Piroska Víg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Piroska Víg has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Istvan Farkas
Hungarian Uni- versity of Agriculture and Life Sciences, Hungary
7 shared publications - Ahssan M.A. Alshibil
Doctoral School of Mechanical Engineering, Hungarian University of Agriculture and Life Sciences, Gödöllő, Hungary
3 shared publications Ahmed M. Ajeena
2 shared publications- Ahmed M. Ajeena
Doctoral School of Mechanical Engineering, Hungarian University of Agriculture and Life Sciences, Szent István campus, Páter K. u. 1, Gödöllő H-2100, Hungary
1 shared publication - Aschenaki Tadesse Altaye
Doctoral School of Mechanical Engineering, Hungarian University of Agriculture and Life Sciences, Gödöllő, Hungary
1 shared publication - István Seres
Hungarian Univ Agr & Life Sci MATE, Dept Phys, Pater K Ut 1, H-2100 Godollo, Hungary
1 shared publication
Latest Publications
- Open Access
- 16 October 2026
- Published by Elsevier in Results in Engineering
COUPLED ELECTRO-THERMAL DYNAMIC SIMULATION OF A WATER-COOLED PHOTOVOLTAIC/THERMAL COLLECTOR UNDER CONTRASTING CLIMATIC CONDITIONS USING TRNSYS
- 16 October 2026
- Published by Elsevier in Results in Engineering
Open AccessCOUPLED ELECTRO-THERMAL DYNAMIC SIMULATION OF A WATER-COOLED PHOTOVOLTAIC/THERMAL COLLECTOR UNDER CONTRASTING CLIMATIC CONDITIONS USING TRNSYS
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Acta Technologica Agriculturae
- Vol. 29 (3) , 188-197
Experimental Study of Module Elevation and Ground Cover Type on Photovoltaic Performance
This experimental study systematically explores the effects of elevation height and ground surface condition on the thermal and electrical performance of photovoltaic modules based on monocrystalline silicon photovoltaic modules under field conditions in a subtropical climate. Three identical 60 W monofacial PV modules were installed at heights of 0.7 m, 1.1 m, and 1.6 m above dried grass and vegetation-covered surfaces to assess the influence of airflow, albedo, and microclimatic cooling. Voltage, current, ambient air speed, ambient pressure, temperature, and irradiance were continuously recorded using high-precision dataloggers. Results show that module elevation strongly affects operating temperature and electrical efficiency, with the 1.1 m height yielding the highest power output (maximum 45.2 W) and conversion efficiency (7.0%). Vegetation reduced cell temperature through evapotranspiration, enhancing performance, while dried grass increased heat accumulation. Despite slightly higher irradiance above dried grass, modules over vegetation performed more efficiently. Overall, a moderate elevation and vegetative cover improve PV cooling and efficiency, offering an effective strategy for optimising agrivoltaic and eco-integrated PV systems.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Acta Technologica Agriculturae
- Vol. 29 (3) , 188-197
Open AccessExperimental Study of Module Elevation and Ground Cover Type on Photovoltaic Performance
This experimental study systematically explores the effects of elevation height and ground surface condition on the thermal and electrical performance of photovoltaic modules based on monocrystalline silicon photovoltaic modules under field conditions in a subtropical climate. Three identical 60 W monofacial PV modules were installed at heights of 0.7 m, 1.1 m, and 1.6 m above dried grass and vegetation-covered surfaces to assess the influence of airflow, albedo, and microclimatic cooling. Voltage, current, ambient air speed, ambient pressure, temperature, and irradiance were continuously recorded using high-precision dataloggers. Results show that module elevation strongly affects operating temperature and electrical efficiency, with the 1.1 m height yielding the highest power output (maximum 45.2 W) and conversion efficiency (7.0%). Vegetation reduced cell temperature through evapotranspiration, enhancing performance, while dried grass increased heat accumulation. Despite slightly higher irradiance above dried grass, modules over vegetation performed more efficiently. Overall, a moderate elevation and vegetative cover improve PV cooling and efficiency, offering an effective strategy for optimising agrivoltaic and eco-integrated PV systems.
- Open Access
- 7 December 2024
- Published by Elsevier in Results in Engineering
- Vol. 25
Quantitative assessment of reflected light characteristics on solar panel
- 7 December 2024
- Published by Elsevier in Results in Engineering
- Vol. 25
Open AccessQuantitative assessment of reflected light characteristics on solar panel
- Open Access
- 19 August 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (1) , 713-720
Experimental Comparison of Glazed and Unglazed Hybrid Solar Modules Considering Power Productivity and Cell Temperature
This study presents the effect of cell temperature on the hybrid solar collectors PV/T for modules with and without using a front glass cover. A numerical model of thermal behaviour was carried out for glazed (PV/Tg ) and unglazed (PV/Tun) modules. As a result of this experimental investigation conducted for presented PV/T modules, a sufficient decrease in the cell temperature of PV/Tun compared to the PV/Tg, PV/Tun module exceeded the PV/Tg by 19%. Thus, the electrical productivity of the PV/Tun module was higher; it was 3.44% higher than the PV/Tg value. The outlet liquid temperature of the un-covered module was 6.34% higher than the outlet liquid temperature of the glass-covered module. Besides, the total efficiency of the PV/Tg was higher during the periods of study. In this sense, the glass-covered module is preferable for applications that deal with overall efficiency as a desirable factor. The un-covered module is much beneficial for applications that need high electrical productivity.
