Honglin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Honglin Zhang has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
- Chengxin Zhao
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
12 shared publications - Haibo Yang
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
11 shared publications - Xiaoyang Niu
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
6 shared publications Xianqin Li
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
5 shared publicationsHu Ran
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
4 shared publicationsJianwei Liao
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
4 shared publications
Latest Publications
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3809-3816
Nupix-H1, the First Prototype MAPS for Huizhou Hadron Spectrometer at HIAF
In response to the pressing demands of high-energy nuclear physics experiments conducted at the HIAF, this paper presents the development of a prototype monolithic active pixel sensor chip, Nupix-H1, based on a domestically produced 130 nm CMOS process. The chip incorporates a 64 × 64 pixel array with the pixel size of 30 μm × 30 μm, delivering promising performance characterized by a charge-to-voltage conversion gain of 45.48 mV/ke−, an equivalent noise charge as low as 44.28 e−, and an integral nonlinearity below 1.32%. Experimental validation, including β-source tests, laser tests, and proton beam experiments, confirms that Nupix-H1 exhibits excellent energy response performance and achieves a position resolution of 4.55 ± 0.27 μm.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3809-3816
Nupix-H1, the First Prototype MAPS for Huizhou Hadron Spectrometer at HIAF
In response to the pressing demands of high-energy nuclear physics experiments conducted at the HIAF, this paper presents the development of a prototype monolithic active pixel sensor chip, Nupix-H1, based on a domestically produced 130 nm CMOS process. The chip incorporates a 64 × 64 pixel array with the pixel size of 30 μm × 30 μm, delivering promising performance characterized by a charge-to-voltage conversion gain of 45.48 mV/ke−, an equivalent noise charge as low as 44.28 e−, and an integral nonlinearity below 1.32%. Experimental validation, including β-source tests, laser tests, and proton beam experiments, confirms that Nupix-H1 exhibits excellent energy response performance and achieves a position resolution of 4.55 ± 0.27 μm.
- 2 June 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (8) , 1-16
Plan for a super η factory at Huizhou accelerator complex
- 2 June 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (8) , 1-16
Plan for a super η factory at Huizhou accelerator complex
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03040
Readout electronics of a heavy-ion beam telescope for HIAF
The beam telescope, consisting of multiple detection planes for beam tracking and calibrating position detectors, has performed excellently in various international physics experiments and equipment. This article proposes a readout electronics to fulfill the needs of a heavy-ion beam telescope at the High-Intensity Heavy-ion Accelerator Facility (HIAF). The readout electronics comprises six Common Pixel Readout Electronics (CPRs) and a Common Data Aquation Unit Version-4 (CDAU-v4). The CPR acquires the pixel detector's data, supplies the necessary bias voltages and control signals for the pixel detector, and transmits the data to the CDAU-v4 via the optical link at the speed of 10Gbps. The CDAU receives the data from the six CPRs and then transmits the data offline through the PCIe 3.0x8 interface. Lab test shows the CPR has a readout noise of 0.35 mV and a maximum Integral Non-Linearity (INL) of 0.128%. The bit error rate (BER) of the data transmission between the CPR and the CDAU-v4 is low as 1.67 × 10-15. This readout electronics has been characterized with six Topmetal-M pixel sensors to evaluate the system-level performance. The noise of all the six pixel sesors is between 78.2e- to 185.2e-. This paper will discuss the design and performance of the readout electronics.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03040
Readout electronics of a heavy-ion beam telescope for HIAF
The beam telescope, consisting of multiple detection planes for beam tracking and calibrating position detectors, has performed excellently in various international physics experiments and equipment. This article proposes a readout electronics to fulfill the needs of a heavy-ion beam telescope at the High-Intensity Heavy-ion Accelerator Facility (HIAF). The readout electronics comprises six Common Pixel Readout Electronics (CPRs) and a Common Data Aquation Unit Version-4 (CDAU-v4). The CPR acquires the pixel detector's data, supplies the necessary bias voltages and control signals for the pixel detector, and transmits the data to the CDAU-v4 via the optical link at the speed of 10Gbps. The CDAU receives the data from the six CPRs and then transmits the data offline through the PCIe 3.0x8 interface. Lab test shows the CPR has a readout noise of 0.35 mV and a maximum Integral Non-Linearity (INL) of 0.128%. The bit error rate (BER) of the data transmission between the CPR and the CDAU-v4 is low as 1.67 × 10-15. This readout electronics has been characterized with six Topmetal-M pixel sensors to evaluate the system-level performance. The noise of all the six pixel sesors is between 78.2e- to 185.2e-. This paper will discuss the design and performance of the readout electronics.
