Christina Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christina Lee has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Deanna H. Gates
Department of Biomedical Engineering University of Michigan Ann Arbor Michigan USA
5 shared publications - Cynthia A. Chestek
University of Michigan
3 shared publications - Michael A. Gonzalez
Robotics Institute, University of Michigan, Ann Arbor, MI, USA
3 shared publications - Jiyeon Kang
Department of AI Convergence, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
2 shared publications Alex Bismuth
School of Kinesiology, University of Michigan, Ann Arbor, MI, United States of America
1 shared publication- Alex K. Vaskov
Department of Plastic Surgery, University of Michigan, 1150 W Medical Center Drive, Ann Arbor, Michigan, 48109-1079, UNITED STATES
1 shared publication
Latest Publications
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Security & Privacy
- Vol. PP (15407993) , 2-13
Medical Data for Sale: Accessing Reproductive Health Information via the Data Brokerage Landscape
This study investigates the ease with which third parties can access and exploit intimate health data, including mental health- and abortion-related information after the Dobbs decision. Our findings demonstrate incongruities surrounding the perceived protections of HIPAA and the ready availability for the purchase of medical data.
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Security & Privacy
- Vol. PP (15407993) , 2-13
Medical Data for Sale: Accessing Reproductive Health Information via the Data Brokerage Landscape
This study investigates the ease with which third parties can access and exploit intimate health data, including mental health- and abortion-related information after the Dobbs decision. Our findings demonstrate incongruities surrounding the perceived protections of HIPAA and the ready availability for the purchase of medical data.
- Open Access
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2273-2285
Multi-Modal Sensing for Propulsion Estimation in People Post-Stroke Across Speeds
Gait rehabilitation is critical for regaining locomotor independence after neuromotor injuries like stroke. Rehabilitation literature indicates the need for such therapy to continue beyond the clinic in order to maintain motor function and support recovery. However, implementing community-based rehabilitation requires the ability to monitor gait in the real-world with clinically relevant accuracies. Despite advances in machine learning, achieving this performance with single sensing modalities has been challenging using wearable sensors like inertial measurement units (IMUs) and pressure insoles. Here, we investigate the benefits of multi-modal sensing by integrating IMU and insole data to develop individualized machine learning models in people post-stroke that estimate propulsion, a key biomechanical variable. We show that in the lab, IMU + Insole models improve performance with an average root-mean- squared-error (RMSE) of 0.80 %bodyweight (%BW) across the stance phase. We obtain RMSEs of 0.71 %BW for peak paretic propulsion and 0.19 %BW s for paretic propulsion impulse, which are within corresponding clinical thresholds. We then explore the application of this algorithm to track propulsion changes in the real-world for two participants during variable-speed walking and two participants during active gait interventions, either functional electrical stimulation or exosuit-applied resistance. For these participants, we observe similar changes in measured propulsion in the lab and estimated propulsion out of the lab across speeds and interventions. Overall, this work aims to address the challenges in applying machine learning methods for individuals post-stroke and presents an investigation into the feasibility of developing estimation methods for real-world propulsion estimation during gait rehabilitation.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 2273-2285
Open AccessMulti-Modal Sensing for Propulsion Estimation in People Post-Stroke Across Speeds
Gait rehabilitation is critical for regaining locomotor independence after neuromotor injuries like stroke. Rehabilitation literature indicates the need for such therapy to continue beyond the clinic in order to maintain motor function and support recovery. However, implementing community-based rehabilitation requires the ability to monitor gait in the real-world with clinically relevant accuracies. Despite advances in machine learning, achieving this performance with single sensing modalities has been challenging using wearable sensors like inertial measurement units (IMUs) and pressure insoles. Here, we investigate the benefits of multi-modal sensing by integrating IMU and insole data to develop individualized machine learning models in people post-stroke that estimate propulsion, a key biomechanical variable. We show that in the lab, IMU + Insole models improve performance with an average root-mean- squared-error (RMSE) of 0.80 %bodyweight (%BW) across the stance phase. We obtain RMSEs of 0.71 %BW for peak paretic propulsion and 0.19 %BW s for paretic propulsion impulse, which are within corresponding clinical thresholds. We then explore the application of this algorithm to track propulsion changes in the real-world for two participants during variable-speed walking and two participants during active gait interventions, either functional electrical stimulation or exosuit-applied resistance. For these participants, we observe similar changes in measured propulsion in the lab and estimated propulsion out of the lab across speeds and interventions. Overall, this work aims to address the challenges in applying machine learning methods for individuals post-stroke and presents an investigation into the feasibility of developing estimation methods for real-world propulsion estimation during gait rehabilitation.
