Frank Sterke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Frank Sterke has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Willem van Weteringen
Division of Neonatology, Department of Neonatal and Paediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, University Medical Center Rotterdam, Rotterdam, The Netherlands
5 shared publications - Alberto Arezzo
Department of Surgical Sciences, Università degli Studi di Torino, Torino, Italy
2 shared publications Chen Sagiv
2 shared publications- Daniel Robertson
Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands
2 shared publications Fanny Ficuciello
2 shared publications- Felix Nickel
Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications
Latest Publications
- Open Access
- 24 October 2024
- Published by Springer Nature in Surgical Endoscopy
- Vol. 38 (12) , 7426-7434
Surgical conditions in experimental laparoscopy: effects of pressure, neuromuscular blockade, and pre-stretching on workspace volume
Background: Establishing a pneumoperitoneum for laparoscopy is common surgical practice, with the goal to create an optimal surgical workspace within the abdominal cavity while minimizing insufflation pressure. Individualized strategies, based on neuromuscular blockade (NMB), pre-stretching routines, and personalized intra-abdominal pressure (IAP) to enhance surgical conditions are strategies to improve surgical workspace. However, the specific impact of each factor remains uncertain. This study explores the effects and side-effects of modifying intra-abdominal volume (IAV) through moderate and complete NMB in a porcine laparoscopy model. Methods: Thirty female Landrace pigs were randomly assigned to groups with complete NMB, regular NMB and a control group. Varying IAP levels were applied, and IAV was measured using CT scans. The study evaluated the maximum attainable IAV (Vmax), the pressure at which the cavity opens (p0), and the ease of expansion (λexp). Cardiorespiratory parameters, including peak inspiratory pressure (PIP), mean arterial pressure (MAP), heart rate (HR), and cardiac output (CO), were continuously recorded to evaluate side-effects. Results: There were no significant weight differences between NMB groups (median 21.1 kg). Observed volumes ranged from 0 to 4.7 L, with a mean Vmax of 3.82 L, mean p0 of 1.23 mmHg, and mean λexp of 0.13 hPa−1. NMB depth did not significantly affect these parameters. HR was significantly increased in the complete NMB group, while PIP, MAP, and CO remained unaffected. Repeated insufflation positively impacted Vmax; ease of opening; and expanding the cavity. Conclusion: In this porcine model, the depth of NMB does not alter abdominal mechanics or increase the surgical workspace. Cardiorespiratory changes are more related to insufflation pressure and frequency rather than NMB depth. Future studies should compensate for the positive effect of repeated insufflation on abdominal mechanics and surgical conditions.
- 24 October 2024
- Published by Springer Nature in Surgical Endoscopy
- Vol. 38 (12) , 7426-7434
Open AccessSurgical conditions in experimental laparoscopy: effects of pressure, neuromuscular blockade, and pre-stretching on workspace volume
Background: Establishing a pneumoperitoneum for laparoscopy is common surgical practice, with the goal to create an optimal surgical workspace within the abdominal cavity while minimizing insufflation pressure. Individualized strategies, based on neuromuscular blockade (NMB), pre-stretching routines, and personalized intra-abdominal pressure (IAP) to enhance surgical conditions are strategies to improve surgical workspace. However, the specific impact of each factor remains uncertain. This study explores the effects and side-effects of modifying intra-abdominal volume (IAV) through moderate and complete NMB in a porcine laparoscopy model. Methods: Thirty female Landrace pigs were randomly assigned to groups with complete NMB, regular NMB and a control group. Varying IAP levels were applied, and IAV was measured using CT scans. The study evaluated the maximum attainable IAV (Vmax), the pressure at which the cavity opens (p0), and the ease of expansion (λexp). Cardiorespiratory parameters, including peak inspiratory pressure (PIP), mean arterial pressure (MAP), heart rate (HR), and cardiac output (CO), were continuously recorded to evaluate side-effects. Results: There were no significant weight differences between NMB groups (median 21.1 kg). Observed volumes ranged from 0 to 4.7 L, with a mean Vmax of 3.82 L, mean p0 of 1.23 mmHg, and mean λexp of 0.13 hPa−1. NMB depth did not significantly affect these parameters. HR was significantly increased in the complete NMB group, while PIP, MAP, and CO remained unaffected. Repeated insufflation positively impacted Vmax; ease of opening; and expanding the cavity. Conclusion: In this porcine model, the depth of NMB does not alter abdominal mechanics or increase the surgical workspace. Cardiorespiratory changes are more related to insufflation pressure and frequency rather than NMB depth. Future studies should compensate for the positive effect of repeated insufflation on abdominal mechanics and surgical conditions.
