Zekun Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zekun Wu has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Kevin P. Chen
University of Pittsburgh
6 shared publications - Kehao Zhao
Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA
4 shared publications - Qirui Wang
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications - Zhi-Hong Mao
University of Pittsburgh
3 shared publications David Carpenter
Nuclear Reactor Laboratory, Massachusetts Institute of Technology, Cambridge, MA, USA
2 shared publications- Guangqun Ma
Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA
2 shared publications
Latest Publications
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 34 (5) , 594-602
Rapid Prototyping of Tape-Based Microfluidic Chips With Versatile On-Chip Fluidic Functions
This paper presents a rapid prototyping method for fabricating double-sided tape-based microfluidic chips that address limitations in material flexibility, fabrication complexity, and on-chip functionalities. The approach employs biocompatible, low-cost materials—including medical-grade tapes, rubber, and thermoplastics (PMMA, polycarbonate, polystyrene)—micromachined via femtosecond lasers. Solvent- and heat-free tape-based bonding enables efficient fabrication of optically transparent, UV-sterilizable layers for biomedical applications. The method supports integrated on-chip pumps and active/passive valves, achieving bidirectional and multidirectional flow control with minimal external actuation. These components operate at up to 14 psi actuation pressure and $230~\mu $ L/min flow rates, adaptable via chamber dimensions. A dual-pump configuration mimics peristaltic pumping for continuous flow, while a prototype with multidirectional pumps and reservoirs demonstrates dynamic fluid routing and on-demand distribution. The technique offers a versatile, scalable solution for microfluidic applications requiring sterility, optical clarity, and on-chip fluidic control. [2025-0059]
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 34 (5) , 594-602
Rapid Prototyping of Tape-Based Microfluidic Chips With Versatile On-Chip Fluidic Functions
This paper presents a rapid prototyping method for fabricating double-sided tape-based microfluidic chips that address limitations in material flexibility, fabrication complexity, and on-chip functionalities. The approach employs biocompatible, low-cost materials—including medical-grade tapes, rubber, and thermoplastics (PMMA, polycarbonate, polystyrene)—micromachined via femtosecond lasers. Solvent- and heat-free tape-based bonding enables efficient fabrication of optically transparent, UV-sterilizable layers for biomedical applications. The method supports integrated on-chip pumps and active/passive valves, achieving bidirectional and multidirectional flow control with minimal external actuation. These components operate at up to 14 psi actuation pressure and $230~\mu $ L/min flow rates, adaptable via chamber dimensions. A dual-pump configuration mimics peristaltic pumping for continuous flow, while a prototype with multidirectional pumps and reservoirs demonstrates dynamic fluid routing and on-demand distribution. The technique offers a versatile, scalable solution for microfluidic applications requiring sterility, optical clarity, and on-chip fluidic control. [2025-0059]
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 17011-17017
Cost-Effective FBG Demodulation for High-Temperature and Dynamic Strain via Modified Levenberg-Marquardt
This paper presents a high-resolution, signal-jump-free demodulation method for Fiber Bragg Grating (FBG) systems employing a low-cost spectrometer. Utilizing a modified Logarithm Gaussian Levenberg-Marquardt (LGLM) method, the proposed approach enables precise and stable Bragg wavelength tracking. The principles of the LGLM method were thoroughly analyzed and derived, affirming the feasibility and robustness of the FBG system. Static experiments with 9 sampling points demonstrated that the LGLM method achieves a standard deviation (STD) of 1.7 pm, representing a 6.9-fold improvement over conventional Gaussian fitting. Strain experiments confirmed a strong linear relationship between strain and Bragg wavelength, with dynamic strain measurements at a 6 kHz sampling rate showing that the LGLM method effectively eliminates signal jumps observed in Gaussian fitting. At 500 Hz, the minimum detectable strain (MDS) of the LGLM method was determined to be 0.0173 με/Hz−1/2, more than 10 times better than Gaussian fitting. Temperature experiments conducted over a range of 100–700 °C further validated the method's performance, with the LGLM achieving an STD of 1.56 pm and a variation of 3.4 pm, representing improvements of 10.25 times and 52.9 times, respectively, compared to Gaussian fitting. These findings demonstrate the exceptional sensitivity, stability, and robustness of the LGLM method for demanding applications such as high-temperature monitoring and structural health diagnostics.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 17011-17017
Cost-Effective FBG Demodulation for High-Temperature and Dynamic Strain via Modified Levenberg-Marquardt
This paper presents a high-resolution, signal-jump-free demodulation method for Fiber Bragg Grating (FBG) systems employing a low-cost spectrometer. Utilizing a modified Logarithm Gaussian Levenberg-Marquardt (LGLM) method, the proposed approach enables precise and stable Bragg wavelength tracking. The principles of the LGLM method were thoroughly analyzed and derived, affirming the feasibility and robustness of the FBG system. Static experiments with 9 sampling points demonstrated that the LGLM method achieves a standard deviation (STD) of 1.7 pm, representing a 6.9-fold improvement over conventional Gaussian fitting. Strain experiments confirmed a strong linear relationship between strain and Bragg wavelength, with dynamic strain measurements at a 6 kHz sampling rate showing that the LGLM method effectively eliminates signal jumps observed in Gaussian fitting. At 500 Hz, the minimum detectable strain (MDS) of the LGLM method was determined to be 0.0173 με/Hz−1/2, more than 10 times better than Gaussian fitting. Temperature experiments conducted over a range of 100–700 °C further validated the method's performance, with the LGLM achieving an STD of 1.56 pm and a variation of 3.4 pm, representing improvements of 10.25 times and 52.9 times, respectively, compared to Gaussian fitting. These findings demonstrate the exceptional sensitivity, stability, and robustness of the LGLM method for demanding applications such as high-temperature monitoring and structural health diagnostics.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34394-34403
