JMJunki Maehara

Junki Maehara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junki Maehara has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of “visible in retrospect” to monitor false-negative findings in radiological reports

    by Tomoyuki Noguchi, Koji Yamashita, Shuji Matsuura, Ryotaro Kamei, Junki Maehara, Kiyomi Furuya, Shino Harada, Saki Adachi, Yasushi Okada

    Purpose: False-negative findings in radiological reports can lead to serious adverse patient outcomes. We determined the frequency and tendency of false-negative findings in radiological reports by searching for words related to “visible in retrospect”. Methods: In the period of 34 months, we extracted radiological reports containing words related to “visible in retrospect”. Of these reports, we extracted false-negative findings that were not described in past reports and were first detected retrospectively. Misinterpretations were excluded. The occurrences of the terms that we identified were analyzed by all examinations, modality, month, and anatomical and lesion classifications were analyzed. Results: Of the 135,251 examinations, 941 reports (0.71%) with 962 findings were detected, with an average of 1.4 findings per business day. By modality, 713 of 81,899 (0.87%) CT examinations, 208 of 36,174 (0.57%) MR, 34 of 9,585 (0.35%) FDG-PET-CT, 2 of 2,258 (0.09%) digital radiography, and 5 of 5,335 (0.09%) other nuclear medicine examinations were found. By anatomical classification, there were 383 (40%) in chest, 353 (37%) in abdomen, 162 (17%) in head, 42 (4.4%) in face and neck, 9 (0.93%) in extremity, and 13 (1.4%) in others. By lesion classification, we identified 665 (69%) for localized lesion, 170 (18%) for vascular lesion, 83 (8.6%) for inflammatory lesion, 14 (1.5%) for traumatic lesion, 12 (1.2%) for organ dysfunction, 11 (1.1%) for degenerative lesion, and 7 (0.7%) for the others. Notable high-frequency specific site diseases by modality were 210 (22%) of localized lesions in lung on CT. Conclusion: Our results demonstrated that missed lung localized lesions on CT, which account for about a fifth of false-negative findings, were the most common false-negative finding.


  • Open Access

    Current status and challenges of percutaneous vertebroplasty (PVP)

    by Tomoyuki Noguchi, Koji Yamashita, Ryotaro Kamei, Junki Maehara

    A narrative review regarding percutaneous vertebroplasty (PVP) for osteoporotic vertebral fracture (OVF) is provided herein, addressing the epidemic of OVF in Japan, the latest response to the criticism of PVP for OVFs, the indications and potential risks of PVP for OVFs, and a future perspective for PVP. Each year in Japan, approximately 32,000 patients aged 55 years or older suffer from chronic low back pain for several months to several years due to a compression fracture. PVP is one of the surgical treatments for an OVF, and it is less invasive compared to the traditional open surgery. PVP is suitable for OVF patients who have difficulty walking as assessed by the modified Yokoyama’s activities of daily living (ADL) scoring system, and for patients with Kummell's disease diagnosed by CT and MRI examinations. Serious adverse events related to PVP occur in 1.1–3.3% of the cases, but direct deaths from PVP are extremely rare at less than 1%. Recent studies demonstrated that OVF patients treated with PVP are less likely to die after the treatment than non-surgically treated patients, which conflicts with the Cochran reviews’ conclusion not supporting PVP for OVFs. Novel robotic systems and procedure-support devices are being developed, providing a next step toward fully automated PVP procedures.


  • Open Access

    Accuracy of vertebral puncture in percutaneous vertebroplasty

    by Tomoyuki Noguchi, Koji Yamashita, Yoshitaka Shida, Takashi Okafuji, Ryotaro Kamei, Junki Maehara, Tsuyoshi Tajima

    Purpose: To clarify the accuracy of vertebral puncture of the vertebral tertile area needling (VETERAN) method puncturing the pedicle superimposed on one-third of the width between the lateral vertebral line to the contralateral medial lamina line compared with Cathelin-needle-assisted puncture (CAP) method puncturing using the Cathelin needle as a guide in percutaneous vertebroplasty. Materials and methods: 449 punctures by CAP method and 125 punctures by VETERAN method were enrolled. We compared the puncture accuracy of both methods. We estimated a vertebral estimated tilting ratio (VET-ratio) defined as ratio of the distance between the lateral vertebral line and the contralateral medial laminal line to the distance between the vertebral lateral line and the puncture point measured by computed tomography. We also estimated the procedural items and clinical outcomes. Results: VETERAN method with 100% of punctures within safe zone (cortical breaches within 2 mm) had significantly higher accuracy than CAP method with 97.8% (p < 0.01) for the 2 mm incremental evaluation. No cases with a VET-ratio of 36% or less had cortical breaches. VETERAN method had shorter operative time per puncture (p < 0.01) and exposure time per puncture (p < 0.05). Conclusion: VETERAN method reduced the occurrence of the inaccurate puncture, operative times, and exposure times. A VET-ratio with 36% or less is associated with a safe puncture using VETERAN method.