Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tao Li has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An ingestible device for automated sampling and location tracing in gastrointestinal tract

    by Tao Li, Jeremy Felton, Johnathan Lewis, Qisen Cheng, Ryan Meredith, Hsueh-Tsung Lu, Alexander Benken, Partha P. Dutta, Jinhui Liao, Xiangyu D. Zhao, et al.

    Fluids sampled from the gastrointestinal (GI) tract are of interest for evaluating the bioequivalence of oral medications, and more generally for evaluating GI-related diseases, and for profiling the individual gut microbiome. Existing options for capturing multiple fluid samples from specific locations in the GI tract are limited and invasive, particularly for the small intestine. Here, we report the development of an ingestible capsule for the collection of multiple fluid samples along the GI tract; we additionally report the use of data from sensors within the capsule to determine the sampling regions. The capsule has an ingestible size of Φ14 × 42 mm3. Within this volume, it includes three separate cartridges that capture and retain samples within capillaries; a stepper motor for positioning the sampling cartridges at a sampling port; a 3-axis accelerometer that enables a new method of correlating sample location; a microcontroller with wireless communication and sensor data storage capabilities; and batteries to power the device. We describe in vitro characterization and in vivo tests performed with canine models that have successfully verified the capabilities of the capsule. Fluid samples from the stomach, small intestine, and colon regions of the GI tract are identified by inertial measurements taken within the capsule, and correlated to measurements of the concentration of mesalamine (a drug used for testing) and the bile salt profile in each region, respectively.


  • A High Efficiency Miniature Multi-Tip Corona Charger for Nanoparticle Sensors

    by Chandrashekhar Choudhary, Tao Li

    This paper reports a miniature indirect unipolar corona charger with multiple discharge sites for high efficiency in nanoparticle charging, sizing and detection. A novel scalable and stackable design using multiple multi-discharge-rings (MDR) allows simultaneous discharges at multiple sites along the inner perimeter of each ring and over the charger length, providing increased ion concentration (Ni) and more uniform ion distribution and, despite shorter particle residence time (t) due to a miniaturized charger size, achieving high Nit product and thus charging efficiency. MDRs with tungsten discharge tips were fabricated using a batch process and integrated with 3D-printed housing. Experimental results successfully verified functions and demonstrated high Nit (8.95×106) and low particle losses (3.25% at 10.55nm), both of which showed significant improvements (up to two orders of magnitude) compared to other miniature corona chargers.

  • Nonplanar Wireless Differential Microsensor for Integration on Intravenous Catheters for Therapeutic Drug Monitoring and Other Applications

    by Jiaxin Jiang, Vidya Chidambaran, Tao Li

    This paper reports a nonplanar passive wireless differential microsensor integrated with intravenous (IV) catheters of small diameters to facilitate in situ real-time monitoring of concentrations of drugs or other target molecules/biomarkers in the bloodstream. The sensor is based on magnetoelastic (ME) transduction with passive wireless interrogation to detect target molecules as mass loading using a functionalized coating. It uses a differential configuration to distinguish the mass loading effect from variations caused by changes in surrounding fluid medium. The sensor was curved to match the catheter form factor with maximized active sensor surface area, packaged in housing with embedded microfluidic features for sample filtration/pretreatment, and integrated on an 18-gauge catheter with 1.3 mm outer diameter for demonstration. Preliminary experimental results validated functions of curved ME sensors with degraded performance due to curving fully restored by an optimized annealing process, demonstrating 5.3 Hz/ng mass sensitivity and proper differential operation with the medium effect eliminated.

  • A 3D Microfluidic Device with Vertical Channels toward In Vitro Reconstruction of Blood-Brain Barrier

    by Tianshuo Wang, Lan Dao, Ziyuan Guo, Tao Li

    This paper reports a three-dimensional microfluidic device with an array of vertical channels to enable regulated, continuous, vertical flows to emulate the environment for in vitro culturing of brain and blood vessel organoids. This is expected to ultimately lead to in vitro reconstruction of the blood-brain barrier that is of high interest to studies on mental illness mechanisms and drug delivery to the brain. Twelve vertical microfluidic channels, each with 300 µm diameter and 5 mm height, were formed in the high-permeability agar gel surrounding the organoid to realize the vertical circulation flows and to allow lateral diffusion flows. The combined vertical flow rate of all channels ranges from 2.1 to 6.8 mL/min under different control parameters. A 30-day-old human blood vessel organoid was planted into the device for initial culturing and flow function tests. The result indicates that the organoid was properly activated with effective flow generation in the culturing site of the device.

  • Open Access

    Passive Wireless Pressure Gradient Measurement System for Fluid Flow Analysis

    by Partha P. Dutta, Alexander C. Benken, Tao Li, John Richard Ordonez-Varela, Yogesh B. Gianchandani

    Using distributed MEMS pressure sensors to measure small flow rates in high resistance fluidic channels is fraught with challenges far beyond the performance of the pressure sensing element. In a typical core-flood experiment, which may last several months, flow-induced pressure gradients are generated in porous rock core samples wrapped in a polymer sheath. Measuring these pressure gradients along the flow path requires high resolution pressure measurement while contending with difficult test conditions such as large bias pressures (up to 20 bar) and temperatures (up to 125 °C), as well as the presence of corrosive fluids. This work is directed at a system for using passive wireless inductive-capacitive (LC) pressure sensors that are distributed along the flow path to measure the pressure gradient. The sensors are wirelessly interrogated with readout electronics placed exterior to the polymer sheath for continuous monitoring of experiments. Using microfabricated pressure sensors that are smaller than ø15 × 3.0 mm3, an LC sensor design model for minimizing pressure resolution, accounting for sensor packaging and environmental artifacts is investigated and experimentally validated. A test setup, built to provide fluid-flow pressure differentials to LC sensors with conditions that mimic placement of the sensors within the wall of the sheath, is used to test the system. Experimental results show the microsystem operating over full-scale pressure range of 20,700 mbar and temperatures up to 125 °C, while achieving pressure resolution of <1 mbar, and resolving gradients of 10–30 mL/min, which are typical in core-flood experiments.


