RCRafael del Castillo

Rafael del Castillo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rafael del Castillo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical and esthetic outcomes of screw‐retained internal‐connection veneered zirconia‐ceramic CAD‐CAM abutments in single implant reconstructions: Five‐year results of a prospective case series investigation

    by Rafael del Castillo, Lourdes Gutiérrez‐Garrido, Miguel Padial‐Molina, Carlo Ercoli, Pablo Galindo‐Moreno

    Purpose: To evaluate the long‐term clinical performance and survival, as well as the biological, esthetic, and technical complications of one‐piece, internally‐connected, screw‐retained, computer aided‐design and computer aided‐manufacturing (CAD‐CAM) veneered zirconia anterior and posterior implant‐supported single restorations fabricated on regular diameter implants. Materials and Methods: Following a 2‐stage surgical procedure, 22 implants placed in anterior and posterior areas in 21 partially edentulous patients (mean age of 55 years; 9 males/12 females) were evaluated in terms of plaque index, pocket probing depth, bleeding on probing, level of oral hygiene, signs of mucositis/peri‐implantitis, esthetic score, gingival zenith position, Papilla Index Score, thickness of peri‐implant gingiva, radiographic marginal bone loss, and technical complications. Implants and restorations were prospectively followed from the insertion of the restoration (baseline), and up to 5 years postloading. Results: After 5 years, radiological bone stability with no marginal bone loss (0.4 [0.4] vs. 0.5 [1.1] mm from 1‐ to 5‐year follow‐up) was recorded, with a 100% implant survival rate. Clinically, patients performed adequate oral hygiene, and tissues were kept healthy as determined by plaque index (PI) and oral hygiene index (OHI). The esthetic performance of the restorations revealed an increase in mucosal thickness from 3.2 (0.9) mm after 1 year to 3.3 (1.1) mm after 5 years, and a reduction in the gingival zenith position from 7.9 (1.5) mm after 1 year to 7.7 (1.5) mm at the 5‐year recall examination. The prosthetic survival rate after 5 years was 78.9%, as 4 abutments fractured at different time points during the study. All abutment fractures occurred in the mandible, at the level of the second premolars and first molars. Conclusions: After 5 years clinical function, Atlantis one‐piece, screw‐retained, internally connected CAD‐CAM veneered zirconia implant‐supported single crowns resulted in a relatively low survival rate, mainly associated with posterior single implant‐supported reconstructions. However, due to the fact that the present clinical investigation used only one abutment design and reconstruction type, extrapolation of data to different implant systems, abutment designs, and reconstruction types must be cautious.

  • Screw‐retained internal connection zirconia CAD–CAM abutments in single implant reconstructions: Results of a 1‐year prospective case series study

    by Rafael del Castillo, Lourdes Gutiérrez‐Garrido, Miguel Padial‐Molina, Pablo Galindo‐Moreno

    Purpose: To evaluate the clinical and radiographic outcomes of single‐tooth implant restorations using one‐piece, internally connected, screw‐retained, computer‐aided design and computer‐aided manufactured monolithic zirconia restorations fabricated on regular diameter implants.Material and methods: Following a 2‐stage surgical procedure, 22 implants placed in anterior and posterior areas in 21 partially edentulous patients (mean age of 55 years; 9 males/12 females) were evaluated in terms of plaque index, pocket probing depth, bleeding on probing, level of oral hygiene (OH), signs of mucositis/peri‐implantitis, esthetic score (ES), gingival zenith position (GZP), papilla index score, the thickness of peri‐implant gingiva, radiographic marginal bone loss, and technical complications. Implants and restorations were prospectively followed from the insertion of the restoration (baseline), up to 12‐months post‐loading.Results: A 100% implant survival rate resulted after loading; one implant was lost before loading. Clinically, patients performed an adequate OH, and tissues were kept healthy. Probing depth showed a slightly lower value at baseline compared to any follow‐up examination (2.26 [0.94] at baseline vs. 2.53 [0.66] mm at 12 months). ES, GZP, and the thickness of the peri‐implant gingiva improved throughout the course of the study. Radiographically, average marginal bone level (MBL) was 0.40 (0.40) mm after 1‐year follow‐up with no differences in average MBL at all time points. Technically, after 1 year of clinical function, neither abutment fracture nor any other serious complications occurred. Hence, prosthetic reconstruction survival rate was 100%.Conclusions: Clinical outcomes of single‐tooth implant restorations using internally connected, screw‐retained, computer‐aided design and computer‐aided manufacturing monolithic zirconia abutments can be considered a reliable treatment alternative after 1‐year clinical observation.


