Christopher Heuer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christopher Heuer has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Janina Bahnemann
Institute of Physics, University of Augsburg, Augsburg, Germany
10 shared publications - Ester Segal
Technion – Israel Institute of Technology
4 shared publications - Jonathan Nyenhuis
Institute of Physics, Chair of Technical Biology, University of Augsburg, 86159 Augsburg, Germany
2 shared publications - Josef Zürn
Institute of Physics, Chair of Technical Biology, University of Augsburg, 86159 Augsburg, Germany
2 shared publications Steffen Winkler
Institute of Physics University of Augsburg 86159 Augsburg Germany
2 shared publicationsThomas Scheper
Institute of Technical Chemistry, Leibniz University Hannover, Hannover 30167, Germany
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (41) , 48527-48537
Lab-on-a-chip device with an integrated surface acoustic wave micromixer for enhanced porous silicon biosensor performance
A lab-on-a-chip device with an integrated surface acoustic wave micromixer is demonstrated for sensitivity enhancement of a porous silicon biosensor using lactoferrin as a model biomarker.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (41) , 48527-48537
Open AccessLab-on-a-chip device with an integrated surface acoustic wave micromixer for enhanced porous silicon biosensor performance
A lab-on-a-chip device with an integrated surface acoustic wave micromixer is demonstrated for sensitivity enhancement of a porous silicon biosensor using lactoferrin as a model biomarker.
- Open Access
- 28 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 27109
Comparative numerical and experimental evaluation of 3D-printed micromixers for biotechnological applications
Micromixers are essential in microfluidic-based biotechnology and diagnostics, where reproducible reactions and rapid mass transfer are crucial. Although many geometries exist, consistent comparison across dimensions, fabrication methods, and evaluation techniques remains challenging. In this study, we present a comparative analysis of six micromixer designs, focusing on mixing efficiency, pressure drop, shear stress, and the energy-dissipation rate. The devices were fabricated using high-definition 3D printing and studied experimentally and with high-resolution computational fluid dynamics (CFD) simulations. Tests covered a wide Reynolds-number range (Re = 0.1–200). At both ends of this range, most designs achieved adequate mixing. The greatest disparities emerged in the intermediate regime (Re = 1–50), with the Kenics geometry outperforming all other designs. Our grid-optimized CFD results matched experimental trends and quantified local shear and energy-dissipation rates. Live/dead assays using an industrially relevant Chinese hamster ovary (CHO) cell line showed unchanged viability immediately after mixing and during subsequent cultivation. By combining experimentally validated CFD predictions, systematic grid-optimized assessment, and biological validation within a single framework, this study establishes a consistent basis for comparing micromixer designs and selecting those that match desired combinations of mixing performance, pressure drop, volume, shear stress, and the energy-dissipation rate.
- 28 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 27109
Open AccessComparative numerical and experimental evaluation of 3D-printed micromixers for biotechnological applications
Micromixers are essential in microfluidic-based biotechnology and diagnostics, where reproducible reactions and rapid mass transfer are crucial. Although many geometries exist, consistent comparison across dimensions, fabrication methods, and evaluation techniques remains challenging. In this study, we present a comparative analysis of six micromixer designs, focusing on mixing efficiency, pressure drop, shear stress, and the energy-dissipation rate. The devices were fabricated using high-definition 3D printing and studied experimentally and with high-resolution computational fluid dynamics (CFD) simulations. Tests covered a wide Reynolds-number range (Re = 0.1–200). At both ends of this range, most designs achieved adequate mixing. The greatest disparities emerged in the intermediate regime (Re = 1–50), with the Kenics geometry outperforming all other designs. Our grid-optimized CFD results matched experimental trends and quantified local shear and energy-dissipation rates. Live/dead assays using an industrially relevant Chinese hamster ovary (CHO) cell line showed unchanged viability immediately after mixing and during subsequent cultivation. By combining experimentally validated CFD predictions, systematic grid-optimized assessment, and biological validation within a single framework, this study establishes a consistent basis for comparing micromixer designs and selecting those that match desired combinations of mixing performance, pressure drop, volume, shear stress, and the energy-dissipation rate.
