Kyung Sik Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kyung Sik Yi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Chi-Hoon Choi
Department of Radiology, College of Medicine, Chungbuk National University, Cheongju, Republic of Korea
9 shared publications - Yook Kim
Department of Radiology, College of Medicine, Chungbuk National University, Chungbuk National University Hospital, Cheongju, Republic of Korea
7 shared publications Jisun Lee
Department of Radiology, Chungbuk National University Hospital, Cheongju, South Korea
5 shared publications- Jisun Lee
College of Medicine, Chungbuk National University, Cheongju-si, Republic of Korea
4 shared publications Chi-Hoon Choi
Department of Radiology, Chungbuk National University Hospital, Republic of Korea
3 shared publicationsSang-Hoon Cha
Chungbuk Natl Univ Hosp, Dept Radiol, 776 1Sunhwan Ro, Cheongju 28644, South Korea
3 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0352263
A human 3D BBB chip model of acute stroke simulating a reversible penumbra.
Ischemic stroke is a leading cause of mortality and disability worldwide. However, existing models often fail to replicate key aspects of human pathophysiology, particularly blood-brain barrier (BBB) dysfunction and the salvageable ischemic penumbra. We developed a three-dimensional BBB chip model of acute ischemic stroke that reproduces penumbra-like, partially reversible BBB injury. This platform integrates a microfluidic BBB chip (Emulate) with parallel Transwell inserts to facilitate complementary structural, molecular, and functional analyses. Ischemia-like injury was induced using 2.5 μM antimycin A for 1 hour under oxygen-glucose deprivation conditions, followed by medium replacement to simulate reperfusion. Therapeutic hypothermia (33°C) was also applied during the reperfusion phase. The combination of reperfusion and hypothermia resulted in the most pronounced restoration of BBB integrity compared with reperfusion alone. The Emulate chip enabled structural evaluation of endothelial morphology, while the transwell model showed concordant recovery of BBB-related markers, including ZO-1 and VE-cadherin, along with decreased expression of the hypoxia-associated marker HIF-1α. This integrated platform enabled evaluation of BBB injury and recovery under ischemia- and reperfusion-like conditions. Our human cell-based 3D BBB stroke model captures key BBB-related features of penumbra-like injury and provides a human-relevant in vitro platform for investigating stroke pathophysiology and evaluating therapeutic strategies.
- 14 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0352263
Open AccessA human 3D BBB chip model of acute stroke simulating a reversible penumbra.
Ischemic stroke is a leading cause of mortality and disability worldwide. However, existing models often fail to replicate key aspects of human pathophysiology, particularly blood-brain barrier (BBB) dysfunction and the salvageable ischemic penumbra. We developed a three-dimensional BBB chip model of acute ischemic stroke that reproduces penumbra-like, partially reversible BBB injury. This platform integrates a microfluidic BBB chip (Emulate) with parallel Transwell inserts to facilitate complementary structural, molecular, and functional analyses. Ischemia-like injury was induced using 2.5 μM antimycin A for 1 hour under oxygen-glucose deprivation conditions, followed by medium replacement to simulate reperfusion. Therapeutic hypothermia (33°C) was also applied during the reperfusion phase. The combination of reperfusion and hypothermia resulted in the most pronounced restoration of BBB integrity compared with reperfusion alone. The Emulate chip enabled structural evaluation of endothelial morphology, while the transwell model showed concordant recovery of BBB-related markers, including ZO-1 and VE-cadherin, along with decreased expression of the hypoxia-associated marker HIF-1α. This integrated platform enabled evaluation of BBB injury and recovery under ischemia- and reperfusion-like conditions. Our human cell-based 3D BBB stroke model captures key BBB-related features of penumbra-like injury and provides a human-relevant in vitro platform for investigating stroke pathophysiology and evaluating therapeutic strategies.
