Hiroyuki Nishi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroyuki Nishi has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Yoshiki Sawa
Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
12 shared publications - Shigeru Miyagawa
Department of Cardiovascular Surgery The University of Osaka Graduate School of Medicine Osaka Japan
10 shared publications Toshiki Takahashi
Department of Cardiovascular Surgery, Osaka Police Hospital, Osaka, Japan
8 shared publications- Satsuki Fukushima
Department of Cardiac Surgery, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan
7 shared publications Takumi Ishikawa
6 shared publicationsYasushi Yoshikawa
Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamada-Oka, Suita, Osaka, 565-0871, Japan
6 shared publications
Latest Publications
- 1 September 2026
- Published by Springer Nature in Surgery Today
- p. 1-8
Safety and efficacy of tolvaptan sodium phosphate in patients undergoing open-heart surgery
- 1 September 2026
- Published by Springer Nature in Surgery Today
- p. 1-8
Safety and efficacy of tolvaptan sodium phosphate in patients undergoing open-heart surgery
- 5 January 2026
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 74 (7) , 666-672
Safety and efficacy of simple system for artificial chordae length adjustment in patients undergoing minimally invasive mitral valve repair
- 5 January 2026
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 74 (7) , 666-672
Safety and efficacy of simple system for artificial chordae length adjustment in patients undergoing minimally invasive mitral valve repair
- Open Access
- 17 May 2024
- Published by Springer Nature in Cureus
- Vol. 16 (5) , e60527
Diagnosis of Type IV Endoleak After Endovascular Aneurysm Repair Using Visualization With Novel Software
A Type IV endoleak is a very rare complication following endovascular aneurysm repair (EVAR) and differential diagnosis can be difficult. Reported here is a case that showed the development of a Type IV endoleak after an EVAR procedure, for which a novel software was useful to differentiate that from Type I based on visual confirmation. The 89-year-old man was diagnosed with a large abdominal aortic aneurysm, sized 70 mm, as shown by computed tomography (CT). EVAR was performed in a routine fashion using an Endurant II stent graft. Postoperative CT revealed a massive endoleak around the neck that was difficult to differentiate between Types I and IV. The use of the novel software Viewtify (SCIEMENT, Inc., Tokyo, Japan) to visualize the endoleak with surrounding tissues as real-time three-dimensional computer graphics (3DCG) resulted in confirmation that the endoleak was not from the proximal end but rather the stent graft body. CT findings obtained one week later showed that the endoleak had diminished and no additional procedures were needed. Following a diagnosis of endoleak after EVAR, images viewed with Viewtify helped to confirm the appropriate diagnosis. This novel software was found useful to clarify the position and mechanism of a Type IV endoleak.
- 17 May 2024
- Published by Springer Nature in Cureus
- Vol. 16 (5) , e60527
Open AccessDiagnosis of Type IV Endoleak After Endovascular Aneurysm Repair Using Visualization With Novel Software
A Type IV endoleak is a very rare complication following endovascular aneurysm repair (EVAR) and differential diagnosis can be difficult. Reported here is a case that showed the development of a Type IV endoleak after an EVAR procedure, for which a novel software was useful to differentiate that from Type I based on visual confirmation. The 89-year-old man was diagnosed with a large abdominal aortic aneurysm, sized 70 mm, as shown by computed tomography (CT). EVAR was performed in a routine fashion using an Endurant II stent graft. Postoperative CT revealed a massive endoleak around the neck that was difficult to differentiate between Types I and IV. The use of the novel software Viewtify (SCIEMENT, Inc., Tokyo, Japan) to visualize the endoleak with surrounding tissues as real-time three-dimensional computer graphics (3DCG) resulted in confirmation that the endoleak was not from the proximal end but rather the stent graft body. CT findings obtained one week later showed that the endoleak had diminished and no additional procedures were needed. Following a diagnosis of endoleak after EVAR, images viewed with Viewtify helped to confirm the appropriate diagnosis. This novel software was found useful to clarify the position and mechanism of a Type IV endoleak.
