Lindsey L. Reader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lindsey L. Reader has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Alexis Moore Crisp
Iadarola Center, Room 204, Cabrini University, 610 King of Prussia Road, Radnor, PA 19087, USA
1 shared publication- Clinton J. Barnes
School of Life Sciences , 4505 S. Maryland Parkway , University of Nevada Las Vegas, Las Vegas, NV 89154, USA
1 shared publication Cody McGrale
University of Utah
1 shared publicationDavid R. Carrier
Department of Biology, 201 South Biology Building, University of Utah, Salt Lake City, UT 84112, USA
1 shared publicationDavid V. Lee
School of Life Sciences , 4505 S. Maryland Parkway , University of Nevada Las Vegas, Las Vegas, NV 89154, USA
1 shared publicationFranz Goller
Department of Biology, 201 South Biology Building, University of Utah, Salt Lake City, UT 84112, USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Paper 13: Traction Application Method Influences Force and Distraction Parameters at Venting and Capsulotomy
Objectives: This study examined the effects of traction application method – either a standard peroneal post or a postless method -- on traction and distraction variables before and after venting and capsulotomy. A more robust understanding of the direct effects of each intervention under different traction conditions may inform clinical decisions about compartment access and/or methods of traction application. Methods: Fluoroscopic images were taken before and after traction application, venting, and capsulotomy in primary hip arthroscopies by a single surgeon; these were used to measure distraction distances, which were each normalized to the diameter of the femoral head in the same image to account for the effect any purely positional differences across time points. Traction forces were also recorded at traction application, before/after venting, and before/after capsulotomy. Traction method, as well as sex and hamstring flexibility scores (known to influence degree of distraction) were assessed via standard least squares models for their effects on: 1) Instantaneous traction forces before venting, after venting, before capsulotomy, and after capsulotomy 2) Distraction differences -- expressed as % femoral head diameter -- between the neutral state and the values at these same interventions 3) The ratios of normalized distraction differences to traction forces at each intervention Results: Both initial distraction and after-venting distraction values differed significantly with respect to sex (distraction: p<0.0001, venting: p<0.0001 ), and hamstring flexibility (distraction: p<0.0140, venting: p<0.0040), with larger distraction magnitudes in female and more flexible patients. After-capsulotomy distraction differed with sex (p<0.0001) and traction method (p<0.0056), with female and peroneal post-distracted patients exhibiting higher distraction magnitudes. All force values along the intervention trajectory (before and after venting, before and after capsulotomy) differed with respect to sex and traction method, but not with hamstring flexibility (Table1). Male patients and post-distracted patients exhibited higher forces. Distraction-traction ratios (distraction achieved per unit force applied) differed with respect to sex, traction method, and hamstring flexibility at all interventions – except for the after-capsulotomy ratio, which was unaffected by hamstring flexibility (Table 1). Higher values (more distraction achieved per unit force) were seen in more flexible patients, female patients, and patients distracted via the postless method. The differences between ratios before and after an intervention differed with respect to sex for venting (p<0.0106), and both sex and traction method for capsulotomy (sex: p<0.0001 traction: p<0.0379), representing more distraction achieved per unit force after capsulotomy in the post-distracted group, and for female patients at both interventions. Conclusions: The distraction results indicate that the posted and postless methods of traction application do not differ significantly in the magnitude of distraction achieved (except after capsulotomy), but depend more on patient flexibility. The fact that after-capsulotomy distractions are larger in the post-distracted group may point to differences in soft tissue strain patterns between traction application methods. Traction forces are higher in post-distracted group but yield lower distraction distances per unit force than the postless method overall; the exception to this pattern is the ratio taken after capsulotomy, which is higher in the post-distracted group. Taken together, these results may support a switch to postless methods and invite further investigation into the anatomical and mechanical patterns governing capsular integrity.