- Open Access
- 10 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (28) , e49671
Solid serous adenoma of the pancreas mimicking a solid pseudopapillary neoplasm: A case report
Rationale: Serous cystic neoplasms of the pancreas are benign epithelial tumors that typically present as microcystic lesions. However, a rare solid variant, known as solid serous adenoma, may appear as a solid hypervascular mass and mimic other solid pancreatic tumors. Patient concerns: An asymptomatic woman in her early 50s was referred for evaluation of an incidentally detected pancreatic tail mass. Diagnoses: Computed tomography and magnetic resonance imaging demonstrated heterogeneous peripheral enhancement with progressive centripetal fill-in and a persistent hypoenhancing area. Based on these findings, a solid pseudopapillary neoplasm was initially suspected. Interventions: Because malignancy could not be excluded on imaging, the patient underwent distal pancreatectomy. Outcomes: Histopathological examination confirmed solid serous adenoma composed of glycogen-rich cuboidal epithelium forming numerous microcystic spaces. The imaging findings correlated with regional differences in stromal composition. The postoperative course was uneventful, and follow-up imaging showed no evidence of recurrence or residual disease. Lessons: Solid serous adenomas can exhibit variable imaging appearances and mimic other solid pancreatic tumors. Recognition of this entity is clinically important, as it may improve diagnostic accuracy and help prevent unnecessary surgical resection of benign pancreatic lesions.
- 10 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (28) , e49671
Open AccessSolid serous adenoma of the pancreas mimicking a solid pseudopapillary neoplasm: A case report
Rationale: Serous cystic neoplasms of the pancreas are benign epithelial tumors that typically present as microcystic lesions. However, a rare solid variant, known as solid serous adenoma, may appear as a solid hypervascular mass and mimic other solid pancreatic tumors. Patient concerns: An asymptomatic woman in her early 50s was referred for evaluation of an incidentally detected pancreatic tail mass. Diagnoses: Computed tomography and magnetic resonance imaging demonstrated heterogeneous peripheral enhancement with progressive centripetal fill-in and a persistent hypoenhancing area. Based on these findings, a solid pseudopapillary neoplasm was initially suspected. Interventions: Because malignancy could not be excluded on imaging, the patient underwent distal pancreatectomy. Outcomes: Histopathological examination confirmed solid serous adenoma composed of glycogen-rich cuboidal epithelium forming numerous microcystic spaces. The imaging findings correlated with regional differences in stromal composition. The postoperative course was uneventful, and follow-up imaging showed no evidence of recurrence or residual disease. Lessons: Solid serous adenomas can exhibit variable imaging appearances and mimic other solid pancreatic tumors. Recognition of this entity is clinically important, as it may improve diagnostic accuracy and help prevent unnecessary surgical resection of benign pancreatic lesions.
- Open Access
- 29 August 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (35) , e44183
Bilateral globus pallidus lesions associated with COVID-19: Mimicking acute carbon monoxide poisoning
Rationale: Bilateral symmetrical globus pallidus (GP) involvement associated with coronavirus disease 2019 (COVID-19) infection is an extremely rare finding among cases of COVID-19-related encephalopathy. Patient concerns: A 76-year-old man was diagnosed with pneumonia and subsequently tested positive for COVID-19. He was transferred to the hospital on day 9 after symptom onset due to worsening respiratory distress and hypotension. Despite improvement in his pneumonia following the transfer, his mental status remained altered throughout his hospital stay. Diagnoses: A neurologic work-up, including brain magnetic resonance imaging (MRI) performed 2 weeks after the onset of altered mental state, revealed symmetrical high signal intensity lesions in the bilateral GP on MRI. Interventions: The patient received high-flow nasal oxygen therapy with norepinephrine infusion for hemodynamic support, along with intravenous meropenem and remdesivir. Outcomes: The patient gradually recovered and was able to engage in simple communication by the 3rd week. Follow-up MRI at 5 weeks showed resolution of GP lesions. Lessons: Differentiating COVID-19-related encephalopathy from acute carbon monoxide poisoning is challenging in the presence when bilateral symmetrical GP lesions are present. However, coexisting multiple ischemic lesions – common in COVID-19-related encephalopathy but rare in carbon monoxide poisoning – may serve as a useful radiologic clue.
