Jin Kawakita
Jin Kawakita has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Moataz Mekawy
Department of Neurosurgery, Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan
6 shared publications - Yoshio Sakka
National Institute for Materials Science
4 shared publications Mamiko Kawakita
Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8571, Japan; and Nano Ceramics Center, National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba 305-0047, Japan
3 shared publicationsMoataz Mekawy
3 shared publications- Rekha Goswami Shrestha
International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba 305-0044, Ibaraki, Japan
3 shared publications Seiji Kuroda
National Institute for Materials Science, 1-2-1, Sengen, Tsukuba 305-0047, Japan
3 shared publications
Latest Publications
- Open Access
- 18 August 2025
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 20
Surface modification of aluminum on a silicon chip by citric acid treatment
- 18 August 2025
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 20
Open AccessSurface modification of aluminum on a silicon chip by citric acid treatment
- 1 December 2023
- Published by Elsevier in Bioresource Technology Reports
- Vol. 25
Temperature-controlled direct detection of volatile fatty acids by a membrane-covered moisture sensor
- 1 December 2023
- Published by Elsevier in Bioresource Technology Reports
- Vol. 25
Temperature-controlled direct detection of volatile fatty acids by a membrane-covered moisture sensor
- 24 November 2023
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 28 (1) , 46-58
Refinement of Thermal Conduction-Based Dew Condensation Detection on Target Solid Surface by Galvanic Arrays Sensor Chip
- 24 November 2023
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 28 (1) , 46-58
Refinement of Thermal Conduction-Based Dew Condensation Detection on Target Solid Surface by Galvanic Arrays Sensor Chip
- Open Access
- 14 November 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (11) , 564
Water Vapor Condensation in Nanoparticle Films: Physicochemical Analysis and Application to Rapid Vapor Sensing
Nanomaterial-based humidity sensors hold great promise for water vapor detection because of their high sensitivity and fast response/recovery. However, the condensation of water in nanomaterial films remains unclear from a physicochemical perspective. Herein, the condensation of water vapor in silica nanoparticle films was physicochemically analyzed to bridge the abovementioned gap. The morphology of surface-adsorbed water molecules was characterized using infrared absorption spectroscopy and soft X-ray absorption spectroscopy, and the effect of RH on the amount of adsorbed water was observed using a quartz crystal microbalance. The adsorbed water was found to exist in liquid- and ice-like states, which contributed to high and low conductivity, respectively. The large change in film impedance above 80% RH was ascribed to the condensation of water between the nanoparticles. Moreover, RH alteration resulted in a colorimetric change in the film’s interference fringe. The obtained insights were used to construct a portable device with response and recovery times suitable for the real-time monitoring of water vapor. Thus, this study clarifies the structure of water adsorbed on nanomaterial surfaces and, hence, the action mechanism of the corresponding nanoparticle-based sensors, inspiring further research on the application of various nanomaterials to vapor sensing.
- 14 November 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (11) , 564
Open AccessWater Vapor Condensation in Nanoparticle Films: Physicochemical Analysis and Application to Rapid Vapor Sensing
Nanomaterial-based humidity sensors hold great promise for water vapor detection because of their high sensitivity and fast response/recovery. However, the condensation of water in nanomaterial films remains unclear from a physicochemical perspective. Herein, the condensation of water vapor in silica nanoparticle films was physicochemically analyzed to bridge the abovementioned gap. The morphology of surface-adsorbed water molecules was characterized using infrared absorption spectroscopy and soft X-ray absorption spectroscopy, and the effect of RH on the amount of adsorbed water was observed using a quartz crystal microbalance. The adsorbed water was found to exist in liquid- and ice-like states, which contributed to high and low conductivity, respectively. The large change in film impedance above 80% RH was ascribed to the condensation of water between the nanoparticles. Moreover, RH alteration resulted in a colorimetric change in the film’s interference fringe. The obtained insights were used to construct a portable device with response and recovery times suitable for the real-time monitoring of water vapor. Thus, this study clarifies the structure of water adsorbed on nanomaterial surfaces and, hence, the action mechanism of the corresponding nanoparticle-based sensors, inspiring further research on the application of various nanomaterials to vapor sensing.