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Open AccessPaper 13: Traction Application Method Influences Force and Distraction Parameters at Venting and Capsulotomy
Objectives: This study examined the effects of traction application method – either a standard peroneal post or a postless method -- on traction and distraction variables before and after venting and capsulotomy. A more robust understanding of the direct effects of each intervention under different traction conditions may inform clinical decisions about compartment access and/or methods of traction application. Methods: Fluoroscopic images were taken before and after traction application, venting, and capsulotomy in primary hip arthroscopies by a single surgeon; these were used to measure distraction distances, which were each normalized to the diameter of the femoral head in the same image to account for the effect any purely positional differences across time points. Traction forces were also recorded at traction application, before/after venting, and before/after capsulotomy. Traction method, as well as sex and hamstring flexibility scores (known to influence degree of distraction) were assessed via standard least squares models for their effects on: 1) Instantaneous traction forces before venting, after venting, before capsulotomy, and after capsulotomy 2) Distraction differences -- expressed as % femoral head diameter -- between the neutral state and the values at these same interventions 3) The ratios of normalized distraction differences to traction forces at each intervention Results: Both initial distraction and after-venting distraction values differed significantly with respect to sex (distraction: p<0.0001, venting: p<0.0001 ), and hamstring flexibility (distraction: p<0.0140, venting: p<0.0040), with larger distraction magnitudes in female and more flexible patients. After-capsulotomy distraction differed with sex (p<0.0001) and traction method (p<0.0056), with female and peroneal post-distracted patients exhibiting higher distraction magnitudes. All force values along the intervention trajectory (before and after venting, before and after capsulotomy) differed with respect to sex and traction method, but not with hamstring flexibility (Table1). Male patients and post-distracted patients exhibited higher forces. Distraction-traction ratios (distraction achieved per unit force applied) differed with respect to sex, traction method, and hamstring flexibility at all interventions – except for the after-capsulotomy ratio, which was unaffected by hamstring flexibility (Table 1). Higher values (more distraction achieved per unit force) were seen in more flexible patients, female patients, and patients distracted via the postless method. The differences between ratios before and after an intervention differed with respect to sex for venting (p<0.0106), and both sex and traction method for capsulotomy (sex: p<0.0001 traction: p<0.0379), representing more distraction achieved per unit force after capsulotomy in the post-distracted group, and for female patients at both interventions. Conclusions: The distraction results indicate that the posted and postless methods of traction application do not differ significantly in the magnitude of distraction achieved (except after capsulotomy), but depend more on patient flexibility. The fact that after-capsulotomy distractions are larger in the post-distracted group may point to differences in soft tissue strain patterns between traction application methods. Traction forces are higher in post-distracted group but yield lower distraction distances per unit force than the postless method overall; the exception to this pattern is the ratio taken after capsulotomy, which is higher in the post-distracted group. Taken together, these results may support a switch to postless methods and invite further investigation into the anatomical and mechanical patterns governing capsular integrity.
- Open Access
- 1 January 2022
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 225 (1)
Climbing parrots achieve pitch stability using forces and free moments produced by axial–appendicular couples
During vertical climbing, the gravitational moment tends to pitch the animal's head away from the climbing surface and this may be countered by (1) applying a correcting torque at a discrete contact point, or (2) applying opposing horizontal forces at separate contact points to produce a free moment. We tested these potential strategies in small parrots with an experimental climbing apparatus imitating the fine branches and vines of their natural habitat. The birds climbed on a vertical ladder with four instrumented rungs that measured three-dimensional force and torque, representing the first measurements of multiple contacts from a climbing bird. The parrots ascend primarily by pulling themselves upward using the beak and feet. They resist the gravitational pitching moment with a free moment produced by horizontal force couples between the beak and feet during the first third of the stride and the tail and feet during the last third of the stride. The reaction torque from individual rungs did not counter, but exacerbated the gravitational pitching moment, which was countered entirely by the free moment. Possible climbing limitations were explored using two different rung radii, each with low and high friction surfaces. Rung torque was limited in the large-radius, low-friction condition; however, rung condition did not significantly influence the free moments produced. These findings have implications for our understanding of avian locomotor modules (i.e. coordinated actions of the head–neck, hindlimbs and tail), the use of force couples in vertical locomotion, and the evolution of associated structures.
- 1 January 2022
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 225 (1)
Open AccessClimbing parrots achieve pitch stability using forces and free moments produced by axial–appendicular couples
During vertical climbing, the gravitational moment tends to pitch the animal's head away from the climbing surface and this may be countered by (1) applying a correcting torque at a discrete contact point, or (2) applying opposing horizontal forces at separate contact points to produce a free moment. We tested these potential strategies in small parrots with an experimental climbing apparatus imitating the fine branches and vines of their natural habitat. The birds climbed on a vertical ladder with four instrumented rungs that measured three-dimensional force and torque, representing the first measurements of multiple contacts from a climbing bird. The parrots ascend primarily by pulling themselves upward using the beak and feet. They resist the gravitational pitching moment with a free moment produced by horizontal force couples between the beak and feet during the first third of the stride and the tail and feet during the last third of the stride. The reaction torque from individual rungs did not counter, but exacerbated the gravitational pitching moment, which was countered entirely by the free moment. Possible climbing limitations were explored using two different rung radii, each with low and high friction surfaces. Rung torque was limited in the large-radius, low-friction condition; however, rung condition did not significantly influence the free moments produced. These findings have implications for our understanding of avian locomotor modules (i.e. coordinated actions of the head–neck, hindlimbs and tail), the use of force couples in vertical locomotion, and the evolution of associated structures.