- 29 August 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (35) , e44183
Open AccessBilateral globus pallidus lesions associated with COVID-19: Mimicking acute carbon monoxide poisoning
Rationale: Bilateral symmetrical globus pallidus (GP) involvement associated with coronavirus disease 2019 (COVID-19) infection is an extremely rare finding among cases of COVID-19-related encephalopathy. Patient concerns: A 76-year-old man was diagnosed with pneumonia and subsequently tested positive for COVID-19. He was transferred to the hospital on day 9 after symptom onset due to worsening respiratory distress and hypotension. Despite improvement in his pneumonia following the transfer, his mental status remained altered throughout his hospital stay. Diagnoses: A neurologic work-up, including brain magnetic resonance imaging (MRI) performed 2 weeks after the onset of altered mental state, revealed symmetrical high signal intensity lesions in the bilateral GP on MRI. Interventions: The patient received high-flow nasal oxygen therapy with norepinephrine infusion for hemodynamic support, along with intravenous meropenem and remdesivir. Outcomes: The patient gradually recovered and was able to engage in simple communication by the 3rd week. Follow-up MRI at 5 weeks showed resolution of GP lesions. Lessons: Differentiating COVID-19-related encephalopathy from acute carbon monoxide poisoning is challenging in the presence when bilateral symmetrical GP lesions are present. However, coexisting multiple ischemic lesions – common in COVID-19-related encephalopathy but rare in carbon monoxide poisoning – may serve as a useful radiologic clue.
- Open Access
- 29 August 2025
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 53 (8)
Entrapment of microguidewire into perforator during endovascular treatment: Case report and management strategy
Despite advancements in endovascular equipment, life-threatening procedure-related complications, including arterial perforation, remain a concern. In particular, microguidewire entrapment in perforating arteries poses a significant risk of arterial avulsion injury. However, limited guidance exists on effectively managing such scenarios, and to the best of our knowledge, no cases of successful resolution of entrapment using nimodipine have been reported to date. A woman in her mid-60s with a history of anterior communicating artery aneurysm coil embolization presented with aneurysm regrowth. During stent-assisted coil embolization, a microguidewire was entrapped in the perforating artery. An additional microcatheter was inserted near the site of entrapment, and 2.3 mg of intra-arterial nimodipine was infused over 15 min while attempting retrieval with extreme caution. The entrapped microguidewire was successfully removed, and the planned stent-assisted coil embolization was completed without complications. Microguidewire entrapment in a perforating artery during endovascular treatment poses the risk of fatal avulsion injury. Gentle and cautious retrieval, supported by sufficient intra-arterial nimodipine administration, may provide a safer approach for managing such complications.
- 29 August 2025
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 53 (8)
Open AccessEntrapment of microguidewire into perforator during endovascular treatment: Case report and management strategy
Despite advancements in endovascular equipment, life-threatening procedure-related complications, including arterial perforation, remain a concern. In particular, microguidewire entrapment in perforating arteries poses a significant risk of arterial avulsion injury. However, limited guidance exists on effectively managing such scenarios, and to the best of our knowledge, no cases of successful resolution of entrapment using nimodipine have been reported to date. A woman in her mid-60s with a history of anterior communicating artery aneurysm coil embolization presented with aneurysm regrowth. During stent-assisted coil embolization, a microguidewire was entrapped in the perforating artery. An additional microcatheter was inserted near the site of entrapment, and 2.3 mg of intra-arterial nimodipine was infused over 15 min while attempting retrieval with extreme caution. The entrapped microguidewire was successfully removed, and the planned stent-assisted coil embolization was completed without complications. Microguidewire entrapment in a perforating artery during endovascular treatment poses the risk of fatal avulsion injury. Gentle and cautious retrieval, supported by sufficient intra-arterial nimodipine administration, may provide a safer approach for managing such complications.
