Ryota Takai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryota Takai has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Takashi Nogami
High Energy Accelerator Research Organization (KEK)
3 shared publications- Takashi Obina
Accelerator Laboratory, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
3 shared publications - Hiroshi Sakai
High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
2 shared publications - Masahiro Yamamoto
High Energy Accelerator Research Organization (KEK)
2 shared publications - Miho Shimada
High Energy Accelerator Research Organization (KEK)
2 shared publications - Norio Nakamura
High Energy Accelerator Research Organization (KEK)
2 shared publications
Latest Publications
- Open Access
- 26 September 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (9)
Stable operation of a fully energy-recovered 1-mA-class electron beam at a compact energy-recovery linac
A compact energy-recovery linac (cERL) has been under development at KEK to drive key accelerator technologies, demonstrate energy recovery under various conditions, and support beam applications. cERL began beam operations in 2013 to create stable, low-emittance, energy-recovered beams. The project focused on gradually increasing the current transported in a stepwise fashion while maintaining low beam losses at each step. However, the energy recovery of high-current beams is an issue that needs to be addressed. In this study, we propose a method for high-current beam tuning of approximately 1 mA under energy-recovery conditions with extremely small beam loss. We prepared a collimator and a local fast beam loss monitor to reduce the beam loss. We report successful results at approximately 1 mA, demonstrating 100.0% energy recovery with extremely small beam loss. The radiofrequency (rf) amplitude and phase varied by less than 0.02% and 0.02°, respectively. The study findings are expected to provide insights into steady beam operation for high-brightness beams and high-efficiency energy-recovery operations required for future extreme ultraviolet free-electron lasers.
- 26 September 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (9)
Open AccessStable operation of a fully energy-recovered 1-mA-class electron beam at a compact energy-recovery linac
A compact energy-recovery linac (cERL) has been under development at KEK to drive key accelerator technologies, demonstrate energy recovery under various conditions, and support beam applications. cERL began beam operations in 2013 to create stable, low-emittance, energy-recovered beams. The project focused on gradually increasing the current transported in a stepwise fashion while maintaining low beam losses at each step. However, the energy recovery of high-current beams is an issue that needs to be addressed. In this study, we propose a method for high-current beam tuning of approximately 1 mA under energy-recovery conditions with extremely small beam loss. We prepared a collimator and a local fast beam loss monitor to reduce the beam loss. We report successful results at approximately 1 mA, demonstrating 100.0% energy recovery with extremely small beam loss. The radiofrequency (rf) amplitude and phase varied by less than 0.02% and 0.02°, respectively. The study findings are expected to provide insights into steady beam operation for high-brightness beams and high-efficiency energy-recovery operations required for future extreme ultraviolet free-electron lasers.
- Open Access
- 29 November 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (11) , 112401
Suppression of eddy-current effects in beam injection using a pulsed sextupole magnet with a new ceramic chamber
At the Photon Factory storage ring (PF ring) of the High Energy Accelerator Research Organization (KEK), a pulsed sextupole magnet (PSM) has been used for top-up injection for the first time. Following its successful operation at the KEK, this new injection scheme was expanded to one with a nonlinear kicker in BESSY II and was then applied at UVSOR and Aichi SR in Japan. Also, the PSM system in the PF ring was improved by introducing a rectangular shape for the magnet’s bore to strengthen the magnetic field. However, this upgraded PSM was not implemented for user operation because it induced a horizontal oscillation of the stored beam with a maximum amplitude of 5.0 mm. This oscillation was assumed to be caused by eddy currents originating from the uniform inner coating of the ceramic chamber. We, therefore, developed a modified ceramic chamber with a new patterned coating designed to suppress the eddy current–induced magnetic field. The pattern shape was optimized to suppress this magnetic field and, simultaneously, to reduce the resistive wall impedance. A fine-line pattern-coating process, originally developed for a ceramic chamber with an integrated pulsed magnet, was modified for application with the magnet’s chamber of the sextupole. The maximum horizontal oscillation amplitude was suppressed by a factor of 16 by using the new PSM chamber without any issues related to beam instability. Details of the historical background of the upgrading of the PSM system, an investigation of the cause of the abnormal oscillation problem, the development of the new process for coating the ceramic chamber, and the results of the beam-response measurements for the new ceramic chamber installed in the PF ring are reported in this article.
