Shaheen N. Awan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shaheen N. Awan has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
David A. Eddins
6 shared publications- Yeonggwang Park
School of Communication Sciences and Disorders, University of Central Florida, Orlando
5 shared publications - Amanda I. Gillespie
Emory University School of Medicine, Department of Otolaryngology, Atlanta, Georgia
4 shared publications - Rahul Shrivastav
Department of Speech, Language, and Hearing Sciences, Indiana University Bloomington
4 shared publications - Jordan A. Awan
Deptartment of Statistics, Purdue University, West Lafayette, Indiana
3 shared publications Jun Chen
3 shared publications
Latest Publications
- 19 November 2026
- Published by Elsevier in Journal of Voice
A Novel High Flow Vortex Whistle System for Measurement of FVC and FEV1
- 19 November 2026
- Published by Elsevier in Journal of Voice
A Novel High Flow Vortex Whistle System for Measurement of FVC and FEV1
- 10 November 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (11) , 5225-5236
Effect of Vowel Type on Aerodynamic Measures of Estimated Subglottal Pressure and Airflow
Introduction: The purpose of this study was to investigate the potential effect of factors such as tongue height and advancement and vocal tract constrictions on aerodynamic measures of voice (mean airflow [MAF] and estimated subglottal pressure [Psub]). A key question was whether the choice of elicitation vowel would have a substantial impact on normative expectations and subsequent clinical decision making that may be based on measures of MAF or Psub. Method: Forty-three nondysphonic male ( n = 13) and female ( n = 30) participants between the ages of 18 and 30 years were tested using the Phonatory Aerodynamic System (Model 6600, Pentax Medical Inc.). MAF was measured from sustained vowels /i/, /u/, and /α/ in their comfortable pitch and loudness using the comfortable sustained phonation protocol. MAF and Psub were also measured from repetitions of the syllable /pV/, where V was the target vowel (/i, u, α/. Measurement of vocal fundamental frequency ( F 0) during vowel production in the aforementioned protocols was also measured. The order of sustained vowel versus syllable production tasks and the target vowels were counterbalanced across subjects. Results: Analysis of MAF in comfortable sustained phonation showed a significant main effect of vowel type (small effect size), with post hoc analysis indicating that the MAF observed for /i/ was significantly lower than that observed for /α/ (0.139 vs. 0.152 L/s, respectively). MAF for the vowel /u/ fell in between (0.147 L/s), with differences in MAF between /i/ versus /u/ and /α/ versus /u/ being nonsignificant. In contrast, the analysis of MAF in syllable context showed no significant main effect of vowel. The main effect of vowel was significant for measures of Psub obtained in the syllable context (small effect size), with syllables including the high-impedance vowel /i/ observed to have significantly higher Psub compared with syllables including the low-impedance vowel /α/ (7.96 vs. 7.54 cm H 2 O, respectively). Mean Psub for the syllables including /u/ was again observed to fall in between (7.64 cm H 2 O), with differences in Psub between /i/ versus /u/ and /α/ versus /u/ being nonsignificant. Measures of MAF and Psub from different vowel contexts were highly correlated. Vocal F 0 was not observed to be a significant predictor of MAF or Psub. Conclusions: Although the generally small effect sizes for the effect of vowel type on aerodynamic measures indicate that this finding may be of little practical significance, the results of this study support the view that vowel type has a predictable and measurable effect on measures of MAF (in comfortable sustained phonation) and Psub in syllable context. Supraglottal impedance changes secondary to articulatory differences between vowels are primarily responsible for the differences between vowels on MAF and Psub versus F 0-related changes in laryngeal activity that may accompany different vowel productions. The results of this study indicate that vowel type should not have any substantial effect on normative expectations for MAF or Psub, and linear regression equations may be used to convert aerodynamic measures of MAF and Psub between different vowels with relatively little error.
