Michael Farias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Farias has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alain J. Kassab
Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
2 shared publications - Arka Das
Department of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA
2 shared publications - Eduardo Divo
Department of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA
2 shared publications - William M. DeCampli
Division of Pediatric Cardiac Surgery, Arnold Palmer Hospital for Children, Orlando, FL, USA
2 shared publications - David Nykanen
Orlando Health Arnold Palmer Children's Hospital, Orlando, Florida, USA
1 shared publication - Marwan Hameed
Department of Mechanical Engineering, American University of Bahrain, Riffa 942, Bahrain
1 shared publication
Latest Publications
- Open Access
- 19 January 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 135
In-Silico and In-Vitro Analysis of the Novel Hybrid Comprehensive Stage II Operation for Single Ventricle Circulation
Single ventricle (SV) anomalies account for one-fourth of all congenital heart disease cases. The existing palliative treatment for this anomaly achieves a survival rate of only 50%. To reduce the trauma associated with surgical management, the hybrid comprehensive stage II (HCSII) operation was designed as an alternative for a select subset of SV patients with the adequate antegrade aortic flow. This study aims to provide better insight into the hemodynamics of HCSII patients utilizing a multiscale Computational Fluid Dynamics (CFD) model and a mock flow loop (MFL). Both 3D-0D loosely coupled CFD and MFL models have been tuned to match baseline hemodynamic parameters obtained from patient-specific catheterization data. The hemodynamic findings from clinical data closely match the in-vitro and in-silico measurements and show a strong correlation (r = 0.9). The geometrical modification applied to the models had little effect on the oxygen delivery. Similarly, the particle residence time study reveals that particles injected in the main pulmonary artery (MPA) have successfully ejected within one cardiac cycle, and no pathological flows were observed.
- 19 January 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 135
Open AccessIn-Silico and In-Vitro Analysis of the Novel Hybrid Comprehensive Stage II Operation for Single Ventricle Circulation
Single ventricle (SV) anomalies account for one-fourth of all congenital heart disease cases. The existing palliative treatment for this anomaly achieves a survival rate of only 50%. To reduce the trauma associated with surgical management, the hybrid comprehensive stage II (HCSII) operation was designed as an alternative for a select subset of SV patients with the adequate antegrade aortic flow. This study aims to provide better insight into the hemodynamics of HCSII patients utilizing a multiscale Computational Fluid Dynamics (CFD) model and a mock flow loop (MFL). Both 3D-0D loosely coupled CFD and MFL models have been tuned to match baseline hemodynamic parameters obtained from patient-specific catheterization data. The hemodynamic findings from clinical data closely match the in-vitro and in-silico measurements and show a strong correlation (r = 0.9). The geometrical modification applied to the models had little effect on the oxygen delivery. Similarly, the particle residence time study reveals that particles injected in the main pulmonary artery (MPA) have successfully ejected within one cardiac cycle, and no pathological flows were observed.
- Open Access
In-Vitro Validation of Self-Powered Fontan Circulation for Treatment of Single Ventricle Anomaly
Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as palliation for this anomaly for decades, but the surgery entails multiple complications, and the survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A dynamically scaled Mock Flow Loop (MFL) has been configured to validate this hypothesis. Three IJS nozzles of varying diameters 2, 3, and 4 mm with three aortic anastomosis angles and pulmonary vascular resistance (PVR) reduction have been tested to validate the hypothesis and optimize the caval pressure reduction. The MFL is based on a Lumped-Parameter Model (LPM) of a non-fenestrated Fontan circulation. The best outcome was achieved with the experimental testing of a 3 mm IJS by producing an average caval pressure reduction of more than 5 mmHg while maintaining the clinically acceptable pulmonary flow rate (Qp) to systemic flow rate (Qs) ratio of ~1.5. Furthermore, alteration of the PVR helped in achieving higher caval pressure reduction with the 3 mm IJS at the expense of an increase in Qp/Qs ratio.
Open AccessIn-Vitro Validation of Self-Powered Fontan Circulation for Treatment of Single Ventricle Anomaly
Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as palliation for this anomaly for decades, but the surgery entails multiple complications, and the survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A dynamically scaled Mock Flow Loop (MFL) has been configured to validate this hypothesis. Three IJS nozzles of varying diameters 2, 3, and 4 mm with three aortic anastomosis angles and pulmonary vascular resistance (PVR) reduction have been tested to validate the hypothesis and optimize the caval pressure reduction. The MFL is based on a Lumped-Parameter Model (LPM) of a non-fenestrated Fontan circulation. The best outcome was achieved with the experimental testing of a 3 mm IJS by producing an average caval pressure reduction of more than 5 mmHg while maintaining the clinically acceptable pulmonary flow rate (Qp) to systemic flow rate (Qs) ratio of ~1.5. Furthermore, alteration of the PVR helped in achieving higher caval pressure reduction with the 3 mm IJS at the expense of an increase in Qp/Qs ratio.