- 30 June 2025
- Published by Institute of Brain-Based Education in Brain, Digital, & Learning
- Vol. 15 (2) , 205-216
Utilizing Open Access Publications and Educational Content in LLM-Based Research: Global Trends and Ethical–Policy Considerations
Large language models (LLMs) have become increasingly ingrained in academic research and education. As a result, leveraging open-access publications and publicly available educational materials through LLMs is emerging as a promising strategy to broaden knowledge discovery and enhance teaching and learning. This review surveys global and domestic trends in the application of LLMs within science and education, highlighting notable implementations including Meta’s Galactica, KISTI’s KONI model, and the opensource CleverBee system. These examples showcase the substantial potential of generative AI when applied to openly available knowledge resources, while also revealing important limitations. In this context, we identify six key ethical challenges associated with LLM use—covering issues of copyright and licensing, personal data privacy, hallucinated content, algorithmic bias, plagiarism, and accountability—and examine evolving legal and regulatory responses in the United States, European Union, and South Korea. Additionally, we propose seven practical recommendations for researchers (such as checking data licenses, removing personal identifiers, verifying model outputs, and transparently reporting AI assistance) to foster responsible use of LLMs. Drawing on up-to-date guidelines from organizations like the Committee on Publication Ethics (COPE) and the International Committee of Medical Journal Editors (ICMJE) as well as recent national policy directives, this review offers comprehensive guidance for scholars across disciplines including neuroscience, linguistics, learning sciences, and artificial intelligence. Our aim is to support the responsible and effective integration of LLM technologies into academic practice—advancing innovation in research and education while maintaining high ethical and legal standards.
- 30 June 2025
- Published by Institute of Brain-Based Education in Brain, Digital, & Learning
- Vol. 15 (2) , 205-216
Utilizing Open Access Publications and Educational Content in LLM-Based Research: Global Trends and Ethical–Policy Considerations
Large language models (LLMs) have become increasingly ingrained in academic research and education. As a result, leveraging open-access publications and publicly available educational materials through LLMs is emerging as a promising strategy to broaden knowledge discovery and enhance teaching and learning. This review surveys global and domestic trends in the application of LLMs within science and education, highlighting notable implementations including Meta’s Galactica, KISTI’s KONI model, and the opensource CleverBee system. These examples showcase the substantial potential of generative AI when applied to openly available knowledge resources, while also revealing important limitations. In this context, we identify six key ethical challenges associated with LLM use—covering issues of copyright and licensing, personal data privacy, hallucinated content, algorithmic bias, plagiarism, and accountability—and examine evolving legal and regulatory responses in the United States, European Union, and South Korea. Additionally, we propose seven practical recommendations for researchers (such as checking data licenses, removing personal identifiers, verifying model outputs, and transparently reporting AI assistance) to foster responsible use of LLMs. Drawing on up-to-date guidelines from organizations like the Committee on Publication Ethics (COPE) and the International Committee of Medical Journal Editors (ICMJE) as well as recent national policy directives, this review offers comprehensive guidance for scholars across disciplines including neuroscience, linguistics, learning sciences, and artificial intelligence. Our aim is to support the responsible and effective integration of LLM technologies into academic practice—advancing innovation in research and education while maintaining high ethical and legal standards.
- Open Access
- 9 August 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (32) , e39281
An unusual case of an 0.018-inch (0.457 mm) guidewire fracture during primary percutaneous nephrostomy for percutaneous nephrolithotomy treated without removal and followed up for 5 years: A case report and literature review
Introduction: Although rare, guidewire fractures can occur during interventional procedures. In most cases, the fractured guidewire segment can be removed. Patient concerns: We report the case of a 54-year-old woman who experienced a guidewire fracture during percutaneous nephrostomy (PCN) for percutaneous nephrolithotomy to remove renal stones. Diagnosis: Nephrolithiasis. Interventions: PCN and percutaneous nephrolithotomy. Outcomes: In this case, the remaining segment could not be removed and caused inflammation and infection. However, her symptoms improved with inpatient treatment. Therefore, she was discharged from the hospital and followed up for 5 years. Conclusion: When performing PCN to remove renal stones, the possibility of a guidewire fracture must be considered. If resistance or scraping is felt while handling the guidewire, then it should be replaced.