  • An Implantable Differential Sensor with Passive Wireless Interrogation for In-Situ Early Detection of Periprosthetic Joint Infection

    by Jiaxin Jiang, Cole Napier, Chandrashekhar Choudhary, H. Claude Sagi, Chia-Ying Lin, Michael T. Archdeacon, Tao Li

    This paper presents an implantable, passive wireless biosensor for integration with knee joint prostheses to facilitate in situ early detection of periprosthetic joint infection (PJI). The magnetoelastic (ME) transduction mechanism of the sensor enables wireless interrogation without the need of an antenna or battery. Antibodies are immobilized on the sensor to target specific types of bacteria of interest. A novel differential configuration of the ME sensor is introduced to distinguish the response to target bacteria from variations in properties of the surrounding fluid medium. A triangular sensor geometry is used to help enhance mass sensitivity. Differential sensor operation was successfully verified in vitro for bacterial detection in E. coli suspensions with different viscosities ranging between 1-5.9 cP, demonstrating effective elimination of the effect of the fluid medium.


  • Battery-Powered Wireless Sensor Network for Non-Invasive Monitoring of Water Usage Events in Premise Plumbing Systems

    by Chandrashekhar Choudhary, Gagan Batra, Tianshuo Wang, Toritseju Omaghomi, Steven G. Buchberger, Tao Li

    Collection of extensive field data on timestamped usage of various fixtures in residential and commercial buildings is necessary to derive the $p$ -values, a probability factor of fixture use during peak hours for all fixture types. These values are critical to properly estimate instantaneous peak water demand when designing the premise plumbing systems of new buildings. This paper presents a wireless sensor network to address such requirement. The Zigbee-based sensor network includes a group of battery-powered, low-cost sensor modules, each with a size of $12\times 6.4\times 8.1\ \text{cm}^{3}$ , for non-invasive, real-time detection of waterflow events. Two sensing modalities, acoustic and calorimetric, are integrated in the sensor module to provide accurate detection of waterflow under various noise and interference conditions in the field. The sensor module has fast response time for detection with a time resolution as small as 0.25 sec. Power efficient operation strategies result in a long battery lifetime >68 days, more than adequate for the target application. Field tests in a cafeteria restroom and test deployment of the wireless sensor network successfully verified its design and implementation.


  • Non-Invasive Calorimetric Sensor for Waterflow Event Detection in Premise Plumbing Systems

    by Chandrashekhar Choudhary, Gagan Batra, Steven G. Buchberger, Tao Li

    Non-invasive and low-cost sensors for waterflow event detection are required to determine p-values for the estimation of peak water demand during premise plumbing system design. This paper presents a low-cost calorimetric flow sensor for non-invasive detection of waterflow inside copper waterpipes. As a critical design parameter, the distance between a heater and two symmetrically placed temperature sensors was optimized to maximize the thermal coupling between the heater and water through the pipe wall. A printed circuit board with commercial high-resolution temperature sensors as well as precision 3D-printed heater bridge and sensor mount were designed with features to improve heat conduction symmetry and to minimize undesired direct heat conduction paths between the heater and temperature sensors. The sensor mount also allows ease of deployment on waterpipes. The assembled device showed excellent heat conduction symmetry with a temperature offset <0.054°C. Tests with emulated water on/off events successfully verified the operation and functions of the sensor.


  • A PASSIVE WIRELESS DIFFERENTIAL SENSOR FOR IN-SITU EARLY DETECTION OF PERIPROSTHETIC JOINT INFECTION

    by Jiaxin Jiang, Krithika Sureshkumar, Chandrashekhar Choudhary, Tristan Kerkes, Claude Sagi, Chia-Ying Lin, Michael Archdeacon, Tao Li


  • Open Access

    An Autonomous Environmental Logging Microsystem (ELM) for Harsh Environments

    by Yu Sui, Alexander C. Benken, Yushu Ma, Andrew Trickey-Glassman, Tao Li, Yogesh B. Gianchandani

    This paper describes the design, implementation, and evaluation of an environmental logging microsystem (ELM) for operation at elevated pressure and in corrosive environments, at temperatures up to 125°C. The ELM units are intended to be deployed in large quantities, allowed to collect data, and then retrieved, interrogated, and re-charged. Powered by a rechargeable battery embedded within the system, each ELM incorporates pressure and temperature sensors, control electronics, optical communication elements, and power management and battery re-charging circuits. The pressure sensor is a customized capacitive transducer chip on a sapphire substrate; details are provided in a companion paper. The electronic components and battery used in ELM are selected on the basis of functionality and form factor; packaged components are selected for ease of assembly and for added protection against the environment. The pressure sensor, electronics and battery are assembled on a flexible circuit board, folded into a stack with dimensions 7.2 mm × 6.6 mm × 6.5 mm, and encapsulated in a steel tube filled with optically transparent silicone caulk. This encapsulation provides mechanical protection against shock and abrasion, as well as chemical protection against high salinity environments, while allowing the ambient pressure and temperature to be transferred to the sensing elements. Results are reported from high-temperature and high-pressure tests reaching 125°C and 7,250 psi in brine and other corrosive environments in laboratory conditions. Field tests that were conducted in a brine well to a maximum depth of 1,235 m are also described. The recorded data were post-processed to interpret the environmental pressure and temperature.