LVLogi Vidarsson

Logi Vidarsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Logi Vidarsson has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Genetic and Congenital Cytomegalovirus–Related Hearing Loss in Children: Volumetric MRI Analysis of Auditory and Visual Cortices

    by Shivaprakash B. Hiremath, Matthias Wagner, Sharon L. Cushing, Karen A. Gordon, Ari Bitnun, Afsaneh Amirabadi, Logi Vidarsson, Birgit B. Ertl-Wagner

    Although effects of deafness on the brain have been reported, little is known about the differential impact of genetic versus acquired etiologies. Our purpose was to assess cortical volumetric differences and hemispheric asymmetry in children with gap junction protein beta-2 (GJB2)- and congenital cytomegalovirus (cCMV)-related hearing loss compared with age- and sex-matched controls. In this retrospective study, 3D T1-weighted sequences of children with cCMV-related hearing loss, GJB2-related hearing loss, and normal hearing were analyzed using FreeSurfer volumetric segmentation. Cortical volumes of Heschl gyrus (HG), planum polare (PP), planum temporale (PT), lateral aspect of superior temporal gyrus (LSTG), primary visual cortex, and cuneus were assessed. We performed a linear mixed model analysis to investigate cortical volumetric differences between 1:3 case:control-matched groups, adjusting for age, sex, and field strength. The laterality index was calculated to assess hemispheric asymmetry, and a 2-tailed 1-sample t test was used to compare the distribution of values against zero. Statistical significance was determined at a threshold of P < .05. Twenty-two children with cCMV-related hearing loss, 7 children with GJB2-related hearing loss, and 87 age- and sex-matched children with normal hearing were included. Significant differences were observed between the cortical volumes in the right (P = .03), left (P = .03), and total cuneus (P = .02) between GJB2-related hearing loss and controls; HG (P = .02) and PT (P < .001) on the right; LSTG (P = .002) on the left; and the total HG (P = .02) and PT (P < .001) between cCMV-related hearing loss and controls. HG was significantly larger on the left in GJB2-related SNHL (P = .01), and the HG, PT, and LSTG were significantly larger on the left with a significantly larger right cuneus in both cCMV-related hearing loss and controls (P < .01). GJB2-related hearing loss is associated with volumetric alterations in the visual cortices, and alterations in the auditory cortical regions occur in cCMV-related hearing loss. Particular auditory areas showed significant leftward asymmetry in GJB2- and cCMV-related hearing loss and controls. In contrast, the visual areas showed significant rightward asymmetry in both CMV-related hearing loss and controls.

  • The influence of preformed metal crowns versus zirconia crowns on the diagnostic quality of magnetic resonance images

    by O. Dalzell, P. Haghighi, J. Ho, T. Rayner, L. Vidarsson, G. A. Garisto

    Purpose The purpose of this study was to investigate and compare in vitro the influence of preformed metal crowns (PMC) versus zirconia crowns (ZC) on the extent of artifact formation and the diagnostic quality of magnetic resonance imaging (MRI). Methods Standard crown tooth preparations were performed on Typodont models. PMC and ZC were cemented on all primary molar teeth (n = 8) of the respective models. MRI scans were taken for the Typodont alone (control), PMC, and ZC, using a 3 T MRI machine and common MRI sequences. The diameter of image distortion was measured around the dental materials. Data was analyzed using a mixed model analysis. Results The average artifact size for PMC was 54.9 mm (range 19.6–110.7 mm) and 12.8 mm (range 5.5–20.7 mm) for ZC. The artifact size was associated with the MRI pulse sequence and dental material, with PMC showing larger artifact diameters than ZC for all MRI sequences (p < 0.001). The control had sensitive sequences for AxT2* and DWI sequences with MRI artifacts of 11.4 mm and 10.7 mm, respectively. Conclusions It is important that dentists are aware of the potential of dental materials to cause unfavourable MRI artifacts. When areas of the brain requiring MRI preclude the use of PMC, ZC may be considered as an alternative to extractions. Further clinical studies are required to evaluate the impact of dental materials on the image quality of MR scans in vivo.


