Zahra Karami Horastani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zahra Karami Horastani has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Fatemeh Karami Horestani
Department of Electrical Engineering, Mathematics and Science, University of Gvle, Gvle, Sweden
2 shared publications Khalil Seidali Javanmardi
2 shared publicationsReza Kadkhodaee
Department of Electrical Engineering, Shiraz Branch, Islamic Azad University, Shiraz, Iran
2 shared publicationsAli Bizaval
Department of Electrical Engineering, Shiraz Branch, Islamic Azad University, Shiraz, Iran
1 shared publication- Ali Karami Horestani
Khayyam Research Institute, Ministry of Science, Research and Technology, Tehran, Iran
1 shared publication - Ehsan Mohammadi
Department of Electrical Engineering, Islamic Azad University, Shiraz Branch, Shiraz, Iran
1 shared publication
Latest Publications
- 4 May 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (5) , 1-9
DFT study of (6,0) boron nitride nanotube as a drug delivery system for 5-fluorouracil and hydroxyurea
- 4 May 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (5) , 1-9
DFT study of (6,0) boron nitride nanotube as a drug delivery system for 5-fluorouracil and hydroxyurea
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14646-14657
DFT Study of SO₂F₂ and SOF₂ Adsorption on (6,0) AlN Nanotube: Adsorbent and Gas Detector Toward SF₆ Decomposition Products
This study investigates the adsorption effects of SO2F2 and SOF2 gases on the electronic properties of a (6,0) aluminum nitride (AlN) nanotube using density functional theory (DFT). Key calculations include the optimal ad-sorption configuration, adsorption energy, band structure, density of states, and charge transfer. The results indicate that both gases chemically adsorb onto the AlN nanotube surface. Given the stable adsorption of SO2F2 and SOF2 on the AlN nanotube, it is concluded that AlN nanotubes can serve as effective adsorbents for these decomposition prod-ucts, potentially reducing insulation degradation in SF₆-insulated environments. Other key findings include: 1) Follow-ing SO2F2 adsorption, the nanotube retains its p-type nature, though the Fermi level shifts up by 0.69 eV, indicating reduced conductivity; 2) SOF2 adsorption transforms the nanotube from a p-type to a weak n-type semiconductor; and 3) The work function of the nanotube decreases from 4.8 eV to 4.1 eV and 3.9 eV following the adsorption of SO2F2 and SOF2, respectively. Based on the observed changes in electrical conductivity, work function, and semiconductor be-havior, the study also proposes practical designs for resistive, Schottky, and thermoelectric power sensors. In conclu-sion, the AlN nanotube is identified as a promising candidate for sensor development and adsorbent applications tar-geting SO2F2 and SOF2 gases.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14646-14657
DFT Study of SO₂F₂ and SOF₂ Adsorption on (6,0) AlN Nanotube: Adsorbent and Gas Detector Toward SF₆ Decomposition Products
This study investigates the adsorption effects of SO2F2 and SOF2 gases on the electronic properties of a (6,0) aluminum nitride (AlN) nanotube using density functional theory (DFT). Key calculations include the optimal ad-sorption configuration, adsorption energy, band structure, density of states, and charge transfer. The results indicate that both gases chemically adsorb onto the AlN nanotube surface. Given the stable adsorption of SO2F2 and SOF2 on the AlN nanotube, it is concluded that AlN nanotubes can serve as effective adsorbents for these decomposition prod-ucts, potentially reducing insulation degradation in SF₆-insulated environments. Other key findings include: 1) Follow-ing SO2F2 adsorption, the nanotube retains its p-type nature, though the Fermi level shifts up by 0.69 eV, indicating reduced conductivity; 2) SOF2 adsorption transforms the nanotube from a p-type to a weak n-type semiconductor; and 3) The work function of the nanotube decreases from 4.8 eV to 4.1 eV and 3.9 eV following the adsorption of SO2F2 and SOF2, respectively. Based on the observed changes in electrical conductivity, work function, and semiconductor be-havior, the study also proposes practical designs for resistive, Schottky, and thermoelectric power sensors. In conclu-sion, the AlN nanotube is identified as a promising candidate for sensor development and adsorbent applications tar-geting SO2F2 and SOF2 gases.