- Open Access
- 20 June 2026
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 100, 103542
Microfluidic platforms for the transient transfection of mammalian cells: recent developments and challenges
- 20 June 2026
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 100, 103542
Open AccessMicrofluidic platforms for the transient transfection of mammalian cells: recent developments and challenges
- Open Access
- 5 May 2025
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (6)
A 3D‐Printed Microfluidic Sensor Platform for Online Bioprocess Monitoring
In order to screen for optimal bioprocess parameters at higher throughput, researchers developing new biopharmaceuticals are increasingly turning to miniaturized cultivation systems with reduced space and media consumption. However, these systems still face challenges related to the continuous monitoring of critical bioprocess parameters, in particular, because sensor integration is often difficult, and sample volumes for offline measurements are limited. In this work, a novel 3D‐printed microfluidic lab‐on‐a‐chip sensor platform is presented, specifically designed to be compatible with a range of cultivation systems (including shake flasks, bioreactors, and custom microbioreactors). The microfluidic system acts as a miniaturized bypass, integrating sensors for real‐time monitoring of key bioprocess parameters (such as pH, pO₂, pCO₂, glucose, and lactate) without compromising culture volume. This system has been successfully applied in a proof‐of‐concept for the cultivation of Escherichia coli and Saccharomyces cerevisiae. In addition, this platform also includes an integrated sampling unit for small‐volume collection, thereby potentially enabling the analysis of complex analyte mixtures such as amino acids or recombinant proteins. The presented system thus represents a valuable tool for both real‐time online monitoring and offline analysis, contributing to the optimization of biopharmaceutical production processes.
- 5 May 2025
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (6)
Open AccessA 3D‐Printed Microfluidic Sensor Platform for Online Bioprocess Monitoring
In order to screen for optimal bioprocess parameters at higher throughput, researchers developing new biopharmaceuticals are increasingly turning to miniaturized cultivation systems with reduced space and media consumption. However, these systems still face challenges related to the continuous monitoring of critical bioprocess parameters, in particular, because sensor integration is often difficult, and sample volumes for offline measurements are limited. In this work, a novel 3D‐printed microfluidic lab‐on‐a‐chip sensor platform is presented, specifically designed to be compatible with a range of cultivation systems (including shake flasks, bioreactors, and custom microbioreactors). The microfluidic system acts as a miniaturized bypass, integrating sensors for real‐time monitoring of key bioprocess parameters (such as pH, pO₂, pCO₂, glucose, and lactate) without compromising culture volume. This system has been successfully applied in a proof‐of‐concept for the cultivation of Escherichia coli and Saccharomyces cerevisiae. In addition, this platform also includes an integrated sampling unit for small‐volume collection, thereby potentially enabling the analysis of complex analyte mixtures such as amino acids or recombinant proteins. The presented system thus represents a valuable tool for both real‐time online monitoring and offline analysis, contributing to the optimization of biopharmaceutical production processes.
- Open Access
- 7 November 2024
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 19 (24) , e202400717
3D Printing in Biocatalysis and Biosensing: From General Concepts to Practical Applications
3D printing has matured into a versatile technique that offers researchers many different printing methods and materials with varying properties. Nowadays, 3D printing is deployed within a myriad of different applications, ranging from chemistry to biotechnology –including bioanalytics, biocatalysis or biosensing. Due to its inherent design flexibility (which enables rapid prototyping) and ease of use, 3D printing facilitates the relatively quick and easy creation of new devices with unprecedented functions.. This review article describes how 3D printing can be employed for research in the fields of biochemistry and biotechnology, and specifically for biocatalysis and biosensor applications. We survey different relevant 3D printing techniques, as well as the surface activation and functionalization of 3D‐printed materials. Finally, we show how 3D printing is used for the fabrication of reaction ware and enzymatic assays in biocatalysis research, as well as for the generation of biosensors using aptamers, antibodies, and enzymes as recognition elements.
- 7 November 2024
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 19 (24) , e202400717
Open Access3D Printing in Biocatalysis and Biosensing: From General Concepts to Practical Applications
3D printing has matured into a versatile technique that offers researchers many different printing methods and materials with varying properties. Nowadays, 3D printing is deployed within a myriad of different applications, ranging from chemistry to biotechnology –including bioanalytics, biocatalysis or biosensing. Due to its inherent design flexibility (which enables rapid prototyping) and ease of use, 3D printing facilitates the relatively quick and easy creation of new devices with unprecedented functions.. This review article describes how 3D printing can be employed for research in the fields of biochemistry and biotechnology, and specifically for biocatalysis and biosensor applications. We survey different relevant 3D printing techniques, as well as the surface activation and functionalization of 3D‐printed materials. Finally, we show how 3D printing is used for the fabrication of reaction ware and enzymatic assays in biocatalysis research, as well as for the generation of biosensors using aptamers, antibodies, and enzymes as recognition elements.