  • Brain Maturation Patterns on Normalized FLAIR MR Imaging in Children and Adolescents

    by K. Chan, A. Ghazvanchahi, D. Rabba, L. Vidarsson, M.W. Wagner, B.B. Ertl-Wagner, A. Khademi

    BACKGROUND AND PURPOSE: Signal analysis of FLAIR sequences is gaining momentum for studying neurodevelopment and brain maturation, but FLAIR intensity varies across scanners and needs to be normalized. This study aimed to establish normative values for standardized FLAIR intensity in the pediatric brain. MATERIALS AND METHODS: A new automated algorithm for signal normalization was used to standardize FLAIR intensity across scanners and subjects. Mean intensity was extracted from GM, WM, deep GM, and cortical GM regions. Regression curves were fitted across the pediatric age range, and ANOVA was used to investigate intensity differences across age groups. Correlations between intensity and regional volume were also examined. RESULTS: We analyzed 429 pediatric FLAIR sequences in children 2–19 years of age with a median age of 11.2 years, including 199 males and 230 females. WM intensity had a parabolic relationship with age, with significant differences between various age groups (P < .05). GM and cortical GM intensity increased over the pediatric age range, with significant differences between early childhood and adolescence (P < .05). There were no significant relationships between volume and intensity in early childhood, while there were significant positive and negative correlations (P < .05) in WM and GM, respectively, for increasing age groups. Only the oldest age group showed significant differences between males and females (P < .05). CONCLUSIONS: This work presents a FLAIR intensity standardization algorithm to normalize intensity across large data sets, which allows FLAIR intensity to be used to compare regions and individuals as a surrogate measure of the developing pediatric brain.


  • Open Access

    Increased rate of significant findings on brain MRI during the early stage of the COVID-19 pandemic

    by Matthias W Wagner, Dalia Jadkarim, Nikil K Rajani, Asthik Biswas, Richard Olatunji, Wyanne Law, Logi Vidarsson, Afsaneh Amirabadi, Birgit B Ertl-Wagner

    Objectives: To assess the effect of the COVID-19 pandemic on the proportion of abnormal paediatric neuroimaging findings as a surrogate marker for potential underutilisation. Methods: Consecutive paediatric brain MRIs performed between March 27th and June 19th 2019 (Tbaseline) and March 23rd and June 1st 2020 (Tpandemic) were reviewed and classified according to presence or absence and type of imaging abnormality, and graded regarding severity on a 5-point Likert scale, where grade 4 was defined as abnormal finding requiring non-urgent intervention and grade 5 was defined as acute illness prompting urgent medical intervention. Non-parametric statistical testing was used to assess for significant differences between Tpandemic vs. Tbaseline. Results: Fewer paediatric MRI brains were performed during Tpandemic compared to Tbaseline (12.2 vs 14.7 examinations/day). No significant difference was found between the two time periods regarding sex and age (Tbaseline: 557 females (44.63%), 7.95 ± 5.49 years, Tpandemic: 385 females (44.61%), 7.64 ± 6.11 years; p = 1 and p = .079, respectively). MRI brain examinations during Tpandemic had a higher likelihood of being abnormal, 41.25% vs. 25.32% ( p<.0001). Vascular abnormalities were more frequent during Tpandemic (11.01% vs 8.01%, p = .02), congenital malformations were less common (8.34% vs 12.34%, p = .004). Severity of MRI brain examinations was significantly different when comparing group 4 and group 5 individually and combined between Tbaseline and Tpandemic ( p = .0018, p < .0001, and p <.0001, respectively). Conclusions: The rate of abnormality and severity found on paediatric brain MRI was significantly higher during the early phase of the pandemic, likely due to underutilisation.