- 10 November 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (11) , 5225-5236
Effect of Vowel Type on Aerodynamic Measures of Estimated Subglottal Pressure and Airflow
Introduction: The purpose of this study was to investigate the potential effect of factors such as tongue height and advancement and vocal tract constrictions on aerodynamic measures of voice (mean airflow [MAF] and estimated subglottal pressure [Psub]). A key question was whether the choice of elicitation vowel would have a substantial impact on normative expectations and subsequent clinical decision making that may be based on measures of MAF or Psub. Method: Forty-three nondysphonic male ( n = 13) and female ( n = 30) participants between the ages of 18 and 30 years were tested using the Phonatory Aerodynamic System (Model 6600, Pentax Medical Inc.). MAF was measured from sustained vowels /i/, /u/, and /α/ in their comfortable pitch and loudness using the comfortable sustained phonation protocol. MAF and Psub were also measured from repetitions of the syllable /pV/, where V was the target vowel (/i, u, α/. Measurement of vocal fundamental frequency ( F 0) during vowel production in the aforementioned protocols was also measured. The order of sustained vowel versus syllable production tasks and the target vowels were counterbalanced across subjects. Results: Analysis of MAF in comfortable sustained phonation showed a significant main effect of vowel type (small effect size), with post hoc analysis indicating that the MAF observed for /i/ was significantly lower than that observed for /α/ (0.139 vs. 0.152 L/s, respectively). MAF for the vowel /u/ fell in between (0.147 L/s), with differences in MAF between /i/ versus /u/ and /α/ versus /u/ being nonsignificant. In contrast, the analysis of MAF in syllable context showed no significant main effect of vowel. The main effect of vowel was significant for measures of Psub obtained in the syllable context (small effect size), with syllables including the high-impedance vowel /i/ observed to have significantly higher Psub compared with syllables including the low-impedance vowel /α/ (7.96 vs. 7.54 cm H 2 O, respectively). Mean Psub for the syllables including /u/ was again observed to fall in between (7.64 cm H 2 O), with differences in Psub between /i/ versus /u/ and /α/ versus /u/ being nonsignificant. Measures of MAF and Psub from different vowel contexts were highly correlated. Vocal F 0 was not observed to be a significant predictor of MAF or Psub. Conclusions: Although the generally small effect sizes for the effect of vowel type on aerodynamic measures indicate that this finding may be of little practical significance, the results of this study support the view that vowel type has a predictable and measurable effect on measures of MAF (in comfortable sustained phonation) and Psub in syllable context. Supraglottal impedance changes secondary to articulatory differences between vowels are primarily responsible for the differences between vowels on MAF and Psub versus F 0-related changes in laryngeal activity that may accompany different vowel productions. The results of this study indicate that vowel type should not have any substantial effect on normative expectations for MAF or Psub, and linear regression equations may be used to convert aerodynamic measures of MAF and Psub between different vowels with relatively little error.
- 13 October 2026
- Published by Elsevier in Journal of Voice
Clinical Utility of Aerodynamic Measures in Vocal Fold Augmentation Outcomes
- 13 October 2026
- Published by Elsevier in Journal of Voice
Clinical Utility of Aerodynamic Measures in Vocal Fold Augmentation Outcomes
- 11 August 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (8) , 3679-3689
Validity of the Cepstral Spectral Index of Dysphonia in the Persian Language in Sustained Vowel, Sentence, and All-Voiced Sentence Contexts
Purpose: Cepstral Spectral Index of Dysphonia (CSID) characterizes and objectively quantifies characteristics of voice quality. The findings of CSID's impact in determining dysphonia characteristics in different languages, however, are unclear but important if this tool is to be used cross-linguistically. Therefore, the purpose of the study was to determine the validity of CSID in Persian speakers. Method: Persian-speaking participants were assigned to two groups: patients with voice disorders ( n = 102) and vocally healthy speakers ( n = 38). They produced a sustained vowel /ɑ/ and a Persian connected speech sample representing a sentence with a majority of voiced sounds. Three speech-language pathologists conducted auditory-perceptual ratings on a 4-point ordinal scale ( vocally healthy , mild , moderate , or severe ). Acoustic analysis was conducted using the Analysis of Dysphonia in Speech and Voice software. CSID values in addition to cepstral peak prominence (CPP), CPP standard deviation, low-to-high (L/H) spectral ratio, and L/H spectral ratio standard deviation were extracted from (a) a 1-s segment of the middle part of the sustained vowel, (b) the onset to offset of the connected speech sample, and (c) the same sentence further trimmed to contain only voiced parts by omitting voiceless sections. Results: The area under the curve (AUC) values for the three tasks were as follows: sustained vowel, AUC = 0.978; connected speech sentence, AUC = 0.961; and all-voiced connected speech sentence, AUC = 0.957. The cutoff points of 4.88 (a sensitivity of 92.2% and a specificity of 94.7%), −4.14 (a sensitivity of 91.2% and a specificity of 92.1%), and 6.76 (a sensitivity of 83.3% and a specificity of 97.4%) yielded the highest level of diagnostic findings for CSID in sustained vowel, connected speech sentence, and all-voiced connected speech sentence, respectively. In addition, significant and strong correlations were found between the CSID values and dysphonia category in the sustained vowel ( r = .815, p < .001), connected speech sentence ( r = .841, p < .001), and all-voiced connected speech sentence ( r = .833, p < .001). Conclusion: The findings of this study showed that CSID is a valid acoustics-based index with the potential to assist clinicians in achieving a more complete characterization and quantification of dysphonia in Persian-speaking clients during voice assessments.