- 31 August 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (8) , 1-9
The adsorption and sensing performances of (6,0) boron nitride nanotube toward mustard gas: a DFT study
- 31 August 2024
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 139 (8) , 1-9
The adsorption and sensing performances of (6,0) boron nitride nanotube toward mustard gas: a DFT study
- 30 November 2023
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 138 (11) , 1-9
New bipolar and half-semiconductor materials formed by (6, 0) boron nitride nanotube decorated with different concentrations of rhodium atom
- 30 November 2023
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 138 (11) , 1-9
New bipolar and half-semiconductor materials formed by (6, 0) boron nitride nanotube decorated with different concentrations of rhodium atom
- 18 September 2023
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 968
DFT study of Ag-X (X = Pd, Pt, Ag) decorated (8,0) single wall carbon nanotube for spintronic applications
- 18 September 2023
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 968
DFT study of Ag-X (X = Pd, Pt, Ag) decorated (8,0) single wall carbon nanotube for spintronic applications
- Open Access
- 30 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1087
A Band-Pass Instrumentation Amplifier Based on a Differential Voltage Current Conveyor for Biomedical Signal Recording Applications
Recently, due to their abundant benefits, current-mode instrumentation amplifiers have received considerable attention in medical instrumentation and read-out circuit for biosensors. This paper is focused on the design of current-mode instrumentation amplifiers for portable, implantable, and wearable electrocardiography and electroencephalography applications. To this end, a CMOS differential voltage second-generation current conveyor (DVCCII) based on a linear transconductor is presented. A new band-pass instrumentation amplifier, based on the designed DVCCII, is also implemented in this paper. The concept of the proposed differential voltage current conveyor and instrumentation amplifier is validated numerically and their predicted performance is presented. The simulation results of the presented circuits were tested for 0.18 μm TSMC CMOS technology in a post layout simulation level using the Cadence Virtuoso tool with a ±0.9 V power supply, and demonstrated that the designed DVCCII has a wide dynamic range of ±400 mV and ±0.85 mA and a power consumption of 148 μW. The layout of the DVCCII circuit occupies a total area of 0.378 μm2. It is shown that the designed DVCCII benefits from good linearity over a wide range of input signals and provides a low input impedance at terminal X. Two versions of the proposed band-pass instrumentation amplifier using pseudo resistances were designed with different specifications for two different applications, namely for EEG and ECG signals. Numerical analyses of both designs show proper outputs and frequency responses by eliminating the undesired artifact and DC component of the EEG and ECG input signals.
- 30 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1087
Open AccessA Band-Pass Instrumentation Amplifier Based on a Differential Voltage Current Conveyor for Biomedical Signal Recording Applications
Recently, due to their abundant benefits, current-mode instrumentation amplifiers have received considerable attention in medical instrumentation and read-out circuit for biosensors. This paper is focused on the design of current-mode instrumentation amplifiers for portable, implantable, and wearable electrocardiography and electroencephalography applications. To this end, a CMOS differential voltage second-generation current conveyor (DVCCII) based on a linear transconductor is presented. A new band-pass instrumentation amplifier, based on the designed DVCCII, is also implemented in this paper. The concept of the proposed differential voltage current conveyor and instrumentation amplifier is validated numerically and their predicted performance is presented. The simulation results of the presented circuits were tested for 0.18 μm TSMC CMOS technology in a post layout simulation level using the Cadence Virtuoso tool with a ±0.9 V power supply, and demonstrated that the designed DVCCII has a wide dynamic range of ±400 mV and ±0.85 mA and a power consumption of 148 μW. The layout of the DVCCII circuit occupies a total area of 0.378 μm2. It is shown that the designed DVCCII benefits from good linearity over a wide range of input signals and provides a low input impedance at terminal X. Two versions of the proposed band-pass instrumentation amplifier using pseudo resistances were designed with different specifications for two different applications, namely for EEG and ECG signals. Numerical analyses of both designs show proper outputs and frequency responses by eliminating the undesired artifact and DC component of the EEG and ECG input signals.
- Open Access
- 25 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 122951-122958
First-Principles Investigation of CH₄ Adsorption on a Singly and Doubly Decorated (8,0) Single Wall Carbon Nanotube With Palladium/Oxygen Species
We employ dispersion-corrected density functional theory to study adsorption of CH4 molecule on a singly and doubly decorated (8,0) single wall carbon nanotube (CNT80) with palladium atom and oxygen molecule. The obtained optimized energies indicate that double decoration with palladium atom and oxygen molecules significantly enhance adsorption of methane on the CNT80, while single decoration with oxygen molecules give rise to a weak physical bonding for methane molecule. Moreover, we observe that methane adsorption decreases the bandgap and the distance of the Fermi level to the top of the valance band of the doubly decorated CNT80. The calculated charge density plots and energy band diagrams demonstrate a charge transfer from doubly decorated CNT80 to CH4. Regarding the p-type nature of the structure, our results support increment of the conductance of the doubly decorated CNT80 after methane adsorption, in agreement with a real measurement in the ambient conditions. This observation underlines the importance of the ambient oxygen in the real performance of CNT based gas sensors.
- 25 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 122951-122958
Open AccessFirst-Principles Investigation of CH₄ Adsorption on a Singly and Doubly Decorated (8,0) Single Wall Carbon Nanotube With Palladium/Oxygen Species
We employ dispersion-corrected density functional theory to study adsorption of CH4 molecule on a singly and doubly decorated (8,0) single wall carbon nanotube (CNT80) with palladium atom and oxygen molecule. The obtained optimized energies indicate that double decoration with palladium atom and oxygen molecules significantly enhance adsorption of methane on the CNT80, while single decoration with oxygen molecules give rise to a weak physical bonding for methane molecule. Moreover, we observe that methane adsorption decreases the bandgap and the distance of the Fermi level to the top of the valance band of the doubly decorated CNT80. The calculated charge density plots and energy band diagrams demonstrate a charge transfer from doubly decorated CNT80 to CH4. Regarding the p-type nature of the structure, our results support increment of the conductance of the doubly decorated CNT80 after methane adsorption, in agreement with a real measurement in the ambient conditions. This observation underlines the importance of the ambient oxygen in the real performance of CNT based gas sensors.