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 684-691
Prototype of Hi’Beam-SEE: A Real-Time High-Resolution Single-Event Effects Locating Device for Heavy-Ion Facilities
Integrated circuits (ICs) are widely used in spacecraft and are concerned with the probability of Single Event Effects (SEEs). To accurately locate the SEE-sensitive area of ICs, we have designed Hi’Beam-SEE for the single event effect experiment terminal at heavy-ion facilities. The Hi’Beam-SEE consists of three sub-systems: the heavy ion positioning system is responsible for locating the position of each particle within the beam, the single event detection system detects the SEEs that occurred in the device under test, and the online tracking algorithm extracts and reconstructs the position of each particle that triggers SEEs. The beam test with 84Kr18+ particles demonstrates the heavy ion positioning system can achieve a spatial resolution of 4 μm in measuring every single particle’s position. Also, the single event detection system can identify SEEs correctly and issue triggers with good timing accuracy. The online tracking algorithm can process 172 frames that contain tracks per second and extract the positions with an accuracy of 3.2 μm. In addition, it attains a rejection factor of 93.6% while keeping the signal efficiency of 99%. This paper will discuss the design and performance characterization of the Hi’Beam-SEE.
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 684-691
Prototype of Hi’Beam-SEE: A Real-Time High-Resolution Single-Event Effects Locating Device for Heavy-Ion Facilities
Integrated circuits (ICs) are widely used in spacecraft and are concerned with the probability of Single Event Effects (SEEs). To accurately locate the SEE-sensitive area of ICs, we have designed Hi’Beam-SEE for the single event effect experiment terminal at heavy-ion facilities. The Hi’Beam-SEE consists of three sub-systems: the heavy ion positioning system is responsible for locating the position of each particle within the beam, the single event detection system detects the SEEs that occurred in the device under test, and the online tracking algorithm extracts and reconstructs the position of each particle that triggers SEEs. The beam test with 84Kr18+ particles demonstrates the heavy ion positioning system can achieve a spatial resolution of 4 μm in measuring every single particle’s position. Also, the single event detection system can identify SEEs correctly and issue triggers with good timing accuracy. The online tracking algorithm can process 172 frames that contain tracks per second and extract the positions with an accuracy of 3.2 μm. In addition, it attains a rejection factor of 93.6% while keeping the signal efficiency of 99%. This paper will discuss the design and performance characterization of the Hi’Beam-SEE.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 713-719
Design of a Common High-Performance Data Acquisition System for Physics Experiments at HIAF
In this paper, a common high-performance data acquisition (DAQ) system for High Intensity heavy-ion Accelerator Facility (HIAF) centered with a new Common Data Aquation Unit (CDAU), is introduced. The system includes eight fiber optic transmission channels connected to front-end electronics, delivering data bandwidth up to 10 Gbps per channel, along with highly scalable Flexible Mezzanine Cards (FMC) and General-Purpose Input/Output (GPlO) interfaces. Moreover, a PCI Express 2.0 ×8 protocol (bandwidth up to 40 Gbps) is implemented to facilitate data exchange with data center. Laboratory characterization revealed that the Bit Error Rate (BER) of the fiber optic transmission channel is relatively low, at 5.8 × 10 −16 at a 10 Gbps transmission rate. Additionally, the read/write rates of the PCIe interface demonstrated stability, with the read speed consistently maintained at 3400 MB/s and an error rate as low as 2.09 × 10 −15 , while the write speed is stable at 3420 MB/s, with an error rate reaching 2.14 × 10 −15 . Subsequent experiments involved measuring 137 Cs radiation source and cosmic ray spectra using various scintillator detectors, achieving the energy resolution of 1.12% and 21.34%. Overall, the data acquisition system proved robust and stable in practical scenarios in HIAF. This paper examines the data acquisition system’s design and performance.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 713-719