High Spatial Resolution and Accurate Temperature Profile Measurements in a Nuclear Reactor Core Enabled by Machine Learning
This paper reports on laser fabrication, in-pile testing, and artificial intelligence (AI) enabled data analytics of distributed fiber sensors to monitor nuclear power systems (NPS). As intense radiation, high temperature, and hysteresis induce complex and significant sensor drifts, this paper studies long short-term memory (LSTM) neural network and k-nearest neighbor algorithm (k-NN) as data analytics tools to correct sensor drift. Using three thermocouples (TC) as calibration, LSTM neural networks were used to learn radiation effects exerted on fiber sensors located at the same location of TCs during normal states and simulated incidents of a test reactor. Fiber sensor measurements of other locations were rectified using k-NN based on knowledge harnessed by fiber sensors in calibration locations. The integrated sensor fusion and AI-enabled data analytics improved the temperature accuracy of fiber sensors to 2 °C during normal conditions. In a simulated reactor anomaly with a temperature excursion to 520 °C, the fiber sensors’ measurement accuracy was within 18 °C. This paper presents an integrated approach to fully harness the 1-cm-high spatial resolution measurement capabilities of distributed fiber sensors for nuclear energy applications. It can improve the applicability of fiber sensors as part of Instrumentation and Control (I&C) systems for future NPS.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34394-34403
High Spatial Resolution and Accurate Temperature Profile Measurements in a Nuclear Reactor Core Enabled by Machine Learning
This paper reports on laser fabrication, in-pile testing, and artificial intelligence (AI) enabled data analytics of distributed fiber sensors to monitor nuclear power systems (NPS). As intense radiation, high temperature, and hysteresis induce complex and significant sensor drifts, this paper studies long short-term memory (LSTM) neural network and k-nearest neighbor algorithm (k-NN) as data analytics tools to correct sensor drift. Using three thermocouples (TC) as calibration, LSTM neural networks were used to learn radiation effects exerted on fiber sensors located at the same location of TCs during normal states and simulated incidents of a test reactor. Fiber sensor measurements of other locations were rectified using k-NN based on knowledge harnessed by fiber sensors in calibration locations. The integrated sensor fusion and AI-enabled data analytics improved the temperature accuracy of fiber sensors to 2 °C during normal conditions. In a simulated reactor anomaly with a temperature excursion to 520 °C, the fiber sensors’ measurement accuracy was within 18 °C. This paper presents an integrated approach to fully harness the 1-cm-high spatial resolution measurement capabilities of distributed fiber sensors for nuclear energy applications. It can improve the applicability of fiber sensors as part of Instrumentation and Control (I&C) systems for future NPS.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12516, 21-108
Development of a 3D-printed, sensitivity-optimized fluorometer based on ultraviolet LED for VIS fluorescence spectrum analysis
This paper introduces a fluorometer that is both economically viable and optimized for sensitivity. The sensor is designed to detect low concentrations of fluorophores in the visible spectrum range, utilizing a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Unlike traditional general-purpose spectrometers, this sensor achieves a balance between the two through an appropriate aperture size and tailored optical design optimized for the spectral characteristics of fluorophores. The manuscript presents measurements of rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions at ppb-level concentrations. By optimizing the collection of fluorescence emission without sacrificing spectral information, this work demonstrates the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensor that is comparable to bench-top commercial spectrofluorometers at a fraction of the cost.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12516, 21-108
Development of a 3D-printed, sensitivity-optimized fluorometer based on ultraviolet LED for VIS fluorescence spectrum analysis
This paper introduces a fluorometer that is both economically viable and optimized for sensitivity. The sensor is designed to detect low concentrations of fluorophores in the visible spectrum range, utilizing a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Unlike traditional general-purpose spectrometers, this sensor achieves a balance between the two through an appropriate aperture size and tailored optical design optimized for the spectral characteristics of fluorophores. The manuscript presents measurements of rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions at ppb-level concentrations. By optimizing the collection of fluorescence emission without sacrificing spectral information, this work demonstrates the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensor that is comparable to bench-top commercial spectrofluorometers at a fraction of the cost.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11574-11581
Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis
This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. The manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11574-11581
Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis
This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. The manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.