- Open Access
- 13 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 382
A Novel 3D-Printed and Miniaturized Periodic Counter Current Chromatography System for Continuous Purification of Monoclonal Antibodies
Continuous chromatography has emerged as one of the most attractive methods for protein purification. Establishing such systems involves installing several chromatographic units in series to enable continuous separation processes and reduce the cost of the production of expensive proteins and biopharmaceuticals (such as monoclonal antibodies). However, most of the established systems are bulky and plagued by high dead volume, which requires further optimization for improved separation procedures. In this article, we present a miniaturized periodic counter-current chromatography (PCCC) system, which is characterized by substantially reduced dead volume when compared to traditional chromatography setups. The PCCC device was fabricated by 3D printing, allowing for flexible design adjustments and rapid prototyping, and has great potential to be used for the screening of optimized chromatography conditions and protocols. The functionality of the 3D-printed device was demonstrated with respect to the capture and polishing steps during a monoclonal antibody purification process. Furthermore, this novel miniaturized system was successfully used for two different chromatography techniques (affinity and ion-exchange chromatography) and two different types of chromatographic units (columns and membrane adsorbers). This demonstrated versability underscores the flexibility of this kind of system and its potential for utilization in various chromatography applications, such as direct product capture from perfusion cell cultures.
- 13 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 382
Open AccessA Novel 3D-Printed and Miniaturized Periodic Counter Current Chromatography System for Continuous Purification of Monoclonal Antibodies
Continuous chromatography has emerged as one of the most attractive methods for protein purification. Establishing such systems involves installing several chromatographic units in series to enable continuous separation processes and reduce the cost of the production of expensive proteins and biopharmaceuticals (such as monoclonal antibodies). However, most of the established systems are bulky and plagued by high dead volume, which requires further optimization for improved separation procedures. In this article, we present a miniaturized periodic counter-current chromatography (PCCC) system, which is characterized by substantially reduced dead volume when compared to traditional chromatography setups. The PCCC device was fabricated by 3D printing, allowing for flexible design adjustments and rapid prototyping, and has great potential to be used for the screening of optimized chromatography conditions and protocols. The functionality of the 3D-printed device was demonstrated with respect to the capture and polishing steps during a monoclonal antibody purification process. Furthermore, this novel miniaturized system was successfully used for two different chromatography techniques (affinity and ion-exchange chromatography) and two different types of chromatographic units (columns and membrane adsorbers). This demonstrated versability underscores the flexibility of this kind of system and its potential for utilization in various chromatography applications, such as direct product capture from perfusion cell cultures.
- Open Access
- 27 December 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (10) , 1305-1308
Photonic Si microwell architectures for rapid antifungal susceptibility determination of Candida auris
The application of a photonic silicon chip-based optical sensor system for expeditious and phenotypic antifungal susceptibility testing of Candida auris is presented.
- 27 December 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (10) , 1305-1308
Open AccessPhotonic Si microwell architectures for rapid antifungal susceptibility determination of Candida auris
The application of a photonic silicon chip-based optical sensor system for expeditious and phenotypic antifungal susceptibility testing of Candida auris is presented.
- Open Access
- 22 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (24) , 4950-4961
A 3D-printed microfluidic gradient generator with integrated photonic silicon sensors for rapid antimicrobial susceptibility testing
With antimicrobial resistance becoming a major threat to healthcare settings around the world, there is a paramount need for rapid point-of-care antimicrobial susceptibility testing (AST) diagnostics. Unfortunately, most currently available clinical AST tools are lengthy, laborious, or are simply inappropriate for point-of-care testing. Herein, we design a 3D-printed microfluidic gradient generator that automatically produces two-fold dilution series of clinically relevant antimicrobials. We first establish the compatibility of these generators for classical AST (i.e., broth microdilution) and then extend their application to include a complete on-chip label-free and phenotypic AST. This is accomplished by the integration of photonic silicon chips, which provide a preferential surface for microbial colonization and allow optical tracking of bacterial behavior and growth at a solid–liquid interface in real-time by phase shift reflectometric interference spectroscopic measurements (PRISM). Using Escherichia coli and ciprofloxacin as a model pathogen-drug combination, we successfully determine the minimum inhibitory concentration within less than 90 minutes. This gradient generator-based PRISM assay provides an integrated AST device that is viable for convenient point-of-care testing and offers a promising and most importantly, rapid alternative to current clinical practices, which extend to 8–24 h.