- Open Access
Comparison of Inter-Joint Coordination Strategies during Activities of Daily Living with Prosthetic and Anatomical Limbs
While healthy individuals have redundant degrees of freedom of the joints, they coordinate their multi-joint movements such that the redundancy is effectively reduced. Achieving high inter-joint coordination may be difficult for upper limb prosthesis users due to the lack of proprioceptive feedback and limited motion of the terminal device. This study compared inter-joint coordination between prosthesis users and individuals without limb loss during different upper limb activities of daily living (ADLs). Nine unilateral prosthesis users (five males) and nine age- and sex-matched controls without limb loss completed three unilateral and three bilateral ADLs. Principal component analysis was applied to the three-dimensional motion trajectories of the trunk and arms to identify coordinative patterns. For each ADL, we quantified the cumulative variance accounted for (VAF) of the first five principal components (pcs), which was the lowest number of pcs that could achieve 90% VAF in control limb movements across all ADLs (5 < n < 9). The VAF was lower for movements involving a prosthesis compared to those completed by controls across all ADLs (p < 0.001). The pc waveforms were similar between movements involving a prosthesis and movements completed by control participants for pc1 (r > 0.78, p < 0.001). The magnitude of the relationship for pc2 and pc3 differed between ADLs, with the strongest correlation for symmetric bilateral ADLs (0.67 < r < 0.97, p < 0.001). Collectively, this study demonstrates that activities of daily living are less coordinated for prosthesis users compared to individuals without limb loss. Future work should explore how device features, such as the availability of sensory feedback or motorized wrist joints influence multi-joint coordination.
Open AccessComparison of Inter-Joint Coordination Strategies during Activities of Daily Living with Prosthetic and Anatomical Limbs
While healthy individuals have redundant degrees of freedom of the joints, they coordinate their multi-joint movements such that the redundancy is effectively reduced. Achieving high inter-joint coordination may be difficult for upper limb prosthesis users due to the lack of proprioceptive feedback and limited motion of the terminal device. This study compared inter-joint coordination between prosthesis users and individuals without limb loss during different upper limb activities of daily living (ADLs). Nine unilateral prosthesis users (five males) and nine age- and sex-matched controls without limb loss completed three unilateral and three bilateral ADLs. Principal component analysis was applied to the three-dimensional motion trajectories of the trunk and arms to identify coordinative patterns. For each ADL, we quantified the cumulative variance accounted for (VAF) of the first five principal components (pcs), which was the lowest number of pcs that could achieve 90% VAF in control limb movements across all ADLs (5 < n < 9). The VAF was lower for movements involving a prosthesis compared to those completed by controls across all ADLs (p < 0.001). The pc waveforms were similar between movements involving a prosthesis and movements completed by control participants for pc1 (r > 0.78, p < 0.001). The magnitude of the relationship for pc2 and pc3 differed between ADLs, with the strongest correlation for symmetric bilateral ADLs (0.67 < r < 0.97, p < 0.001). Collectively, this study demonstrates that activities of daily living are less coordinated for prosthesis users compared to individuals without limb loss. Future work should explore how device features, such as the availability of sensory feedback or motorized wrist joints influence multi-joint coordination.