- 19 August 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (1) , 713-720
Open AccessExperimental Comparison of Glazed and Unglazed Hybrid Solar Modules Considering Power Productivity and Cell Temperature
This study presents the effect of cell temperature on the hybrid solar collectors PV/T for modules with and without using a front glass cover. A numerical model of thermal behaviour was carried out for glazed (PV/Tg ) and unglazed (PV/Tun) modules. As a result of this experimental investigation conducted for presented PV/T modules, a sufficient decrease in the cell temperature of PV/Tun compared to the PV/Tg, PV/Tun module exceeded the PV/Tg by 19%. Thus, the electrical productivity of the PV/Tun module was higher; it was 3.44% higher than the PV/Tg value. The outlet liquid temperature of the un-covered module was 6.34% higher than the outlet liquid temperature of the glass-covered module. Besides, the total efficiency of the PV/Tg was higher during the periods of study. In this sense, the glass-covered module is preferable for applications that deal with overall efficiency as a desirable factor. The un-covered module is much beneficial for applications that need high electrical productivity.
- Open Access
- 1 July 2024
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 28 (4) , 473-479
Performance Assessments of Direct Contact Serpentine Tube Based Photovoltaic Thermal Module: An Experimental Comparison
Solar energy is the most focused in the field of renewable energy. It is a clean, green, environmentally friendly energy source. One of the modern technologies utilized by researchers to investigate the wasted heat by the photovoltaic module is the photovoltaic thermal collector, which simultaneously provides thermal and electrical power for various engineering applications. This study presented a new configuration of a water-cooled photovoltaic thermal module that utilizes a copper serpentine tube attached directly using thermal silicon to the poly-crystalline PV module for water circulation. The created PV/T was well-insulated using fiber material, insulation cork, and Wooden parts. The water flow was circulated via a DC pump with low power consumption. The fabricated unit was compared to the standalone photovoltaic module for the performance evaluation. The main result showed a significant enhancement in the electrical productivity of the photovoltaic thermal module compared to the standalone unit. The cell temperature was reduced by 13.3% compared to the standalone photovoltaic module. Accordingly, the water-based PV/T module effectively eliminated the heat dissipated to the surrounding region by the PV module by using a serpentine tube, assuring sustainable contribution.
- 1 July 2024
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 28 (4) , 473-479
Open AccessPerformance Assessments of Direct Contact Serpentine Tube Based Photovoltaic Thermal Module: An Experimental Comparison
Solar energy is the most focused in the field of renewable energy. It is a clean, green, environmentally friendly energy source. One of the modern technologies utilized by researchers to investigate the wasted heat by the photovoltaic module is the photovoltaic thermal collector, which simultaneously provides thermal and electrical power for various engineering applications. This study presented a new configuration of a water-cooled photovoltaic thermal module that utilizes a copper serpentine tube attached directly using thermal silicon to the poly-crystalline PV module for water circulation. The created PV/T was well-insulated using fiber material, insulation cork, and Wooden parts. The water flow was circulated via a DC pump with low power consumption. The fabricated unit was compared to the standalone photovoltaic module for the performance evaluation. The main result showed a significant enhancement in the electrical productivity of the photovoltaic thermal module compared to the standalone unit. The cell temperature was reduced by 13.3% compared to the standalone photovoltaic module. Accordingly, the water-based PV/T module effectively eliminated the heat dissipated to the surrounding region by the PV module by using a serpentine tube, assuring sustainable contribution.
- Open Access
- 22 September 2023
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 20
Performance enhancement of flat plate solar collector using ZrO2-SiC/DW hybrid nanofluid: A comprehensive experimental study
- 22 September 2023
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 20
Open AccessPerformance enhancement of flat plate solar collector using ZrO2-SiC/DW hybrid nanofluid: A comprehensive experimental study
- 25 January 2023
- Published by Elsevier in Solar Energy
- Vol. 251, 366-381
Optical effects of water droplets on the performance of solar cell covered with a hydrophobic thin layer
- 25 January 2023
- Published by Elsevier in Solar Energy
- Vol. 251, 366-381
Optical effects of water droplets on the performance of solar cell covered with a hydrophobic thin layer