- 22 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (24) , 4950-4961
Open AccessA 3D-printed microfluidic gradient generator with integrated photonic silicon sensors for rapid antimicrobial susceptibility testing
With antimicrobial resistance becoming a major threat to healthcare settings around the world, there is a paramount need for rapid point-of-care antimicrobial susceptibility testing (AST) diagnostics. Unfortunately, most currently available clinical AST tools are lengthy, laborious, or are simply inappropriate for point-of-care testing. Herein, we design a 3D-printed microfluidic gradient generator that automatically produces two-fold dilution series of clinically relevant antimicrobials. We first establish the compatibility of these generators for classical AST (i.e., broth microdilution) and then extend their application to include a complete on-chip label-free and phenotypic AST. This is accomplished by the integration of photonic silicon chips, which provide a preferential surface for microbial colonization and allow optical tracking of bacterial behavior and growth at a solid–liquid interface in real-time by phase shift reflectometric interference spectroscopic measurements (PRISM). Using Escherichia coli and ciprofloxacin as a model pathogen-drug combination, we successfully determine the minimum inhibitory concentration within less than 90 minutes. This gradient generator-based PRISM assay provides an integrated AST device that is viable for convenient point-of-care testing and offers a promising and most importantly, rapid alternative to current clinical practices, which extend to 8–24 h.
- Open Access
- 31 March 2022
- Published by Wiley in Engineering in Life Sciences
- Vol. 22 (11) , 699-708
Invitro biocompatibility evaluation of a heat‐resistant 3D printing material for use in customized cell culture devices
Additive manufacturing (3D printing) enables the fabrication of highly customized and complex devices and is therefore increasingly used in the field of life sciences and biotechnology. However, the application of 3D‐printed parts in these fields requires not only their biocompatibility but also their sterility. The most common method for sterilizing 3D‐printed parts is heat steam sterilization—but most commercially available 3D printing materials cannot withstand high temperatures. In this study, a novel heat‐resistant polyacrylate material for high‐resolution 3D Multijet printing was evaluated for the first time for its resistance to heat steam sterilization and in vitro biocompatibility with mouse fibroblasts (L929), human embryonic kidney cells (HEK 293E), and yeast (Saccharomyces cerevisiae (S. cerevisiae)). Analysis of the growth and viability of L929 cells and the growth of S. cerevisiae confirmed that the extraction media obtained from 3D‐printed parts had no negative effect on the aforementioned cell types, while, in contrast, viability and growth of HEK 293E cells were affected. No different effects of the material on the cells were found when comparing heat steam sterilization and disinfection with ethanol (70%, v/v). In principle, the investigated material shows great potential for high‐resolution 3D printing of novel cell culture systems that are highly complex in design, customized and easily sterilizable—however, the biocompatibility of the material for other cell types needs to be re‐evaluated.
- 31 March 2022
- Published by Wiley in Engineering in Life Sciences
- Vol. 22 (11) , 699-708
Open AccessInvitro biocompatibility evaluation of a heat‐resistant 3D printing material for use in customized cell culture devices
Additive manufacturing (3D printing) enables the fabrication of highly customized and complex devices and is therefore increasingly used in the field of life sciences and biotechnology. However, the application of 3D‐printed parts in these fields requires not only their biocompatibility but also their sterility. The most common method for sterilizing 3D‐printed parts is heat steam sterilization—but most commercially available 3D printing materials cannot withstand high temperatures. In this study, a novel heat‐resistant polyacrylate material for high‐resolution 3D Multijet printing was evaluated for the first time for its resistance to heat steam sterilization and in vitro biocompatibility with mouse fibroblasts (L929), human embryonic kidney cells (HEK 293E), and yeast (Saccharomyces cerevisiae (S. cerevisiae)). Analysis of the growth and viability of L929 cells and the growth of S. cerevisiae confirmed that the extraction media obtained from 3D‐printed parts had no negative effect on the aforementioned cell types, while, in contrast, viability and growth of HEK 293E cells were affected. No different effects of the material on the cells were found when comparing heat steam sterilization and disinfection with ethanol (70%, v/v). In principle, the investigated material shows great potential for high‐resolution 3D printing of novel cell culture systems that are highly complex in design, customized and easily sterilizable—however, the biocompatibility of the material for other cell types needs to be re‐evaluated.
- Open Access
- 27 January 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (5) , 986-993
3D-Printed microfluidic device for protein purification in batch chromatography
Using high-precision 3D printing, we developed a microfluidic device capable of automated batch chromatography with low dead volume. The 3D-printed device enables easy integration and straightforward connection of external components.
- 27 January 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (5) , 986-993
Open Access3D-Printed microfluidic device for protein purification in batch chromatography
Using high-precision 3D printing, we developed a microfluidic device capable of automated batch chromatography with low dead volume. The 3D-printed device enables easy integration and straightforward connection of external components.