- 29 November 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (11) , 112401
Open AccessSuppression of eddy-current effects in beam injection using a pulsed sextupole magnet with a new ceramic chamber
At the Photon Factory storage ring (PF ring) of the High Energy Accelerator Research Organization (KEK), a pulsed sextupole magnet (PSM) has been used for top-up injection for the first time. Following its successful operation at the KEK, this new injection scheme was expanded to one with a nonlinear kicker in BESSY II and was then applied at UVSOR and Aichi SR in Japan. Also, the PSM system in the PF ring was improved by introducing a rectangular shape for the magnet’s bore to strengthen the magnetic field. However, this upgraded PSM was not implemented for user operation because it induced a horizontal oscillation of the stored beam with a maximum amplitude of 5.0 mm. This oscillation was assumed to be caused by eddy currents originating from the uniform inner coating of the ceramic chamber. We, therefore, developed a modified ceramic chamber with a new patterned coating designed to suppress the eddy current–induced magnetic field. The pattern shape was optimized to suppress this magnetic field and, simultaneously, to reduce the resistive wall impedance. A fine-line pattern-coating process, originally developed for a ceramic chamber with an integrated pulsed magnet, was modified for application with the magnet’s chamber of the sextupole. The maximum horizontal oscillation amplitude was suppressed by a factor of 16 by using the new PSM chamber without any issues related to beam instability. Details of the historical background of the upgrading of the PSM system, an investigation of the cause of the abnormal oscillation problem, the development of the new process for coating the ceramic chamber, and the results of the beam-response measurements for the new ceramic chamber installed in the PF ring are reported in this article.
- Open Access
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113101
Construction and commissioning of mid-infrared self-amplified spontaneous emission free-electron laser at compact energy recovery linac
The mid-infrared range is an important spectrum range where materials exhibit a characteristic response corresponding to their molecular structure. A free-electron laser (FEL) is a promising candidate for a high-power light source with wavelength tunability to investigate the nonlinear response of materials. Although the self-amplification spontaneous emission (SASE) scheme is not usually adopted in the mid-infrared wavelength range, it may have advantages such as layout simplicity, the possibility of producing a single pulse, and scalability to a short-wavelength facility. To demonstrate the operation of a mid-infrared SASE FEL system in an energy recovery linac (ERL) layout, we constructed an SASE FEL setup in cERL, a test facility of the superconducting linac with the ERL configuration. Despite the adverse circumstance of space charge effects due to the given boundary condition of the facility, we successfully established the beam condition at the undulators and observed FEL emission at a wavelength of 20 μm. The results show that the layout of cERL has the potential for serving as a mid-infrared light source.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113101
Open AccessConstruction and commissioning of mid-infrared self-amplified spontaneous emission free-electron laser at compact energy recovery linac
The mid-infrared range is an important spectrum range where materials exhibit a characteristic response corresponding to their molecular structure. A free-electron laser (FEL) is a promising candidate for a high-power light source with wavelength tunability to investigate the nonlinear response of materials. Although the self-amplification spontaneous emission (SASE) scheme is not usually adopted in the mid-infrared wavelength range, it may have advantages such as layout simplicity, the possibility of producing a single pulse, and scalability to a short-wavelength facility. To demonstrate the operation of a mid-infrared SASE FEL system in an energy recovery linac (ERL) layout, we constructed an SASE FEL setup in cERL, a test facility of the superconducting linac with the ERL configuration. Despite the adverse circumstance of space charge effects due to the given boundary condition of the facility, we successfully established the beam condition at the undulators and observed FEL emission at a wavelength of 20 μm. The results show that the layout of cERL has the potential for serving as a mid-infrared light source.