- Open Access
- 5 May 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (5) , e0285108
Automated control for investigation of the insufflation-ventilation interaction in experimental laparoscopy
In laparoscopic surgery the abdominal cavity is insufflated with pressurized carbon dioxide gas to create workspace. This pressure is exerted through the diaphragm onto the lungs, competing with ventilation and hampering it. In clinical practice the difficulty of optimizing this balance can lead to the application of harmfully high pressures. This study set out to create a research platform for the investigation of the complex interaction between insufflation and ventilation in an animal model. The research platform was constructed to incorporate insufflation, ventilation and relevant hemodynamic monitoring devices, controlling insufflation and ventilation from a central computer. The core of the applied methodology is the fixation of physiological parameters by applying closed-loop control of specific ventilation parameters. For accurate volumetric measurements the research platform can be used in a CT scanner. An algorithm was designed to keep blood carbon dioxide and oxygen values stable, minimizing the effect of fluctuations on vascular tone and hemodynamics. This design allowed stepwise adjustment of insufflation pressure to measure the effects on ventilation and circulation. A pilot experiment in a porcine model demonstrated adequate platform performance. The developed research platform and protocol automation have the potential to increase translatability and repeatability of animal experiments on the biomechanical interactions between insufflation and ventilation.
- 5 May 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (5) , e0285108
Open AccessAutomated control for investigation of the insufflation-ventilation interaction in experimental laparoscopy
In laparoscopic surgery the abdominal cavity is insufflated with pressurized carbon dioxide gas to create workspace. This pressure is exerted through the diaphragm onto the lungs, competing with ventilation and hampering it. In clinical practice the difficulty of optimizing this balance can lead to the application of harmfully high pressures. This study set out to create a research platform for the investigation of the complex interaction between insufflation and ventilation in an animal model. The research platform was constructed to incorporate insufflation, ventilation and relevant hemodynamic monitoring devices, controlling insufflation and ventilation from a central computer. The core of the applied methodology is the fixation of physiological parameters by applying closed-loop control of specific ventilation parameters. For accurate volumetric measurements the research platform can be used in a CT scanner. An algorithm was designed to keep blood carbon dioxide and oxygen values stable, minimizing the effect of fluctuations on vascular tone and hemodynamics. This design allowed stepwise adjustment of insufflation pressure to measure the effects on ventilation and circulation. A pilot experiment in a porcine model demonstrated adequate platform performance. The developed research platform and protocol automation have the potential to increase translatability and repeatability of animal experiments on the biomechanical interactions between insufflation and ventilation.
- Open Access
- 21 July 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (9) , 7066-7074
A novel method for monitoring abdominal compliance to optimize insufflation pressure during laparoscopy
Background: Abdominal compliance describes the ease of expansion of the abdominal cavity. Several studies highlighted the importance of monitoring abdominal compliance (Cab) during the creation of laparoscopic workspace to individualize the insufflation pressure. The lack of validated clinical monitoring tools for abdominal compliance prevents accurate tailoring of insufflation pressure. Oscillometry, also known as the forced oscillation technique (FOT), is currently used to measure respiratory mechanics and has the potential to be adapted for monitoring abdominal compliance. This study aimed to define, develop and evaluate a novel approach which can monitor abdominal compliance during laparoscopy using endoscopic oscillometry. Materials and methods: Endoscopic oscillometry was evaluated in a porcine model for laparoscopy. A custom-built insufflator was developed for applying an oscillatory pressure signal superimposed onto a mean intra-abdominal pressure. This insufflator was used to measure the abdominal compliance at insufflation pressures ranging from 5 to 20 hPa (3.75 to 15 mmHg). The measurements were compared to the static abdominal compliance, which was measured simultaneously with computed tomography imaging. Results: Endoscopic oscillometry recordings and CT images were obtained in 10 subjects, resulting in 76 measurement pairs for analysis. The measured dynamic Cab ranged between 0.0216 and 0.261 L/hPa while the static Cab based on the CT imaging ranged between 0.0318 and 0.364 L/hPa. The correlation showed a polynomial relation and the adjusted R-squared was 97.1%. Conclusions: Endoscopic oscillometry can be used to monitor changes in abdominal compliance during laparoscopic surgery, which was demonstrated in this study with a comparison with CT imaging in a porcine laparoscopy model. Use of this technology to personalize the insufflation pressure could reduce the risk of applying excessive pressure and limit the drawbacks of insufflation.