Design of a Common High-Performance Data Acquisition System for Physics Experiments at HIAF
In this paper, a common high-performance data acquisition (DAQ) system for High Intensity heavy-ion Accelerator Facility (HIAF) centered with a new Common Data Aquation Unit (CDAU), is introduced. The system includes eight fiber optic transmission channels connected to front-end electronics, delivering data bandwidth up to 10 Gbps per channel, along with highly scalable Flexible Mezzanine Cards (FMC) and General-Purpose Input/Output (GPlO) interfaces. Moreover, a PCI Express 2.0 ×8 protocol (bandwidth up to 40 Gbps) is implemented to facilitate data exchange with data center. Laboratory characterization revealed that the Bit Error Rate (BER) of the fiber optic transmission channel is relatively low, at 5.8 × 10 −16 at a 10 Gbps transmission rate. Additionally, the read/write rates of the PCIe interface demonstrated stability, with the read speed consistently maintained at 3400 MB/s and an error rate as low as 2.09 × 10 −15 , while the write speed is stable at 3420 MB/s, with an error rate reaching 2.14 × 10 −15 . Subsequent experiments involved measuring 137 Cs radiation source and cosmic ray spectra using various scintillator detectors, achieving the energy resolution of 1.12% and 21.34%. Overall, the data acquisition system proved robust and stable in practical scenarios in HIAF. This paper examines the data acquisition system’s design and performance.
- 10 October 2024
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 35 (11) , 1-12
OML: an online multi-particle locating method for high-resolution single-event effects studies
- 10 October 2024
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 35 (11) , 1-12
OML: an online multi-particle locating method for high-resolution single-event effects studies
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 600-607
The IMPix-S, a Silicon Pixel Sensor for Gaseous Detector at HIRFL and HIAF
The Heavy Ion Research Facility in Lanzhou (HIRFL) and the High-Intensity Heavy-ion Accelerator Facility (HIAF) are advanced heavy-ion accelerators that play a critical role in pursuing a deeper understanding of nuclear physics. The development of high-performance gaseous detectors at HIRFL and HIAF poses broad requirements on silicon pixel sensors. Hence, we have designed the IMPix-S, a silicon pixel sensor that can collect charge directly from its surrounding media. It has 64 rows × 120 columns of square pixels, with a size of 37 μm × 37 μm. Each pixel can measure the position, energy, and time of arrival. Laboratory test results show that energy measurement achieves an INL of better than 1% and an ENC of ~ 50 e - to 145 e - with a dynamic range of up to 18.3 ke - . The accuracy in the time measurement path is around 300 ns to 500 ns with an effective range of 10 μs. In addition, the IMPix-S achieves a spatial resolution of ~ 2.6 μm in measuring the laser beam and ~ 1.836 μm in measuring 181 Ta 35+ tracks. This paper will discuss the design and performance of this IMPix-S silicon pixel sensor.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 600-607
The IMPix-S, a Silicon Pixel Sensor for Gaseous Detector at HIRFL and HIAF
The Heavy Ion Research Facility in Lanzhou (HIRFL) and the High-Intensity Heavy-ion Accelerator Facility (HIAF) are advanced heavy-ion accelerators that play a critical role in pursuing a deeper understanding of nuclear physics. The development of high-performance gaseous detectors at HIRFL and HIAF poses broad requirements on silicon pixel sensors. Hence, we have designed the IMPix-S, a silicon pixel sensor that can collect charge directly from its surrounding media. It has 64 rows × 120 columns of square pixels, with a size of 37 μm × 37 μm. Each pixel can measure the position, energy, and time of arrival. Laboratory test results show that energy measurement achieves an INL of better than 1% and an ENC of ~ 50 e - to 145 e - with a dynamic range of up to 18.3 ke - . The accuracy in the time measurement path is around 300 ns to 500 ns with an effective range of 10 μs. In addition, the IMPix-S achieves a spatial resolution of ~ 2.6 μm in measuring the laser beam and ~ 1.836 μm in measuring 181 Ta 35+ tracks. This paper will discuss the design and performance of this IMPix-S silicon pixel sensor.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 454-461