- 11 August 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (8) , 3679-3689
Validity of the Cepstral Spectral Index of Dysphonia in the Persian Language in Sustained Vowel, Sentence, and All-Voiced Sentence Contexts
Purpose: Cepstral Spectral Index of Dysphonia (CSID) characterizes and objectively quantifies characteristics of voice quality. The findings of CSID's impact in determining dysphonia characteristics in different languages, however, are unclear but important if this tool is to be used cross-linguistically. Therefore, the purpose of the study was to determine the validity of CSID in Persian speakers. Method: Persian-speaking participants were assigned to two groups: patients with voice disorders ( n = 102) and vocally healthy speakers ( n = 38). They produced a sustained vowel /ɑ/ and a Persian connected speech sample representing a sentence with a majority of voiced sounds. Three speech-language pathologists conducted auditory-perceptual ratings on a 4-point ordinal scale ( vocally healthy , mild , moderate , or severe ). Acoustic analysis was conducted using the Analysis of Dysphonia in Speech and Voice software. CSID values in addition to cepstral peak prominence (CPP), CPP standard deviation, low-to-high (L/H) spectral ratio, and L/H spectral ratio standard deviation were extracted from (a) a 1-s segment of the middle part of the sustained vowel, (b) the onset to offset of the connected speech sample, and (c) the same sentence further trimmed to contain only voiced parts by omitting voiceless sections. Results: The area under the curve (AUC) values for the three tasks were as follows: sustained vowel, AUC = 0.978; connected speech sentence, AUC = 0.961; and all-voiced connected speech sentence, AUC = 0.957. The cutoff points of 4.88 (a sensitivity of 92.2% and a specificity of 94.7%), −4.14 (a sensitivity of 91.2% and a specificity of 92.1%), and 6.76 (a sensitivity of 83.3% and a specificity of 97.4%) yielded the highest level of diagnostic findings for CSID in sustained vowel, connected speech sentence, and all-voiced connected speech sentence, respectively. In addition, significant and strong correlations were found between the CSID values and dysphonia category in the sustained vowel ( r = .815, p < .001), connected speech sentence ( r = .841, p < .001), and all-voiced connected speech sentence ( r = .833, p < .001). Conclusion: The findings of this study showed that CSID is a valid acoustics-based index with the potential to assist clinicians in achieving a more complete characterization and quantification of dysphonia in Persian-speaking clients during voice assessments.
