VSVictor D. Selemir

Victor D. Selemir

*This is an algorithmically generated author record based on publicly available information.

Victor D. Selemir has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study of the effectiveness of nitric oxide use during and after heart valve surgery with cardiopulmonary bypass

    by V. V. Pichugin, A. V. Deryugina, V. D. Selemir, A. V. Bogush, R. D. Trofimov, A. S. Starshov, E. V. Sandalkin, I. A. Pakhomov, S. A. Zhilyaev, E. V. Knyazeva, et al.

    Aim. To assess the effect of nitric oxide administered into the extracorporeal circuit and during the three-day postoperative period on oxidative stress parameters and the state of red blood cells during operations with cardiopulmonary bypass (CPB).Material and Methods. The study included 106 patients who underwent heart valve surgeries and combined interventions under CPB. Two groups of patients were created: control (53 patients); study (53 patients). Nitric oxide (40 ppm) was supplied to the oxygenator of the CPB machine and by inhalation for three days after surgery. At the stages and after the surgery, the concentration of diene (DC) and triene (TC) conjugates, Schiff bases (SB); erythrocyte catalase activity (CA) was studied; aggregation and electrophoretic mobility of erythrocytes were measured. Clinical outcomes of surgeries were studied.Results. In patients of the control group, statistically significant increase in the content of DC (by 1.2 times) and SB (by 2.0 times) was registered by the end of the surgery compared to the initial values. SB content did not return to the preoperative level even by the end of the third day after the operation. A sharp decrease in CA activity by the end of the operation (by 24.1%) and its further decrease during three postoperative days were marked. A statistically significant increase in erythrocyte aggregation was established, starting from 60 min of CB (by 18.0% higher than the initial one), reaching a maximum by the end of the operation (by 20.4% higher than the initial one) and remaining above the initial level throughout the postoperative period. The use of nitric oxide during and after the surgery made it possible to statistically significantly decrease the level of DC, TC, SB; increase the activity of erythrocyte catalase; reduce erythrocyte aggregation and increase their electrophoretic mobility both during CBP and in the postoperative period.Conclusion. Cardiopulmonary bypass stimulates the development of lipid peroxidation (LPO) processes and erythrocyte damage, which occur during surgery and continue in the immediate postoperative period. Nitric oxide, used both during cardiopulmonary bypass and during the three-day postoperative period, effectively prevents the activation of LPO processes, has an antioxidant effect, reduces erythrocyte aggregation and increases their electrophoretic mobility. The positive effect of nitric oxide is noted not only during cardiopulmonary bypass, but also during the postoperative period, which improves the clinical outcomes of heart surgery.


  • Effects of inhaled nitric oxide in chronic obstructive pulmonary disease patients with hypercapnic respiratory failure and pulmonary hypertension

    by Tuyet Thi Struong, L. V. Shogenova, V. D. Selemir, A. G. Chuchalin

    Therapy with inhaled nitric oxide (iNO) in patients with hypercapnic respiratory failure (RF) and pulmonary arterial hypertension (PAH) is currently of scientific interest. The aim of this study was to evaluate the effects of iNO therapy on COPD patients with hypercapnic RF and PAH during exacerbation of the disease.Methods. A randomized, prospective, controlled trial included 30 patients with COPD (age 65 (62; 75) years) with hypercapnic RF and pulmonary arterial hypertension (PAH) treated at the State Budgetary City Teaching Hospital “City Clinical Hospital named after D.D.Pletnev of Healthcare Moscow City Department” (2021). The inclusion criteria were: PaCO2 ≥ 45 mm Hg and pulmonary artery systolic pressure PASP > 40 mm Hg as accessed by Doppler echocardiography. The patients were divided into two groups. Patients of the main group were administered iNO in the form of daily 90-minute sessons for two weeks using Tianoks device (Russian Federal Nuclear Center – All-Russian Research Institute of Experimental Physics, State Corporation “Rosatom”, Russia). Patients of the control group received treatment that corresponded to the severity of their COPD exacerbation according to the guidelines by Global Initiative for Chronic Obstructive Lung Disease (GOLD), 2020 – 2021. Hemodynamics and gas exchange, exercise tolerance, vascular stiffness, and obstructive disorders were assessed at baseline, on Days 7 and 14.Results. The main group demonstrated a decrease in PASP (38 (32; 43) mm Hg vs 47 (44; 54) mm Hg; p = 0.001), a decrease in stiffness index (SI) (7.03 m / s (5.3; 19.2) vs 12.2 m / s (5.7; 15.1); p = 0.01), decrease the pulmonary shunt fraction (Qs / Qt) (4.33% (3.7; 6.1) vs 9.12% (7.12; 11.3); p = 0.01), an increase in arterial vascular tone measured by reflective index (RI) (62.4% (51.2; 64.3) vs 58.5% (51.7; 63.8); p = 0.01), and increased exercise tolerance measured by 6-minute walking test (6MWT) (358.1 m (320.5; 368.2) vs 321.5 m (280.4; 329.1); p = 0.001) as compared to the control group.Conclusion. Our study indicates that iNO-therapy effectively reduces hypoxemia, endothelial dysfunction, improves hemodynamics, walking distance, and exercise tolerance during the exacerbation of COPD in patients with hypercapnic RF and PAH.


