred EPD. All study visits included assessment of adverse events and patient-reported outcomes, including the numeric rating score (NRS) for pain intensity, Patient Global Impression of Change (PGIC), Oswestry Disability Index (ODI), and the PROMIS-SF for sleep disturbance. Device charging information was uploaded from the IPG at each visit.Results: Eighteen patients completed testing (13 M/5 F; mean age, 61 years); 14 patients (78%) reporting a preferred EPD (at any setting) to standard 10 kHz SCS. Among 18 patients, the most common lowest preferred EPD was 0.14% (28%), followed by 0.06% (22%) and 3% (17%). All post-SCS pain scores were lower than pre-SCS pain scores (median NRS, 8.5 vs. 3.0; p = .004). For overall pain, NRS values did not vary significantly across timepoints after the pre-SCS period (median range, 3.0–4.0; p > .05). Similarly, patient satisfaction, PGIC, ODI, PCS, and PROMIS-SF scores for EPD did not vary significantly from those at baseline. Daily IPG recharge times were significantly shorter using the patient's lowest preferred EPD than at baseline (median minutes, 3.0 vs. 31.8; p = .0001).Conclusions: EPD 10 kHz SCS may offer the same pain relief and quality-of-life benefits as standard 10 kHz SCS, while reducing recharge requirements and potentially lowering the risk of therapy habituation.
- Open Access
- 14 September 2024
- Published by Elsevier in Neuroscience Letters
- Vol. 842, 137990
10 kHz spinal cord stimulation improves metrics of spinal sensory processing in a male STZ rat model of diabetes
- 14 September 2024
- Published by Elsevier in Neuroscience Letters
- Vol. 842, 137990
Open Access10 kHz spinal cord stimulation improves metrics of spinal sensory processing in a male STZ rat model of diabetes
- Open Access
- 18 June 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (6) , 1346
Frequency-Dependent Neural Modulation of Dorsal Horn Neurons by Kilohertz Spinal Cord Stimulation in Rats
Kilohertz high-frequency spinal cord stimulation (kHF-SCS) is a rapidly advancing neuromodulatory technique in the clinical management of chronic pain. However, the precise cellular mechanisms underlying kHF-SCS-induced paresthesia-free pain relief, as well as the neural responses within spinal pain circuits, remain largely unexplored. In this study, using a novel preparation, we investigated the impact of varying kilohertz frequency SCS on dorsal horn neuron activation. Employing calcium imaging on isolated spinal cord slices, we found that extracellular electric fields at kilohertz frequencies (1, 3, 5, 8, and 10 kHz) induce distinct patterns of activation in dorsal horn neurons. Notably, as the frequency of extracellular electric fields increased, there was a clear and significant monotonic escalation in neuronal activity. This phenomenon was observed not only in superficial dorsal horn neurons, but also in those located deeper within the dorsal horn. Our study demonstrates the unique patterns of dorsal horn neuron activation in response to varying kilohertz frequencies of extracellular electric fields, and we contribute to a deeper understanding of how kHF-SCS induces paresthesia-free pain relief. Furthermore, our study highlights the potential for kHF-SCS to modulate sensory information processing within spinal pain circuits. These insights pave the way for future research aimed at optimizing kHF-SCS parameters and refining its therapeutic applications in the clinical management of chronic pain.
- 18 June 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (6) , 1346
Open AccessFrequency-Dependent Neural Modulation of Dorsal Horn Neurons by Kilohertz Spinal Cord Stimulation in Rats
Kilohertz high-frequency spinal cord stimulation (kHF-SCS) is a rapidly advancing neuromodulatory technique in the clinical management of chronic pain. However, the precise cellular mechanisms underlying kHF-SCS-induced paresthesia-free pain relief, as well as the neural responses within spinal pain circuits, remain largely unexplored. In this study, using a novel preparation, we investigated the impact of varying kilohertz frequency SCS on dorsal horn neuron activation. Employing calcium imaging on isolated spinal cord slices, we found that extracellular electric fields at kilohertz frequencies (1, 3, 5, 8, and 10 kHz) induce distinct patterns of activation in dorsal horn neurons. Notably, as the frequency of extracellular electric fields increased, there was a clear and significant monotonic escalation in neuronal activity. This phenomenon was observed not only in superficial dorsal horn neurons, but also in those located deeper within the dorsal horn. Our study demonstrates the unique patterns of dorsal horn neuron activation in response to varying kilohertz frequencies of extracellular electric fields, and we contribute to a deeper understanding of how kHF-SCS induces paresthesia-free pain relief. Furthermore, our study highlights the potential for kHF-SCS to modulate sensory information processing within spinal pain circuits. These insights pave the way for future research aimed at optimizing kHF-SCS parameters and refining its therapeutic applications in the clinical management of chronic pain.
