James Ranjith Kumar Rajasekaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Ranjith Kumar Rajasekaran has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Balasubramaniam Natarajan
Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA
3 shared publications - Anil Pahwa
Electrical and Computer Engineering Department, Kansas State University, Manhattan, KS, USA
2 shared publications - Biplab Sikdar
National University of Singapore
2 shared publications - Amanjot Kaur
School of Computer Science and Informatics, Cardiff University
1 shared publication Balasubramaniam Natarajan
Kansas State University
1 shared publication- Deepa Kundur
University of Toronto
1 shared publication
Latest Publications
- Open Access
- 4 September 2025
- Published by Association for Computing Machinery (ACM) in ACM Computing Surveys
- Vol. 58 (1) , 1-32
Cybersecurity Challenges in the EV Charging Ecosystem
The growing adoption of intelligent Electric Vehicles (EVs) has also created an opportunity for malicious actors to initiate attacks on the EV infrastructure, which can include a number of data exchange protocols across the various entities that are part of the EV charging ecosystem. These protocols possess a range of underlying vulnerabilities that attackers can exploit to disrupt the regular flow of information and energy. While researchers have considered vulnerabilities of particular components within an EV charging ecosystem, there is still a notable gap in vulnerability analysis of charging protocols and the potential threats to these. We investigate threat vectors within the most widely adopted protocols used in EV infrastructure, explore the potential impact of cyberattacks and suggest various mitigation techniques investigated in literature. Potential future research directions are also identified.
- 4 September 2025
- Published by Association for Computing Machinery (ACM) in ACM Computing Surveys
- Vol. 58 (1) , 1-32
Open AccessCybersecurity Challenges in the EV Charging Ecosystem
The growing adoption of intelligent Electric Vehicles (EVs) has also created an opportunity for malicious actors to initiate attacks on the EV infrastructure, which can include a number of data exchange protocols across the various entities that are part of the EV charging ecosystem. These protocols possess a range of underlying vulnerabilities that attackers can exploit to disrupt the regular flow of information and energy. While researchers have considered vulnerabilities of particular components within an EV charging ecosystem, there is still a notable gap in vulnerability analysis of charging protocols and the potential threats to these. We investigate threat vectors within the most widely adopted protocols used in EV infrastructure, explore the potential impact of cyberattacks and suggest various mitigation techniques investigated in literature. Potential future research directions are also identified.
- 27 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (4) , 3449-3452
Online Bad Data Detection in Compressed Sensing-Based Distribution System State Estimation
This letter introduces a novel approach for online bad data detection in distribution system state estimation (DSSE) by integrating compressive sensing (CS) with a modified largest normalized residual (LNR)-based detector. To the best of the authors’ knowledge, this is the first work to develop a bad data detection method specifically for CS-based DSSE in unobservable distribution networks. The paper derives a closed-form solution for the compressed sensing problem, which is then used to quantify the error statistics in CS-based DSSE estimates. These statistics enable the design of a modified LNR-based detector using eigen decomposition, significantly improving anomaly detection. Extensive simulations on IEEE 37-bus and 123-bus unbalanced distribution systems demonstrate that the proposed method consistently outperforms the conventional LNR approach and neural network based technique, achieving superior detection rates with low computation effort even with a limited number of measurements. This robust approach effectively detects data anomalies from both random errors and cyber-attacks, making it highly suitable for practical DSSE applications.
- 27 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (4) , 3449-3452
Online Bad Data Detection in Compressed Sensing-Based Distribution System State Estimation
This letter introduces a novel approach for online bad data detection in distribution system state estimation (DSSE) by integrating compressive sensing (CS) with a modified largest normalized residual (LNR)-based detector. To the best of the authors’ knowledge, this is the first work to develop a bad data detection method specifically for CS-based DSSE in unobservable distribution networks. The paper derives a closed-form solution for the compressed sensing problem, which is then used to quantify the error statistics in CS-based DSSE estimates. These statistics enable the design of a modified LNR-based detector using eigen decomposition, significantly improving anomaly detection. Extensive simulations on IEEE 37-bus and 123-bus unbalanced distribution systems demonstrate that the proposed method consistently outperforms the conventional LNR approach and neural network based technique, achieving superior detection rates with low computation effort even with a limited number of measurements. This robust approach effectively detects data anomalies from both random errors and cyber-attacks, making it highly suitable for practical DSSE applications.
