Hadi Farzan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hadi Farzan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Aghil Iranmanesh
Department of Mechanical Engineering, University of Jiroft, Jiroft, Iran
3 shared publications M. Mahmoudi
Department of Mechanical Engineering, Higher Education Complex of Bam, Bam, Iran
3 shared publicationsMojtaba Mahmoudi
3 shared publicationsE. Hasan Zaim
Mechanical Engineering Department, Sirjan University of Technology, 78137-33385, Sirjan, Iran
2 shared publicationsEhsan Hasan Zaim
2 shared publicationsM. Ameri
Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (12) , 3154-3169
Performance Enhancement of a Concentrated Photovoltaic-Thermal System Integrated with Active Thermoelectric Cooling: A Comparative Experimental Study
Concentrated photovoltaic/thermal (CPV/T) systems face a critical challenge: thermal degradation that reduces electrical output. This paper introduces and experimentally validates a novel hybrid thermal management strategy that integrates a CPV/T collector with thermoelectric coolers paired with finned heat sinks (TEC/FHSs). This setup enables active cooling to maintain low PV cell temperatures, thereby boosting electrical output, while simultaneously recovering residual heat via forced convection for thermal energy utilization. A comparative analysis was performed using First Law (energy) and Second Law (exergy) metrics across operations with and without the TEC/FHSs. The active cooling strategy proved highly effective: the CPV/T with TEC/FHSs system successfully reduced the PV cell temperature by up to 6 °C at peak intensity. Quantitatively, this mitigation led to a daily electrical efficiency of 10.8%, marking an improvement of 30.8% over the mode without TEC/FHSs. Although the daily thermal efficiency was marginally lower with TEC/FHSs (e.g., 20.67% vs. 25%), the system still showed a 27.3% improvement in overall exergy efficiency. This conclusive finding confirms that the thermodynamic quality gained from the enhanced electrical output successfully offsets the TEC/FHSs’ power consumption and the slight thermal losses. Therefore, integrating TEC/FHSs is an effective and thermodynamically advantageous solution for thermal management in CPV/Ts.
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (12) , 3154-3169
Open AccessPerformance Enhancement of a Concentrated Photovoltaic-Thermal System Integrated with Active Thermoelectric Cooling: A Comparative Experimental Study
Concentrated photovoltaic/thermal (CPV/T) systems face a critical challenge: thermal degradation that reduces electrical output. This paper introduces and experimentally validates a novel hybrid thermal management strategy that integrates a CPV/T collector with thermoelectric coolers paired with finned heat sinks (TEC/FHSs). This setup enables active cooling to maintain low PV cell temperatures, thereby boosting electrical output, while simultaneously recovering residual heat via forced convection for thermal energy utilization. A comparative analysis was performed using First Law (energy) and Second Law (exergy) metrics across operations with and without the TEC/FHSs. The active cooling strategy proved highly effective: the CPV/T with TEC/FHSs system successfully reduced the PV cell temperature by up to 6 °C at peak intensity. Quantitatively, this mitigation led to a daily electrical efficiency of 10.8%, marking an improvement of 30.8% over the mode without TEC/FHSs. Although the daily thermal efficiency was marginally lower with TEC/FHSs (e.g., 20.67% vs. 25%), the system still showed a 27.3% improvement in overall exergy efficiency. This conclusive finding confirms that the thermodynamic quality gained from the enhanced electrical output successfully offsets the TEC/FHSs’ power consumption and the slight thermal losses. Therefore, integrating TEC/FHSs is an effective and thermodynamically advantageous solution for thermal management in CPV/Ts.
- Open Access
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (4) , 925-935
Comparative Study on Electrical Performance of Photovoltaic Panels Integrated with Thermoelectric Coolers and Finned Heat Sinks: An Experimental Study
The photovoltaic (PV) panels’ efficiency is reduced by increasing their temperature; hence, various cooling methods have been developed to handle this problem and cool PVs. Fins are simple, affordable, and strong methods employed in many heat transfer problems to fasten the heat dissipation rate. New cooling methods, such as thermoelectric coolers (TECs), have recently gained tremendous attention. The current study used an experimental approach to carry out a fair comparison between finned heat sinks (FHSs) and TECs. Three scenarios were considered and tested outdoors: uncooled PV, PV/FHSs, and PV/TECs. The obtained data revealed that the cooling methods used could effectively reduce the PV temperature. The PV temperatures at noon were 48 °C, 45 °C, and 44 °C in the uncooled PV, PV/FHSs, and PV/TECs, respectively. Hence, the cooler the PV panel, the higher the electrical power generated and the efficiency. The electrical power peaked at 2.5 W, 5.78 W, and 5.68 W in the uncooled PV, PV/FHSs, and PV/TECs; furthermore, the daily electrical efficiency reached 4.34%, 10.07%, and 9.77% in the uncooled PV, PV/FHSs, and PV/TECs, respectively. However, the TECs had a higher cooling performance than the FHSs, but the TECs consumed electrical power, affecting their performance. Hence, the PV/FHSs had slightly higher electrical efficiency than the PV/TECs. It can be concluded that FHSs and TECs are effective cooling methods, but TECs are highly costly. Therefore, FHSs are a favorable, affordable method to improve efficiency.