- 12 February 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (2) , 526-540
Validation of Novel Clinical Scales for Perceptual Evaluation of Vocal Breathiness and Roughness
Objective: Perceived voice quality (VQ) ratings provide data with ordinal characteristics on arbitrary scales regarding the relative order of VQ disruptions ranging from mild to severe quality. The overarching goal of this research is to develop a new and rigorous method for perceptual evaluation of VQ using quantitative comparisons and facilitating standardized comparisons across time points, clinicians, and clinical sites. Our prior research developed standard ratio-level scales of breathy and rough VQ analogous to the sone scale that (a) have physical units, (b) are strongly related to psychophysical measures, and (c) can quantify not just the direction but also the magnitude of change. The current study reestablishes the standard reference points, validates the newly developed VQ scales with natural dysphonic stimuli, and evaluates the psychometric measurement properties of the novel scales for breathiness and roughness in a small clinical pilot experiment. Method: In the first experiment, a set of magnitude estimation (ME) tasks were first used to determine the perceived magnitudes of breathiness and roughness of 10 natural voice stimuli in each VQ continuum. The resulting data were compared with previously acquired magnitude estimates of the synthetic comparison stimuli to adjust the reference points. In the second experiment, a set of inexperienced listeners evaluated the same set of natural dysphonic stimuli using the new clinical scales with perceived magnitude expressed in standard VQ units. In the third experiment, two expert clinicians evaluated 12 breathy and 10 rough dysphonic voices (pre- and posttreatment) using the new VQ scales. Results: The standard reference units were identified as 15 dB SNR for breathiness and −26 dB modulation depth for roughness. The strength of the relationship between the ME data and the predicted values from the clinical scales was high for both breathiness and roughness ( r > .9). Treatment outcomes measured using the newly developed scales demonstrated high intra- ( r > .8) and interrater reliability ( r > .8) when compared to Consensus Auditory-Perceptual Evaluation of Voice providing evidence for concurrent validity of the clinical scales. Conclusion: Such formal VQ scales support valid quantitative comparisons of perceptual judgments and represent a critical step in clinical translation.
- 12 February 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (2) , 526-540
Validation of Novel Clinical Scales for Perceptual Evaluation of Vocal Breathiness and Roughness
Objective: Perceived voice quality (VQ) ratings provide data with ordinal characteristics on arbitrary scales regarding the relative order of VQ disruptions ranging from mild to severe quality. The overarching goal of this research is to develop a new and rigorous method for perceptual evaluation of VQ using quantitative comparisons and facilitating standardized comparisons across time points, clinicians, and clinical sites. Our prior research developed standard ratio-level scales of breathy and rough VQ analogous to the sone scale that (a) have physical units, (b) are strongly related to psychophysical measures, and (c) can quantify not just the direction but also the magnitude of change. The current study reestablishes the standard reference points, validates the newly developed VQ scales with natural dysphonic stimuli, and evaluates the psychometric measurement properties of the novel scales for breathiness and roughness in a small clinical pilot experiment. Method: In the first experiment, a set of magnitude estimation (ME) tasks were first used to determine the perceived magnitudes of breathiness and roughness of 10 natural voice stimuli in each VQ continuum. The resulting data were compared with previously acquired magnitude estimates of the synthetic comparison stimuli to adjust the reference points. In the second experiment, a set of inexperienced listeners evaluated the same set of natural dysphonic stimuli using the new clinical scales with perceived magnitude expressed in standard VQ units. In the third experiment, two expert clinicians evaluated 12 breathy and 10 rough dysphonic voices (pre- and posttreatment) using the new VQ scales. Results: The standard reference units were identified as 15 dB SNR for breathiness and −26 dB modulation depth for roughness. The strength of the relationship between the ME data and the predicted values from the clinical scales was high for both breathiness and roughness ( r > .9). Treatment outcomes measured using the newly developed scales demonstrated high intra- ( r > .8) and interrater reliability ( r > .8) when compared to Consensus Auditory-Perceptual Evaluation of Voice providing evidence for concurrent validity of the clinical scales. Conclusion: Such formal VQ scales support valid quantitative comparisons of perceptual judgments and represent a critical step in clinical translation.
