Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seyed Amir Hosseini has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Variance‐Empirical Mode Decomposition Method for Fault Detection in MMC‐HVDC Transmission Lines

    by Seyed Amir Hosseini, Behrooz Taheri

    In this paper, a new method for fast and accurate fault detection in HVDC transmission lines based on modular multilevel converters (MMC HVDC) is presented. The proposed method, named variance‐based empirical mode decomposition (VEMD), relies on the statistical analysis of the variance of voltage and current signals measured from one side of the line and their decomposition using the empirical mode decomposition algorithm. As an indicator sensitive to sudden changes, variance highlights the transient characteristics caused by the occurrence of a fault, and the decomposition of the signal into oscillatory intrinsic mode functions allows the extraction of hidden frequency components. The performance of the proposed method has been evaluated through extensive simulation in the PSCAD environment and implementation in MATLAB software, as well as practical testing on a hardware system. The results show that the VEMD method is capable of detecting various types of faults, including high‐impedance faults up to 200 Ω, at different locations along the transmission line (25% to 90% of the line length). The fault detection time in noise‐free conditions is 12.46 ms on average, and in the presence of measurement noise with a signal‐to‐noise ratio of 40 dB, it is up to 22.25 ms. These results indicate the high accuracy, reasonable speed, noise immunity, and stable performance of the proposed method and demonstrate that the VEMD method can be used as a practical, reliable, communication‐link‐free solution for protecting MMC‐based HVDC transmission lines.

  • Open Access

    Enhanced Fault Detection and Classification in AC Microgrids Through a Combination of Data Processing Techniques and Deep Neural Networks

    by Behrooz Taheri, Seyed Amir Hosseini, Hamed Hashemi-Dezaki

    This paper introduces an innovative method for the intelligent protection of AC microgrids that incorporate renewable energy sources and electric vehicle charging stations. To extract relevant features, current signals from both sides of the distribution line are sampled. Subsequently, the differential current is calculated, and the resultant signals are processed using Compressed Sensing Theory and Variational Mode Decomposition to extract key features. These extracted features serve as input data for training the proposed wide and deep learning model. The proposed method was evaluated on a microgrid that incorporated electric vehicle chargers and wind turbines. The results indicate that this approach can effectively identify and categorize different types of faults in AC microgrids. Moreover, it demonstrates stable and dependable performance in the face of typical transients, and its accuracy is not influenced by uncertainties in the microgrid topology.


  • Open Access

    A Novel Hybrid Statistical Method for Power Swing Detection in Transmission Lines With Grid‐Following Inverter

    by Behrooz Taheri, Seyed Amir Hosseini

    This paper presents a new statistical approach for reliably detecting power swings and faults in transmission lines that include grid‐following (GFL) inverters. The method combines the strengths of the cumulative sum control chart (CUSUM) and entropy analysis (EA), using CUSUM's ability to quickly pick up on signal changes and EA's insight into system complexity. To test the proposed method, simulations were carried out in PSCAD/MATLAB on a modified IEEE 14‐bus system with a GFL‐type inverter‐based resource. The results show that the method can effectively detect both faults and power swings, even in the presence of additive white Gaussian noise (signal‐to‐noise ratio = 10 dB). It also accurately distinguishes between different transient events, such as load switching, generator trips, and capacitor bank switching, with a 100% success rate in identifying non‐fault conditions. Furthermore, it consistently detects faults across a range of fault resistances (0 to 10 Ω) with perfect accuracy. Compared to existing techniques, this approach performs better in systems that integrate GFL inverters and offers a more efficient solution with lower computational requirements for power system protection.


  • Open Access

    Fault Detection in a Single-Bus DC Microgrid Connected to EV/PV Systems and Hybrid Energy Storage Using the DMD-IF Method

    by Alireza Sistani, Seyed Amir Hosseini, Vahideh Sadat Sadeghi, Behrooz Taheri

    Variations in fault currents, short times to clear the fault, and a lack of a natural current zero-crossing point are the most important challenges that DC microgrid protection faces. This challenge becomes more complicated with the presence of electric vehicles and energy storage systems due to their uncertainties. For this reason, in this paper, a new method for fault detection in DC microgrids with the presence of electric vehicles and energy storage systems is proposed. The new proposed method uses the combination of dynamic mode decomposition and instantaneous frequency for fault detection. In this method, first, a reference signal is made using the voltage and current signal sampled from the DC microgrid using the dynamic mode decomposition method. Next, in order to detect the fault, the instantaneous frequency value of the reference signal is calculated by the Hilbert transform. The simultaneous use of voltage and current signals reduces the transient effects of the control system on the proposed protection method. In order to measure voltage and current signals, only one intelligent electronic device unit is used in this paper. The proposed new method has been tested on a single-bus DC microgrid with the presence of electric vehicles and energy storage systems in MATLAB 2019b software. The results show that this method can detect all types of faults in DC microgrids, electric vehicles, and photovoltaics. Also, this method is immune to the uncertainties of the generation of distributed generation resources and the existence of noise distortions in the measured signals.


  • Open Access

    An overview of power swing detection methods in distance relays and the factors involved

    by Behrooz Taheri, Seyed Amir Hosseini, Sirus Salehimehr

    Nowadays, due to the simplicity of operation and proper coordination characteristics, distance relays are being extensively used in the protection of power transmission lines. Despite many advantages, the distance relay is exposed to a maloperation when a power swing phenomenon occurs. Power swings may occur due to major disturbances, such as switching lines, generator interruptions, and connecting or disconnecting a large part of the loads, causing outages in healthy lines. Detecting power swing and preventing distance relay maloperation has always been a challenge. In addition, different parameters can have a great impact on the performance of power swing detection methods. In this paper, these parameters and their effects are examined along with various methods for detecting power swings. Accordingly, this comprehensive review covers all aspects of power swing phenomenon and its detection, including causes of power swings, power swing detection methods, determining threshold values in power swing methods, effecting of compensated lines and wind farms in power swing detection methods, and testing power swing function in the distance relays. It is hoped that this study will be helpful for researchers in power system protection to find relevant references and develop new methods for power swing function.


  • Open Access

    Proposing a New Approach to Generate the Differential Trajectory of the Differential Relays Using COMTRADE Files

    by Seyed Amir Hosseini, Ali Akbar Nazari, Behrooz Taheri, Farzad Razavi, Hamed Hashemi-Dezaki

    The differential relay is subject to transient events such as inrush current, which may affect its correct operation. Therefore, evaluating the reliable and accurate operation of differential relays is important, which is only possible by mapping the relay’s differential trajectory on its setting curve. However, except for the SIGRA software, creating a differential trajectory only for Siemens relays, there is a gap in developing a method to extract this trajectory for other commercial differential relays. Hence, in this paper, a new method for generating the differential trajectory of the differential relay from their six input currents and mapping it on the relay setting curve is presented. The proposed method uses the differential relay COMTRADE files to access the relay input currents during an incident. The currents recorded in the COMTRADE files belong to the secondary sides of the current transformers (CTs). Accordingly, the impacts of the current transformers’ connections and the protected transformer’s connection type should be considered in the proposed study. The ability of the proposed method to generate the differential trajectory for different incidents that occurred on the power transformers is evaluated using simulation studies and also according to the experimental tests. The results illustrate the efficiency of the proposed method in generating the differential trajectory from the COMTRADE files. In addition, comparing the results of the proposed method with the results created in SIGRA software shows the higher accuracy of the proposed method in producing the differential trajectory of the differential relay.