- 21 July 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (9) , 7066-7074
Open AccessA novel method for monitoring abdominal compliance to optimize insufflation pressure during laparoscopy
Background: Abdominal compliance describes the ease of expansion of the abdominal cavity. Several studies highlighted the importance of monitoring abdominal compliance (Cab) during the creation of laparoscopic workspace to individualize the insufflation pressure. The lack of validated clinical monitoring tools for abdominal compliance prevents accurate tailoring of insufflation pressure. Oscillometry, also known as the forced oscillation technique (FOT), is currently used to measure respiratory mechanics and has the potential to be adapted for monitoring abdominal compliance. This study aimed to define, develop and evaluate a novel approach which can monitor abdominal compliance during laparoscopy using endoscopic oscillometry. Materials and methods: Endoscopic oscillometry was evaluated in a porcine model for laparoscopy. A custom-built insufflator was developed for applying an oscillatory pressure signal superimposed onto a mean intra-abdominal pressure. This insufflator was used to measure the abdominal compliance at insufflation pressures ranging from 5 to 20 hPa (3.75 to 15 mmHg). The measurements were compared to the static abdominal compliance, which was measured simultaneously with computed tomography imaging. Results: Endoscopic oscillometry recordings and CT images were obtained in 10 subjects, resulting in 76 measurement pairs for analysis. The measured dynamic Cab ranged between 0.0216 and 0.261 L/hPa while the static Cab based on the CT imaging ranged between 0.0318 and 0.364 L/hPa. The correlation showed a polynomial relation and the adjusted R-squared was 97.1%. Conclusions: Endoscopic oscillometry can be used to monitor changes in abdominal compliance during laparoscopic surgery, which was demonstrated in this study with a comparison with CT imaging in a porcine laparoscopy model. Use of this technology to personalize the insufflation pressure could reduce the risk of applying excessive pressure and limit the drawbacks of insufflation.
- Open Access
- 23 November 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4552
Correction to: Characterisation of trocar associated gas leaks during laparoscopic surgery
- 23 November 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4552
Open AccessCorrection to: Characterisation of trocar associated gas leaks during laparoscopic surgery
- Open Access
- 3 November 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4542-4551
Characterisation of trocar associated gas leaks during laparoscopic surgery
Background: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. Methods: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. Results: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. Conclusions: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.
- 3 November 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4542-4551
Open AccessCharacterisation of trocar associated gas leaks during laparoscopic surgery
Background: During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past trocar valves. No detailed studies currently exist that have quantified these leakage pathways. Therefore, the goal of this study was to quantify the gas leakages through trocars and instruments, during minimally invasive procedures. Methods: A model of the surgical environment was created, consisting of a rigid container with an interface for airtight clamping of laparoscopic equipment such as trocars and surgical instruments. The model was insufflated to 15 mm Hg using a pressure generator and a pneumotachograph measured the equipment gas leak. A protocol of several use cases was designed to simulate the motions and forces the surgeon exerts on the trocar during surgery. Results: Twenty-three individual trocars and twenty-six laparoscopic instruments were measured for leakage under the different conditions of the protocol. Trocar leakages varied between 0 L/min and more than 30 L/min, the instruments revealed a range of leakages between 0 L/min and 5.5 L/min. The results showed that leakage performance varied widely between trocars and instruments and that the performance and location of the valves influenced trocar leakage. Conclusions: We propose trocar redesigns to overcome specific causes of gas leaks. Moreover, an international testing standard for CO2 leakage for all new trocars and instruments is needed so surgical teams can avoid this potential health hazard when selecting new equipment.