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (4) , 925-935
Open AccessComparative Study on Electrical Performance of Photovoltaic Panels Integrated with Thermoelectric Coolers and Finned Heat Sinks: An Experimental Study
The photovoltaic (PV) panels’ efficiency is reduced by increasing their temperature; hence, various cooling methods have been developed to handle this problem and cool PVs. Fins are simple, affordable, and strong methods employed in many heat transfer problems to fasten the heat dissipation rate. New cooling methods, such as thermoelectric coolers (TECs), have recently gained tremendous attention. The current study used an experimental approach to carry out a fair comparison between finned heat sinks (FHSs) and TECs. Three scenarios were considered and tested outdoors: uncooled PV, PV/FHSs, and PV/TECs. The obtained data revealed that the cooling methods used could effectively reduce the PV temperature. The PV temperatures at noon were 48 °C, 45 °C, and 44 °C in the uncooled PV, PV/FHSs, and PV/TECs, respectively. Hence, the cooler the PV panel, the higher the electrical power generated and the efficiency. The electrical power peaked at 2.5 W, 5.78 W, and 5.68 W in the uncooled PV, PV/FHSs, and PV/TECs; furthermore, the daily electrical efficiency reached 4.34%, 10.07%, and 9.77% in the uncooled PV, PV/FHSs, and PV/TECs, respectively. However, the TECs had a higher cooling performance than the FHSs, but the TECs consumed electrical power, affecting their performance. Hence, the PV/FHSs had slightly higher electrical efficiency than the PV/TECs. It can be concluded that FHSs and TECs are effective cooling methods, but TECs are highly costly. Therefore, FHSs are a favorable, affordable method to improve efficiency.
- Open Access
- 1 July 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (03) , 447-455
Improve Efficiency of Photovoltaic/Thermal Systems using Porous Materials: An Experimental Study
The weak convection mechanism in photovoltaic/thermal (PV/T) systems leads to numerous studies dealing with this problem. This study analyzes a new, affordable method to improve convection in PV/Ts and increase their thermal/electrical efficiency. The use of metallic porous materials with high thermal conductivity is a robust approach to increase the efficiency of PV/Ts by accelerating the cooling rate of PVs. In this study, the robust method is experimentally investigated, and the effectiveness of using porous materials to improve the efficiency of PV/Ts is evaluated. For this purpose, an experimental setup was fabricated, and two scenarios were investigated: a non-porous PV/T and a porous one in which steel wool was used as a porous material. The acquired results revealed that using steel wool reduces the PV temperature by 9.9 oC and increases the outlet temperature by 4.41 oC at the air flow rate of 0.17 kg/s. Lowering the PV temperature increases the electrical power generated while the electrical efficiency improves by nearly 11.18%. The higher outlet temperature causes a higher thermal efficiency; hence, using porous materials increases the thermal efficiency by 50.7%. In conclusion, using porous materials is a robust, affordable approach to improve the thermal/electrical efficiency of PV/Ts.
- 1 July 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (03) , 447-455
Open AccessImprove Efficiency of Photovoltaic/Thermal Systems using Porous Materials: An Experimental Study
The weak convection mechanism in photovoltaic/thermal (PV/T) systems leads to numerous studies dealing with this problem. This study analyzes a new, affordable method to improve convection in PV/Ts and increase their thermal/electrical efficiency. The use of metallic porous materials with high thermal conductivity is a robust approach to increase the efficiency of PV/Ts by accelerating the cooling rate of PVs. In this study, the robust method is experimentally investigated, and the effectiveness of using porous materials to improve the efficiency of PV/Ts is evaluated. For this purpose, an experimental setup was fabricated, and two scenarios were investigated: a non-porous PV/T and a porous one in which steel wool was used as a porous material. The acquired results revealed that using steel wool reduces the PV temperature by 9.9 oC and increases the outlet temperature by 4.41 oC at the air flow rate of 0.17 kg/s. Lowering the PV temperature increases the electrical power generated while the electrical efficiency improves by nearly 11.18%. The higher outlet temperature causes a higher thermal efficiency; hence, using porous materials increases the thermal efficiency by 50.7%. In conclusion, using porous materials is a robust, affordable approach to improve the thermal/electrical efficiency of PV/Ts.