- 14 November 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066010
Use of regenerative peripheral nerve interfaces and intramuscular electrodes to improve prosthetic grasp selection: a case study
Objective. Advanced myoelectric hands enable users to select from multiple functional grasps. Current methods for controlling these hands are unintuitive and require frequent recalibration. This case study assessed the performance of tasks involving grasp selection, object interaction, and dynamic postural changes using intramuscular electrodes with regenerative peripheral nerve interfaces (RPNIs) and residual muscles. Approach. One female with unilateral transradial amputation participated in a series of experiments to compare the performance of grasp selection controllers with RPNIs and intramuscular control signals with controllers using surface electrodes. These experiments included a virtual grasp-matching task with and without a concurrent cognitive task and physical tasks with a prosthesis including standardized functional assessments and a functional assessment where the individual made a cup of coffee (‘Coffee Task’) that required grasp transitions. Main results. In the virtual environment, the participant was able to select between four functional grasps with higher accuracy using the RPNI controller (92.5%) compared to surface controllers (81.9%). With the concurrent cognitive task, performance of the virtual task was more consistent with RPNI controllers (reduced accuracy by 1.1%) compared to with surface controllers (4.8%). When RPNI signals were excluded from the controller with intramuscular electromyography (i.e. residual muscles only), grasp selection accuracy decreased by up to 24%. The participant completed the Coffee Task with 11.7% longer completion time with the surface controller than with the RPNI controller. She also completed the Coffee Task with 11 fewer transition errors out of a maximum of 25 total errors when using the RPNI controller compared to surface controller. Significance. The use of RPNI signals in concert with residual muscles and intramuscular electrodes can improve grasp selection accuracy in both virtual and physical environments. This approach yielded consistent performance without recalibration needs while reducing cognitive load associated with pattern recognition for myoelectric control (clinical trial registration number NCT03260400).
- 14 November 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066010
Use of regenerative peripheral nerve interfaces and intramuscular electrodes to improve prosthetic grasp selection: a case study
Objective. Advanced myoelectric hands enable users to select from multiple functional grasps. Current methods for controlling these hands are unintuitive and require frequent recalibration. This case study assessed the performance of tasks involving grasp selection, object interaction, and dynamic postural changes using intramuscular electrodes with regenerative peripheral nerve interfaces (RPNIs) and residual muscles. Approach. One female with unilateral transradial amputation participated in a series of experiments to compare the performance of grasp selection controllers with RPNIs and intramuscular control signals with controllers using surface electrodes. These experiments included a virtual grasp-matching task with and without a concurrent cognitive task and physical tasks with a prosthesis including standardized functional assessments and a functional assessment where the individual made a cup of coffee (‘Coffee Task’) that required grasp transitions. Main results. In the virtual environment, the participant was able to select between four functional grasps with higher accuracy using the RPNI controller (92.5%) compared to surface controllers (81.9%). With the concurrent cognitive task, performance of the virtual task was more consistent with RPNI controllers (reduced accuracy by 1.1%) compared to with surface controllers (4.8%). When RPNI signals were excluded from the controller with intramuscular electromyography (i.e. residual muscles only), grasp selection accuracy decreased by up to 24%. The participant completed the Coffee Task with 11.7% longer completion time with the surface controller than with the RPNI controller. She also completed the Coffee Task with 11 fewer transition errors out of a maximum of 25 total errors when using the RPNI controller compared to surface controller. Significance. The use of RPNI signals in concert with residual muscles and intramuscular electrodes can improve grasp selection accuracy in both virtual and physical environments. This approach yielded consistent performance without recalibration needs while reducing cognitive load associated with pattern recognition for myoelectric control (clinical trial registration number NCT03260400).