- Open Access
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Online Bad Data Detection in Compressed Sensing based Distribution System State Estimation
This letter introduces a novel approach for online bad data detection in distribution system state estimation (DSSE) by integrating compressive sensing (CS) with a modified largest normalized residual (LNR)-based detector. To the best of the authors' knowledge, this is the first work to develop a bad data detection method specifically for CS-based DSSE in unobservable distribution networks. The paper derives a closed-form solution for the compressed sensing problem, which is then used to quantify the error statistics in CS-based DSSE estimates. These statistics enable the design of a modified LNR-based detector using eigen decomposition, significantly improving anomaly detection. Extensive simulations on IEEE 37-bus and 123-bus unbalanced distribution systems demonstrate that the proposed method consistently outperforms the conventional LNR approach, achieving superior detection rates even with a limited number of measurements. This robust approach effectively detects data anomalies from both random errors and cyber-attacks, making it highly suitable for practical DSSE applications.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessOnline Bad Data Detection in Compressed Sensing based Distribution System State Estimation
This letter introduces a novel approach for online bad data detection in distribution system state estimation (DSSE) by integrating compressive sensing (CS) with a modified largest normalized residual (LNR)-based detector. To the best of the authors' knowledge, this is the first work to develop a bad data detection method specifically for CS-based DSSE in unobservable distribution networks. The paper derives a closed-form solution for the compressed sensing problem, which is then used to quantify the error statistics in CS-based DSSE estimates. These statistics enable the design of a modified LNR-based detector using eigen decomposition, significantly improving anomaly detection. Extensive simulations on IEEE 37-bus and 123-bus unbalanced distribution systems demonstrate that the proposed method consistently outperforms the conventional LNR approach, achieving superior detection rates even with a limited number of measurements. This robust approach effectively detects data anomalies from both random errors and cyber-attacks, making it highly suitable for practical DSSE applications.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (6) , 4851-4862
Modified Matrix Completion-Based Detection of Stealthy Data Manipulation Attacks in Low Observable Distribution Systems
A composite detection technique against stealthy data manipulations is developed in this paper for distribution networks that are low observable. Attack detection strategies typically rely on state estimation which becomes challenging when limited measurements are available. In this paper, a modified matrix completion approach provides estimates of the system state and its error variances for the locations in the network where measurements are unavailable. Using the error statistics and their corresponding state estimates, bad data detection can be carried out using the chi-squared test. The proposed approach employs a moving target defence strategy (MTD) where the network parameters are perturbed through distributed flexible AC transmission system (D-FACTS) devices such that stealthy data manipulation attacks can be exposed in the form of bad data. Thus, the bad data detection approach developed in this paper can detect stealthy attacks using the MTD strategy. This technique is implemented on 37-bus and 123-bus three-phase unbalanced distribution networks to demonstrate the attack detection accuracy even for a low observable system.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (6) , 4851-4862
Modified Matrix Completion-Based Detection of Stealthy Data Manipulation Attacks in Low Observable Distribution Systems
A composite detection technique against stealthy data manipulations is developed in this paper for distribution networks that are low observable. Attack detection strategies typically rely on state estimation which becomes challenging when limited measurements are available. In this paper, a modified matrix completion approach provides estimates of the system state and its error variances for the locations in the network where measurements are unavailable. Using the error statistics and their corresponding state estimates, bad data detection can be carried out using the chi-squared test. The proposed approach employs a moving target defence strategy (MTD) where the network parameters are perturbed through distributed flexible AC transmission system (D-FACTS) devices such that stealthy data manipulation attacks can be exposed in the form of bad data. Thus, the bad data detection approach developed in this paper can detect stealthy attacks using the MTD strategy. This technique is implemented on 37-bus and 123-bus three-phase unbalanced distribution networks to demonstrate the attack detection accuracy even for a low observable system.