- Open Access
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (4) , 570-579
Experimental Study on a Novel Passive Method to Improve Performance of Photovoltaic Systems using Encapsulated Phase Change Materials
Since photovoltaic (PV) panels are exposed to solar intensity long during the daytime, their temperature increases significantly, which reduces their electrical efficiencies. This crucial factor has led many studies to investigate various methods of cooling PV. The current study experimentally analyzes the effectiveness of a new passive method to reduce PVs’ temperature by using encapsulated phase change material (PCM) units placed on the PVs’ backsides. PCMs have high latent heat and absorb/release huge amounts of thermal energy through melting/solidification. Recent studies covered the PVs’ backside with PCM, while the current study used PCM capsules instead. This new strategy lets the PV exchange heat the ambient when PCM melt completely and improves cooling performance. An experimental setup was developed for this aim, and it was tested outdoors in Bam, Iran, in late April and early May 2024, considering two scenarios: PV with and without encapsulated PCM. The results proved that PCM units reduced the PV temperature between 3 oC and 9 oC. This temperature reduction caused the PV with PCM capsules to produce more electrical power by 17% compared to the conventional PV at noon. The higher the electrical power generated, the higher the efficiency can be achieved in the scenario with PCM units. The daily electrical efficiency of the PV with PCM units was 14.14% higher than the conventional PV. This study illustrates that using encapsulated PCM units as a passive method is a strong and affordable method to improve the PVs’ electrical efficiency.
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (4) , 570-579
Open AccessExperimental Study on a Novel Passive Method to Improve Performance of Photovoltaic Systems using Encapsulated Phase Change Materials
Since photovoltaic (PV) panels are exposed to solar intensity long during the daytime, their temperature increases significantly, which reduces their electrical efficiencies. This crucial factor has led many studies to investigate various methods of cooling PV. The current study experimentally analyzes the effectiveness of a new passive method to reduce PVs’ temperature by using encapsulated phase change material (PCM) units placed on the PVs’ backsides. PCMs have high latent heat and absorb/release huge amounts of thermal energy through melting/solidification. Recent studies covered the PVs’ backside with PCM, while the current study used PCM capsules instead. This new strategy lets the PV exchange heat the ambient when PCM melt completely and improves cooling performance. An experimental setup was developed for this aim, and it was tested outdoors in Bam, Iran, in late April and early May 2024, considering two scenarios: PV with and without encapsulated PCM. The results proved that PCM units reduced the PV temperature between 3 oC and 9 oC. This temperature reduction caused the PV with PCM capsules to produce more electrical power by 17% compared to the conventional PV at noon. The higher the electrical power generated, the higher the efficiency can be achieved in the scenario with PCM units. The daily electrical efficiency of the PV with PCM units was 14.14% higher than the conventional PV. This study illustrates that using encapsulated PCM units as a passive method is a strong and affordable method to improve the PVs’ electrical efficiency.
- Open Access
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (1) , 28-36
Energy Analysis of a Novel Perforated Cross-flow Solar Air Heaters Integrated with Encapsulated Phase Change Material Units: An Experimental Study
This study analyzes the thermal efficiency of a new perforated cross-flow solar air heater (SAH) integrated with encapsulated phase change material (PCM) by using an experimnetal approach. Since SAHs represent low thermal efficiencies, this study introduces a novel SAH that uses two methods to address this problem: the perforated absorber with cross-flow configuration and encapsulated latent heat storage (PCM) units. The perforated cross-flow configuration improves the turbulence and, consequently, the heat exchange rate in SAHs and improves instantaneous efficiency. PCM units store thermal energy, prolong the operating period, and increase long-term efficiency. To perform thermal analysis, a perforated SAH with encapsulated PCM units was fabricated and tested outdoors at mair = of 0.012 kg/s and 0.024 kg/s in autumn while ambient and operating parameters were monitored. The experimental data reveal that the outlet temperature reaches the peak value of 38 oC and 32 oC. At mair = 0.012 kg/s and 0.024 kg/s, the temperature readings were 12 oC and 6 oC higher than the ambient temperature respectively. During the day, the charge/discharge process occurs in the encapsulated PCM units, avoids sharp temperature gradients and flattens the outlet and absorber temperatures’ profiles. The fabricated SAH reaches the highest thermal efficiency of nearly 83.7% at mair = 0.024 kg/s, which is a suitable value compared to common SAHs.