- 12 October 2022
- Published by Springer Nature in Experimental Brain Research
- Vol. 240 (11) , 3011-3021
Temporal and spatial goal-directed reaching in upper limb prosthesis users
Understanding the fundamental characteristics of prosthetic movement control is imperative in improving prosthesis design and training. This study quantified how using an upper limb prosthesis affected performance during goal-directed reaching tasks. Nine prosthesis users with unilateral transradial limb absence and nine healthy controls completed a series of goal-directed reaching movements with different goals: one spatial and three temporal with different goal frequencies. We quantified end-point accuracy, smoothness, and peak speed for the spatial task and temporal accuracy, horizontal distance, and speed for the temporal task. For the temporal task, we also used a goal-equivalent manifold (GEM) approach to decompose variability in movement distance and speed into those perpendicular and tangential to the GEM. Detrended fluctuation analysis (DFA) quantified the temporal persistence of each time series. For the spatial task, movements made with prostheses were less smooth, had larger end-point errors, and had slower peak speed compared to those with control limbs (p < 0.041). For the temporal task, movements made with prostheses and intact limbs of prosthesis users and control limbs were similar in distance and speed and had similar timing errors (p > 0.138). Timing errors, distance, speed, and GEM deviations were corrected similarly between prosthetic limbs and control limbs (p > 0.091). The mean and variability of distance, speed, and perpendicular deviations decreased with increased goal frequency (p < 0.001). Our results suggest that prosthesis users have a sufficient internal model to successfully complete ballistic movements but are unable to accurately complete movements requiring substantial feedback.
- 12 October 2022
- Published by Springer Nature in Experimental Brain Research
- Vol. 240 (11) , 3011-3021
Temporal and spatial goal-directed reaching in upper limb prosthesis users
Understanding the fundamental characteristics of prosthetic movement control is imperative in improving prosthesis design and training. This study quantified how using an upper limb prosthesis affected performance during goal-directed reaching tasks. Nine prosthesis users with unilateral transradial limb absence and nine healthy controls completed a series of goal-directed reaching movements with different goals: one spatial and three temporal with different goal frequencies. We quantified end-point accuracy, smoothness, and peak speed for the spatial task and temporal accuracy, horizontal distance, and speed for the temporal task. For the temporal task, we also used a goal-equivalent manifold (GEM) approach to decompose variability in movement distance and speed into those perpendicular and tangential to the GEM. Detrended fluctuation analysis (DFA) quantified the temporal persistence of each time series. For the spatial task, movements made with prostheses were less smooth, had larger end-point errors, and had slower peak speed compared to those with control limbs (p < 0.041). For the temporal task, movements made with prostheses and intact limbs of prosthesis users and control limbs were similar in distance and speed and had similar timing errors (p > 0.138). Timing errors, distance, speed, and GEM deviations were corrected similarly between prosthetic limbs and control limbs (p > 0.091). The mean and variability of distance, speed, and perpendicular deviations decreased with increased goal frequency (p < 0.001). Our results suggest that prosthesis users have a sufficient internal model to successfully complete ballistic movements but are unable to accurately complete movements requiring substantial feedback.
- 8 September 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (5) , 051001
Artificial referred sensation in upper and lower limb prosthesis users: a systematic review
Objective. Electrical stimulation can induce sensation in the phantom limb of individuals with amputation. It is difficult to generalize existing findings as there are many approaches to delivering stimulation and to assessing the characteristics and benefits of sensation. Therefore, the goal of this systematic review was to explore the stimulation parameters that effectively elicited referred sensation, the qualities of elicited sensation, and how the utility of referred sensation was assessed. Approach. We searched PubMed, Web of Science, and Engineering Village through January of 2022 to identify relevant papers. We included papers which electrically induced referred sensation in individuals with limb loss and excluded papers that did not contain stimulation parameters or outcome measures pertaining to stimulation. We extracted information on participant demographics, stimulation approaches, and participant outcomes. Main results. After applying exclusion criteria, 49 papers were included covering nine stimulation methods. Amplitude was the most commonly adjusted parameter ( n = 25), followed by frequency ( n = 22), and pulse width ( n = 15). Of the 63 reports of sensation quality, most reported feelings of pressure ( n = 52), paresthesia ( n = 48), or vibration ( n = 40) while less than half ( n = 29) reported a sense of position or movement. Most papers evaluated the functional benefits of sensation ( n = 33) using force matching or object identification tasks, while fewer papers quantified subjective measures ( n = 16) such as pain or embodiment. Only 15 studies (36%) observed percept intensity, quality, or location over multiple sessions. Significance. Most studies that measured functional performance demonstrated some benefit to providing participants with sensory feedback. However, few studies could experimentally manipulate sensation location or quality. Direct comparisons between studies were limited by variability in methodologies and outcome measures. As such, we offer recommendations to aid in more standardized reporting for future research.
