GLGa-Eun Lee

Ga-Eun Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ga-Eun Lee has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CMOS Detector Staggered Array Module for Sub-Terahertz Imaging on Conveyor Belt System

    by Moon-Jeong Lee, Ha-Neul Lee, Ga-Eun Lee, Seong-Tae Han, Dong-Woo Kang, Jong-Ryul Yang

    A complementary metal–oxide–semiconductor (CMOS) detector array is proposed to improve the sub-terahertz imaging resolution for objects in the conveyor belt system. The image resolution is limited to the implemented configuration, such as the wide spacing in the detector array, the high conveyor belt speed, and the slow response of the signal conditioning block. The proposed array can improve the image resolution in the direction perpendicular to the movement of the belt, which is determined by the size and interval of the detector pixel, by configuring the array into two replaceable columns located at the misaligned horizontal positions. Replaceable detector unit pixels are individually attached to the motherboard after measuring and evaluating the detection performance to construct the proposed array. The intensities of 32 detector pixels placed under the conveyor belt with a width of 160 mm were initially calibrated in every image, including the beam pattern of 0.2 THz signals generated from the gyrotron. The image resolution of the perpendicular direction obtained from the proposed array was measured to be approximately 5 mm at a conveyor belt speed of 16 mm/s, demonstrating a 200% improvement in resolution compared to the conventional linear array under the same conditions.


  • Open Access

    Concurrent-Mode CMOS Detector IC for Sub-Terahertz Imaging System

    by Moon-Jeong Lee, Ha-Neul Lee, Ga-Eun Lee, Seong-Tae Han, Jong-Ryul Yang

    A CMOS detector with a concurrent mode for high-quality images in the sub-terahertz region has been proposed. The detector improves output-signal coupling characteristics at the output node. A cross-coupling capacitor is added to isolate the DC bias between the drain and gate. The detector is designed to combine a 180° phase shift based on common source operation and an in-phase output signal based on the drain input. The circuit layout and phase shift occurring in the cross-coupled capacitor during phase coupling are verified using an EM simulation. The detector is fabricated using the TSMC 0.25-μm mixed-signal 1-poly 5-metal layer CMOS process, where the size, including the pad, is 1.13 mm × 0.74 mm. The detector IC comprises a folded dipole antenna, the proposed detector, a preamplifier, and a voltage buffer. Measurement results using a 200-GHz gyrotron source demonstrate that the proposed detector voltage responsivity is 14.13 MV/W with a noise-equivalent power of 34.42 pW/√Hz. The high detection performance helps resolve the 2-mm line width. The proposed detector exhibits a signal-to-noise ratio of 49 dB with regard to the THz imaging performance, which is 9 dB higher than that of the previous CMOS detector core circuits with gate-drain capacitors.


  • CMOS Detector Using Customized Bolt-Wrench Capacitor on Backend Oxide Layer

    by Ga-Eun Lee, Hyo-Jin Lee, Seong-Tae Han, Jong-Ryul Yang

    A CMOS detector with a customized capacitor is proposed to improve the detection performance for terahertz imaging systems. The proposed gate-drain capacitor is formed based on the bolt-wrench shape integrated into the layout design of the detector core. The proposed capacitor is implemented using a metal-insulator-metal stack in the backend oxide layer of the TSMC 0.25- μm CMOS technology. The detector using the customized capacitor exhibits an 18% improvement in the voltage responsivity simulation compared to the detector using the capacitor in the process design kit (PDK). The measurement results of the detector, including the integrated antenna and amplifiers, indicate a voltage responsivity of 2.99 MV/W and a noise-equivalent power of 46.3 pW/ √Hz. The 200-GHz images obtained using the proposed detector demonstrate a 30% correlation improvement with the sample compared to the images obtained using the detector with the PDK capacitor.


  • Open Access

    Correction: Park, J.-H. et al. 915-MHz Continuous-Wave Doppler Radar Sensor for Detection of Vital Signs. Electronics 2019, 8, 561

    by Jae-Hyun Park, Yeo-Jin Jeong, Ga-Eun Lee, Jun-Taek Oh, Jong-Ryul Yang

    The authors wish to make the following corrections to the published paper


  • Open Access

    915-MHz Continuous-Wave Doppler Radar Sensor for Detection of Vital Signs

    by Jae-Hyun Park, Yeo-Jin Jeong, Ga-Eun Lee, Jun-Taek Oh, Jong-Ryul Yang

    A miniaturized continuous-wave Doppler radar sensor operating at 915 MHz to remotely detect both respiration and heart rate (beats per minute) is presented. The proposed radar sensor comprises a front-end module including an implemented complementary metal-oxide semiconductor low-noise amplifier (LNA) and fractal-slot patch antennas, whose area was reduced by 15.2%. The two-stage inverter-based LNA was designed with an interstage capacitor and a feedback resistor to acquire ultrawide bandwidth. Two operating frequencies, 915 MHz and 2.45 GHz, were analyzed with regard to path loss for efficient operation because frequency affects detection sensitivity, reflected signal power from the human body, and measurement distance in a far-field condition. Path-loss calculation based on the simplified layer model indicates that the reflected power of the 915 MHz radar could be higher than that of the 2.45 GHz radar. The implemented radar front-end module excluding the LNA occupies 35 × 55 mm2. Vital signs were obtained via a fast Fourier transform and digital filtering using raw signals. In an experiment with six subjects, the respiration and heart rate obtained at 0.8 m using the proposed radar sensor exhibited mean accuracies of 99.4% and 97.6% with respect to commercialized reference sensors, respectively.