- Open Access
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S693-S694
10KHZ SCS RESTORES MECHANICAL AND THERMAL NEURAL PROCESSING IN A RODENT MODEL OF PAINFUL DIABETIC NEUROPATHY
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S693-S694
Open Access10KHZ SCS RESTORES MECHANICAL AND THERMAL NEURAL PROCESSING IN A RODENT MODEL OF PAINFUL DIABETIC NEUROPATHY
- Open Access
- 1 May 2022
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 15, 1503-1513
Low-Intensity 10 kHz Spinal Cord Stimulation Reduces Behavioral and Neural Hypersensitivity in a Rat Model of Painful Diabetic Neuropathy
Background: Low-intensity 10 kHz spinal cord stimulation (SCS) has been shown to provide pain relief in patients with chronic pain resulting from diabetic peripheral neuropathy (DPN). However to date, there have been no studies of 10 kHz SCS in animal models of diabetes. We aimed to establish correlative data of the effects of this therapy on behavioral and electrophysiological measures in a DPN model. Methods: Twenty-five adult male Sprague-Dawley rats were injected once intraperitoneally with 60 mg/kg streptozotocin (STZ) to induce diabetes over a subsequent 4 w period, while 4 naïve control animals were not injected. After approximately 21 d, 12 of STZ-injected rats had mini epidural SCS leads implanted: 8 received continuous low intensity (∼ 30% motor threshold) 10 kHz SCS, and 4 received sham SCS (0 mA) over 7 d. Behavioral assays (von Frey filament probe of hindpaw) were measured in 18 animals and in vivo dorsal horn electrophysiological studies (receptive field; response to afferent brush, von Frey probe, pinch) were performed in 17 animals. Results: Across behavioral assays of mechanical allodynia and electrophysiological assays of receptive field size and mechanosensitivity, diabetic animals stimulated with 10 kHz SCS showed statistically significant improvements compared to sham SCS. Conclusion: Low-intensity 10 kHz SCS produced several measures associated with a reduction of pain in diabetic rodent models that may help explain the clinical benefits of 10 kHz SCS in patients with painful diabetic neuropathy.
- 1 May 2022
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 15, 1503-1513
Open AccessLow-Intensity 10 kHz Spinal Cord Stimulation Reduces Behavioral and Neural Hypersensitivity in a Rat Model of Painful Diabetic Neuropathy
Background: Low-intensity 10 kHz spinal cord stimulation (SCS) has been shown to provide pain relief in patients with chronic pain resulting from diabetic peripheral neuropathy (DPN). However to date, there have been no studies of 10 kHz SCS in animal models of diabetes. We aimed to establish correlative data of the effects of this therapy on behavioral and electrophysiological measures in a DPN model. Methods: Twenty-five adult male Sprague-Dawley rats were injected once intraperitoneally with 60 mg/kg streptozotocin (STZ) to induce diabetes over a subsequent 4 w period, while 4 naïve control animals were not injected. After approximately 21 d, 12 of STZ-injected rats had mini epidural SCS leads implanted: 8 received continuous low intensity (∼ 30% motor threshold) 10 kHz SCS, and 4 received sham SCS (0 mA) over 7 d. Behavioral assays (von Frey filament probe of hindpaw) were measured in 18 animals and in vivo dorsal horn electrophysiological studies (receptive field; response to afferent brush, von Frey probe, pinch) were performed in 17 animals. Results: Across behavioral assays of mechanical allodynia and electrophysiological assays of receptive field size and mechanosensitivity, diabetic animals stimulated with 10 kHz SCS showed statistically significant improvements compared to sham SCS. Conclusion: Low-intensity 10 kHz SCS produced several measures associated with a reduction of pain in diabetic rodent models that may help explain the clinical benefits of 10 kHz SCS in patients with painful diabetic neuropathy.
- Open Access
- 2 October 2021
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 23 (1) , 152-163
Pulse Dosing of 10-kHz Paresthesia-Independent Spinal Cord Stimulation Provides the Same Efficacy with Substantial Reduction of Device Recharge Time
Objective: This study was designed to assess whether using pulse dosing (PD) (regularly cycled intermittent stimulation) of high-frequency 10-kHz spinal cord stimulation (10-kHz SCS) can reduce device recharge time while maintaining efficacy in patients with chronic intractable back pain with or without leg pain. Design: Prospective, multicenter, observational study. Methods: Patients successfully using 10-kHz SCS at 100%ON (i.e., continuously with no PD) for >3 months were consecutively enrolled. After a 1-week baseline period of documenting their pain twice daily on a 0–10 numerical rating scale (NRS) using 100%ON of their “favorite” program, all subjects were reprogrammed to 14%PD for 10–14 days. If subjects preferred 14%PD to 100%ON, they were programmed to 3%PD; otherwise, they were programmed to 50%PD. Subjects used this next program for another 10–14 days. Subjects then entered a 3-month observational period during which they were requested to use but not limited to their most preferred %PD program. Toward the end of 3 months, subjects completed a 7-day NRS diary and indicated a final %PD program preference. Study endpoints included %PD preference, mean diary NRS by %PD, and daily minutes and patterns of charging. Results: Of 31 subjects completing the study, 81% preferred less than 100%ON. Among the subjects, 39% preferred 3%PD, 32% preferred 14%PD, 10% preferred 50%PD, and 19% preferred 100%ON. Average daily charge durations were 8.3 ± 3.1 minutes for 3%PD, 13.9 ± 4.9 minutes for 14%PD, 26.2 ± 7.4 minutes for 50%PD, and 43.8 ± 10.9 minutes for 100%ON. Regression modeling suggested that pain relief was weighted as more than twice as influential as charging in preference for reduced %PD. Conclusions: This prospective study suggests that 10-kHz SCS therapy with PD may be successfully used in a large majority of 10-kHz SCS responders, maintaining efficacy while reducing device charging time by nearly two thirds.