- 9 August 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (32) , e39281
Open AccessAn unusual case of an 0.018-inch (0.457 mm) guidewire fracture during primary percutaneous nephrostomy for percutaneous nephrolithotomy treated without removal and followed up for 5 years: A case report and literature review
Introduction: Although rare, guidewire fractures can occur during interventional procedures. In most cases, the fractured guidewire segment can be removed. Patient concerns: We report the case of a 54-year-old woman who experienced a guidewire fracture during percutaneous nephrostomy (PCN) for percutaneous nephrolithotomy to remove renal stones. Diagnosis: Nephrolithiasis. Interventions: PCN and percutaneous nephrolithotomy. Outcomes: In this case, the remaining segment could not be removed and caused inflammation and infection. However, her symptoms improved with inpatient treatment. Therefore, she was discharged from the hospital and followed up for 5 years. Conclusion: When performing PCN to remove renal stones, the possibility of a guidewire fracture must be considered. If resistance or scraping is felt while handling the guidewire, then it should be replaced.
- Open Access
- 12 January 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (2) , e36945
Post-surgical thyroid bed myofibroma simulating a recurrent papillary thyroid carcinoma: A case report and review of the literature
Rationale: Myofibromas are rare benign spindle cell tumors of the soft tissue, bone, or internal organs that occur at any age. Here, we report a post-surgical thyroid bed myofibroma that mimicked a papillary thyroid carcinoma. Patient concerns: A 56-year-old male presented with a mass in the thyroid surgical bed, detected 3 years post thyroidectomy following papillary carcinoma. Diagnosis: Thyroid ultrasonography revealed a well-defined, lobulated, hypoechoic, solid nodule, with large rod-like echogenic foci in the thyroid surgical bed. The development of a postoperative suture granuloma was considered. However, ultrasonography performed 12 months later showed a marked increase in the lesion size. Two fine needle aspiration cytology yielded nondiagnostic results. Intervention: Considering the possibility of local tumor recurrence, surgical resection was performed. Outcome: The diagnosis of a myofibroma was confirmed, and no additional treatment was administered. Lessons: It is challenging to differentiate lesions occurring on the thyroid surgical bed after surgery, from recurrent thyroid cancer. A lesion measuring 6 mm, with a degree of punctate echogenicity, suggests tumor recurrence. Moreover, myofibromas are extremely rare. This case highlights that it is advisable to perform a core needle biopsy in cases of nondiagnostic fine needle aspiration results.
- 12 January 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (2) , e36945
Open AccessPost-surgical thyroid bed myofibroma simulating a recurrent papillary thyroid carcinoma: A case report and review of the literature
Rationale: Myofibromas are rare benign spindle cell tumors of the soft tissue, bone, or internal organs that occur at any age. Here, we report a post-surgical thyroid bed myofibroma that mimicked a papillary thyroid carcinoma. Patient concerns: A 56-year-old male presented with a mass in the thyroid surgical bed, detected 3 years post thyroidectomy following papillary carcinoma. Diagnosis: Thyroid ultrasonography revealed a well-defined, lobulated, hypoechoic, solid nodule, with large rod-like echogenic foci in the thyroid surgical bed. The development of a postoperative suture granuloma was considered. However, ultrasonography performed 12 months later showed a marked increase in the lesion size. Two fine needle aspiration cytology yielded nondiagnostic results. Intervention: Considering the possibility of local tumor recurrence, surgical resection was performed. Outcome: The diagnosis of a myofibroma was confirmed, and no additional treatment was administered. Lessons: It is challenging to differentiate lesions occurring on the thyroid surgical bed after surgery, from recurrent thyroid cancer. A lesion measuring 6 mm, with a degree of punctate echogenicity, suggests tumor recurrence. Moreover, myofibromas are extremely rare. This case highlights that it is advisable to perform a core needle biopsy in cases of nondiagnostic fine needle aspiration results.