  • Open Access

    Inhalation therapy with nitric oxide synthesized from atmospheric air in the postoperative period of cardiac surgery in children: single-center retrospective cohort study

    by Andrei E. Bautin, V. D. Selemir, A. I. Nurgalieva, K. A. Morozov, V. G. Nikiforov, L. Z. Biktasheva, K. Yu. Afanasyeva, A. O. Marichev, D. M. Tashkhanov, L. I. Karpova, et al.

    Objectives. To study the clinical efficacy and safety of using the method of synthesis of nitric oxide (NO) from atmospheric air in the postoperative period of cardiac surgery in children with precapillary pulmonary hypertension (PH). Materials and methods. A clinical study with retrospective control included 90 patients (28 newborns and 62 children older than 28 days), including 40 boys and 50 girls, median age 0.25 (0.28; 1.17) years. The following inclusion criteria were determined: signed informed consent of the patientʼs legal representative, underwent heart surgery, mechanical controlled ventilation (MCV), pulmonary artery systolic pressure (PAPsys) ≥ 35 mm Hg. Exclusion criteria: methemoglobinemia, left ventricular failure III — IV, hemorrhagic diathesis. 45 children were included in the study group (inhalation of NO obtained by synthesis from atmospheric air using the AIT-NO-01 device), 45 children were included in the retrospective control group (application of the NO delivery method from cylinders, NOXBOX Mobile device (Bedfont, UK)). There were no differences in anthropometric parameters and severity of baseline precapillary PH between the groups. Results. After one hour of NO inhalation using the AIT-NO-01, a decrease in PAPsys was noted. by 33.3 % (p < 0.001). In the retrospective control group, after one hour of NO inhalation, there was a decrease in PAPsys by 26.7 % (p < 0.001). PAPsys decreased by 10 % or more in 40 (89 %) of patients in the study group and in 38 (84 %) of patients in the retrospective control group, (p = 0.4). Inhalation of NO obtained by the synthesis method from atmospheric air was associated with a shorter duration of MCV compared with the method of supply from cylinders: 12 (2; 28) h versus 14 (12.2; 70.5) h, p = 0.01. The length of ICU stay and postoperative complications rate did not differ in the study groups. There were no differences in the risk and severity of the side effects of NO inhalation therapy (the synthesis of methemoglobin and NO2) between the two methods studied. Conclusion. NO inhalation therapy after cardiac surgery in children using the AIT-NO-01 device has the same effectiveness and safety compared with the method of NO supply from cylinders.


  • Open Access

    Mobile x-ray complex based on ironless pulsed betatrons. X-ray complex conception for small-angle tomography

    by S G Kozlov, Yu P Kuropatkin, V I Nizhegorodtsev, K V Savchenko, V D Selemir, E V Urlin, O A Shamro

    The conception of creating mobile radiographic complex based on ironless pulsed betatrons is proposed for radiography of dynamic objects having large optical thicknesses. Realization of this conception allows: a) optimizing geometry of the hydrodynamic experiment at the expense of the change of the radiation source and recorder position relatively to the test object, located in the explosion-proof chamber(EPC). Thus, it lets the intensity of the x-ray radiation be increased twice in the recorder plane as compared with available Russian complexes; b) creating an efficient environment protection system at the expense of localization of dangerous explosion products, and a shock wave connected with them; c) significantly decreasing the cost of radiographic complexes, if not building heavy protective casemates and their infrastructure. Instead of them it is possible to use cheap rapidly erected constructions. The mobile radiographic complex is described. Its characteristics, obtained during the testing powering were provided. Thickness of the lead test at 1m from the tantalum target at the limiting energy of the betatron electron beam Elim~12 MeV( it is determined by the value of a capacitive storage of the pulsed powering system of the electromagnet) was ~115 mm. Conception of a multibeam complex creation based on ironless pulsed betatrons for small-angle tomography was also considered.


  • Effect of strong magnetic fields on gas adsorption

    by S. I. Krivosheev, G. A. Shneerson, V. V. Platonov, V. D. Selemir, O. M. Tatsenko, A. V. Filippov, E. A. Bychkova

    The effect of strong pulsed magnetic fields on gas adsorption at dielectric surfaces is demonstrated. We describe the experimental technique and the results indicating a considerable increase in the...


  • Disk Magnetocumulative Generator of 480-mm Diameter for Explosive EMIR Facility

    by Victor D. Selemir, V A Demidov, Alexander S. Boriskin, Sergey V. Bulyichev, Yuri V. Vlasov, Rinat M. Garipov, Sergey N. Golosov, S A Kazakov, Nataliya R. Kazakova, Sergey V. Kutumov, et al.

    The first test of a disk magnetocumulative generator (DMCG) with high explosive charges of 480-mm diameter was carried out in the frameworks of a program on creation of an explosive EMIR facility, intended for high-power soft X-ray radiation pulses generation.The generator consists of five disk elements. The inductive load was equal to ~ 7 nH. The generator was twice larger than model DMCG240, successfully tested earlier. A comparison of calculation and experimental results is carried out.


  • Producing a compact long-lived plasma formation

    by B. V. Alekhin, A. E. Dubinov, V. S. Zhdanov, V. G Kornilov, K. E. Mikheev, V. D. Selemir, N. V. Stepanov, V. I. Chelpanov, O. A. Shamro