Hwan Sik Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hwan Sik Kim has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yeong Hwan Ahn
Ajou University
3 shared publications - Gangseon Ji
Department of Physics, Ulsan National Institute of Science and Technology, Ulsan 44919, Republic of Korea
1 shared publication - Hye Ju Kim
Department of Physics Department of Energy Systems Research Ajou University Suwon 16499 Republic of Korea
1 shared publication - Hyeong-Ryeol Park
Department of Physics, Ulsan National Institute of Science and Technology, Ulsan 44919, Republic of Korea
1 shared publication - Hyoung-Taek Lee
Department of Physics Ulsan National Institute of Science and Technology (UNIST) Ulsan 44919 Republic of Korea
1 shared publication - Jangsun Kim
Panoptics Corp., Seongnam 13516, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Developing a Novel Terahertz Fabry–Perot Microcavity Biosensor by Incorporating Porous Film for Yeast Sensing
We present a novel terahertz (THz) Fabry–Perot (FP) microcavity biosensor that uses a porous polytetrafluoroethylene (PTFE) supporting film to improve microorganism detection. The THz FP microcavity confines and enhances fields in the middle of the cavity, where the target microbial film is placed with the aid of a PTFE film having a dielectric constant close to unity in the THz range. The resonant frequency shift increased linearly with increasing amount of yeasts, without showing saturation behavior under our experimental conditions. These results agree well with finite-difference time-domain (FDTD) simulations. The sensor’s sensitivity was 11.7 GHz/μm, close to the optimal condition of 12.5 GHz/μm, when yeast was placed at the cavity’s center, but no frequency shift was observed when the yeast was coated on the mirror side. We derived an explicit relation for the frequency shift as a function of the index, amount, and location of the substances that is consistent with the electric field distribution across the cavity. We also produced THz transmission images of yeast-coated PTFE, mapping the frequency shift of the FP resonance and revealing the spatial distribution of yeast.
Open AccessDeveloping a Novel Terahertz Fabry–Perot Microcavity Biosensor by Incorporating Porous Film for Yeast Sensing
We present a novel terahertz (THz) Fabry–Perot (FP) microcavity biosensor that uses a porous polytetrafluoroethylene (PTFE) supporting film to improve microorganism detection. The THz FP microcavity confines and enhances fields in the middle of the cavity, where the target microbial film is placed with the aid of a PTFE film having a dielectric constant close to unity in the THz range. The resonant frequency shift increased linearly with increasing amount of yeasts, without showing saturation behavior under our experimental conditions. These results agree well with finite-difference time-domain (FDTD) simulations. The sensor’s sensitivity was 11.7 GHz/μm, close to the optimal condition of 12.5 GHz/μm, when yeast was placed at the cavity’s center, but no frequency shift was observed when the yeast was coated on the mirror side. We derived an explicit relation for the frequency shift as a function of the index, amount, and location of the substances that is consistent with the electric field distribution across the cavity. We also produced THz transmission images of yeast-coated PTFE, mapping the frequency shift of the FP resonance and revealing the spatial distribution of yeast.
- Open Access
- 3 January 2023
- Published by Wiley in Nanophotonics
- Vol. 12 (1) , 147-154
Terahertz virus‐sized gold nanogap sensor
We demonstrated an ultra‐sensitive terahertz virus detection method combined with virus‐sized gold nanogaps filled with Al 2 O 3 . Large‐area high‐density 20 nm‐gap rectangular loop structures, containing a resonant frequency in the terahertz range, were fabricated on a 4‐inch wafer using atomic layer lithography. When target viruses with a 60 nm diameter were located on the nanogaps, we observed a significant redshift of the resonant peak already with an average number of about 100 viruses per unit loop due to the strong field confinement and enhancement near the gap. Furthermore, when the virus was tightly attached to an etched gap like a bridge connecting metals, its sensitivity is doubled compared to the unetched gap, which resulted in 400% more resonance frequency shift per single virus particle than our previous work. Full‐wave simulations and theoretical calculations based on modal expansions were in good agreement with the experiments, revealing that the resonant transmission spectrum was mostly determined by the change in refractive index in a two‐dimensional‐like optical hotspot near the nanogap. A further step could be taken to increase sensitivity by tuning nanogap‐loops to the absorption frequencies associated with the intermolecular vibrational modes of the viruses and fingerprinting them as well.
- 3 January 2023
- Published by Wiley in Nanophotonics
- Vol. 12 (1) , 147-154
Open AccessTerahertz virus‐sized gold nanogap sensor
We demonstrated an ultra‐sensitive terahertz virus detection method combined with virus‐sized gold nanogaps filled with Al 2 O 3 . Large‐area high‐density 20 nm‐gap rectangular loop structures, containing a resonant frequency in the terahertz range, were fabricated on a 4‐inch wafer using atomic layer lithography. When target viruses with a 60 nm diameter were located on the nanogaps, we observed a significant redshift of the resonant peak already with an average number of about 100 viruses per unit loop due to the strong field confinement and enhancement near the gap. Furthermore, when the virus was tightly attached to an etched gap like a bridge connecting metals, its sensitivity is doubled compared to the unetched gap, which resulted in 400% more resonance frequency shift per single virus particle than our previous work. Full‐wave simulations and theoretical calculations based on modal expansions were in good agreement with the experiments, revealing that the resonant transmission spectrum was mostly determined by the change in refractive index in a two‐dimensional‐like optical hotspot near the nanogap. A further step could be taken to increase sensitivity by tuning nanogap‐loops to the absorption frequencies associated with the intermolecular vibrational modes of the viruses and fingerprinting them as well.
- Open Access
- 11 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10594
Nondestructive Tomographic Imaging of Rust with Rapid THz Time-Domain Spectroscopy
In this study, we developed a rapid nondestructive tool for testing rust spread in a metal covered by a paint layer by using a THz time-domain spectroscopy system at a speed of 100 Hz/pixel. Time-of-flight imaging helps identify rust formation by exclusively obtaining the reflection from the steel below the paint surface. The use of frequency-selective imaging allows us to manipulate the contrast in rust imaging. Higher contrast is generally obtained when monitoring using the higher frequency component. In addition, we monitored the spread of rust in a steel plate under the influence of two different chemical solutions: NaCl and acid. We found that in the early stages, the decrease in THz reflection was governed by the high-frequency components due to the formation of lepidocrocite, whereas the low-frequency component develops as the proportion of hematite increases with time.
- 11 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10594
Open AccessNondestructive Tomographic Imaging of Rust with Rapid THz Time-Domain Spectroscopy
In this study, we developed a rapid nondestructive tool for testing rust spread in a metal covered by a paint layer by using a THz time-domain spectroscopy system at a speed of 100 Hz/pixel. Time-of-flight imaging helps identify rust formation by exclusively obtaining the reflection from the steel below the paint surface. The use of frequency-selective imaging allows us to manipulate the contrast in rust imaging. Higher contrast is generally obtained when monitoring using the higher frequency component. In addition, we monitored the spread of rust in a steel plate under the influence of two different chemical solutions: NaCl and acid. We found that in the early stages, the decrease in THz reflection was governed by the high-frequency components due to the formation of lepidocrocite, whereas the low-frequency component develops as the proportion of hematite increases with time.