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 087505
Continuously Activated Function of Aluminum in Galvanic Micro Arrays in Contact with Water
Galvanic coupled arrays of Aluminum (Al) and Gold (Au) aligned in microgap has displayed high accuracy and sensitivity towards detection of invisibly small water droplets. With Al in moisture sensing chip, 1) formation of Al2O3 layer around Al and 2) decay of Al electrode with time, may interfere its overall activity. In this study, a continuous activation of Al electrode on the sensor chip was performed and investigated through electrochemical evaluation, output current measurement, and SEM observations. Further pH in its vicinity was simulated for ∼2 years. The results showed that a sensing chip exhibits almost steady output current throughout the period. At relatively high current density of 1.25 × 10−6 A.cm−2, obtained in the short circuit, anodic reaction on the Al electrode generates protons. This production of protons reduces the pH to ∼4, where Al2O3 and Al3+ formed on its surface could get dissolved. In addition, Al consumption in 100 ms, i.e. the time for one closed circuit corresponds to 2.26 × 10−17 g.A−1 s−1, which is negligible. The SEM images confirmed unchanged morphology of Al electrodes. The results support the long-term stability of accurate and sensitive sensor chip with galvanic array of Al and Au electrodes.
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 087505
Continuously Activated Function of Aluminum in Galvanic Micro Arrays in Contact with Water
Galvanic coupled arrays of Aluminum (Al) and Gold (Au) aligned in microgap has displayed high accuracy and sensitivity towards detection of invisibly small water droplets. With Al in moisture sensing chip, 1) formation of Al2O3 layer around Al and 2) decay of Al electrode with time, may interfere its overall activity. In this study, a continuous activation of Al electrode on the sensor chip was performed and investigated through electrochemical evaluation, output current measurement, and SEM observations. Further pH in its vicinity was simulated for ∼2 years. The results showed that a sensing chip exhibits almost steady output current throughout the period. At relatively high current density of 1.25 × 10−6 A.cm−2, obtained in the short circuit, anodic reaction on the Al electrode generates protons. This production of protons reduces the pH to ∼4, where Al2O3 and Al3+ formed on its surface could get dissolved. In addition, Al consumption in 100 ms, i.e. the time for one closed circuit corresponds to 2.26 × 10−17 g.A−1 s−1, which is negligible. The SEM images confirmed unchanged morphology of Al electrodes. The results support the long-term stability of accurate and sensitive sensor chip with galvanic array of Al and Au electrodes.
- Open Access
- 29 November 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (53) , 34694-34703
Frost formation through super-cooled water within micron gap of galvanic coupled arrays
Frost is considered one of the key factors that negatively affects numerous daily life aspects all over the globe such as growth of crops, safety of aviation and transportation vehicles, working efficiency of air circulating systems and many others. Therefore, monitoring and early detection of frost are crucially needed to avoid such drastic effects. In this study, we used the micron gap of our newly developed galvanic coupled arrays named as moisture sensor chip (MSC) for the early detection of frost formation from super-cooled water droplets. The early frost formation was monitored via the tiny ice crystals formed on the cooled MSC surface at four different humidity levels using simultaneous electrochemical and optical microscopic detection tools. Experimental results revealed for the first time a remarkable increase in the detected galvanic current due to the condensation frosting mechanism of super-cooled water droplets via liquid transition transformation even at very low relative humidity which was believed to be responsible for de-sublimation frosting. Moreover, the super-cooled droplets formed ice bridges along their boundary domains due to the accumulation of the acquired water vapour that was evidenced by the release of the heat of solidification. These findings demonstrated that the MSC could be used as a promising platform for the early detection of frost formation considering the appropriate protective measures against its adverse effects.
- 29 November 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (53) , 34694-34703
Open AccessFrost formation through super-cooled water within micron gap of galvanic coupled arrays
Frost is considered one of the key factors that negatively affects numerous daily life aspects all over the globe such as growth of crops, safety of aviation and transportation vehicles, working efficiency of air circulating systems and many others. Therefore, monitoring and early detection of frost are crucially needed to avoid such drastic effects. In this study, we used the micron gap of our newly developed galvanic coupled arrays named as moisture sensor chip (MSC) for the early detection of frost formation from super-cooled water droplets. The early frost formation was monitored via the tiny ice crystals formed on the cooled MSC surface at four different humidity levels using simultaneous electrochemical and optical microscopic detection tools. Experimental results revealed for the first time a remarkable increase in the detected galvanic current due to the condensation frosting mechanism of super-cooled water droplets via liquid transition transformation even at very low relative humidity which was believed to be responsible for de-sublimation frosting. Moreover, the super-cooled droplets formed ice bridges along their boundary domains due to the accumulation of the acquired water vapour that was evidenced by the release of the heat of solidification. These findings demonstrated that the MSC could be used as a promising platform for the early detection of frost formation considering the appropriate protective measures against its adverse effects.