- Open Access
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (6) , 5824-5830
CO2Laser Tapering of Intrinsic Fabry–Perot Interferometers for Sensing
We present a highly reproducible method of fabricating a tapered intrinsic Fabry-Perot interferometer (IFPI) device with 5~6-μm diameter at the taper waist. A femtosecond laser was applied to inscribe an IFPI with 3-cm cavity length in a single-mode fiber. A CO 2 laser heated tapering process enabled by digitally controlled mirrors and a precision motorized fiber feed system was used to create a stable heating zone with the desired temperature profile for tapering the fiber IFPI cavity. The well-engineered tapering process produced tapered IFPI devices with insertion loss less than 0.3-dB at 1550-nm. A strong evanescent field exposed by the taper section was explored for refractive index sensing. Using swept optical frequency domination reflectometry, the tapered IFPI fiber sensor achieved a minimal refractive index sensing resolution 2×10 -5 . This paper demonstrates an integrated laser fabrication technique to produce tapered fiber optic devices for sensing applications.
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (6) , 5824-5830
Open AccessCO2Laser Tapering of Intrinsic Fabry–Perot Interferometers for Sensing
We present a highly reproducible method of fabricating a tapered intrinsic Fabry-Perot interferometer (IFPI) device with 5~6-μm diameter at the taper waist. A femtosecond laser was applied to inscribe an IFPI with 3-cm cavity length in a single-mode fiber. A CO 2 laser heated tapering process enabled by digitally controlled mirrors and a precision motorized fiber feed system was used to create a stable heating zone with the desired temperature profile for tapering the fiber IFPI cavity. The well-engineered tapering process produced tapered IFPI devices with insertion loss less than 0.3-dB at 1550-nm. A strong evanescent field exposed by the taper section was explored for refractive index sensing. Using swept optical frequency domination reflectometry, the tapered IFPI fiber sensor achieved a minimal refractive index sensing resolution 2×10 -5 . This paper demonstrates an integrated laser fabrication technique to produce tapered fiber optic devices for sensing applications.
- Open Access
A Novel Approach to Dining Bowl Reconstruction for Image-Based Food Volume Estimation
Knowing the amounts of energy and nutrients in an individual’s diet is important for maintaining health and preventing chronic diseases. As electronic and AI technologies advance rapidly, dietary assessment can now be performed using food images obtained from a smartphone or a wearable device. One of the challenges in this approach is to computationally measure the volume of food in a bowl from an image. This problem has not been studied systematically despite the bowl being the most utilized food container in many parts of the world, especially in Asia and Africa. In this paper, we present a new method to measure the size and shape of a bowl by adhering a paper ruler centrally across the bottom and sides of the bowl and then taking an image. When observed from the image, the distortions in the width of the paper ruler and the spacings between ruler markers completely encode the size and shape of the bowl. A computational algorithm is developed to reconstruct the three-dimensional bowl interior using the observed distortions. Our experiments using nine bowls, colored liquids, and amorphous foods demonstrate high accuracy of our method for food volume estimation involving round bowls as containers. A total of 228 images of amorphous foods were also used in a comparative experiment between our algorithm and an independent human estimator. The results showed that our algorithm overperformed the human estimator who utilized different types of reference information and two estimation methods, including direct volume estimation and indirect estimation through the fullness of the bowl.