  • The clinical use of computer aided designed/computer aided manufactured titanium nitride coated implant abutments: Surgical and prosthetic considerations—A case series

    by Rafael del Castillo, Javier Ata‐Ali

    ObjectiveTo describe the clinical use of nitride-coated titanium CAD/CAM implant abutments in the maxillary esthetic zone in two patients with high esthetic and functional demands and, to highlight the advantages of nitride-coated milled titanium abutments when compared to stock/custom titanium, one-piece monolithic zirconia, and hybrid metal-zirconia implant abutments. Clinical ConsiderationsDue to the inherent mechanical and esthetic clinical challenges, single implant-supported reconstructions in the maxillary esthetic zone are a complex restorative treatment. While CAD/CAM technology has been suggested to enhance and ease implant abutment design and manufacturing, implant abutment material selection remains as a critical decision affecting restoration's long-term clinical outcomes. To date, considering the esthetic disadvantages of conventional titanium implant abutments, the mechanical limitations of one-piece zirconia abutments and the manufacturing time and costs associated with hybrid metal-zirconia abutments, no abutment material can be considered "ideal" for all clinical scenarios.Due to their biocompatibility, biomechanical characteristics (hardness and wear resistance), optical properties (yellow color), and peri-implant soft tissue esthetic integration, the use of CAD/CAM titanium nitride-coated implant abutments has been suggested as a predictable implant abutment material in mechanically challenging but esthetically demanding clinical situations, as the maxillary esthetic zone. ConclusionsTwo patients requiring a combined tooth-implant restorative treatment in the maxillary esthetic zone were treated using CAD/CAM nitride coated titanium implant abutments. The principal advantages of TiN coated abutments include comparable clinical outcomes to stock abutments, optimal biocompatibility, adequate fracture, wear, and corrosion resistance, reduced bacterial adhesion, and excellent esthetic integration with adjacent soft tissues. Clinical SignificanceClinical reports and short term mechanical, biological and esthetic clinical outcomes indicate that CAD/CAM nitride coated titanium implant abutments can represent a predictable restorative alternative to stock/custom and metal/zirconia implant abutments and be considered a clinical relevant option in mechanically challenging but esthetically demanding situations, as often found in the maxillary esthetic zone.


  • Titanium Nitride Coated Implant Abutments: From Technical Aspects And Soft tissue Biocompatibility to Clinical Applications. A Literature Review

    by Rafael del Castillo, Konstantinos Chochlidakis, Pablo Galindo‐Moreno, Carlo Ercoli

    Purpose: To review the most up to date scientific evidence concerning the technical implications, soft tissue biocompatibility, and clinical applications derived from the use of titanium nitride hard thin film coatings on titanium alloy implant abutments.Materials and Methods: A review was performed to answer the following focused question: “What is the clinical reliability of nitride coated titanium alloy abutments?”. A MEDLINE search between 1980 and 2021 was performed for investigations pertaining to the clinical use of nitride coated titanium alloy implant abutments (TiN) in case reports, case series, and short‐ and long‐term non/randomized controlled clinical trials. Literature analysis led to addition evaluation of research related to the technical and biological aspects, as well as the physicochemical characteristics of TiN hard thin film coatings and their impact on titanium abutment biocompatibility, mechanical properties, macroscopic surface topography, and optical properties. Therefore, preclinical data from biomechanical and in vitro investigations were also considered as inclusion criteria.Results: The limited number of clinical investigations published made a systematic review and meta‐analysis not possible, therefore a narrative review was conducted. TiN coatings have been applied to dental materials and instruments to improve their clinical longevity. Implant abutments are coated with titanium nitride to mask the titanium oxide surface and enhance its surface characteristics providing the TiN abutment surface with a low friction coefficient and a very high chemical inertness. TiN coating is suggested to reduce early bacterial colonization and biofilm formation and enhance fibroblast cell proliferation, attachment and adhesion when compared to Ti controls. Additionally, studies indicate that hard thin film coatings enhance the mechanical properties (hardness and wear resistance) of titanium alloy and appears as a yellow color when deposited on the titanium alloy substrate. To date, clinical investigations show that nitride coated titanium abutments provide promising short‐term clinical outcomes.Conclusions: Published research on nitride‐coated abutments is still limited, however, the available biomedical research, mechanical engineering tests, in vitro investigations, and short‐term clinical trials have, to date, reported promising mechanical, biological, and esthetic outcomes.


  • An alternative multiple pontic design for a fixed implant-supported prosthesis

    by Rafael Del Castillo, Carlo Ercoli, Juan Carlos Delgado, Jaime Alcaraz