- Open Access
- 30 July 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (8) , 300
Quantitative Correlation between Adsorbed and Condensed Water Mass with Response Galvanic Current Detected at the Micron Gap of Galvanic-Coupled Arrays
Sensor surfaces with micron- and nano-gap scales possess high surface-to-volume ratio which greatly affects their contribution towards water adsorption and condensation. However, the quantitative relationship between adsorbed water molecules and condensed water droplets remains unclear. In this study, we used the humidity-based detected galvanic current within the micron gaps of our newly developed moisture sensor chip (MSC) to emphasize the quantitative relationship between adsorbed water molecules and condensed water droplets. The mass of adsorbed water molecules was detected using a quartz-crystal-microbalance electrode (QCM) whereas the mass of condensed water droplets was estimated microscopically based on their occupying volumes at MSC surface. Experimental results demonstrated that the minimum detection limit of MSC under these experimental conditions was ~150 ng/cm2 for adsorbed water molecules and ~700 ng/ cm2 for condensed water droplets. The detected-response galvanic current arises when a water bridges between two adjacent arrays is found to be linearly correlated to the adsorbed and/or the condensed water’s mass. Such correlation is believed to provide a feasible long-range sensor that can distinguish the status of its surface-existing water either in adsorbed molecular or condensed droplet-wise regimes.
- 30 July 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (8) , 300
Open AccessQuantitative Correlation between Adsorbed and Condensed Water Mass with Response Galvanic Current Detected at the Micron Gap of Galvanic-Coupled Arrays
Sensor surfaces with micron- and nano-gap scales possess high surface-to-volume ratio which greatly affects their contribution towards water adsorption and condensation. However, the quantitative relationship between adsorbed water molecules and condensed water droplets remains unclear. In this study, we used the humidity-based detected galvanic current within the micron gaps of our newly developed moisture sensor chip (MSC) to emphasize the quantitative relationship between adsorbed water molecules and condensed water droplets. The mass of adsorbed water molecules was detected using a quartz-crystal-microbalance electrode (QCM) whereas the mass of condensed water droplets was estimated microscopically based on their occupying volumes at MSC surface. Experimental results demonstrated that the minimum detection limit of MSC under these experimental conditions was ~150 ng/cm2 for adsorbed water molecules and ~700 ng/ cm2 for condensed water droplets. The detected-response galvanic current arises when a water bridges between two adjacent arrays is found to be linearly correlated to the adsorbed and/or the condensed water’s mass. Such correlation is believed to provide a feasible long-range sensor that can distinguish the status of its surface-existing water either in adsorbed molecular or condensed droplet-wise regimes.
- Open Access
- 14 March 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (3) , 112
Recent Sensing Technologies of Imperceptible Water in Atmosphere
Accurate detection and quantitative evaluation of environmental water in vapor and liquids state expressed as humidity and precipitation play key roles in industrial and scientific applications. However, the development of supporting tools and techniques remains a challenge. Although optical methods such as IR and LASER could detect environmental water in the air, their apparatus is relatively huge. Alternatively, solid detection field systems (SDFSs) could recently lead to a revolution in device downsizing and sensing abilities via advanced research, mainly for materials technology. Herein, we present an overview of several SDFS based sensing categories and their core materials mainly used to detect water in atmosphere, either in the vapor or liquid phase. We considered the governing mechanism in the detection process, such as adsorption/desorption, condensation/evaporation for the vapor phase, and surface attach/detach for the liquid phase. Sensing categories such as optical, chilled mirror, resistive, capacitive, gravimetric sensors were reviewed together with their designated tools such as acoustic wave, quartz crystal microbalance, IDT, and many others, giving typical examples of daily based real scientific applications.
- 14 March 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (3) , 112
Open AccessRecent Sensing Technologies of Imperceptible Water in Atmosphere
Accurate detection and quantitative evaluation of environmental water in vapor and liquids state expressed as humidity and precipitation play key roles in industrial and scientific applications. However, the development of supporting tools and techniques remains a challenge. Although optical methods such as IR and LASER could detect environmental water in the air, their apparatus is relatively huge. Alternatively, solid detection field systems (SDFSs) could recently lead to a revolution in device downsizing and sensing abilities via advanced research, mainly for materials technology. Herein, we present an overview of several SDFS based sensing categories and their core materials mainly used to detect water in atmosphere, either in the vapor or liquid phase. We considered the governing mechanism in the detection process, such as adsorption/desorption, condensation/evaporation for the vapor phase, and surface attach/detach for the liquid phase. Sensing categories such as optical, chilled mirror, resistive, capacitive, gravimetric sensors were reviewed together with their designated tools such as acoustic wave, quartz crystal microbalance, IDT, and many others, giving typical examples of daily based real scientific applications.
- 7 January 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 613, 311-319
Quantitative and qualitative studies for real monitoring of interfacial molecular water
- 7 January 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 613, 311-319
Quantitative and qualitative studies for real monitoring of interfacial molecular water