Open AccessA Novel Approach to Dining Bowl Reconstruction for Image-Based Food Volume Estimation
Knowing the amounts of energy and nutrients in an individual’s diet is important for maintaining health and preventing chronic diseases. As electronic and AI technologies advance rapidly, dietary assessment can now be performed using food images obtained from a smartphone or a wearable device. One of the challenges in this approach is to computationally measure the volume of food in a bowl from an image. This problem has not been studied systematically despite the bowl being the most utilized food container in many parts of the world, especially in Asia and Africa. In this paper, we present a new method to measure the size and shape of a bowl by adhering a paper ruler centrally across the bottom and sides of the bowl and then taking an image. When observed from the image, the distortions in the width of the paper ruler and the spacings between ruler markers completely encode the size and shape of the bowl. A computational algorithm is developed to reconstruct the three-dimensional bowl interior using the observed distortions. Our experiments using nine bowls, colored liquids, and amorphous foods demonstrate high accuracy of our method for food volume estimation involving round bowls as containers. A total of 228 images of amorphous foods were also used in a comparative experiment between our algorithm and an independent human estimator. The results showed that our algorithm overperformed the human estimator who utilized different types of reference information and two estimation methods, including direct volume estimation and indirect estimation through the fullness of the bowl.
- Open Access
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148296-148301
Mitigation of Radiation-Induced Fiber Bragg Grating (FBG) Sensor Drifts in Intense Radiation Environments Based on Long-Short-Term Memory (LSTM) Network
This paper reports in-pile testing results of radiation-resistant fiber Bragg grating (FBG) sensors at high temperatures, intense neutron irradiation environments, and machine learning methods for radiation-induced sensor drift mitigation and reactor anomaly identification. The in-pile testing of fiber sensors was carried out in an MIT test reactor for 180 days at a nominal operational temperature of 640°C and high neutron flux. The test results show that FBG sensors inscribed by a femtosecond laser in random airline pure silica fiber can withstand harsh environments in the reactor core but exhibit significant radiation-induced drifts. Machine learning algorithms based on long short-term memory (LSTM) networks have been used to detect reactor anomaly events and mitigate sensor drifts over a duration of up to 85 days. Through progressive supervised learning, the LSTM neural network can achieve FBG wavelength-to-temperature mapping within ±0.95°C, ±2.63°C and ±6.49°C with over 80.2%, 90%, and 95% levels of accuracy confidence, respectively. The LSTM can also identify reactor anomaly samples with an accuracy of over 94%. The results presented in this paper show that despite sensor drifts and anomaly interruptions, the LSTM-based method can effectively elucidate data harnessed by fiber sensors. Machine learning algorithms have the potential to improve situational awareness and control for a wide range of harsh environment applications, including nuclear power generation.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148296-148301
Open AccessMitigation of Radiation-Induced Fiber Bragg Grating (FBG) Sensor Drifts in Intense Radiation Environments Based on Long-Short-Term Memory (LSTM) Network
This paper reports in-pile testing results of radiation-resistant fiber Bragg grating (FBG) sensors at high temperatures, intense neutron irradiation environments, and machine learning methods for radiation-induced sensor drift mitigation and reactor anomaly identification. The in-pile testing of fiber sensors was carried out in an MIT test reactor for 180 days at a nominal operational temperature of 640°C and high neutron flux. The test results show that FBG sensors inscribed by a femtosecond laser in random airline pure silica fiber can withstand harsh environments in the reactor core but exhibit significant radiation-induced drifts. Machine learning algorithms based on long short-term memory (LSTM) networks have been used to detect reactor anomaly events and mitigate sensor drifts over a duration of up to 85 days. Through progressive supervised learning, the LSTM neural network can achieve FBG wavelength-to-temperature mapping within ±0.95°C, ±2.63°C and ±6.49°C with over 80.2%, 90%, and 95% levels of accuracy confidence, respectively. The LSTM can also identify reactor anomaly samples with an accuracy of over 94%. The results presented in this paper show that despite sensor drifts and anomaly interruptions, the LSTM-based method can effectively elucidate data harnessed by fiber sensors. Machine learning algorithms have the potential to improve situational awareness and control for a wide range of harsh environment applications, including nuclear power generation.