Prototype Design of Readout Electronics for the Multiple Sampling Ionization Chamber at HIAF-HFRS
Nuclear physics using radioactive beams has been the most dynamic research area in nuclear science. A High Intensity Heavy-Ion Accelerator Facility (HIAF) is currently under construction, which includes the installation of a cuttingedge High Energy Fragment Separator (HFRS) with high energy and intensity capabilities. The HFRS uses the magnetic-rigidity-time-of-flight-energy-loss (Bρ-TOF-ΔE) method, which has been commonly used in nuclear fragmentation secondary beam devices to achieve high magnetic rigidity, large ion-optical acceptance, and excellent particle identification. The energy loss (ΔE) detector plays a crucial role in particle identification. The energy loss detector is designed using the multiple sampling ionization chamber (MUSIC) detector. It can significantly improve the energy resolution of the gas ionization chamber through multiple samplings. The prototype of the readout electronics of one MUSIC consists of eight charge-sensitive preamplifiers (CSPs) modules and one readout control electronics (RCE) module. The CSPs placed inside the MUSIC read the MUSIC charge signals. A RCE has eight signal input channels. The RCE receives voltage signal pulses from the CSPs, amplifies, filters, and digitizes the signal. The measured data is packed and transferred to the data acquisition (DAQ) system via a 10-Gb ethernet protocol. The readout electronics have been tested. The test results indicate that the noise performance is better than 0.22 mV (i.e., the root mean square (RMS) error), and the nonlinearity of the entire readout electronics is less than 0.17%. The joint test results of the MUSIC detector show that it has an excellent performance in measuring the radioactive source and heavy-ion beams. This paper will discuss the design and performance of the readout electronics.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 454-461
Prototype Design of Readout Electronics for the Multiple Sampling Ionization Chamber at HIAF-HFRS
Nuclear physics using radioactive beams has been the most dynamic research area in nuclear science. A High Intensity Heavy-Ion Accelerator Facility (HIAF) is currently under construction, which includes the installation of a cuttingedge High Energy Fragment Separator (HFRS) with high energy and intensity capabilities. The HFRS uses the magnetic-rigidity-time-of-flight-energy-loss (Bρ-TOF-ΔE) method, which has been commonly used in nuclear fragmentation secondary beam devices to achieve high magnetic rigidity, large ion-optical acceptance, and excellent particle identification. The energy loss (ΔE) detector plays a crucial role in particle identification. The energy loss detector is designed using the multiple sampling ionization chamber (MUSIC) detector. It can significantly improve the energy resolution of the gas ionization chamber through multiple samplings. The prototype of the readout electronics of one MUSIC consists of eight charge-sensitive preamplifiers (CSPs) modules and one readout control electronics (RCE) module. The CSPs placed inside the MUSIC read the MUSIC charge signals. A RCE has eight signal input channels. The RCE receives voltage signal pulses from the CSPs, amplifies, filters, and digitizes the signal. The measured data is packed and transferred to the data acquisition (DAQ) system via a 10-Gb ethernet protocol. The readout electronics have been tested. The test results indicate that the noise performance is better than 0.22 mV (i.e., the root mean square (RMS) error), and the nonlinearity of the entire readout electronics is less than 0.17%. The joint test results of the MUSIC detector show that it has an excellent performance in measuring the radioactive source and heavy-ion beams. This paper will discuss the design and performance of the readout electronics.