- 8 September 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (5) , 051001
Artificial referred sensation in upper and lower limb prosthesis users: a systematic review
Objective. Electrical stimulation can induce sensation in the phantom limb of individuals with amputation. It is difficult to generalize existing findings as there are many approaches to delivering stimulation and to assessing the characteristics and benefits of sensation. Therefore, the goal of this systematic review was to explore the stimulation parameters that effectively elicited referred sensation, the qualities of elicited sensation, and how the utility of referred sensation was assessed. Approach. We searched PubMed, Web of Science, and Engineering Village through January of 2022 to identify relevant papers. We included papers which electrically induced referred sensation in individuals with limb loss and excluded papers that did not contain stimulation parameters or outcome measures pertaining to stimulation. We extracted information on participant demographics, stimulation approaches, and participant outcomes. Main results. After applying exclusion criteria, 49 papers were included covering nine stimulation methods. Amplitude was the most commonly adjusted parameter ( n = 25), followed by frequency ( n = 22), and pulse width ( n = 15). Of the 63 reports of sensation quality, most reported feelings of pressure ( n = 52), paresthesia ( n = 48), or vibration ( n = 40) while less than half ( n = 29) reported a sense of position or movement. Most papers evaluated the functional benefits of sensation ( n = 33) using force matching or object identification tasks, while fewer papers quantified subjective measures ( n = 16) such as pain or embodiment. Only 15 studies (36%) observed percept intensity, quality, or location over multiple sessions. Significance. Most studies that measured functional performance demonstrated some benefit to providing participants with sensory feedback. However, few studies could experimentally manipulate sensation location or quality. Direct comparisons between studies were limited by variability in methodologies and outcome measures. As such, we offer recommendations to aid in more standardized reporting for future research.
- Open Access
- 11 May 2022
- Published by Springer Nature in Research Square
Long-term upper-extremity prosthetic control using Regenerative Peripheral Nerve Interfaces
Extracting motor signals directly from the peripheral nervous system poses challenges in obtaining both high amplitude and sustainable signals for upper-limb neuroprosthetic control. To translate peripheral nerve interfaces into the clinical space, these interfaces must provide consistent signals and prosthetic performance. Previously, we have demonstrated that the Regenerative Peripheral Nerve Interface (RPNI) is a biologically stable, bioamplifier of efferent motor action potentials. Here, we assessed the reliability of the RPNI signals in humans for long-term prosthetic control. RPNI signal quality, measured as signal-to-noise ratio, remained greater than 15 for up to 276 and 1054 days in participant 1 (P1), and participant 2 (P2), respectively. Though signal amplitude varied between sessions, P2 maintained prosthetic performance above 94% accuracy for 604 days without recalibration. Additionally, P2 completed a real-world multi-sequence coffee task with 99% accuracy 611 days without recalibration, demonstrating the potential of RPNIs as a long-term interface for enhanced prosthetic control.