- 20 November 2025
- Published by Elsevier in Journal of Voice
Application of Pitch-Based Measures for Aperiodic Pediatric Dysphonic Voices
- 20 November 2025
- Published by Elsevier in Journal of Voice
Application of Pitch-Based Measures for Aperiodic Pediatric Dysphonic Voices
- 6 November 2025
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 34 (6) , 3531-3548
The Accuracy of Smartphone Recordings for Clinical Voice Diagnostics in Acoustic Voice Quality Assessments: A Systematic Review and Meta-Analysis
Objective: Clinical voice quality assessments typically use external microphones meeting technical standards for instrumental assessment of voice. As smartphones advance, this study aimed to determine their suitability for voice recordings through a systematic review with meta-analysis. Method: Three database searches were conducted, ranging from their inception to December 2024, as well as a manual search. Cross-sectional studies were included on widely used clinical acoustic voice quality measures of the software Praat (i.e., jitter, shimmer, harmonics-to-noise ratio [HNR], smoothed cepstral peak prominence [CPPS], and acoustic voice quality index [AVQI]). Results: We found 10 eligible research studies with a total of 379 participants who were simultaneously compared between a clinical recording system (CRS) and different smartphones by Apple and Samsung products. All included studies focused on individuals with vocally healthy voices, while four of the studies also included those with voice disorders. In comparison with CRS, iPhones revealed significant differences and large effect sizes in HNR (mean difference of 2.20, 95% CI [0.59, 3.82], p = .008, Cohen's d = 2.54) and in AVQI (mean difference of −0.53, 95% CI [−1.00, −0.06], p = .027, Cohen's d = −1.99), but in the direct comparison between Apple and Samsung mobile device recordings, significant differences and large effect sizes were found in jitter (mean difference of −0.17, 95% CI −0.27, −0.08, p < .001, Cohen's d = −1.18) and CPPS (mean difference of 0.87, 95% CI [0.20, 1.53], p = .011, Cohen's d = 1.26). Recordings with Samsung products showed only significant differences and a large effect size with CRS in jitter (mean difference of −0.16, 95% CI [−0.29, −0.03], p = .019, Cohen's d = −0.84). Conclusions: The present meta-analysis indicated some inconsistency in the outcomes of acoustic voice quality parameters between smartphone recordings and CRS. While acoustic measurements are frequently used in clinical voice assessments and smartphones are widely available, it is important to note that for certain parameters, current smartphone recordings may not yet match the precision of CRSs for voice quality analyses. Supplemental Material: https://doi.org/10.23641/asha.30200029
- 6 November 2025
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 34 (6) , 3531-3548
The Accuracy of Smartphone Recordings for Clinical Voice Diagnostics in Acoustic Voice Quality Assessments: A Systematic Review and Meta-Analysis
Objective: Clinical voice quality assessments typically use external microphones meeting technical standards for instrumental assessment of voice. As smartphones advance, this study aimed to determine their suitability for voice recordings through a systematic review with meta-analysis. Method: Three database searches were conducted, ranging from their inception to December 2024, as well as a manual search. Cross-sectional studies were included on widely used clinical acoustic voice quality measures of the software Praat (i.e., jitter, shimmer, harmonics-to-noise ratio [HNR], smoothed cepstral peak prominence [CPPS], and acoustic voice quality index [AVQI]). Results: We found 10 eligible research studies with a total of 379 participants who were simultaneously compared between a clinical recording system (CRS) and different smartphones by Apple and Samsung products. All included studies focused on individuals with vocally healthy voices, while four of the studies also included those with voice disorders. In comparison with CRS, iPhones revealed significant differences and large effect sizes in HNR (mean difference of 2.20, 95% CI [0.59, 3.82], p = .008, Cohen's d = 2.54) and in AVQI (mean difference of −0.53, 95% CI [−1.00, −0.06], p = .027, Cohen's d = −1.99), but in the direct comparison between Apple and Samsung mobile device recordings, significant differences and large effect sizes were found in jitter (mean difference of −0.17, 95% CI −0.27, −0.08, p < .001, Cohen's d = −1.18) and CPPS (mean difference of 0.87, 95% CI [0.20, 1.53], p = .011, Cohen's d = 1.26). Recordings with Samsung products showed only significant differences and a large effect size with CRS in jitter (mean difference of −0.16, 95% CI [−0.29, −0.03], p = .019, Cohen's d = −0.84). Conclusions: The present meta-analysis indicated some inconsistency in the outcomes of acoustic voice quality parameters between smartphone recordings and CRS. While acoustic measurements are frequently used in clinical voice assessments and smartphones are widely available, it is important to note that for certain parameters, current smartphone recordings may not yet match the precision of CRSs for voice quality analyses. Supplemental Material: https://doi.org/10.23641/asha.30200029
- 28 August 2025
- Published by Elsevier in Journal of Voice
Using a Vortex Whistle System to Estimate Phonatory Airflow via the Phonation Quotient
- 28 August 2025
- Published by Elsevier in Journal of Voice
Using a Vortex Whistle System to Estimate Phonatory Airflow via the Phonation Quotient