- 2 October 2021
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 23 (1) , 152-163
Open AccessPulse Dosing of 10-kHz Paresthesia-Independent Spinal Cord Stimulation Provides the Same Efficacy with Substantial Reduction of Device Recharge Time
Objective: This study was designed to assess whether using pulse dosing (PD) (regularly cycled intermittent stimulation) of high-frequency 10-kHz spinal cord stimulation (10-kHz SCS) can reduce device recharge time while maintaining efficacy in patients with chronic intractable back pain with or without leg pain. Design: Prospective, multicenter, observational study. Methods: Patients successfully using 10-kHz SCS at 100%ON (i.e., continuously with no PD) for >3 months were consecutively enrolled. After a 1-week baseline period of documenting their pain twice daily on a 0–10 numerical rating scale (NRS) using 100%ON of their “favorite” program, all subjects were reprogrammed to 14%PD for 10–14 days. If subjects preferred 14%PD to 100%ON, they were programmed to 3%PD; otherwise, they were programmed to 50%PD. Subjects used this next program for another 10–14 days. Subjects then entered a 3-month observational period during which they were requested to use but not limited to their most preferred %PD program. Toward the end of 3 months, subjects completed a 7-day NRS diary and indicated a final %PD program preference. Study endpoints included %PD preference, mean diary NRS by %PD, and daily minutes and patterns of charging. Results: Of 31 subjects completing the study, 81% preferred less than 100%ON. Among the subjects, 39% preferred 3%PD, 32% preferred 14%PD, 10% preferred 50%PD, and 19% preferred 100%ON. Average daily charge durations were 8.3 ± 3.1 minutes for 3%PD, 13.9 ± 4.9 minutes for 14%PD, 26.2 ± 7.4 minutes for 50%PD, and 43.8 ± 10.9 minutes for 100%ON. Regression modeling suggested that pain relief was weighted as more than twice as influential as charging in preference for reduced %PD. Conclusions: This prospective study suggests that 10-kHz SCS therapy with PD may be successfully used in a large majority of 10-kHz SCS responders, maintaining efficacy while reducing device charging time by nearly two thirds.
- Open Access
- 18 May 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (5) , 568
Differential Modulation of Dorsal Horn Neurons by Various Spinal Cord Stimulation Strategies
New strategies for spinal cord stimulation (SCS) for chronic pain have emerged in recent years, which may work better via different analgesic mechanisms than traditional low-frequency (e.g., 50 Hz) paresthesia-based SCS. To determine if 10 kHz and burst SCS waveforms might have a similar mechanistic basis, we examined whether these SCS strategies at intensities ostensibly below sensory thresholds would modulate spinal dorsal horn (DH) neuronal function in a neuron type-dependent manner. By using an in vivo electrophysiological approach in rodents, we found that low-intensity 10 kHz SCS, but not burst SCS, selectively activates inhibitory interneurons in the spinal DH. This study suggests that low-intensity 10 kHz SCS may inhibit pain-sensory processing in the spinal DH by activating inhibitory interneurons without activating DC fibers, resulting in paresthesia-free pain relief, whereas burst SCS likely operates via other mechanisms.
- 18 May 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (5) , 568
Open AccessDifferential Modulation of Dorsal Horn Neurons by Various Spinal Cord Stimulation Strategies
New strategies for spinal cord stimulation (SCS) for chronic pain have emerged in recent years, which may work better via different analgesic mechanisms than traditional low-frequency (e.g., 50 Hz) paresthesia-based SCS. To determine if 10 kHz and burst SCS waveforms might have a similar mechanistic basis, we examined whether these SCS strategies at intensities ostensibly below sensory thresholds would modulate spinal dorsal horn (DH) neuronal function in a neuron type-dependent manner. By using an in vivo electrophysiological approach in rodents, we found that low-intensity 10 kHz SCS, but not burst SCS, selectively activates inhibitory interneurons in the spinal DH. This study suggests that low-intensity 10 kHz SCS may inhibit pain-sensory processing in the spinal DH by activating inhibitory interneurons without activating DC fibers, resulting in paresthesia-free pain relief, whereas burst SCS likely operates via other mechanisms.