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (1) , 28-36
Open AccessEnergy Analysis of a Novel Perforated Cross-flow Solar Air Heaters Integrated with Encapsulated Phase Change Material Units: An Experimental Study
This study analyzes the thermal efficiency of a new perforated cross-flow solar air heater (SAH) integrated with encapsulated phase change material (PCM) by using an experimnetal approach. Since SAHs represent low thermal efficiencies, this study introduces a novel SAH that uses two methods to address this problem: the perforated absorber with cross-flow configuration and encapsulated latent heat storage (PCM) units. The perforated cross-flow configuration improves the turbulence and, consequently, the heat exchange rate in SAHs and improves instantaneous efficiency. PCM units store thermal energy, prolong the operating period, and increase long-term efficiency. To perform thermal analysis, a perforated SAH with encapsulated PCM units was fabricated and tested outdoors at mair = of 0.012 kg/s and 0.024 kg/s in autumn while ambient and operating parameters were monitored. The experimental data reveal that the outlet temperature reaches the peak value of 38 oC and 32 oC. At mair = 0.012 kg/s and 0.024 kg/s, the temperature readings were 12 oC and 6 oC higher than the ambient temperature respectively. During the day, the charge/discharge process occurs in the encapsulated PCM units, avoids sharp temperature gradients and flattens the outlet and absorber temperatures’ profiles. The fabricated SAH reaches the highest thermal efficiency of nearly 83.7% at mair = 0.024 kg/s, which is a suitable value compared to common SAHs.
- Open Access
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (2) , 188-195
Thermal Assessment of a Novel Thermal Diode Solar Water Heater Using Different Heat Transfer Fluids: An Experimental Study
Thermal diode solar water heaters (SWHs) are novel, promising tools that address an inherent problem in SWHs: significant heat losses. Thermal diodes SWHs use heat transfer fluids (HTFs) to carry out this crucial task, or in other words, to improve the heat transfer rate during the collection period and reduce its retention period. This study investigates how HTFs affect the performance of thermal diode SWHs. To this aim, a thermal diode SWH was fabricated and tested outdoors using two common HTFs: pure water and ethanol-water azeotrope. Ethanol-water azeotrope has a lower boiling point and latent heat than pure water; hence, it goes through the phase change process sooner and faster than pure water. The results reveal that the maximum reserved water temperature in the SWH using azeotrope is nearly 17.7% higher than in the SWH using pure water. Furthermore, the reserved water in the SWH using azeotrope loses its thermal energy in a gentler gradient than the water in the SWH using pure water during the retention period. The collection and retention efficiencies of the SWH using azeotrope are nearly 37.83% and 130.2% higher than those using pure water. Hence, ethanol-water azeotrope is a suitable material, serving as HTF in thermal diode SWHs.
- 1 January 2025
- Published by International Digital Organization for Scientific Information (IDOSI) in Iranica Journal of Energy and Environment
- Vol. 16 (2) , 188-195
Open AccessThermal Assessment of a Novel Thermal Diode Solar Water Heater Using Different Heat Transfer Fluids: An Experimental Study
Thermal diode solar water heaters (SWHs) are novel, promising tools that address an inherent problem in SWHs: significant heat losses. Thermal diodes SWHs use heat transfer fluids (HTFs) to carry out this crucial task, or in other words, to improve the heat transfer rate during the collection period and reduce its retention period. This study investigates how HTFs affect the performance of thermal diode SWHs. To this aim, a thermal diode SWH was fabricated and tested outdoors using two common HTFs: pure water and ethanol-water azeotrope. Ethanol-water azeotrope has a lower boiling point and latent heat than pure water; hence, it goes through the phase change process sooner and faster than pure water. The results reveal that the maximum reserved water temperature in the SWH using azeotrope is nearly 17.7% higher than in the SWH using pure water. Furthermore, the reserved water in the SWH using azeotrope loses its thermal energy in a gentler gradient than the water in the SWH using pure water during the retention period. The collection and retention efficiencies of the SWH using azeotrope are nearly 37.83% and 130.2% higher than those using pure water. Hence, ethanol-water azeotrope is a suitable material, serving as HTF in thermal diode SWHs.