- Open Access
- 16 February 2022
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 34 (5) , 921-923
Successful redo aortic valve replacement using Perceval for multiple recurrent prosthetic valve dysfunction
A 50-year-old man who required aortic valve replacement (AVR) 3 times for severe paravalvular leakage (PVL) was diagnosed with a recurrence of severe PVL. Since the PVL recurred each time because of prosthetic valve detachment from the annulus, a fourth AVR was performed using a self-expanding sutureless valve. Postoperative echocardiography showed no significant PVL. The patient was discharged without any complications and returned to normal work soon after. In cases such as our patient, sutureless AVR could be a powerful alternative to conventional AVR.
- 16 February 2022
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 34 (5) , 921-923
Open AccessSuccessful redo aortic valve replacement using Perceval for multiple recurrent prosthetic valve dysfunction
A 50-year-old man who required aortic valve replacement (AVR) 3 times for severe paravalvular leakage (PVL) was diagnosed with a recurrence of severe PVL. Since the PVL recurred each time because of prosthetic valve detachment from the annulus, a fourth AVR was performed using a self-expanding sutureless valve. Postoperative echocardiography showed no significant PVL. The patient was discharged without any complications and returned to normal work soon after. In cases such as our patient, sutureless AVR could be a powerful alternative to conventional AVR.
- 10 November 2021
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 30 (6) , 661-668
Efficacy of simulation training for beating heart coronary anastomosis using BEAT + YOUCAN simulator
Background: We sought to evaluate our distributed practice program developed for training for beating heart anastomosis by employing a novel beating heart simulator. Methods: Eleven trainees watched and reviewed instructional video recordings of coronary anastomosis methods with a BEAT + YOUCAN training device, then performed coronary anastomosis procedures under a beating condition. Next, they participated in a four-hour training program developed by faculty surgeons. Ten different anastomosis components were assessed on a five-point rating scale (5, good; 3, average; 1, poor). After finishing the training program, each trainee again performed a coronary anastomosis procedure. Component scores were then compared before and after the training program. Results: The mean time to completion of the procedure improved from 1033 ± 424 to 795 ± 201 s (p < 0.05). Assessment scores improved from 1.88 ± 0.41 to 2.57 ± 0.30 (p < 0.05). Improvements in some technical components related to handling of instruments were noted (p < 0.05), whereas no significant improvement was seen with arteriotomy, graft orientation, suture management, or knot tying after finishing the training program. Conclusion: Trainees who participated in our four-hour focused training program for coronary anastomosis with a novel beating heart simulator showed improved ability under the beating condition in regard to technical skills related to handling instruments.
- 10 November 2021
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 30 (6) , 661-668
Efficacy of simulation training for beating heart coronary anastomosis using BEAT + YOUCAN simulator
Background: We sought to evaluate our distributed practice program developed for training for beating heart anastomosis by employing a novel beating heart simulator. Methods: Eleven trainees watched and reviewed instructional video recordings of coronary anastomosis methods with a BEAT + YOUCAN training device, then performed coronary anastomosis procedures under a beating condition. Next, they participated in a four-hour training program developed by faculty surgeons. Ten different anastomosis components were assessed on a five-point rating scale (5, good; 3, average; 1, poor). After finishing the training program, each trainee again performed a coronary anastomosis procedure. Component scores were then compared before and after the training program. Results: The mean time to completion of the procedure improved from 1033 ± 424 to 795 ± 201 s (p < 0.05). Assessment scores improved from 1.88 ± 0.41 to 2.57 ± 0.30 (p < 0.05). Improvements in some technical components related to handling of instruments were noted (p < 0.05), whereas no significant improvement was seen with arteriotomy, graft orientation, suture management, or knot tying after finishing the training program. Conclusion: Trainees who participated in our four-hour focused training program for coronary anastomosis with a novel beating heart simulator showed improved ability under the beating condition in regard to technical skills related to handling instruments.
- Open Access
- 23 June 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (9) , 3425-3428
Emergency aortic valve replacement complicated by unmanaged pheochromocytoma
A 53-year-old male undergoing emergency aortic valve replacement for infective endocarditis developed a hypertensive crisis early during the operation. Suspecting a pheochromocytoma, intravenous phentolamine was immediately administered, after which the procedure was completed as scheduled. Although quite rare, a pheochromocytoma can be encountered during emergency open heart surgery; thus, early recognition of abnormal blood pressure change and appropriate management are important. Here, we present details of blood pressure control mainly by use of phentolamine, in this case, to demonstrate effective management of a hypertensive crisis during emergency cardiac surgery because of a pheochromocytoma.