  • Open Access

    Volumetric differences of thalamic nuclei in children with trisomy 21

    by Matthias W Wagner, Nirit Bernhard, Gopolang Mndebele, Logi Vidarsson, Birgit B Ertl-Wagner

    Objectives: Histological studies have shown alterations of thalamic nuclei in patients with Down syndrome (DS). The correlation of these changes on MRI (magnetic resonance imaging) is unclear. Therefore, this study investigates volumetric differences of thalamic nuclei in children with DS compared to controls. Methods: Patients were retrospectively identified between 01/2000 and 10/2021. Patient inclusion criteria were: (1) 0–18 years of age, (2) diagnosis of DS, and (3) availability of a brain MRI without parenchymal injury and a non-motion-degraded volumetric T1-weighted sequence. Whole thalamus and thalamic nuclei ( n = 25) volumes were analyzed bilaterally relative to the total brain volume (TBV). Two-sided t-tests were used to evaluate differences between groups. Differences were considered significant if the adjusted p-value was <0.05 after correction for multiple hypothesis testing using the Holm-Bonferroni method. Results: 21 children with DS (11 females, 52.4%, mean age: 8.6 ± 4.3 years) and 63 age- and sex-matched controls (32 females, 50.8%, 8.6 ± 4.3 years) were studied using automated volumetric segmentation. Significantly smaller ratios were found for nine thalamic nuclei and the whole thalamus on the right and five thalamic nuclei on the left. TBV was significantly smaller in patients with DS ( p < 0.001). No significant differences were found between the groups for age and sex. Conclusions: In this exploratory volumetric analysis of the thalamus and thalamic nuclei, we observed statistically significant volumetric changes in children with DS. Our findings confirm prior neuroimaging and histological studies and extend the range of involved thalamic nuclei in pediatric DS.


  • Rotational Vertebrobasilar Insufficiency: Is There a Physiological Spectrum? Phase-Contrast Magnetic Resonance Imaging Quantification in Healthy Volunteers

    by Adam A. Dmytriw, Suzanne Bickford, Parneyan Pezeshkpour, Winston Ha, Afsaneh Amirabadi, Mahmoud Dibas, Lee Ann Kitamura, Logi Vidarsson, Elizabeth Pulcine, Prakash Muthusami


  • Open Access

    A Short and Light, Sparse Dipolar Halbach Magnet for MRI

    by Aaron R. Purchase, Logi Vidarsson, Keith Wachowicz, Piotr Liszkowski, Hongwei Sun, Gordon E. Sarty, Jonathan C. Sharp, Boguslaw Tomanek

    Recently designed dipolar Halbach magnets used in portable MRI systems are much lighter and more compact than standard permanent or superconductive magnets. However, improved designs and manufacturing techniques aiming at lower weight and smaller external size are an area of continual interest especially for application to space flight. Most Halbach magnet design techniques aim to optimize homogeneity suitable for MRI over a diameter-spherical volume (DSV) that requires the aspect ratio (length/inner diameter) to be larger than 1.5:1. Furthermore, current magnet construction techniques often use low-coercivity magnetic pieces and imperfect formers that produce a mismatch in the intended designs. As a result, Halbach magnets require complex shimming methods to improve the magnetic field homogeneity, causing further size and weight increase. Here, we propose to reduce the weight and the aspect ratio of the Halbach magnet by optimizing homogeneity over a cylindrical region of interest (ROI) rather than a DSV, applying a genetic algorithm, high-coercivity ferromagnets (N40UH) and a robust construction technique. The assembled 67 mT magnet, with aspect ratio ~ 1:1, produces almost identical homogeneity (11152 ppm) as simulations (11451 ppm) within a 12.7 cm diameter, 1 cm long cylinder ROI. The magnet structure was 3D printed ring-by-ring and assembled coaxially. The magnet can be disassembled for transportation.