- Open Access
- 21 July 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (29) , e34323
The value of contrast-enhanced ultrasound in vascular injury from blunt abdominal trauma in solid organs: Comparison with multidetector computed tomography using angiography as the reference standard
To evaluate the accuracy of contrast-enhanced ultrasound (CEUS) for assessing vascular injury from blunt abdominal trauma in solid organs using angiography as the reference standard and to compare it with contrast-enhanced multidetector computed tomography (MDCT). Forty-nine patients with 52 blunt abdominal trauma lesions who underwent CEUS, MDCT, and angiography were enrolled in this retrospective study. Injuries included the liver (n = 23), kidney (n = 10), and spleen (n = 19). Vascular injury in solid organs was classified into 3 types: isolated pseudoaneurysm, pseudoaneurysm with low-velocity extravasation, and active bleeding. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of CEUS and MDCT for the detection and classification of vascular injury in solid organs were calculated based on angiography. The receiver operating characteristic curve analysis of each test was performed and compared. Thirty-nine vascular injuries in solid organs were detected and classified into 9 isolated pseudoaneurysms, 9 pseudoaneurysms with low-velocity extravasation, and 21 active bleeding based on angiography as the reference standard. The sensitivity, specificity, PPV, NPV, and accuracy for bleeding detection were 97.44%, 100.00%, 100.00%, 92.86%, and 98.08%, respectively, for CEUS and MDCT. The sensitivity, specificity, PPV, NPV, and accuracy of classification (isolated pseudoaneurysm vs. pseudoaneurysm with low-velocity extravasation or active bleeding) of bleeding were 96.67%, 87.50%, 96.67%, 87.50%, and 94.74%, respectively, for CEUS and 100.00%, 75.00%, 93.75%, 100.00%, and 94.74%, respectively, for MDCT. The area under the receiver operating characteristic curves of CEUS and MDCT for bleeding detection was 0.987, and the area under the receiver operating characteristic curves for CEUS and MDCT bleeding classification were 0.921 and 0.875, respectively. CEUS and MDCT exhibited comparable consistency with angiography for detecting and classifying vascular injury from blunt abdominal trauma in solid organs. Therefore, CEUS may be an accurate and rapid imaging tool to detect bleeding and determine the need for transcatheter arterial embolization. We suggest that CEUS could be considered a first-line approach during the preparation time before MDCT to determine the appropriate management for blunt abdominal trauma.
- 21 July 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (29) , e34323
Open AccessThe value of contrast-enhanced ultrasound in vascular injury from blunt abdominal trauma in solid organs: Comparison with multidetector computed tomography using angiography as the reference standard
To evaluate the accuracy of contrast-enhanced ultrasound (CEUS) for assessing vascular injury from blunt abdominal trauma in solid organs using angiography as the reference standard and to compare it with contrast-enhanced multidetector computed tomography (MDCT). Forty-nine patients with 52 blunt abdominal trauma lesions who underwent CEUS, MDCT, and angiography were enrolled in this retrospective study. Injuries included the liver (n = 23), kidney (n = 10), and spleen (n = 19). Vascular injury in solid organs was classified into 3 types: isolated pseudoaneurysm, pseudoaneurysm with low-velocity extravasation, and active bleeding. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of CEUS and MDCT for the detection and classification of vascular injury in solid organs were calculated based on angiography. The receiver operating characteristic curve analysis of each test was performed and compared. Thirty-nine vascular injuries in solid organs were detected and classified into 9 isolated pseudoaneurysms, 9 pseudoaneurysms with low-velocity extravasation, and 21 active bleeding based on angiography as the reference standard. The sensitivity, specificity, PPV, NPV, and accuracy for bleeding detection were 97.44%, 100.00%, 100.00%, 92.86%, and 98.08%, respectively, for CEUS and MDCT. The sensitivity, specificity, PPV, NPV, and accuracy of classification (isolated pseudoaneurysm vs. pseudoaneurysm with low-velocity extravasation or active bleeding) of bleeding were 96.67%, 87.50%, 96.67%, 87.50%, and 94.74%, respectively, for CEUS and 100.00%, 75.00%, 93.75%, 100.00%, and 94.74%, respectively, for MDCT. The area under the receiver operating characteristic curves of CEUS and MDCT for bleeding detection was 0.987, and the area under the receiver operating characteristic curves for CEUS and MDCT bleeding classification were 0.921 and 0.875, respectively. CEUS and MDCT exhibited comparable consistency with angiography for detecting and classifying vascular injury from blunt abdominal trauma in solid organs. Therefore, CEUS may be an accurate and rapid imaging tool to detect bleeding and determine the need for transcatheter arterial embolization. We suggest that CEUS could be considered a first-line approach during the preparation time before MDCT to determine the appropriate management for blunt abdominal trauma.