- 7 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3145-3148
Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System
In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. The proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.
- 7 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3145-3148
Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System
In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. The proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.
- 12 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (1) , 667-677
Electromagnetic Transients-Based Detection of Data Manipulation Attacks in Three Phase Radial Distribution Networks
This paper presents a detection technique for data manipulation attacks in distribution systems using transient information present in the measurements. This technique is based on the fact that any legitimate changes in the system will have a transient response which can be measured by the monitoring system. An algorithm is developed for obtaining the transient solution for three-phase distribution networks. A backward-forward sweep technique is developed for the proposed Radial EMTP (electromagnetic transient program) which exploits the radial structure of distribution network. An inclusive transient model compatible with the proposed three-phase radial EMTP for three-phase synchronous generators is also developed. The proposed Radial EMTP has been benchmarked with conventional EMTP with 5-bus and 22-bus radial distribution systems and with the same test systems, the proposed detection functionality is evaluated. It is shown that the transient solution provided by Radial EMTP are in agreement with the results of conventional EMTP. It is also demonstrated that the deviations between the measured values and the solution of the Radial EMTP increases significantly during the transient period when a data manipulation attack is carried out.
- 12 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (1) , 667-677
Electromagnetic Transients-Based Detection of Data Manipulation Attacks in Three Phase Radial Distribution Networks
This paper presents a detection technique for data manipulation attacks in distribution systems using transient information present in the measurements. This technique is based on the fact that any legitimate changes in the system will have a transient response which can be measured by the monitoring system. An algorithm is developed for obtaining the transient solution for three-phase distribution networks. A backward-forward sweep technique is developed for the proposed Radial EMTP (electromagnetic transient program) which exploits the radial structure of distribution network. An inclusive transient model compatible with the proposed three-phase radial EMTP for three-phase synchronous generators is also developed. The proposed Radial EMTP has been benchmarked with conventional EMTP with 5-bus and 22-bus radial distribution systems and with the same test systems, the proposed detection functionality is evaluated. It is shown that the transient solution provided by Radial EMTP are in agreement with the results of conventional EMTP. It is also demonstrated that the deviations between the measured values and the solution of the Radial EMTP increases significantly during the transient period when a data manipulation attack is carried out.
- 21 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (5) , 4484-4493
Detection of Stealthy Cyber-Physical Line Disconnection Attacks in Smart Grid
This paper considers stealthy cyber-physical attacks in power systems where one or more lines and buses are disconnected by opening their respective switches/circuit breakers and to conceal such attacks, the SCADA and PMU measurements are manipulated stealthily. The paper presents a framework based on the non-linear power flow model to characterize such cyber-physical attacks and proposes a technique that uses switching transients for detecting them. The detection methodology uses the fact that any physical disconnection will cause a notable amount of transients in the system. These transient components measured by the PMUs are used to validate the legitimacy of the steady-state values of SCADA and PMU measurements and detect stealthy line disconnection and bus outage attacks. The proposed technique has been tested on the IEEE 30 bus system and it is shown that it can detect the cyber-physical attacks that conceal multiple line disconnections and bus outages under various load conditions.
- 21 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 12 (5) , 4484-4493
Detection of Stealthy Cyber-Physical Line Disconnection Attacks in Smart Grid
This paper considers stealthy cyber-physical attacks in power systems where one or more lines and buses are disconnected by opening their respective switches/circuit breakers and to conceal such attacks, the SCADA and PMU measurements are manipulated stealthily. The paper presents a framework based on the non-linear power flow model to characterize such cyber-physical attacks and proposes a technique that uses switching transients for detecting them. The detection methodology uses the fact that any physical disconnection will cause a notable amount of transients in the system. These transient components measured by the PMUs are used to validate the legitimacy of the steady-state values of SCADA and PMU measurements and detect stealthy line disconnection and bus outage attacks. The proposed technique has been tested on the IEEE 30 bus system and it is shown that it can detect the cyber-physical attacks that conceal multiple line disconnections and bus outages under various load conditions.