- 23 June 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (9) , 3425-3428
Open AccessEmergency aortic valve replacement complicated by unmanaged pheochromocytoma
A 53-year-old male undergoing emergency aortic valve replacement for infective endocarditis developed a hypertensive crisis early during the operation. Suspecting a pheochromocytoma, intravenous phentolamine was immediately administered, after which the procedure was completed as scheduled. Although quite rare, a pheochromocytoma can be encountered during emergency open heart surgery; thus, early recognition of abnormal blood pressure change and appropriate management are important. Here, we present details of blood pressure control mainly by use of phentolamine, in this case, to demonstrate effective management of a hypertensive crisis during emergency cardiac surgery because of a pheochromocytoma.
- 25 August 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 77 (1) , 106-108
Author’s reply: Can non-obstructive general angioscopy predict and aortic dissection before an attack?
- 25 August 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 77 (1) , 106-108
Author’s reply: Can non-obstructive general angioscopy predict and aortic dissection before an attack?
- 1 June 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 75 (6) , 606-613
Advent of New perioperative care for fluid management after cardiovascular surgery: A review of current evidence
- 1 June 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 75 (6) , 606-613
Advent of New perioperative care for fluid management after cardiovascular surgery: A review of current evidence
- 12 March 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 76 (1) , 60-65
Aortic angioscopy assisted thoracic endovascular repair for chronic type B aortic dissection
- 12 March 2020
- Published by Elsevier in Journal of Cardiology
- Vol. 76 (1) , 60-65
Aortic angioscopy assisted thoracic endovascular repair for chronic type B aortic dissection
- 1 October 2019
- Vol. 73 (5) , 419-425
Relationship between Sedentary Behavior and All-cause Mortality in Japanese Chronic Hemodialysis Patients: A Prospective Cohort Study
We investigated the relationship between sedentary behavior and all-cause mortality in patients undergoing hemodialysis. A total of 71 patients (39 men, 32 women, aged 72.1±11.7 years) were enrolled in this longitudinal study. Their sedentary behavior was measured using a tri-accelerometer that provides relative values per daily wearing time. We classified the sedentary behavior time into 2 groups (under the median: short-sedentary behavior (SB) group; over the median: long-SB group) and compared the groups' clinical parameters. We compared the groups' survival rates by using Kaplan-Meier curves and the log-rank test, and we performed multivariate analyses by a Cox-proportional hazard model to evaluate the relationship between the sedentary behavior and the survival rate. Twenty patients (28.2%) died during the observation period. The survival rate of the short-SB group was significantly higher than that of the long-SB group. Sedentary behavior was thus an important factor for all-cause mortality even after adjusting for confounding factors by a Cox-proportional hazard model. Sedentary behavior is closely linked to all-cause mortality, especially total days and non-hemodialysis days, and reducing sedentary behavior may be beneficial to reduce the all-cause mortality of patients on chronic hemodialysis.
- 1 October 2019
- Vol. 73 (5) , 419-425
Relationship between Sedentary Behavior and All-cause Mortality in Japanese Chronic Hemodialysis Patients: A Prospective Cohort Study
We investigated the relationship between sedentary behavior and all-cause mortality in patients undergoing hemodialysis. A total of 71 patients (39 men, 32 women, aged 72.1±11.7 years) were enrolled in this longitudinal study. Their sedentary behavior was measured using a tri-accelerometer that provides relative values per daily wearing time. We classified the sedentary behavior time into 2 groups (under the median: short-sedentary behavior (SB) group; over the median: long-SB group) and compared the groups' clinical parameters. We compared the groups' survival rates by using Kaplan-Meier curves and the log-rank test, and we performed multivariate analyses by a Cox-proportional hazard model to evaluate the relationship between the sedentary behavior and the survival rate. Twenty patients (28.2%) died during the observation period. The survival rate of the short-SB group was significantly higher than that of the long-SB group. Sedentary behavior was thus an important factor for all-cause mortality even after adjusting for confounding factors by a Cox-proportional hazard model. Sedentary behavior is closely linked to all-cause mortality, especially total days and non-hemodialysis days, and reducing sedentary behavior may be beneficial to reduce the all-cause mortality of patients on chronic hemodialysis.