- Open Access
- 1 January 2023
- Published by XMLink in Korean Journal of Radiology
- Vol. 24 (2) , 145-154
First-Pass Recanalization with EmboTrap II in Acute Ischemic Stroke (FREE-AIS): A Multicenter Prospective Study
Baek JH, et al. Korean J Radiol. 2023 Feb;24(2):145-154. https://doi.org/10.3348/kjr.2022.0618
- 1 January 2023
- Published by XMLink in Korean Journal of Radiology
- Vol. 24 (2) , 145-154
Open AccessFirst-Pass Recanalization with EmboTrap II in Acute Ischemic Stroke (FREE-AIS): A Multicenter Prospective Study
Baek JH, et al. Korean J Radiol. 2023 Feb;24(2):145-154. https://doi.org/10.3348/kjr.2022.0618
- Open Access
- 4 November 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (6) , 1619-1627
Dilatation of Superior Ophthalmic Vein and Visual Disturbance by Central Venous Stenosis: A Case Mimicking Cavernous Sinus Dural Arteriovenous Fistula
Central venous stenosis is a relatively common complication in hemodialysis patients; however, jugular venous reflux (JVR) and increased intracranial pressure are rare, and associated progressive visual disturbance was reported in only a few cases. Here, we report a case of JVR with visual disturbance and increased intracranial pressure. Notably, the MRI was accompanied by a dilatation of the superior ophthalmic vein, which was mistaken for a cavernous sinus dural arteriovenous fistula (CSdAVF). The patient had JVR on time-of-flight MR angiography (TOF-MRA) and severe stenosis of the left brachiocephalic vein on conventional angiography. After balloon angioplasty for central venous stenosis, he was discharged after improvement of his visual disturbance. Although JVR due to central venous stenosis and CSdAVF might show similar symptoms, treatment plans are different. Therefore, it is important to distinguish radiologically based on a thorough review of MRI and TOF-MRA and confirm the central venous stenosis on cerebral angiography for the accurate diagnosis.
- 4 November 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (6) , 1619-1627
Open AccessDilatation of Superior Ophthalmic Vein and Visual Disturbance by Central Venous Stenosis: A Case Mimicking Cavernous Sinus Dural Arteriovenous Fistula
Central venous stenosis is a relatively common complication in hemodialysis patients; however, jugular venous reflux (JVR) and increased intracranial pressure are rare, and associated progressive visual disturbance was reported in only a few cases. Here, we report a case of JVR with visual disturbance and increased intracranial pressure. Notably, the MRI was accompanied by a dilatation of the superior ophthalmic vein, which was mistaken for a cavernous sinus dural arteriovenous fistula (CSdAVF). The patient had JVR on time-of-flight MR angiography (TOF-MRA) and severe stenosis of the left brachiocephalic vein on conventional angiography. After balloon angioplasty for central venous stenosis, he was discharged after improvement of his visual disturbance. Although JVR due to central venous stenosis and CSdAVF might show similar symptoms, treatment plans are different. Therefore, it is important to distinguish radiologically based on a thorough review of MRI and TOF-MRA and confirm the central venous stenosis on cerebral angiography for the accurate diagnosis.