- 11 May 2022
- Published by Springer Nature in Research Square
Open AccessLong-term upper-extremity prosthetic control using Regenerative Peripheral Nerve Interfaces
Extracting motor signals directly from the peripheral nervous system poses challenges in obtaining both high amplitude and sustainable signals for upper-limb neuroprosthetic control. To translate peripheral nerve interfaces into the clinical space, these interfaces must provide consistent signals and prosthetic performance. Previously, we have demonstrated that the Regenerative Peripheral Nerve Interface (RPNI) is a biologically stable, bioamplifier of efferent motor action potentials. Here, we assessed the reliability of the RPNI signals in humans for long-term prosthetic control. RPNI signal quality, measured as signal-to-noise ratio, remained greater than 15 for up to 276 and 1054 days in participant 1 (P1), and participant 2 (P2), respectively. Though signal amplitude varied between sessions, P2 maintained prosthetic performance above 94% accuracy for 604 days without recalibration. Additionally, P2 completed a real-world multi-sequence coffee task with 99% accuracy 611 days without recalibration, demonstrating the potential of RPNIs as a long-term interface for enhanced prosthetic control.
- Open Access
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1905-1912
Getting a Grip on the Impact of Incidental Feedback From Body-Powered and Myoelectric Prostheses
Sensory feedback from body-powered and myoelectric prostheses are limited, but in different ways. Currently, there are no empirical studies on how incidental feedback differs between body-powered and myoelectric prostheses, or how these differences impact grasping. Thus, the purpose of this study was to quantify differences in grasping performance between body-powered and myoelectric prosthesis users when presented with different forms of feedback. Nine adults with upper limb loss and nine without (acting as controls) completed two tasks in a virtual environment. In the first task, participants used visual, vibration, or force feedback to assist in matching target grasp apertures. In the second task, participants used either visual or force feedback to identify the stiffness of a virtual object. Participants using either prosthesis type improved their accuracy and reduced their variability compared to the no feedback condition when provided with any form of feedback (p <; 0.001). However, participants using body-powered prostheses were significantly more accurate and less variable at matching grasp apertures than those using myoelectric prostheses across all feedback conditions. When identifying stiffness, body-powered prosthesis users were more accurate using force feedback (64% compared to myoelectric users' 39%) while myoelectric users were more accurate using visual feedback (65% compared to body-powered users' 53%). This study supports previous findings that body-powered prosthesis users receive limited force and proprioceptive feedback, while myoelectric prosthesis users receive almost no force or proprioceptive feedback from their device. This work can inform future supplemental feedback that enhances rather than reproduces existing incidental feedback.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1905-1912
Open AccessGetting a Grip on the Impact of Incidental Feedback From Body-Powered and Myoelectric Prostheses
Sensory feedback from body-powered and myoelectric prostheses are limited, but in different ways. Currently, there are no empirical studies on how incidental feedback differs between body-powered and myoelectric prostheses, or how these differences impact grasping. Thus, the purpose of this study was to quantify differences in grasping performance between body-powered and myoelectric prosthesis users when presented with different forms of feedback. Nine adults with upper limb loss and nine without (acting as controls) completed two tasks in a virtual environment. In the first task, participants used visual, vibration, or force feedback to assist in matching target grasp apertures. In the second task, participants used either visual or force feedback to identify the stiffness of a virtual object. Participants using either prosthesis type improved their accuracy and reduced their variability compared to the no feedback condition when provided with any form of feedback (p <; 0.001). However, participants using body-powered prostheses were significantly more accurate and less variable at matching grasp apertures than those using myoelectric prostheses across all feedback conditions. When identifying stiffness, body-powered prosthesis users were more accurate using force feedback (64% compared to myoelectric users' 39%) while myoelectric users were more accurate using visual feedback (65% compared to body-powered users' 53%). This study supports previous findings that body-powered prosthesis users receive limited force and proprioceptive feedback, while myoelectric prosthesis users receive almost no force or proprioceptive feedback from their device. This work can inform future supplemental feedback that enhances rather than reproduces existing incidental feedback.